DexYCB
57 papers · 149 extracted observations · 3d hand pose estimation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=s0.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↓ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | 2-stages Keypoint-Fusion SOTA frontier | 6.94 mm | 2024-01-01 | Default S0 split; comparison across fusion-stage configurations. | Keypoint Fusion for RGB-D Based 3D Hand Pose EstimationSource quote6.94 |
| 2 | IPNet (Depth &Point) SOTA frontier | 8.03 mm | 2023-01-01 | split_protocol=sequences · Official DexYCB S0 split; S0 is split by sequences. | Two Heads Are Better than One: Image-Point Cloud Network for Depth-Based 3D Hand Pose EstimationSource quote8.03 |
Showing 52 of 52 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | DynamicHOI proposed | MPJPE | 9.51 | split: test · backbone=clip | DynamicHOI: Coupled Dynamics for Physics-aware HOI ReconstructionSource quoteL392: 9.51 |
| 2026 | FAH-L proposed non-standard slice | vertex F1 | 0.76 | split: test | Fast and Accurate Hand Estimation in Pixels, Interaction and World SpaceSource quoteL925: 0.80 0.85 0.98 0.76 0.82 0.98 |
| 2026 | PAD-Hand | MPJPE | 10.56 | split: test · backbone=clip | DynamicHOI: Coupled Dynamics for Physics-aware HOI ReconstructionSource quoteL387: 10.56 |
| 2025 | H2R-Grounder proposed | Human preference rate — Physical Plausibility first-rank rate | 63.6% | split: test · camera=932122062010 top-down · subject=01 · study-participants=22 | H2R-Grounder: A Paired-Data-Free Paradigm for Translating Human Interaction Videos into Physically Grounded Robot VideosSource quoteL208: Ours │ 54.5% │ 56.8% │ 61.4% │ 63.6% |
| 2025 | H2R-Grounder proposed | Human preference rate — Visual Quality first-rank rate | 61.4% | split: test · camera=932122062010 top-down · subject=01 · study-participants=22 | H2R-Grounder: A Paired-Data-Free Paradigm for Translating Human Interaction Videos into Physically Grounded Robot VideosSource quoteL208: Ours │ 54.5% │ 56.8% │ 61.4% │ 63.6% |
| 2025 | H2R-Grounder proposed | Human preference rate — Motion Consistency first-rank rate | 54.5% | split: test · camera=932122062010 top-down · subject=01 · study-participants=22 | H2R-Grounder: A Paired-Data-Free Paradigm for Translating Human Interaction Videos into Physically Grounded Robot VideosSource quoteL208: Ours │ 54.5% │ 56.8% │ 61.4% │ 63.6% |
| 2025 | Physics-augmented diffusion refinement (HaMer input) proposed | MJE | 17.5 mm | split: test · input=HaMer | Diffusion-based 3D Hand Motion Recovery with Intuitive PhysicsSource quoteL205: Comparison with SOTA Motion Refinement. The most closely related work to our approach is PoseBERT, a leading motion refinement model that employs a Transformer encoder model trained with random input masking and noise perturbations. We compare our physics-augmented diffusion-based motion refinement model with PoseBERT on two widely used frame-wise reconstruction models: KNOWN-Hand (K-Hand) and HaMer. K-Hand leverages generic hand knowledge, while HaMer relies on large-scale hand data to achieve good reconstruction accuracy. While both PoseBERT and our method improve upon these frame-wise reconstructions, our method achieves more significant improvements across all metrics, in terms of both reconstruction accuracy and physical plausibility as shown in Table~\ref{tab:sotarefine}. Specifically, when refining K-Hand (24.4 mm MJE), our method achieves 