CT-RATE
53 papers · 152 extracted observations · report generation · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test, regime=fine-tuned.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | CT2Rep SOTA frontier | 0.534 | 2024-03-01 | labels=18 abnormalities · evaluator=fine-tuned CXR-BERT · Clinical efficacy from a fine-tuned CXR-Bert multi-label classifier over 18 abnormali… | CT2Rep: Automated Radiology Report Generation for 3D Medical ImagingSource quoteMean │ 0.513 │ 0.531 │ 0.456 │ 0.749 │ 0.548 │ 0.534 │ 0.186 |
| 2 | VividMed | 0.312 | 2025-01-01 | Report generation on the test set; evaluated without further fine-tuning on this data… | VividMed: Vision Language Model with Versatile Visual Grounding for MedicineSource quoteMacro RadBERT F1 │ 0.114 │ 0.112 │ 0.264 │ 0.312 |
Showing 4 of 4 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | RAG-Nearest proposed | FID 3D | 0.004 | Computed with a 3D feature extractor; lower is better. | Retrieval-Augmented Anatomical Guidance for Text-to-CT GenerationSource quoteL182: RAG-Nearest │ 0.275 │ 0.317 │ 0.318 │ 0.303 │ 0.004 |
| 2025 | TRACE (3D) proposed | FID ↓ | 98.6 | split: test · output=3D · patient-split=unseen patients · training-subset=100 randomly selected CT volumes | TRACE: Temporally Reliable Anatomically-Conditioned 3D CT Generation with Enhanced EfficiencySource quoteL246: Ours │ 3D │ 98.6 │ 1176.7 │ 29.4 |
| 2025 | BTB3D 8×8×8 proposed | mean FID | 2.24 | subset=100 randomly selected volumes · variant=8×8×8 compression · evaluation=central 40% of slices in each anatomical plane · metric-backbone=RadImageNet-pretrained ResNet50 | Better Tokens for Better 3D: Advancing Vision-Language Modeling in 3D Medical ImagingSource quoteL591: Quantitative results reported in the main paper (Table 4) show that our BTB3D framework with the lower compression variant (8×8×8) achieves the best overall performance across all generative metrics. Specifically, it reduces the mean Fréchet Inception Distance (FID) from 9.51 (GenerateCT) and 12.59 (MedSyn) to just 2.24, a 76.5% improvement, demonstrating superior fidelity. We compute FID using the \texttt{FIDMetric} from the MONAI library~\cite{cardoso2022monai}, leveraging a RadImageNet-pretrained ResNet50 backbone~\cite{radimagenet}, which is better suited for grayscale radiology images than traditional Inception networks. Following standard practice established by GenerateCT and MAISI~\cite{guo2025maisi}, FID is calculated on the central 40% of slices (in each anatomical plane) across 100 randomly selected volumes per method, reducing boundary noise and focusing on clinically relevant regions. |
| 2025 | Text2CT (T5-Base, Proposed prompt formulation) proposed | FID (Avg.) | 0.65 | text-encoder=T5-Base · prompt-formulation=proposed | Text2CT: Towards 3D CT Volume Generation from Free-text Descriptions Using Diffusion ModelSource quoteL190: T5-Base │ Proposed │ 0.65 │ 27.82 |