CT-RATE

53 papers · 152 extracted observations · report generation · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test, regime=fine-tuned.

0.30.40.50.620242025CT2Rep: 0.534 (2024)VividMed: 0.312 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 6 of 6 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026ClefAUROC0.989split: val · 0-shotZero-shot evaluation of open vision-language models as System 1 decision models on radiology tasks
Source quote
L441: 0.989
2026Qwen3.8-27B baselineAUROC0.992split: val · 0-shot · params=27BZero-shot evaluation of open vision-language models as System 1 decision models on radiology tasks
Source quote
L433: 0.992
2026d1 3B baselineAUROC0.951split: val · 0-shot · params=3BZero-shot evaluation of open vision-language models as System 1 decision models on radiology tasks
Source quote
L449: 0.951
2025Ours (supervised-pretrained 3D ResNet-18 with vanilla CLIP training) proposedAUC83.8%split: val · 0-shot · backbone=3D ResNet-18More performant and scalable: Rethinking contrastive vision-language pre-training of radiology in the LLM era
Source quote
L173: Ours │ 83.8 │ 77.4 │ 79.6 │ 43.5 │ 77.3 │ 71.9 │ 74.8 │ 45.0
2025BrgSA proposedAUC79.2split: val · 0-shotBridged Semantic Alignment for Zero-shot 3D Medical Image Diagnosis
Source quote
L37: To explore the potential of our vision-language alignment approach for zero-shot diagnosis, we expand the original 18 abnormality labels on CT-RATE~\citep{hamamci2024foundation} with 15 additional labels. The new benchmark, referred to as ``CT-RATE-LT," focuses on underrepresented abnormalities with limited occurrences in the dataset, providing a challenging yet valuable testing ground for evaluating diagnostic methods. Experimental results on CT-RATE-LT demonstrate that our method achieves excellent performance in diagnosing underrepresented abnormalities, showing significant improvements compared to the existing state-of-the-art (SOTA) method (AUC: 76.9 vs. 85.6). Furthermore, we evaluate our method on the benchmark CT-RATE and RAD-ChestCT~\citep{draelos2021machine} datasets, achieving SOTA performances in zero-shot abnormality diagnosis, with an AUC of 79.2 and 70.0 on internal and external validation, respectively. In addition to its diagnostic capabilities, our method significantly outperforms the SOTA in the report-to-volume retrieval task (Recall@10: 5.0 vs. 10.1), demonstrating effective semantic alignment between image and text features.
2025BrgSA baselineAUC79.2%split: val · 0-shotMore performant and scalable: Rethinking contrastive vision-language pre-training of radiology in the LLM era
Source quote
L172: BrgSA │ 79.2 │ 73.3 │ 76.2 │ 38.5 │ 70.0 │ 65.5 │ 69.3 │ 39.1