21.7 mm MJE, outperforming PoseBERT's 22.3 mm. Similarly for HaMer (18.9 mm MJE), we achieve 17.5 mm MJE, better than PoseBERT's 18.0 mm. The improvements in physical plausibility are even more pronounced. Our method reduces ACCL values to 1.30 mm/frame^2 and 1.18 mm/frame^2, compared to K-Hand's 14.41 mm/frame^2 and HaMer's 7.95 mm/frame^2, substantially surpassing PoseBERT's improvements of 3.33 and 2.38 mm/frame^2, respectively. These consistent improvements across different frame-wise models demonstrate the effectiveness of our approach in leveraging diffusion modeling and intuitive physics for enhanced motion refinement. Next, we demonstrate our advantages over existing methods for 3D hand reconstruction from monocular videos. |
| 2025 | VPHO full ablation configuration (physics-based aggregation included) ablation | CP | 98.85% | split: test · evaluation=ablation; test set not stated · configuration=physics-based aggregation included | VPHO: Joint Visual-Physical Cue Learning and Aggregation for Hand-Object Pose EstimationSource quoteL552: Finally, the inclusion of the physics-based aggregation module yields the best overall results. It achieves the lowest errors across all metrics, particularly in physics-based evaluations: CP increases from 97.95% to 98.85%, while PD and SD drop from 13.9 mm to 13.4 mm and from 20.0 mm to 17.3 mm, respectively. These gains confirm the effectiveness of the proposed physics-based aggregation strategy in enhancing physical plausibility for hand-object pose estimation results. |
| 2025 | VPHO full ablation configuration (physics-based aggregation included) ablation | PD | 13.4 mm | split: test · evaluation=ablation; test set not stated · configuration=physics-based aggregation included | VPHO: Joint Visual-Physical Cue Learning and Aggregation for Hand-Object Pose EstimationSource quoteL552: Finally, the inclusion of the physics-based aggregation module yields the best overall results. It achieves the lowest errors across all metrics, particularly in physics-based evaluations: CP increases from 97.95% to 98.85%, while PD and SD drop from 13.9 mm to 13.4 mm and from 20.0 mm to 17.3 mm, respectively. These gains confirm the effectiveness of the proposed physics-based aggregation strategy in enhancing physical plausibility for hand-object pose estimation results. |
| 2025 | VPHO full ablation configuration (physics-based aggregation included) ablation | SD | 17.3 mm | split: test · evaluation=ablation; test set not stated · configuration=physics-based aggregation included | VPHO: Joint Visual-Physical Cue Learning and Aggregation for Hand-Object Pose EstimationSource quoteL552: Finally, the inclusion of the physics-based aggregation module yields the best overall results. It achieves the lowest errors across all metrics, particularly in physics-based evaluations: CP increases from 97.95% to 98.85%, while PD and SD drop from 13.9 mm to 13.4 mm and from 20.0 mm to 17.3 mm, respectively. These gains confirm the effectiveness of the proposed physics-based aggregation strategy in enhancing physical plausibility for hand-object pose estimation results. |
| 2025 | HFL-Net | ADD-0.5D (average) | 41.59% | split: test | UniHOPE: A Unified Approach for Hand-Only and Hand-Object Pose EstimationSource quoteL333: HFL-Net~\cite{lin2023harmonious} │ 25.88 │ 32.08 │ 70.16 │ 41.59 |
