CT-RATE
53 papers · 152 extracted observations · report generation · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test, regime=fine-tuned.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | CT2Rep SOTA frontier | 0.534 | 2024-03-01 | labels=18 abnormalities · evaluator=fine-tuned CXR-BERT · Clinical efficacy from a fine-tuned CXR-Bert multi-label classifier over 18 abnormali… | CT2Rep: Automated Radiology Report Generation for 3D Medical ImagingSource quoteMean │ 0.513 │ 0.531 │ 0.456 │ 0.749 │ 0.548 │ 0.534 │ 0.186 |
| 2 | VividMed | 0.312 | 2025-01-01 | Report generation on the test set; evaluated without further fine-tuning on this data… | VividMed: Vision Language Model with Versatile Visual Grounding for MedicineSource quoteMacro RadBERT F1 │ 0.114 │ 0.112 │ 0.264 │ 0.312 |
Showing 6 of 6 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Clef | AUROC | 0.989 | split: val · 0-shot | Zero-shot evaluation of open vision-language models as System 1 decision models on radiology tasksSource quoteL441: 0.989 |
| 2026 | Qwen3.8-27B baseline | AUROC | 0.992 | split: val · 0-shot · params=27B | Zero-shot evaluation of open vision-language models as System 1 decision models on radiology tasksSource quoteL433: 0.992 |
| 2026 | d1 3B baseline | AUROC | 0.951 | split: val · 0-shot · params=3B | Zero-shot evaluation of open vision-language models as System 1 decision models on radiology tasksSource quoteL449: 0.951 |
| 2025 | Ours (supervised-pretrained 3D ResNet-18 with vanilla CLIP training) proposed | AUC | 83.8% | split: val · 0-shot · backbone=3D ResNet-18 | More performant and scalable: Rethinking contrastive vision-language pre-training of radiology in the LLM eraSource quoteL173: Ours │ 83.8 │ 77.4 │ 79.6 │ 43.5 │ 77.3 │ 71.9 │ 74.8 │ 45.0 |
| 2025 | BrgSA proposed | AUC | 79.2 | split: val · 0-shot | Bridged Semantic Alignment for Zero-shot 3D Medical Image DiagnosisSource quoteL37: To explore the potential of our vision-language alignment approach for zero-shot diagnosis, we expand the original 18 abnormality labels on CT-RATE~\citep{hamamci2024foundation} with 15 additional labels. The new benchmark, referred to as ``CT-RATE-LT," focuses on underrepresented abnormalities with limited occurrences in the dataset, providing a challenging yet valuable testing ground for evaluating diagnostic methods. Experimental results on CT-RATE-LT demonstrate that our method achieves excellent performance in diagnosing underrepresented abnormalities, showing significant improvements compared to the existing state-of-the-art (SOTA) method (AUC: 76.9 vs. 85.6). Furthermore, we evaluate our method on the benchmark CT-RATE and RAD-ChestCT~\citep{draelos2021machine} datasets, achieving SOTA performances in zero-shot abnormality diagnosis, with an AUC of 79.2 and 70.0 on internal and external validation, respectively. In addition to its diagnostic capabilities, our method significantly outperforms the SOTA in the report-to-volume retrieval task (Recall@10: 5.0 vs. 10.1), demonstrating effective semantic alignment between image and text features. |
| 2025 | BrgSA baseline | AUC | 79.2% | split: val · 0-shot | More performant and scalable: Rethinking contrastive vision-language pre-training of radiology in the LLM eraSource quoteL172: BrgSA │ 79.2 │ 73.3 │ 76.2 │ 38.5 │ 70.0 │ 65.5 │ 69.3 │ 39.1 |