DexYCB

57 papers · 149 extracted observations · 3d hand pose estimation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=s0.

6.97.37.78.120232024IPNet (Depth &Point): 8.03 (2023)2-stages Keypoint-Fusion: 6.94 (2024)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 8 of 8 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025MaskHOI proposedMean Joint Error (MJE) ↓10.0split: s0 · fine-tuned · hand=rightMaskHOI: Robust 3D Hand-Object Interaction Estimation via Masked Pre-training
Source quote
L389: MaskHOI (ours) │ 10.0 │ 5.07 │ 16.7 │ 25.3 │ 12.3
2025MaskHOI proposedObject Center Error (OCE) ↓16.7split: s0 · fine-tuned · hand=rightMaskHOI: Robust 3D Hand-Object Interaction Estimation via Masked Pre-training
Source quote
L389: MaskHOI (ours) │ 10.0 │ 5.07 │ 16.7 │ 25.3 │ 12.3
2024HandDiff proposedMean joint error8.07 mminput=D+P · subset=average S0-S3HandDiff: 3D Hand Pose Estimation with Diffusion on Image-Point Cloud
Source quote
L188: Ours │ 7.66 │ 8.73 │ 8.40 │ 7.53 │ 8.07 │ D+P
2024HandDAGT proposedMean keypoint error8.03 mminput=D+P · split-aggregation=average across S0, S1, S2, and S3HandDAGT: A Denoising Adaptive Graph Transformer for 3D Hand Pose Estimation
Source quote
L190: HandDAGT (Ours) │ 7.72 │ 8.68 │ 8.22 │ 7.52 │ 8.03 │ D+P
2024GraspDiffusion full-body grasping-pose model (table label “Ours”) proposedPose Valid Error ↓0.111split: test · body-shapes=10 · novel-objects=10 · object-positions-per-pair=64GraspDiffusion: Synthesizing Realistic Whole-body Hand-Object Interaction
Source quote
L175: Ours │ 0.909 │ 0.111 │ 2.696
2023WSIM 3D Hand (Ours (GCN)) proposedEdge error distance0.25 mmsplit: test · subset=S0 · backbone=ResNet-50Overcoming the TradeOff between Accuracy and Plausibility in 3D Hand Shape Reconstruction
Source quote
L170: Ours (GCN) │ 7.42 │ 7.43 │ 0.51 │ 0.15 │ 9.68 │ 9.89 │ 0.27 │ 0.12 │ 8.92 │ 9.12 │ 0.25 │ 0.12
2023HandyPriors (optimization-based refinement) proposed3D Error3.79 cmsplit: test · subset=S0; right-hand frames with hand-object contactHandyPriors: Physically Consistent Perception of Hand-Object Interactions with Differentiable Priors
Source quote
L235: HandyPriors\xspace (ours) │ 1.67 │ 3.22 │ 0.96 │ 3.79
2023HandyPriors proposedJoint (PA) error0.52 cmsplit: test · subset=S0; right-hand frames with hand-object contact · alignment=ProcrustesHandyPriors: Physically Consistent Perception of Hand-Object Interactions with Differentiable Priors
Source quote
L204: HandyPriors\xspace (ours) │ 0.52 │ 0.81 │ 0.51 │ 0.89 │ 0.896