| 2025 | HandOccNet non-standard slice | J-PE | 28.15 mm | split: test | UniHOPE: A Unified Approach for Hand-Only and Hand-Object Pose EstimationSource quoteL475: HandOccNet~\cite{park2022handoccnet} │ 16.40 │ 7.08 │ 15.85 │ 6.83 │ 18.22 │ 7.60 │ 17.67 │ 7.33 │ 28.15 │ 8.71 │ 27.20 │ 8.40 |
| 2025 | 1-agent AR | GEO | 0.919 rad | split: test | Poly-Autoregressive Prediction for Modeling InteractionsSource quoteL271: Rotation │ 1-agent AR │ 0.919 |
| 2025 | 2-agent PAR | GEO | 0.837 rad | split: test | Poly-Autoregressive Prediction for Modeling InteractionsSource quoteL272: Rotation │ 2-agent PAR │ 0.837 |
| 2025 | RoboMaster baseline | Human preference rate — Physical Plausibility first-rank rate | 18.2% | split: test · camera=932122062010 top-down · subject=01 · study-participants=22 | H2R-Grounder: A Paired-Data-Free Paradigm for Translating Human Interaction Videos into Physically Grounded Robot VideosSource quoteL205: RoboMaster~\cite{robomaster} │ 2.3% │ 2.3% │ 2.3% │ 18.2% |
| 2025 | Kling baseline | Human preference rate — Visual Quality first-rank rate | 40.9% | split: test · camera=932122062010 top-down · subject=01 · study-participants=22 | H2R-Grounder: A Paired-Data-Free Paradigm for Translating Human Interaction Videos into Physically Grounded Robot VideosSource quoteL207: Kling~\cite{kling} │ 9.1% │ 34.1% │ 40.9% │ 9.1% |
| 2025 | Runway Aleph baseline | Human preference rate — Motion Consistency first-rank rate | 22.7% | split: test · camera=932122062010 top-down · subject=01 · study-participants=22 | H2R-Grounder: A Paired-Data-Free Paradigm for Translating Human Interaction Videos into Physically Grounded Robot VideosSource quoteL206: Runway Aleph~\cite{aleph} │ 22.7% │ 15.9% │ 9.1% │ 6.8% |
| 2025 | HOISDF baseline | OCE | 18.4 mm | split: test · protocol=S0 | Occlusion-Aware 3D Hand-Object Pose Estimation with Masked AutoEncodersSource quoteL205: HOISDF \cite{qi2024hoisdf} │ 10.1 │ 5.31 │ 18.4 │ 27.4 │ 13.3 |
| 2025 | PoseBERT refinement (HaMer input) baseline | MJE | 18.0 mm | split: test · input=HaMer | Diffusion-based 3D Hand Motion Recovery with Intuitive PhysicsSource quoteL205: Comparison with SOTA Motion Refinement. The most closely related work to our approach is PoseBERT, a leading motion refinement model that employs a Transformer encoder model trained with random input masking and noise perturbations. We compare our physics-augmented diffusion-based motion refinement model with PoseBERT on two widely used frame-wise reconstruction models: KNOWN-Hand (K-Hand) and HaMer. K-Hand leverages generic hand knowledge, while HaMer relies on large-scale hand data to achieve good reconstruction accuracy. While both PoseBERT and our method improve upon these frame-wise reconstructions, our method achieves more significant improvements across all metrics, in terms of both reconstruction accuracy and physical plausibility as shown in Table~\ref{tab:sotarefine}. Specifically, when refining K-Hand (24.4 mm MJE), our method achieves 21.7 mm MJE, outperforming PoseBERT's 22.3 mm. Similarly for HaMer (18.9 mm MJE), we achieve 17.5 mm MJE, better than PoseBERT's 18.0 mm. The improvements in physical plausibility are even more pronounced. Our method reduces ACCL values to 1.30 mm/frame^2 and 1.18 mm/frame^2, compared to K-Hand's 14.41 mm/frame^2 and HaMer's 7.95 mm/frame^2, substantially surpassing PoseBERT's improvements of 3.33 and 2.38 mm/frame^2, respectively. These consistent improvements across different frame-wise models demonstrate the effectiveness of our approach in leveraging diffusion modeling and intuitive physics for enhanced motion refinement. Next, we demonstrate our advantages over existing methods for 3D hand reconstruction from monocular videos. |
