CT-RATE

53 papers · 152 extracted observations · report generation · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test, regime=fine-tuned.

0.30.40.50.620242025CT2Rep: 0.534 (2024)VividMed: 0.312 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 3 of 3 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025DCFormer-tiny proposedF1 score48.6%split: test · linear-probe · encoder=frozen · backbone=DCFormer-tinyDCFormer: Efficient 3D Vision-Language Modeling with Decomposed Convolutions
Source quote
L91: The DCFormer-tiny model achieves the highest F1 score at 48.6%, surpassing the best competing model (CTViT, 46.4%). DCFormer-naïve also achieves a strong F1 score of 47.2%, outperforming all other fine-tuned models. These gains highlight DCFormer's efficient and effective feature extraction when adapted to specific tasks.
2025CTViT baselineF1 score46.4%split: test · linear-probe · encoder=frozen · backbone=CTViTDCFormer: Efficient 3D Vision-Language Modeling with Decomposed Convolutions
Source quote
L91: The DCFormer-tiny model achieves the highest F1 score at 48.6%, surpassing the best competing model (CTViT, 46.4%). DCFormer-naïve also achieves a strong F1 score of 47.2%, outperforming all other fine-tuned models. These gains highlight DCFormer's efficient and effective feature extraction when adapted to specific tasks.
2025CT-CLIP (ClassFine) baselineMean AUC across 18 diseases0.768linear-probe · labels=18 diseases · backbone=CLIP · task-version=T11 · method-variant=ClassFineRevisiting 2D Foundation Models for Scalable 3D Medical Image Classification
Source quote
L213: Chest CT Multi-Abnormality (T11). We evaluate on chest CT multi-abnormality classification by using the CT-RATE dataset~\cite{hamamci2024foundation} and the official data split. We compare AnyMC3D (DINOv2) against CT-Net~\cite{draelos2021machine} (supervised baseline) and CT-CLIP~\cite{hamamci2024foundation} (vision-language FM for chest CT). As shown in Fig.~\ref{fig:ct_rate}, AnyMC3D (DINOv2) consistently outperforms both baselines across all 18 diseases, improving mean AUC from 0.631 (CT-Net) and 0.768 (CT-CLIP) to 0.882. We further validated AnyMC3D by attending the VLM3D challenge. With only about 0.5M trainable parameters, AnyMC3D won 1st place among 118 participants, beating other competing methods that performed expensive large-scale CT pretraining. This is a strong demonstration of AnyMC3D's generalizability, as challenge solutions are typically well-engineered and task-optimized.