CT-RATE
53 papers · 152 extracted observations · report generation · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test, regime=fine-tuned.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | CT2Rep SOTA frontier | 0.534 | 2024-03-01 | labels=18 abnormalities · evaluator=fine-tuned CXR-BERT · Clinical efficacy from a fine-tuned CXR-Bert multi-label classifier over 18 abnormali… | CT2Rep: Automated Radiology Report Generation for 3D Medical ImagingSource quoteMean │ 0.513 │ 0.531 │ 0.456 │ 0.749 │ 0.548 │ 0.534 │ 0.186 |
| 2 | VividMed | 0.312 | 2025-01-01 | Report generation on the test set; evaluated without further fine-tuning on this data… | VividMed: Vision Language Model with Versatile Visual Grounding for MedicineSource quoteMacro RadBERT F1 │ 0.114 │ 0.112 │ 0.264 │ 0.312 |
Showing 27 of 27 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | nnFoundation ViT proposed | F1 score | 43.7 | frozen-encoder · encoder=frozen image encoder · training=adapter and language model trained · configuration=best learning-rate and field-of-view | nnFoundation: 3D Foundation Models for RadiologySource quoteL97: In image-to-image retrieval (\cref{fig2}d), \Name{vit} achieved the best mean ranking, placing first or second on every dataset, with Merlin showing comparable performance. For report generation (\cref{fig2}c), \Name{vit} achieved the best overall performance across both datasets. On CT-RATE, it achieved a F1 score of 43.7 compared with 42.8 for the next-best method, CURIA. Notably, \Name{vit} is also competitive to Merlin on the MERLIN dataset itself, despite Merlin having been trained on this data, achieving a bilingual evaluation understudy (BLEU) score of 0.172 compared with 0.170. |
| 2026 | CCP-10 + corpus template proposed | F1RadBERT-CT micro-F1 | 0.549 | split: test · method=CCP-10 + corpus template | Sparse Concept Channels in Frozen 3D CT Vision EncodersSource quoteL470: on both metrics (F1 0.549, BLEU-1 0.483) at \sim23× lower latency. |
| 2026 | MedGemma 1.5 4B proposed | Macro F1 | 26.9 | 0-shot · params=4B · modality=3D CT · queries-per-condition=18 | MedGemma 1.5 Technical ReportSource quoteL443: CT-RATE^* (3D CT) │ Macro F1 │ 23.5 │ 26.9 │ 8.5 |
| 2026 | Proposed framework (Full, BERT) proposed | F1 | 0.320 | split: val · decoder=BERT · configuration=full | Structure Observation Driven Image-Text Contrastive Learning for Computed Tomography Report GenerationSource quoteL357: Full │ \checkmark │ \checkmark │ \checkmark │ \checkmark │ \checkmark │ 0.334 │ 0.356 │ 0.320 │ 0.509 │ 0.282 │ 0.277 │ 0.371 |
| 2026 | NV-REASON-CT proposed | Macro-F1 (positive-class, report-derived) | 0.592 | aggregation=macro-positive-class-f1 · prediction-source=generated-reports | NV-Reason-CT: 3D Visual Language Model for CT AnalysisSource quoteL2548: 0.432 │ 0.365 │ 0.592 |
| 2026 | ClinFusion-32B (standalone) proposed | F1 | 23.9 | params=32B · modality=3D non-contrast chest CT · evaluation=RoI-grounded | ClinFusion: A Vision-Centric Multimodal LLM System for Holistic Medical UnderstandingSource quoteL1542: ClinFusion\xspace-32B │ 81.7 │ 79.1 │ 36.2 │ 89.0 │ 62.1 │ 26.7 │ 13.7 │ 16.1 │ 34.5 │ 21.4 │ 23.9 |
| 2026 | MedScribe-Template ablation | F1-score | 0.32 | setting=template-based | MedScribe: Clinically Grounded CT Reporting through Agentic WorkflowsSource quoteL113: Ours │ 0.36 │ 0.33 │ 0.32 │ 0.34 │ 0.18 │ 0.34 │ 0.12 │ 0.59 |
| 2026 | MedScribe-Template (NO RAG) ablation | F1-score | 0.24 | setting=template-based · component=no RAG | MedScribe: Clinically Grounded CT Reporting through Agentic WorkflowsSource quoteL114: Ours (NO RAG) │ 0.18 │ 0.60 │ 0.24 │ 0.21 │ 0.12 │ 0.28 │ 0.08 │ 0.56 |