| 2024 | NCRF proposed | PSNR | 32.16 | split: test | NCRF: Neural Contact Radiance Fields for Free-Viewpoint Rendering of Hand-Object InteractionSource quoteL200: DexYCB │ 27.32 │ 32.16 │ 0.9719 │ 0.9813 │ 27.43 │ 20.37 |
| 2024 | Proposed method (with NLL) proposed | EJ (average 3D joint-position Euclidean distance after Procrustes alignment) | 6.7 mm | split: test · weakly-supervised · alignment=Procrustes · uncertainty-loss=NLL | Weakly-Supervised 3D Hand Reconstruction with Knowledge Prior and Uncertainty GuidanceSource quoteL230: 6.7 22.0 10.0 0.800 |
| 2024 | GraspDiffusion full-body grasping-pose model (table label “Ours”) proposed | Pose Valid Error ↓ | 0.111 | split: test · body-shapes=10 · novel-objects=10 · object-positions-per-pair=64 | GraspDiffusion: Synthesizing Realistic Whole-body Hand-Object InteractionSource quoteL175: Ours │ 0.909 │ 0.111 │ 2.696 |
| 2024 | HOISDF (cross feature enhancement, ours) proposed | MJE | 10.1 mm | split: test | HOISDF: Constraining 3D Hand-Object Pose Estimation with Global Signed Distance FieldsSource quoteL347: Cross feature enhancement (ours) │ 10.1 │ 5.31 │ 18.4 │ 27.4 │ 13.3 |
| 2024 | HOISDF (cross feature enhancement, ours) proposed | OCE | 18.4 mm | split: test | HOISDF: Constraining 3D Hand-Object Pose Estimation with Global Signed Distance FieldsSource quoteL347: Cross feature enhancement (ours) │ 10.1 │ 5.31 │ 18.4 │ 27.4 │ 13.3 |
| 2024 | gSDF + BioPR proposed | MPJPE | 12.81 mm | split: test · protocol=default S0 train/test split · evaluation=wrist-relative mean joint distance over 21 joints | MS-MANO: Enabling Hand Pose Tracking with Biomechanical ConstraintsSource quoteL234: gSDF + BioPR │ 12.81 │ 89.7 │ 29.9 Deformer~\cite{deformer} │ 13.64 │ 89.6 │ 31.7 |
| 2024 | gSDF + BioPR proposed | AUC | 89.7 | split: test · protocol=default S0 train/test split · evaluation=official dataset evaluation system | MS-MANO: Enabling Hand Pose Tracking with Biomechanical ConstraintsSource quoteL234: gSDF + BioPR │ 12.81 │ 89.7 │ 29.9 Deformer~\cite{deformer} │ 13.64 │ 89.6 │ 31.7 |
| 2024 | MCC-HO proposed non-standard slice | F-5 | 0.36 | split: test · subset=s0 · alignment=ICP-and-scaling · hand_geometry=ground-truth · frame_sampling=every-fifth-frame | Reconstructing Hand-Held Objects in 3D from Images and VideosSource quoteL260: MCC-HO (Ours) │ 0.36 │ 0.60 │ 3.74 │ 0.15 │ 0.31 │ 15.2 │ 0.52 │ 0.78 │ 1.36 |
| 2024 | Dexgraspnet + * ablation | Suc. R. (success rate) | 65% | split: test · subset=25% DexYCB grasp-reference test set · simulation=Sim | FunGrasp: Functional Grasping for Diverse Dexterous HandsSource quoteL250: Dexgraspnet + * │ 65% │ 1.6 │ 0.68 |
| 2024 | HumanNeRF | PSNR | 27.32 | split: test | NCRF: Neural Contact Radiance Fields for Free-Viewpoint Rendering of Hand-Object InteractionSource quoteL200: DexYCB │ 27.32 │ 32.16 │ 0.9719 │ 0.9813 │ 27.43 │ 20.37 |
| 2024 | COOP baseline | Pose Valid Error ↓ | 0.239 | split: test · body-shapes=10 · novel-objects=10 · training-data=GRAB · object-positions-per-pair=64 | GraspDiffusion: Synthesizing Realistic Whole-body Hand-Object InteractionSource quoteL174: COOP \cite{Zheng_2023_ICCV} │ 0.841 │ 0.239 │ 4.679 |
