CT-RATE
53 papers · 152 extracted observations · report generation · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test, regime=fine-tuned.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | CT2Rep SOTA frontier | 0.534 | 2024-03-01 | labels=18 abnormalities · evaluator=fine-tuned CXR-BERT · Clinical efficacy from a fine-tuned CXR-Bert multi-label classifier over 18 abnormali… | CT2Rep: Automated Radiology Report Generation for 3D Medical ImagingSource quoteMean │ 0.513 │ 0.531 │ 0.456 │ 0.749 │ 0.548 │ 0.534 │ 0.186 |
| 2 | VividMed | 0.312 | 2025-01-01 | Report generation on the test set; evaluated without further fine-tuning on this data… | VividMed: Vision Language Model with Versatile Visual Grounding for MedicineSource quoteMacro RadBERT F1 │ 0.114 │ 0.112 │ 0.264 │ 0.312 |
Showing 18 of 18 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | MedGMAE proposed | AUC | 76.40% | fine-tuned | MedGMAE: Gaussian Masked Autoencoders for Medical Volumetric Representation LearningSource quoteL409: 76.40 |
| 2026 | RadFinder proposed | AUC (disease classification) | 83.8 | classes=18 · training-data=RefCT, CT-RATE, Merlin, INSPECT · prompt-templates=7 | Learning to Read Where to Look: Disease-Aware Vision-Language Pretraining for 3D CTSource quoteL178: RadFinder (Ours) │ \checkmark │ \checkmark │ \checkmark │ \checkmark │ 31.5 │ \showstd{1.6} │ 78.0 │ \showstd{1.7} │ 83.8 │ \showstd{0.7} │ \bestci{77.0} │ \showstd{0.5} │ 69.0 │ \showstd{0.9} │ 40.3 │ \showstd{0.7} |
| 2026 | CT-DiagVLM proposed | AUC | 85.6 | labels=pseudo-labels · disease-count=60 | Disease-Centric Vision-Language Pretraining with Hybrid Visual Encoding for 3D Computed TomographySource quoteL408: AUC │ 81.1 │ 85.6 |
| 2026 | RAG-Nearest proposed | AUC Macro | 0.787 | CT-Net classification performance on generated synthetic CT volumes; macro AUC. | Retrieval-Augmented Anatomical Guidance for Text-to-CT GenerationSource quoteL212: RAG-Nearest │ 0.787 │ 0.776 │ 0.535 │ 0.606 |
| 2026 | CT-DiagVLM w/o Diagnosis-Aware Prompt ablation | AUC | 81.1 | labels=pseudo-labels · disease-count=60 | Disease-Centric Vision-Language Pretraining with Hybrid Visual Encoding for 3D Computed TomographySource quoteL408: AUC │ 81.1 │ 85.6 |
| 2026 | MPS-CT baseline | AUC (disease classification) | 83.8 | classes=18 · training-data=CT-RATE · prompt-templates=7 | Learning to Read Where to Look: Disease-Aware Vision-Language Pretraining for 3D CTSource quoteL176: MPS-CT~\cite{mpsct} │ \checkmark │ 16.3 │ 71.3 │ 83.8 │ 77.3 │ --- │ --- |
| 2026 | Text-to-CT baseline | AUC Macro | 0.745 | CT-Net classification performance on generated synthetic CT volumes; macro AUC. | Retrieval-Augmented Anatomical Guidance for Text-to-CT GenerationSource quoteL209: Text-to-CT~\cite{molino2025text} │ 0.745* │ 0.731* │ 0.477* │ 0.549* |
| 2025 | Ours (supervised-pretrained 3D ResNet-18 with vanilla CLIP training) proposed | AUC | 83.8% | split: val · 0-shot · backbone=3D ResNet-18 | More performant and scalable: Rethinking contrastive vision-language pre-training of radiology in the LLM eraSource quoteL173: Ours │ 83.8 │ 77.4 │ 79.6 │ 43.5 │ 77.3 │ 71.9 │ 74.8 │ 45.0 |
| 2025 | MedVista3D-UniMISS proposed | AUC | 0.782 | 0-shot · scope=global | MedVista3D: Vision-Language Modeling for Reducing Diagnostic Errors in 3D CT Disease Detection, Understanding and ReportingSource quoteL268: Results for global tasks. Both MedVista3D-ViT and MedVista3D-UniMISS outperform all global models in disease zero-shot and report retrieval (Table \ref{tab:compare_CTRATE_table}). For global disease zero-shot, MedVista3D-UniMISS achieves the highest AUC (0.782) and F1 (0.770), outperforming CT-CLIP by 7.4 points in AUC and 6.9 points in F1. For report retrieval, MedVista3D-ViT surpasses CT-CLIP by 4.3% and 6.7% in top-5 and top-10 recall. These results validate our model’s ability to jointly reduce inattentional blindness and under-reading errors. |
| 2025 | AnyMC3D (DINOv2) proposed | Mean AUC across 18 diseases | 0.882 | labels=18 diseases · backbone=DINOv2 · task-version=T11 | Revisiting 2D Foundation Models for Scalable 3D Medical Image ClassificationSource quoteL213: Chest CT Multi-Abnormality (T11). We evaluate on chest CT multi-abnormality classification by using the CT-RATE dataset~\cite{hamamci2024foundation} and the official data split. We compare AnyMC3D (DINOv2) against CT-Net~\cite{draelos2021machine} (supervised baseline) and CT-CLIP~\cite{hamamci2024foundation} (vision-language FM for chest CT). As shown in Fig.~\ref{fig:ct_rate}, AnyMC3D (DINOv2) consistently outperforms both baselines across all 18 diseases, improving mean AUC from 0.631 (CT-Net) and 0.768 (CT-CLIP) to 0.882. We further validated AnyMC3D by attending the VLM3D challenge. With only about 0.5M trainable parameters, AnyMC3D won 1st place among 118 participants, beating other competing methods that performed expensive large-scale CT pretraining. This is a strong demonstration of AnyMC3D's generalizability, as challenge solutions are typically well-engineered and task-optimized. |