| 2026 | Backbone baseline (ablation config. a) ablation | F1 | 0.124 | split: val · decoder=BERT · configuration=report-generation-loss-only | Structure Observation Driven Image-Text Contrastive Learning for Computed Tomography Report GenerationSource quoteL353: (a) │ × │ × │ × │ \checkmark │ × │ 0.221 │ 0.115 │ 0.124 │ 0.511 │ 0.286 │ 0.272 │ 0.374 |
| 2026 | CURIA baseline | F1 score | 42.8 | Report generation; comparator to nnFoundation ViT under the report-generation evaluation. | nnFoundation: 3D Foundation Models for RadiologySource quoteL97: In image-to-image retrieval (\cref{fig2}d), \Name{vit} achieved the best mean ranking, placing first or second on every dataset, with Merlin showing comparable performance. For report generation (\cref{fig2}c), \Name{vit} achieved the best overall performance across both datasets. On CT-RATE, it achieved a F1 score of 43.7 compared with 42.8 for the next-best method, CURIA. Notably, \Name{vit} is also competitive to Merlin on the MERLIN dataset itself, despite Merlin having been trained on this data, achieving a bilingual evaluation understudy (BLEU) score of 0.172 compared with 0.170. |
| 2026 | CT-CHAT baseline | F1RadBERT-CT micro-F1 | 0.184 | split: test · model=CT-CHAT | Sparse Concept Channels in Frozen 3D CT Vision EncodersSource quoteL468: failure modes. CT-CHAT achieves BLEU-1 0.373 but F1 only 0.184, drifting |
| 2026 | MedGemma 1 4B baseline | Macro F1 | 23.5 | 0-shot · params=4B · modality=3D CT · queries-per-condition=18 | MedGemma 1.5 Technical ReportSource quoteL443: CT-RATE^* (3D CT) │ Macro F1 │ 23.5 │ 26.9 │ 8.5 |
| 2026 | Gemini 3.0 Flash baseline non-standard slice | Macro F1 | 8.5 | subset=representative subset · modality=3D CT · queries-per-condition=18 | MedGemma 1.5 Technical ReportSource quoteL443: CT-RATE^* (3D CT) │ Macro F1 │ 23.5 │ 26.9 │ 8.5 |
| 2025 | DCFormer-naïve proposed | F1 score | 44.5% | 0-shot · resolution=512×512×256 | DCFormer: Efficient 3D Vision-Language Modeling with Decomposed ConvolutionsSource quoteL67: Table \ref{results} compares the zero-shot performance and computational efficiency of multiple models on the CT-RATE dataset (image volume size 512×512×256). DCFormer provides a family of models with configurations ranging from nano to tiny variants. Across all configurations, the lightweight variants of DCFormer consistently achieve superior results while reducing computational overhead. For instance, the nano variant of DCFormer achieves higher F1 score, precision, and recall than the corresponding nano variants of ConvNeXt and PoolFormer. Similarly, the naïve variant of DCFormer achieves a higher F1 score than the naïve variants of ConvNeXt, PoolFormer, and TransUNet. Notably, DCFormer achieves these results with significantly improved computational efficiency. For example, the naïve variant of DCFormer delivers a 44.5% F1 score—outperforming CT-ViT as well as the tiny variants of ConvNeXt, PoolFormer, and TransUNet—while using substantially fewer parameters and FLOPs: 5.85 million parameters and 49.48 GFLOPs, compared to CT-ViT’s 101.1 million parameters and 160.5 GFLOPs. DCFormer’s ability to outperform state-of-the-art models with far fewer computational resources underscores its potential for applications demanding both high performance and efficiency. |
| 2025 | DCFormer-tiny proposed | F1 score | 48.6% | split: test · linear-probe · encoder=frozen · backbone=DCFormer-tiny | DCFormer: Efficient 3D Vision-Language Modeling with Decomposed ConvolutionsSource quoteL91: The DCFormer-tiny model achieves the highest F1 score at 48.6%, surpassing the best competing model (CTViT, 46.4%). DCFormer-naïve also achieves a strong F1 score of 47.2%, outperforming all other fine-tuned models. These gains highlight DCFormer's efficient and effective feature extraction when adapted to specific tasks. |
| 2025 | CT-GRAPH proposed | CE F1 | 0.296 | features=VoCo-160k | CT-GRAPH: Hierarchical Graph Attention Network for Anatomy-Guided CT Report GenerationSource quoteL269: CT-GRAPH │ 0.4850 │ 0.3765 │ 0.3024 │ 0.2467 │ 0.3126 │ 0.4205 │ 0.396 │ 0.248 │ 0.296 |
