eICU

45 papers · 115 extracted observations · mortality prediction · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Mortality Prediction.

0.10.40.71.0202220242025GCT, Original Loss function: 0.145 (2022)GCT, Original Loss function: 0.548 (2022)MUSE: 0.9017 (2024)MUSE+: 0.9332 (2024)MEDS-Tab (XGBoost): 0.855 (2024)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 12 of 12 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025Enhanced TimeAutoDiff proposed non-standard sliceMean subgroup AUROC estimation error0.028Binary Classification · split: test · cohort=large conditionally generated synthetic cohort · method=Enhanced TimeAutoDiff · outcome=LOS₍₂₄₎Enabling Granular Subgroup Level Model Evaluations by Generating Synthetic Medical Time Series
Source quote
L221: Fig.\@ \ref{fig4} shows that, in every case, the synthetic cohorts cut the error roughly in half compared to the small real‐test subsets (red bar), and our enhanced generator (Enhanced TimeAutoDiff) yields the lowest errors of all. For example, on eICU LOS-24 the mean error drops from 0.044 (Test) to 0.039 (TimeAutoDiff), 0.033 (TimeDiff), and 0.028 (Enhanced TimeAutoDiff); on MIMIC Mortality-24 it falls from 0.142 to 0.081, 0.088, and 0.081 respectively; On eICU Mortality-24: 0.075 → 0.061 → 0.056 → 0.050, and on MIMIC LOS-24: 0.067 → 0.043 → 0.049 → 0.042.
2025Small real test subset (Test) baseline non-standard sliceMean subgroup AUROC estimation error0.044Binary Classification · split: test · subset=small real test subset · outcome=LOS₍₂₄₎Enabling Granular Subgroup Level Model Evaluations by Generating Synthetic Medical Time Series
Source quote
L221: Fig.\@ \ref{fig4} shows that, in every case, the synthetic cohorts cut the error roughly in half compared to the small real‐test subsets (red bar), and our enhanced generator (Enhanced TimeAutoDiff) yields the lowest errors of all. For example, on eICU LOS-24 the mean error drops from 0.044 (Test) to 0.039 (TimeAutoDiff), 0.033 (TimeDiff), and 0.028 (Enhanced TimeAutoDiff); on MIMIC Mortality-24 it falls from 0.142 to 0.081, 0.088, and 0.081 respectively; On eICU Mortality-24: 0.075 → 0.061 → 0.056 → 0.050, and on MIMIC LOS-24: 0.067 → 0.043 → 0.049 → 0.042.
2024FedMAP proposedAUROC0.808Mortality Prediction · split: test · tier=1 · sites=51FedMAP: Personalised Federated Learning for Real Large-Scale Healthcare Systems
Source quote
L42: On the INTERVAL dataset (3 T1 sites), FedAvg achieved a median balanced accuracy of 0.760 (IQR: 0.013), with PFL methods showing mixed performance: pFedBayes reached 0.773 (IQR: 0.017), pFedGP 0.771 (IQR: 0.015), pFedFDA 0.768 (IQR: 0.010), and pFedME 0.737 (IQR: 0.025). Individual training achieved 0.779 (IQR: 0.025). FedMAP achieved the highest median balanced accuracy of 0.786 (IQR: 0.013). The eICU dataset (51 sites) showed similar patterns, with FedAvg achieving a median AUROC of 0.787 (IQR: 0.124), PFL methods ranging from pFedME's 0.772 (IQR: 0.107) to pFedGP's 0.732 (IQR: 0.173), and individual training at 0.701 (IQR: 0.139). FedMAP achieved a median AUROC of 0.808 (IQR: 0.116), significantly outperforming individual training (p<0.001, MD =0.098) and demonstrating improvement over FedAvg (p=0.057, MD =0.019).
2024FedAvg baselineAUROC0.787Mortality Prediction · split: test · tier=1 · sites=51FedMAP: Personalised Federated Learning for Real Large-Scale Healthcare Systems
Source quote
L42: On the INTERVAL dataset (3 T1 sites), FedAvg achieved a median balanced accuracy of 0.760 (IQR: 0.013), with PFL methods showing mixed performance: pFedBayes reached 0.773 (IQR: 0.017), pFedGP 0.771 (IQR: 0.015), pFedFDA 0.768 (IQR: 0.010), and pFedME 0.737 (IQR: 0.025). Individual training achieved 0.779 (IQR: 0.025). FedMAP achieved the highest median balanced accuracy of 0.786 (IQR: 0.013). The eICU dataset (51 sites) showed similar patterns, with FedAvg achieving a median AUROC of 0.787 (IQR: 0.124), PFL methods ranging from pFedME's 0.772 (IQR: 0.107) to pFedGP's 0.732 (IQR: 0.173), and individual training at 0.701 (IQR: 0.139). FedMAP achieved a median AUROC of 0.808 (IQR: 0.116), significantly outperforming individual training (p<0.001, MD =0.098) and demonstrating improvement over FedAvg (p=0.057, MD =0.019).
2019Graph Convolutional Transformer (GCT) proposedAUROC0.7502Readmission Prediction · split: testLearning the Graphical Structure of Electronic Health Records with Graph Convolutional Transformer
Source quote
L685: GCT\xspace │ 0.7525 (0.0128) │ 0.7502 (0.0114) │ 0.9089 (0.0052) │ 0.9120 (0.0048)
2019Deep baselineAUROC0.7412Readmission Prediction · split: testLearning the Graphical Structure of Electronic Health Records with Graph Convolutional Transformer
Source quote
L683: Deep │ 0.7478 (0.0124) │ 0.7412 (0.0074) │ 0.9101 (0.0057) │ 0.9092 (0.0060)
2018Distributed Private proposedAUROC0.662Mortality Prediction · split: test · institutions=1Privacy-Preserving Distributed Deep Learning for Clinical Data
Source quote
L84: 1 │ 0.743 │ 0.683 │ 0.738 │ 0.662
2018Distributed Private proposedAUROC0.706Mortality Prediction · split: test · institutions=2Privacy-Preserving Distributed Deep Learning for Clinical Data
Source quote
L85: 2 │ 0.760 │ 0.720 │ 0.762 │ 0.706
2018Distributed Private proposedAUROC0.753Mortality Prediction · split: test · institutions=3Privacy-Preserving Distributed Deep Learning for Clinical Data
Source quote
L86: 3 │ 0.794 │ 0.780 │ 0.789 │ 0.753
2018Central Private baselineAUROC0.683Mortality Prediction · split: test · institutions=1Privacy-Preserving Distributed Deep Learning for Clinical Data
Source quote
L84: 1 │ 0.743 │ 0.683 │ 0.738 │ 0.662
2018Central Private baselineAUROC0.720Mortality Prediction · split: test · institutions=2Privacy-Preserving Distributed Deep Learning for Clinical Data
Source quote
L85: 2 │ 0.760 │ 0.720 │ 0.762 │ 0.706
2018Central Private baselineAUROC0.780Mortality Prediction · split: test · institutions=3Privacy-Preserving Distributed Deep Learning for Clinical Data
Source quote
L86: 3 │ 0.794 │ 0.780 │ 0.789 │ 0.753