CT-RATE

53 papers · 152 extracted observations · report generation · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test, regime=fine-tuned.

0.30.40.50.620242025CT2Rep: 0.534 (2024)VividMed: 0.312 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 7 of 7 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Med3D-R1 (S2; stage 2 RL) proposedaccuracy41.92%split: val · training-stage=stage-2-RL · reasoning-instructions=enabledMed3D-R1: Incentivizing Clinical Reasoning in 3D Medical Vision-Language Models for Abnormality Diagnosis
Source quote
L236: 41.92 │ 40.30 │ 44.99 │ 43.75
2026SigVLP proposed non-standard sliceR@10.098split: val · candidates=1500 · report-input=reconstructed · volume-slices=200SigVLP: Sigmoid Volume-Language Pre-Training for Self-Supervised CT-Volume Adaptive Representation Learning
Source quote
L542: Ours │ 0.098 │ 0.251 │ 0.336 │ 0.599 │ 0.730 │ 107.13 │ 0.180
2026SigVLP proposed non-standard slicemAP0.180split: val · candidates=1500 · report-input=reconstructed · volume-slices=200SigVLP: Sigmoid Volume-Language Pre-Training for Self-Supervised CT-Volume Adaptive Representation Learning
Source quote
L542: Ours │ 0.098 │ 0.251 │ 0.336 │ 0.599 │ 0.730 │ 107.13 │ 0.180
2026Proposed framework (Full, BERT) proposedF10.320split: val · decoder=BERT · configuration=fullStructure Observation Driven Image-Text Contrastive Learning for Computed Tomography Report Generation
Source quote
L357: Full │ \checkmark │ \checkmark │ \checkmark │ \checkmark │ \checkmark │ 0.334 │ 0.356 │ 0.320 │ 0.509 │ 0.282 │ 0.277 │ 0.371
2025Ours (supervised-pretrained 3D ResNet-18 with vanilla CLIP training) proposedAUC83.8%split: val · 0-shot · backbone=3D ResNet-18More performant and scalable: Rethinking contrastive vision-language pre-training of radiology in the LLM era
Source quote
L173: Ours │ 83.8 │ 77.4 │ 79.6 │ 43.5 │ 77.3 │ 71.9 │ 74.8 │ 45.0
2025BrgSA proposedAUC79.2split: val · 0-shotBridged Semantic Alignment for Zero-shot 3D Medical Image Diagnosis
Source quote
L37: To explore the potential of our vision-language alignment approach for zero-shot diagnosis, we expand the original 18 abnormality labels on CT-RATE~\citep{hamamci2024foundation} with 15 additional labels. The new benchmark, referred to as ``CT-RATE-LT," focuses on underrepresented abnormalities with limited occurrences in the dataset, providing a challenging yet valuable testing ground for evaluating diagnostic methods. Experimental results on CT-RATE-LT demonstrate that our method achieves excellent performance in diagnosing underrepresented abnormalities, showing significant improvements compared to the existing state-of-the-art (SOTA) method (AUC: 76.9 vs. 85.6). Furthermore, we evaluate our method on the benchmark CT-RATE and RAD-ChestCT~\citep{draelos2021machine} datasets, achieving SOTA performances in zero-shot abnormality diagnosis, with an AUC of 79.2 and 70.0 on internal and external validation, respectively. In addition to its diagnostic capabilities, our method significantly outperforms the SOTA in the report-to-volume retrieval task (Recall@10: 5.0 vs. 10.1), demonstrating effective semantic alignment between image and text features.
20243D-CT-GPT (T2 training strategy) proposedBLEU0.1327split: val · training-strategy=T23D-CT-GPT: Generating 3D Radiology Reports through Integration of Large Vision-Language Models
Source quote
L225: To evaluate generalization, we tested the T2-trained 3D-CT-GPT on the public dataset (CT-RATE\textsubscript{val}), where it continued to outperform M3D, with a BLEU of 0.1327 vs. 0.0299, ROUGE-1 of 0.2594 vs. 0.1164, and ROUGE-L of 0.1454 vs. 0.0781. The METEOR score also favored 3D-CT-GPT (0.1403 vs. 0.0549), highlighting its robustness and clinical potential.