CT-RATE
53 papers · 152 extracted observations · report generation · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test, regime=fine-tuned.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | CT2Rep SOTA frontier | 0.534 | 2024-03-01 | labels=18 abnormalities · evaluator=fine-tuned CXR-BERT · Clinical efficacy from a fine-tuned CXR-Bert multi-label classifier over 18 abnormali… | CT2Rep: Automated Radiology Report Generation for 3D Medical ImagingSource quoteMean │ 0.513 │ 0.531 │ 0.456 │ 0.749 │ 0.548 │ 0.534 │ 0.186 |
| 2 | VividMed | 0.312 | 2025-01-01 | Report generation on the test set; evaluated without further fine-tuning on this data… | VividMed: Vision Language Model with Versatile Visual Grounding for MedicineSource quoteMacro RadBERT F1 │ 0.114 │ 0.112 │ 0.264 │ 0.312 |
Showing 8 of 8 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | CCP-10 + corpus template proposed | F1RadBERT-CT micro-F1 | 0.549 | split: test · method=CCP-10 + corpus template | Sparse Concept Channels in Frozen 3D CT Vision EncodersSource quoteL470: on both metrics (F1 0.549, BLEU-1 0.483) at \sim23× lower latency. |
| 2026 | CT-CHAT baseline | F1RadBERT-CT micro-F1 | 0.184 | split: test · model=CT-CHAT | Sparse Concept Channels in Frozen 3D CT Vision EncodersSource quoteL468: failure modes. CT-CHAT achieves BLEU-1 0.373 but F1 only 0.184, drifting |
| 2025 | DCFormer-tiny proposed | F1 score | 48.6% | split: test · linear-probe · encoder=frozen · backbone=DCFormer-tiny | DCFormer: Efficient 3D Vision-Language Modeling with Decomposed ConvolutionsSource quoteL91: The DCFormer-tiny model achieves the highest F1 score at 48.6%, surpassing the best competing model (CTViT, 46.4%). DCFormer-naïve also achieves a strong F1 score of 47.2%, outperforming all other fine-tuned models. These gains highlight DCFormer's efficient and effective feature extraction when adapted to specific tasks. |
| 2025 | CTViT baseline | F1 score | 46.4% | split: test · linear-probe · encoder=frozen · backbone=CTViT | DCFormer: Efficient 3D Vision-Language Modeling with Decomposed ConvolutionsSource quoteL91: The DCFormer-tiny model achieves the highest F1 score at 48.6%, surpassing the best competing model (CTViT, 46.4%). DCFormer-naïve also achieves a strong F1 score of 47.2%, outperforming all other fine-tuned models. These gains highlight DCFormer's efficient and effective feature extraction when adapted to specific tasks. |
| 2024 | CT2Rep proposed | Mean F1 score (F1) | 0.534 | split: test · fine-tuned · labels=18 abnormalities · evaluator=fine-tuned CXR-BERT | CT2Rep: Automated Radiology Report Generation for 3D Medical ImagingSource quoteL193: Mean │ 0.513 │ 0.531 │ 0.456 │ 0.749 │ 0.548 │ 0.534 │ 0.186 |
| 2024 | VividMed proposed | Macro RadBERT F1 | 0.312 | split: test · fine-tuned | VividMed: Vision Language Model with Versatile Visual Grounding for MedicineSource quoteL340: Macro RadBERT F1 │ 0.114 │ 0.112 │ 0.264 │ 0.312 |
| 2024 | VividMed w/o VG ablation | Macro RadBERT F1 | 0.264 | split: test | VividMed: Vision Language Model with Versatile Visual Grounding for MedicineSource quoteL340: Macro RadBERT F1 │ 0.114 │ 0.112 │ 0.264 │ 0.312 |
| 2024 | Base w/ CT-Net baseline | Mean F1 score (F1) | 0.456 | split: test · fine-tuned · labels=18 abnormalities · evaluator=fine-tuned CXR-BERT | CT2Rep: Automated Radiology Report Generation for 3D Medical ImagingSource quoteL193: Mean │ 0.513 │ 0.531 │ 0.456 │ 0.749 │ 0.548 │ 0.534 │ 0.186 |