CT-RATE

53 papers · 152 extracted observations · report generation · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test, regime=fine-tuned.

0.30.40.50.620242025CT2Rep: 0.534 (2024)VividMed: 0.312 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 8 of 8 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026CCP-10 + corpus template proposedF1RadBERT-CT micro-F10.549split: test · method=CCP-10 + corpus templateSparse Concept Channels in Frozen 3D CT Vision Encoders
Source quote
L470: on both metrics (F1 0.549, BLEU-1 0.483) at \sim23× lower latency.
2026CT-CHAT baselineF1RadBERT-CT micro-F10.184split: test · model=CT-CHATSparse Concept Channels in Frozen 3D CT Vision Encoders
Source quote
L468: failure modes. CT-CHAT achieves BLEU-1 0.373 but F1 only 0.184, drifting
2025DCFormer-tiny proposedF1 score48.6%split: test · linear-probe · encoder=frozen · backbone=DCFormer-tinyDCFormer: Efficient 3D Vision-Language Modeling with Decomposed Convolutions
Source quote
L91: The DCFormer-tiny model achieves the highest F1 score at 48.6%, surpassing the best competing model (CTViT, 46.4%). DCFormer-naïve also achieves a strong F1 score of 47.2%, outperforming all other fine-tuned models. These gains highlight DCFormer's efficient and effective feature extraction when adapted to specific tasks.
2025CTViT baselineF1 score46.4%split: test · linear-probe · encoder=frozen · backbone=CTViTDCFormer: Efficient 3D Vision-Language Modeling with Decomposed Convolutions
Source quote
L91: The DCFormer-tiny model achieves the highest F1 score at 48.6%, surpassing the best competing model (CTViT, 46.4%). DCFormer-naïve also achieves a strong F1 score of 47.2%, outperforming all other fine-tuned models. These gains highlight DCFormer's efficient and effective feature extraction when adapted to specific tasks.
2024CT2Rep proposedMean F1 score (F1)0.534split: test · fine-tuned · labels=18 abnormalities · evaluator=fine-tuned CXR-BERTCT2Rep: Automated Radiology Report Generation for 3D Medical Imaging
Source quote
L193: Mean │ 0.513 │ 0.531 │ 0.456 │ 0.749 │ 0.548 │ 0.534 │ 0.186
2024VividMed proposedMacro RadBERT F10.312split: test · fine-tunedVividMed: Vision Language Model with Versatile Visual Grounding for Medicine
Source quote
L340: Macro RadBERT F1 │ 0.114 │ 0.112 │ 0.264 │ 0.312
2024VividMed w/o VG ablationMacro RadBERT F10.264split: testVividMed: Vision Language Model with Versatile Visual Grounding for Medicine
Source quote
L340: Macro RadBERT F1 │ 0.114 │ 0.112 │ 0.264 │ 0.312
2024Base w/ CT-Net baselineMean F1 score (F1)0.456split: test · fine-tuned · labels=18 abnormalities · evaluator=fine-tuned CXR-BERTCT2Rep: Automated Radiology Report Generation for 3D Medical Imaging
Source quote
L193: Mean │ 0.513 │ 0.531 │ 0.456 │ 0.749 │ 0.548 │ 0.534 │ 0.186