CT-RATE

53 papers · 152 extracted observations · report generation · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test, regime=fine-tuned.

0.30.40.50.620242025CT2Rep: 0.534 (2024)VividMed: 0.312 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 10 of 10 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026MedGMAE proposedAUC76.40%fine-tunedMedGMAE: Gaussian Masked Autoencoders for Medical Volumetric Representation Learning
Source quote
L409: 76.40
2025µ2LLM-1B(SFT) proposedGREEN0.384fine-tuned · model=µ2LLM-1B · params=1B · training=SFTμ 2 Tokenizer: Differentiable Multi-Scale Multi-Modal Tokenizer for Radiology Report Generation
Source quote
L276: 0.384
2025µ2LLM-1B(SFT&DPO) proposedGREEN0.429fine-tuned · model=µ2LLM-1B · params=1B · training=SFT&DPOμ 2 Tokenizer: Differentiable Multi-Scale Multi-Modal Tokenizer for Radiology Report Generation
Source quote
L281: 0.429
2024CT2Rep proposedMean precision (P)0.749split: test · fine-tuned · labels=18 abnormalities · evaluator=fine-tuned CXR-BERTCT2Rep: Automated Radiology Report Generation for 3D Medical Imaging
Source quote
L193: Mean │ 0.513 │ 0.531 │ 0.456 │ 0.749 │ 0.548 │ 0.534 │ 0.186
2024CT2Rep proposedMean recall (R)0.548split: test · fine-tuned · labels=18 abnormalities · evaluator=fine-tuned CXR-BERTCT2Rep: Automated Radiology Report Generation for 3D Medical Imaging
Source quote
L193: Mean │ 0.513 │ 0.531 │ 0.456 │ 0.749 │ 0.548 │ 0.534 │ 0.186
2024CT2Rep proposedMean F1 score (F1)0.534split: test · fine-tuned · labels=18 abnormalities · evaluator=fine-tuned CXR-BERTCT2Rep: Automated Radiology Report Generation for 3D Medical Imaging
Source quote
L193: Mean │ 0.513 │ 0.531 │ 0.456 │ 0.749 │ 0.548 │ 0.534 │ 0.186
2024VividMed proposedMacro RadBERT F10.312split: test · fine-tunedVividMed: Vision Language Model with Versatile Visual Grounding for Medicine
Source quote
L340: Macro RadBERT F1 │ 0.114 │ 0.112 │ 0.264 │ 0.312
2024Base w/ CT-Net baselineMean precision (P)0.513split: test · fine-tuned · labels=18 abnormalities · evaluator=fine-tuned CXR-BERTCT2Rep: Automated Radiology Report Generation for 3D Medical Imaging
Source quote
L193: Mean │ 0.513 │ 0.531 │ 0.456 │ 0.749 │ 0.548 │ 0.534 │ 0.186
2024Base w/ CT-Net baselineMean recall (R)0.531split: test · fine-tuned · labels=18 abnormalities · evaluator=fine-tuned CXR-BERTCT2Rep: Automated Radiology Report Generation for 3D Medical Imaging
Source quote
L193: Mean │ 0.513 │ 0.531 │ 0.456 │ 0.749 │ 0.548 │ 0.534 │ 0.186
2024Base w/ CT-Net baselineMean F1 score (F1)0.456split: test · fine-tuned · labels=18 abnormalities · evaluator=fine-tuned CXR-BERTCT2Rep: Automated Radiology Report Generation for 3D Medical Imaging
Source quote
L193: Mean │ 0.513 │ 0.531 │ 0.456 │ 0.749 │ 0.548 │ 0.534 │ 0.186