CT-RATE
53 papers · 152 extracted observations · report generation · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test, regime=fine-tuned.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | CT2Rep SOTA frontier | 0.534 | 2024-03-01 | labels=18 abnormalities · evaluator=fine-tuned CXR-BERT · Clinical efficacy from a fine-tuned CXR-Bert multi-label classifier over 18 abnormali… | CT2Rep: Automated Radiology Report Generation for 3D Medical ImagingSource quoteMean │ 0.513 │ 0.531 │ 0.456 │ 0.749 │ 0.548 │ 0.534 │ 0.186 |
| 2 | VividMed | 0.312 | 2025-01-01 | Report generation on the test set; evaluated without further fine-tuning on this data… | VividMed: Vision Language Model with Versatile Visual Grounding for MedicineSource quoteMacro RadBERT F1 │ 0.114 │ 0.112 │ 0.264 │ 0.312 |
Showing 7 of 7 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Med3D-R1 (S2; stage 2 RL) proposed | accuracy | 41.92% | split: val · training-stage=stage-2-RL · reasoning-instructions=enabled | Med3D-R1: Incentivizing Clinical Reasoning in 3D Medical Vision-Language Models for Abnormality DiagnosisSource quoteL236: 41.92 │ 40.30 │ 44.99 │ 43.75 |
| 2026 | SigVLP proposed non-standard slice | R@1 | 0.098 | split: val · candidates=1500 · report-input=reconstructed · volume-slices=200 | SigVLP: Sigmoid Volume-Language Pre-Training for Self-Supervised CT-Volume Adaptive Representation LearningSource quoteL542: Ours │ 0.098 │ 0.251 │ 0.336 │ 0.599 │ 0.730 │ 107.13 │ 0.180 |
| 2026 | SigVLP proposed non-standard slice | mAP | 0.180 | split: val · candidates=1500 · report-input=reconstructed · volume-slices=200 | SigVLP: Sigmoid Volume-Language Pre-Training for Self-Supervised CT-Volume Adaptive Representation LearningSource quoteL542: Ours │ 0.098 │ 0.251 │ 0.336 │ 0.599 │ 0.730 │ 107.13 │ 0.180 |
| 2026 | Proposed framework (Full, BERT) proposed | F1 | 0.320 | split: val · decoder=BERT · configuration=full | Structure Observation Driven Image-Text Contrastive Learning for Computed Tomography Report GenerationSource quoteL357: Full │ \checkmark │ \checkmark │ \checkmark │ \checkmark │ \checkmark │ 0.334 │ 0.356 │ 0.320 │ 0.509 │ 0.282 │ 0.277 │ 0.371 |
| 2025 | Ours (supervised-pretrained 3D ResNet-18 with vanilla CLIP training) proposed | AUC | 83.8% | split: val · 0-shot · backbone=3D ResNet-18 | More performant and scalable: Rethinking contrastive vision-language pre-training of radiology in the LLM eraSource quoteL173: Ours │ 83.8 │ 77.4 │ 79.6 │ 43.5 │ 77.3 │ 71.9 │ 74.8 │ 45.0 |
| 2025 | BrgSA proposed | AUC | 79.2 | split: val · 0-shot | Bridged Semantic Alignment for Zero-shot 3D Medical Image DiagnosisSource quoteL37: To explore the potential of our vision-language alignment approach for zero-shot diagnosis, we expand the original 18 abnormality labels on CT-RATE~\citep{hamamci2024foundation} with 15 additional labels. The new benchmark, referred to as ``CT-RATE-LT," focuses on underrepresented abnormalities with limited occurrences in the dataset, providing a challenging yet valuable testing ground for evaluating diagnostic methods. Experimental results on CT-RATE-LT demonstrate that our method achieves excellent performance in diagnosing underrepresented abnormalities, showing significant improvements compared to the existing state-of-the-art (SOTA) method (AUC: 76.9 vs. 85.6). Furthermore, we evaluate our method on the benchmark CT-RATE and RAD-ChestCT~\citep{draelos2021machine} datasets, achieving SOTA performances in zero-shot abnormality diagnosis, with an AUC of 79.2 and 70.0 on internal and external validation, respectively. In addition to its diagnostic capabilities, our method significantly outperforms the SOTA in the report-to-volume retrieval task (Recall@10: 5.0 vs. 10.1), demonstrating effective semantic alignment between image and text features. |
| 2024 | 3D-CT-GPT (T2 training strategy) proposed | BLEU | 0.1327 | split: val · training-strategy=T2 | 3D-CT-GPT: Generating 3D Radiology Reports through Integration of Large Vision-Language ModelsSource quoteL225: To evaluate generalization, we tested the T2-trained 3D-CT-GPT on the public dataset (CT-RATE\textsubscript{val}), where it continued to outperform M3D, with a BLEU of 0.1327 vs. 0.0299, ROUGE-1 of 0.2594 vs. 0.1164, and ROUGE-L of 0.1454 vs. 0.0781. The METEOR score also favored 3D-CT-GPT (0.1403 vs. 0.0549), highlighting its robustness and clinical potential. |