| 2023 | WSIM 3D Hand (Ours (GCN)) proposed | MPVPE | 9.12 | split: test · subset=S0 · backbone=ResNet-50 | Overcoming the TradeOff between Accuracy and Plausibility in 3D Hand Shape ReconstructionSource quoteL170: Ours (GCN) │ 7.42 │ 7.43 │ 0.51 │ 0.15 │ 9.68 │ 9.89 │ 0.27 │ 0.12 │ 8.92 │ 9.12 │ 0.25 │ 0.12 |
| 2023 | WSIM 3D Hand (Ours (GCN)) proposed | Edge error distance | 0.25 mm | split: test · subset=S0 · backbone=ResNet-50 | Overcoming the TradeOff between Accuracy and Plausibility in 3D Hand Shape ReconstructionSource quoteL170: Ours (GCN) │ 7.42 │ 7.43 │ 0.51 │ 0.15 │ 9.68 │ 9.89 │ 0.27 │ 0.12 │ 8.92 │ 9.12 │ 0.25 │ 0.12 |
| 2023 | DiffHand proposed | E-PJ | 4.98 mm | split: test · backbone=HRNet · inference-steps=10 DDIM | DiffHand: End-to-End Hand Mesh Reconstruction via Diffusion ModelsSource quoteL189: DiffHand(Ours) │ \textcolor{red}{12.1} │ \textcolor{red}{4.98} |
| 2023 | DiffHand proposed | E_J | 12.1 mm | split: test · backbone=HRNet · inference-steps=10 DDIM | DiffHand: End-to-End Hand Mesh Reconstruction via Diffusion ModelsSource quoteL189: DiffHand(Ours) │ \textcolor{red}{12.1} │ \textcolor{red}{4.98} |
| 2023 | HandNeRF proposed | Object F-score at 10mm threshold (F_o-10) | 0.52 | split: test · object=Banana · subset=novel objects · metric-threshold=10mm | HandNeRF: Learning to Reconstruct Hand-Object Interaction Scene from a Single RGB ImageSource quoteL496: HandNeRF │ 18.83 │ 0.55 │ 0.60 │ 0.31 │ 0.33 │ 0.65 │ 0.48 │ 0.29 │ 0.52 │ 0.76 │ 0.32 │ 0.65 │ 0.70 |
| 2023 | HandyPriors (optimization-based refinement) proposed | 3D Error | 3.79 cm | split: test · subset=S0; right-hand frames with hand-object contact | HandyPriors: Physically Consistent Perception of Hand-Object Interactions with Differentiable PriorsSource quoteL235: HandyPriors\xspace (ours) │ 1.67 │ 3.22 │ 0.96 │ 3.79 |
| 2023 | HandyPriors proposed | Joint (PA) error | 0.52 cm | split: test · subset=S0; right-hand frames with hand-object contact · alignment=Procrustes | HandyPriors: Physically Consistent Perception of Hand-Object Interactions with Differentiable PriorsSource quoteL204: HandyPriors\xspace (ours) │ 0.52 │ 0.81 │ 0.51 │ 0.89 │ 0.896 |
| 2023 | WSIM 3D Hand (Ours (Before)) ablation | Maximum Penetration Depth (M-PD) | 16.51 | split: test · subset=S0 · variant=before interaction refinement | Overcoming the TradeOff between Accuracy and Plausibility in 3D Hand Shape ReconstructionSource quoteL213: Ours (Before) │ 9.89 │ 1.00 │ 17.51 │ 9.12 │ 0.94 │ 16.51 |
| 2023 | HandOccNet baseline | E-PJ | 5.8 mm | split: test | DiffHand: End-to-End Hand Mesh Reconstruction via Diffusion ModelsSource quoteL188: HandOccNet~\cite{handoccnet} │ \textcolor{blue}{14.04} │ \textcolor{blue}{5.8} |
| 2023 | HandOccNet baseline | E_J | 14.04 mm | split: test | DiffHand: End-to-End Hand Mesh Reconstruction via Diffusion ModelsSource quoteL188: HandOccNet~\cite{handoccnet} │ \textcolor{blue}{14.04} │ \textcolor{blue}{5.8} |
| 2023 | MonoNHR baseline | Object F-score at 10mm threshold (F_o-10) | 0.32 | split: test · object=Banana · subset=novel objects · metric-threshold=10mm | HandNeRF: Learning to Reconstruct Hand-Object Interaction Scene from a Single RGB ImageSource quoteL494: MonoNHR │ 17.75 │ 0.47 │ 0.60 │ 0.35 │ 0.26 │ 0.51 │ 1.81 │ 0.17 │ 0.32 │ 259.45 │ 0.34 │ 0.67 │ 0.60 |
