EHR
6 papers · 14 extracted observations · classification · Markdown · CSV · JSON API
Tasks on EHRAll tasks (6)Classification (1)Diabetes Prediction (1)Drug Imputation (1)Ehr Reconstruction (1)Evasion Attack (1)Image Classification (1)Regression (1)Topic Modeling (1)
TaskClassification (2)Regression (2)Ehr Reconstruction (2)Topic Modeling (2)Drug Imputation (2)Diabetes Prediction (2)Evasion Attack (1)
Splittest (6)
Showing 6 of 6 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2022 | KG-ETM proposed | f1-score@5 | 0.1569 | Drug Imputation · split: test · cutoff=5 · filter=exclude patients with fewer than 5 ATC codes · evaluation=patient-wise | Modeling electronic health record data using a knowledge-graph-embedded topic modelSource quoteL266: KG-ETM │ 0.2600 │ 0.1225 │ 0.1569 |
| 2022 | GETM baseline | f1-score@5 | 0.1418 | Drug Imputation · split: test · cutoff=5 · filter=exclude patients with fewer than 5 ATC codes · evaluation=patient-wise | Modeling electronic health record data using a knowledge-graph-embedded topic modelSource quoteL265: GETM │ 0.2378 │ 0.1101 │ 0.1418 |
| 2021 | CuteMaxVar-Deep proposed | classification accuracy | 80% | Classification · split: test | Communication-Efficient Distributed Linear and Deep Generalized Canonical Correlation AnalysisSource quoteL613: Fig.~\ref{fig:class_acc_ehr} shows the classification accuracy achieved by the algorithms on the test set against the communication cost and number of iterations, which are averaged over 10 trials due to the randomness of SGD. One can see that although \texttt{AltMaxVar-Deep} improves its classification accuracy using fewer iterations in the beginning, both methods reach the best accuracy using around the same number of iterations (Fig.~\ref{fig:class_acc_ehr} [right]). However, \texttt{CuteMaxVar-Deep} costs significantly less communication overhead to reach the same accuracy level. In particular, to attain an 80% classification accuracy, \texttt{CuteMaxVar-Deep} works with \texttt{CR}=0.867. |
| 2021 | CuteMaxVar-Deep proposed | CR | 0.867 | Classification · split: test | Communication-Efficient Distributed Linear and Deep Generalized Canonical Correlation AnalysisSource quoteL613: Fig.~\ref{fig:class_acc_ehr} shows the classification accuracy achieved by the algorithms on the test set against the communication cost and number of iterations, which are averaged over 10 trials due to the randomness of SGD. One can see that although \texttt{AltMaxVar-Deep} improves its classification accuracy using fewer iterations in the beginning, both methods reach the best accuracy using around the same number of iterations (Fig.~\ref{fig:class_acc_ehr} [right]). However, \texttt{CuteMaxVar-Deep} costs significantly less communication overhead to reach the same accuracy level. In particular, to attain an 80% classification accuracy, \texttt{CuteMaxVar-Deep} works with \texttt{CR}=0.867. |
| 2018 | SIGN (PPMx) proposed non-standard slice | AUC | 0.880 | Diabetes Prediction · split: test · subset=GAN-replicated EHR data | Scalable Bayesian Nonparametric Clustering and ClassificationSource quoteL786: SIGN │ 0.808 (0.067) │ 0.838 (0.067) │ 0.880 │ 0.825 |
| 2018 | RF baseline non-standard slice | AUC | 0.869 | Diabetes Prediction · split: test · subset=GAN-replicated EHR data | Scalable Bayesian Nonparametric Clustering and ClassificationSource quoteL789: RF │ 0.793 (0.059) │ 0.838 (0.067) │ 0.869 │ 0.786 |