| 2025 | BrgSA proposed | AUC | 79.2 | split: val · 0-shot | Bridged Semantic Alignment for Zero-shot 3D Medical Image DiagnosisSource quoteL37: To explore the potential of our vision-language alignment approach for zero-shot diagnosis, we expand the original 18 abnormality labels on CT-RATE~\citep{hamamci2024foundation} with 15 additional labels. The new benchmark, referred to as ``CT-RATE-LT," focuses on underrepresented abnormalities with limited occurrences in the dataset, providing a challenging yet valuable testing ground for evaluating diagnostic methods. Experimental results on CT-RATE-LT demonstrate that our method achieves excellent performance in diagnosing underrepresented abnormalities, showing significant improvements compared to the existing state-of-the-art (SOTA) method (AUC: 76.9 vs. 85.6). Furthermore, we evaluate our method on the benchmark CT-RATE and RAD-ChestCT~\citep{draelos2021machine} datasets, achieving SOTA performances in zero-shot abnormality diagnosis, with an AUC of 79.2 and 70.0 on internal and external validation, respectively. In addition to its diagnostic capabilities, our method significantly outperforms the SOTA in the report-to-volume retrieval task (Recall@10: 5.0 vs. 10.1), demonstrating effective semantic alignment between image and text features. |
| 2025 | MViT with segmentation supervision proposed | AUC-ROC | 82.94% | initialization=from-scratch · segmentation-supervision=used | Scaling Supervision for Free: Leveraging Universal Segmentation Models for Enhanced Medical Image DiagnosisSource quoteL154: 82.94 (+2.07) |
| 2025 | MViT without segmentation supervision ablation | AUC-ROC | 80.87% | initialization=from-scratch · segmentation-supervision=none | Scaling Supervision for Free: Leveraging Universal Segmentation Models for Enhanced Medical Image DiagnosisSource quoteL153: 80.87 |
| 2025 | BrgSA baseline | AUC | 79.2% | split: val · 0-shot | More performant and scalable: Rethinking contrastive vision-language pre-training of radiology in the LLM eraSource quoteL172: BrgSA │ 79.2 │ 73.3 │ 76.2 │ 38.5 │ 70.0 │ 65.5 │ 69.3 │ 39.1 |
| 2025 | CT-Net baseline | Mean AUC across 18 diseases | 0.631 | labels=18 diseases · method=CT-Net · task-version=T11 | Revisiting 2D Foundation Models for Scalable 3D Medical Image ClassificationSource quoteL213: Chest CT Multi-Abnormality (T11). We evaluate on chest CT multi-abnormality classification by using the CT-RATE dataset~\cite{hamamci2024foundation} and the official data split. We compare AnyMC3D (DINOv2) against CT-Net~\cite{draelos2021machine} (supervised baseline) and CT-CLIP~\cite{hamamci2024foundation} (vision-language FM for chest CT). As shown in Fig.~\ref{fig:ct_rate}, AnyMC3D (DINOv2) consistently outperforms both baselines across all 18 diseases, improving mean AUC from 0.631 (CT-Net) and 0.768 (CT-CLIP) to 0.882. We further validated AnyMC3D by attending the VLM3D challenge. With only about 0.5M trainable parameters, AnyMC3D won 1st place among 118 participants, beating other competing methods that performed expensive large-scale CT pretraining. This is a strong demonstration of AnyMC3D's generalizability, as challenge solutions are typically well-engineered and task-optimized. |
| 2025 | CT-CLIP (ClassFine) baseline | Mean AUC across 18 diseases | 0.768 | linear-probe · labels=18 diseases · backbone=CLIP · task-version=T11 · method-variant=ClassFine | Revisiting 2D Foundation Models for Scalable 3D Medical Image ClassificationSource quoteL213: Chest CT Multi-Abnormality (T11). We evaluate on chest CT multi-abnormality classification by using the CT-RATE dataset~\cite{hamamci2024foundation} and the official data split. We compare AnyMC3D (DINOv2) against CT-Net~\cite{draelos2021machine} (supervised baseline) and CT-CLIP~\cite{hamamci2024foundation} (vision-language FM for chest CT). As shown in Fig.~\ref{fig:ct_rate}, AnyMC3D (DINOv2) consistently outperforms both baselines across all 18 diseases, improving mean AUC from 0.631 (CT-Net) and 0.768 (CT-CLIP) to 0.882. We further validated AnyMC3D by attending the VLM3D challenge. With only about 0.5M trainable parameters, AnyMC3D won 1st place among 118 participants, beating other competing methods that performed expensive large-scale CT pretraining. This is a strong demonstration of AnyMC3D's generalizability, as challenge solutions are typically well-engineered and task-optimized. |
| 2024 | VoCo (Swin-H) proposed | vocabulary classification AUC | 73.69% | backbone=Swin-H | Large-Scale 3D Medical Image Pre-Training With Geometric Context PriorsSource quoteL668: VoCo~(Swin-H) │ 73.69 │ 24.12 |
| 2024 | MG-3D (3D Swin-B) proposed | AUC | 68.62% | split: test · few-shot · backbone=3D Swin-B | MG-3D: Multi-Grained Knowledge-Enhanced 3D Medical Vision-Language Pre-trainingSource quoteL431: AUC (%) │ 64.82 │ 65.12 │ 67.57 │ 68.62 |