| 2023 | Artiboost baseline | 3D Error | 6.78 cm | split: test · subset=S0; right-hand frames with hand-object contact | HandyPriors: Physically Consistent Perception of Hand-Object Interactions with Differentiable PriorsSource quoteL232: Artiboost~\cite{yang2021ArtiBoost} │ 6.41 │ 10.83 │ 3.01 │ 6.78 |
| 2022 | PoseBERT on LCR-Net - Hand expert proposed | MPJPE | 29.21 mm | split: test · backbone=LCR-Net Hand expert · protocol=s0 | PoseBERT: A Generic Transformer Module for Temporal 3D Human ModelingSource quoteL690: + \bf{PoseBERT\xspace} │ \bf{29.21} \errorgain{17.1} │ \bf{6.88} \errorgain{9.27} │ \bf{4.52} \errorgain{28.92} |
| 2022 | PoseBERT on LCR-Net - Hand expert proposed | PA-MPJPE | 6.88 mm | split: test · backbone=LCR-Net Hand expert · protocol=s0 | PoseBERT: A Generic Transformer Module for Temporal 3D Human ModelingSource quoteL690: + \bf{PoseBERT\xspace} │ \bf{29.21} \errorgain{17.1} │ \bf{6.88} \errorgain{9.27} │ \bf{4.52} \errorgain{28.92} |
| 2022 | PoseBERT (HR-Net) proposed | MPJPE | 35.97 mm | split: test · backbone=HR-Net · protocol=s0 · observed-frames=15 · prediction-horizon=30 frames | PoseBERT: A Generic Transformer Module for Temporal 3D Human ModelingSource quoteL798: \bf{PoseBERT\xspace} │ \bf{35.97} │ \bf{6.99} │ \bf{61.64} │ \bf{9.32} |
| 2022 | LCR-Net - Hand expert baseline | MPJPE | 46.31 mm | split: test · model=LCR-Net Hand expert · protocol=s0 | PoseBERT: A Generic Transformer Module for Temporal 3D Human ModelingSource quoteL687: \color{green}{\checkmark} │ LCR-Net - Hand expert ~\cite{lcrnet++} │ 46.31 │ 16.15 │ 33.44 |
| 2022 | LCR-Net - Hand expert baseline | PA-MPJPE | 16.15 mm | split: test · model=LCR-Net Hand expert · protocol=s0 | PoseBERT: A Generic Transformer Module for Temporal 3D Human ModelingSource quoteL687: \color{green}{\checkmark} │ LCR-Net - Hand expert ~\cite{lcrnet++} │ 46.31 │ 16.15 │ 33.44 |
| 2022 | No-velocity baseline (HR-Net) baseline | MPJPE | 61.57 mm | split: test · backbone=HR-Net · protocol=s0 · observed-frames=15 · prediction-horizon=30 frames | PoseBERT: A Generic Transformer Module for Temporal 3D Human ModelingSource quoteL796: \multirow{4}{*}{\Delta t=30} │ No-velocity │ 61.57 │ 9.95 │ 69.01 │ 10.38 |
| 2022 | Hasson et al. (2021) baseline | MJE | 1.88 cm | split: test · subset=hand and object visible; hand-object distance <1 cm · split_variant=S0 | Interacting Hand-Object Pose Estimation via Dense Mutual AttentionSource quoteL275: Hasson \cite{hasson2021towards} │ 1.88 │ 5.25 │ 0.79 |
| 2021 | D-Grasp proposed | Success | 0.63 | split: test | D-Grasp: Physically Plausible Dynamic Grasp Synthesis for Hand-Object InteractionsSource quoteL678: 061 foam brick │ 16.0 ± 10.8 │ 0.29 │ 2.43 │ 10.0 ± 8.3 │ 0.13 │ 4.86 │ 10.5 ± 12.0 │ 0.57 │ 1.30 Average │ 13.1 ± 9.1 │ 0.35 │ 4.41 │ 9.1 ± 8.5 │ 0.50 │ 9.74 │ 8.0 ± 8.1 │ 0.63 │ 1.77 } |
| 2021 | GT+PD | Success | 0.35 | split: test | D-Grasp: Physically Plausible Dynamic Grasp Synthesis for Hand-Object InteractionsSource quoteL678: 061 foam brick │ 16.0 ± 10.8 │ 0.29 │ 2.43 │ 10.0 ± 8.3 │ 0.13 │ 4.86 │ 10.5 ± 12.0 │ 0.57 │ 1.30 Average │ 13.1 ± 9.1 │ 0.35 │ 4.41 │ 9.1 ± 8.5 │ 0.50 │ 9.74 │ 8.0 ± 8.1 │ 0.63 │ 1.77 } |
| 2021 | GT+PD | Interp. | 4.41 cm^3 | split: test | D-Grasp: Physically Plausible Dynamic Grasp Synthesis for Hand-Object InteractionsSource quoteL678: 061 foam brick │ 16.0 ± 10.8 │ 0.29 │ 2.43 │ 10.0 ± 8.3 │ 0.13 │ 4.86 │ 10.5 ± 12.0 │ 0.57 │ 1.30 Average │ 13.1 ± 9.1 │ 0.35 │ 4.41 │ 9.1 ± 8.5 │ 0.50 │ 9.74 │ 8.0 ± 8.1 │ 0.63 │ 1.77 } |