| 2025 | MedVista3D-UniMISS proposed | F1 | 0.770 | 0-shot · scope=global | MedVista3D: Vision-Language Modeling for Reducing Diagnostic Errors in 3D CT Disease Detection, Understanding and ReportingSource quoteL268: Results for global tasks. Both MedVista3D-ViT and MedVista3D-UniMISS outperform all global models in disease zero-shot and report retrieval (Table \ref{tab:compare_CTRATE_table}). For global disease zero-shot, MedVista3D-UniMISS achieves the highest AUC (0.782) and F1 (0.770), outperforming CT-CLIP by 7.4 points in AUC and 6.9 points in F1. For report retrieval, MedVista3D-ViT surpasses CT-CLIP by 4.3% and 6.7% in top-5 and top-10 recall. These results validate our model’s ability to jointly reduce inattentional blindness and under-reading errors. |
| 2025 | MedFormer (Gao et al.) + SMILE proposed | F1-score | 71.4 | scan-type=external non-contrast CT · cohort-size=N=74 · preprocessing=SMILE | See More, Change Less: Anatomy-Aware Diffusion for Contrast EnhancementSource quoteL399: 69.2 │ 91.8 │ 71.4 │ 0.84 |
| 2025 | Global + Local ablation | CE F1 | 0.245 | features=VoCo-160k | CT-GRAPH: Hierarchical Graph Attention Network for Anatomy-Guided CT Report GenerationSource quoteL266: Global + Local │ 0.4751 │ 0.3702 │ 0.2986 │ 0.2446 │ 0.3089 │ 0.4159 │ 0.343 │ 0.201 │ 0.245 |
| 2025 | Single-Level hierarchy graph ablation | CE F1 | 0.253 | features=VoCo-160k | CT-GRAPH: Hierarchical Graph Attention Network for Anatomy-Guided CT Report GenerationSource quoteL268: Single-Level hierarchy graph │ 0.4743 │ 0.3651 │ 0.2914 │ 0.2360 │ 0.3060 │ 0.4097 │ 0.385 │ 0.202 │ 0.253 |
| 2025 | CTViT baseline | F1 score | 46.4% | split: test · linear-probe · encoder=frozen · backbone=CTViT | DCFormer: Efficient 3D Vision-Language Modeling with Decomposed ConvolutionsSource quoteL91: The DCFormer-tiny model achieves the highest F1 score at 48.6%, surpassing the best competing model (CTViT, 46.4%). DCFormer-naïve also achieves a strong F1 score of 47.2%, outperforming all other fine-tuned models. These gains highlight DCFormer's efficient and effective feature extraction when adapted to specific tasks. |
| 2025 | MedFormer (Gao et al.) baseline | F1-score | 60.9 | scan-type=external non-contrast CT · cohort-size=N=74 | See More, Change Less: Anatomy-Aware Diffusion for Contrast EnhancementSource quoteL395: 53.9 │ 95.1 │ 60.9 │ 0.75 |
| 2024 | CT2Rep proposed | Mean F1 score (F1) | 0.534 | split: test · fine-tuned · labels=18 abnormalities · evaluator=fine-tuned CXR-BERT | CT2Rep: Automated Radiology Report Generation for 3D Medical ImagingSource quoteL193: Mean │ 0.513 │ 0.531 │ 0.456 │ 0.749 │ 0.548 │ 0.534 │ 0.186 |
| 2024 | VividMed proposed | Macro RadBERT F1 | 0.312 | split: test · fine-tuned | VividMed: Vision Language Model with Versatile Visual Grounding for MedicineSource quoteL340: Macro RadBERT F1 │ 0.114 │ 0.112 │ 0.264 │ 0.312 |
| 2024 | E3D-GPT proposed | BERT-F1 | 93.84 | Report-generation text evaluation; BERT-F1 is the semantic text-generation metric. Spli… | E3D-GPT: Enhanced 3D Visual Foundation for Medical Vision-Language ModelSource quoteL163: E3D-GPT │ 42.24 │ 47.25 │ 41.74 │ 92.10 │ 51.99 │ 57.05 │ 53.52 │ 93.84 |
| 2024 | VividMed w/o VG ablation | Macro RadBERT F1 | 0.264 | split: test | VividMed: Vision Language Model with Versatile Visual Grounding for MedicineSource quoteL340: Macro RadBERT F1 │ 0.114 │ 0.112 │ 0.264 │ 0.312 |
| 2024 | Base w/ CT-Net baseline | Mean F1 score (F1) | 0.456 | split: test · fine-tuned · labels=18 abnormalities · evaluator=fine-tuned CXR-BERT | CT2Rep: Automated Radiology Report Generation for 3D Medical ImagingSource quoteL193: Mean │ 0.513 │ 0.531 │ 0.456 │ 0.749 │ 0.548 │ 0.534 │ 0.186 |