CT-RATE

53 papers · 152 extracted observations · report generation · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test, regime=fine-tuned.

0.30.40.50.620242025CT2Rep: 0.534 (2024)VividMed: 0.312 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 8 of 8 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026MedGemma 1.5 4B proposedMacro F126.90-shot · params=4B · modality=3D CT · queries-per-condition=18MedGemma 1.5 Technical Report
Source quote
L443: CT-RATE^* (3D CT) │ Macro F1 │ 23.5 │ 26.9 │ 8.5
2025DCFormer-naïve proposedF1 score44.5%0-shot · resolution=512×512×256DCFormer: Efficient 3D Vision-Language Modeling with Decomposed Convolutions
Source quote
L67: Table \ref{results} compares the zero-shot performance and computational efficiency of multiple models on the CT-RATE dataset (image volume size 512×512×256). DCFormer provides a family of models with configurations ranging from nano to tiny variants. Across all configurations, the lightweight variants of DCFormer consistently achieve superior results while reducing computational overhead. For instance, the nano variant of DCFormer achieves higher F1 score, precision, and recall than the corresponding nano variants of ConvNeXt and PoolFormer. Similarly, the naïve variant of DCFormer achieves a higher F1 score than the naïve variants of ConvNeXt, PoolFormer, and TransUNet. Notably, DCFormer achieves these results with significantly improved computational efficiency. For example, the naïve variant of DCFormer delivers a 44.5% F1 score—outperforming CT-ViT as well as the tiny variants of ConvNeXt, PoolFormer, and TransUNet—while using substantially fewer parameters and FLOPs: 5.85 million parameters and 49.48 GFLOPs, compared to CT-ViT’s 101.1 million parameters and 160.5 GFLOPs. DCFormer’s ability to outperform state-of-the-art models with far fewer computational resources underscores its potential for applications demanding both high performance and efficiency.
2025Ours (supervised-pretrained 3D ResNet-18 with vanilla CLIP training) proposedAUC83.8%split: val · 0-shot · backbone=3D ResNet-18More performant and scalable: Rethinking contrastive vision-language pre-training of radiology in the LLM era
Source quote
L173: Ours │ 83.8 │ 77.4 │ 79.6 │ 43.5 │ 77.3 │ 71.9 │ 74.8 │ 45.0
2025MedVista3D-UniMISS proposedAUC0.7820-shot · scope=globalMedVista3D: Vision-Language Modeling for Reducing Diagnostic Errors in 3D CT Disease Detection, Understanding and Reporting
Source quote
L268: Results for global tasks. Both MedVista3D-ViT and MedVista3D-UniMISS outperform all global models in disease zero-shot and report retrieval (Table \ref{tab:compare_CTRATE_table}). For global disease zero-shot, MedVista3D-UniMISS achieves the highest AUC (0.782) and F1 (0.770), outperforming CT-CLIP by 7.4 points in AUC and 6.9 points in F1. For report retrieval, MedVista3D-ViT surpasses CT-CLIP by 4.3% and 6.7% in top-5 and top-10 recall. These results validate our model’s ability to jointly reduce inattentional blindness and under-reading errors.
2025MedVista3D-UniMISS proposedF10.7700-shot · scope=globalMedVista3D: Vision-Language Modeling for Reducing Diagnostic Errors in 3D CT Disease Detection, Understanding and Reporting
Source quote
L268: Results for global tasks. Both MedVista3D-ViT and MedVista3D-UniMISS outperform all global models in disease zero-shot and report retrieval (Table \ref{tab:compare_CTRATE_table}). For global disease zero-shot, MedVista3D-UniMISS achieves the highest AUC (0.782) and F1 (0.770), outperforming CT-CLIP by 7.4 points in AUC and 6.9 points in F1. For report retrieval, MedVista3D-ViT surpasses CT-CLIP by 4.3% and 6.7% in top-5 and top-10 recall. These results validate our model’s ability to jointly reduce inattentional blindness and under-reading errors.
2025SCALE-VLP proposedPericardial effusion accuracy0.670-shot · finding=pericardial effusionSCALE-VLP: Soft-Weighted Contrastive Volumetric Vision-Language Pre-training with Spatial-Knowledge Semantics
Source quote
L508: Pericardial effusion │ 0.08 │ 0.08 │ 0.08 │ 0.08 │ 0.54 │ 0.14 │ 0.67
2025BrgSA proposedAUC79.2split: val · 0-shotBridged Semantic Alignment for Zero-shot 3D Medical Image Diagnosis
Source quote
L37: To explore the potential of our vision-language alignment approach for zero-shot diagnosis, we expand the original 18 abnormality labels on CT-RATE~\citep{hamamci2024foundation} with 15 additional labels. The new benchmark, referred to as ``CT-RATE-LT," focuses on underrepresented abnormalities with limited occurrences in the dataset, providing a challenging yet valuable testing ground for evaluating diagnostic methods. Experimental results on CT-RATE-LT demonstrate that our method achieves excellent performance in diagnosing underrepresented abnormalities, showing significant improvements compared to the existing state-of-the-art (SOTA) method (AUC: 76.9 vs. 85.6). Furthermore, we evaluate our method on the benchmark CT-RATE and RAD-ChestCT~\citep{draelos2021machine} datasets, achieving SOTA performances in zero-shot abnormality diagnosis, with an AUC of 79.2 and 70.0 on internal and external validation, respectively. In addition to its diagnostic capabilities, our method significantly outperforms the SOTA in the report-to-volume retrieval task (Recall@10: 5.0 vs. 10.1), demonstrating effective semantic alignment between image and text features.
2025COLIPRI-C proposedAUROC77.800-shot · prompt=native · prompt-source=long-findings-reportsComprehensive language-image pre-training for 3D medical image understanding
Source quote
L1028: {COLIPRI-C\xspace} │ native │ 44.31 │ 77.80 │ 70.15 │ 48.88 │ 75.20 │ 39.79 │ 66.98 │ 60.94 │ 45.65 │ 65.73