CT-RATE

53 papers · 152 extracted observations · report generation · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test, regime=fine-tuned.

0.30.40.50.620242025CT2Rep: 0.534 (2024)VividMed: 0.312 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 18 of 18 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026MedGMAE proposedAUC76.40%fine-tunedMedGMAE: Gaussian Masked Autoencoders for Medical Volumetric Representation Learning
Source quote
L409: 76.40
2026RadFinder proposedAUC (disease classification)83.8classes=18 · training-data=RefCT, CT-RATE, Merlin, INSPECT · prompt-templates=7Learning to Read Where to Look: Disease-Aware Vision-Language Pretraining for 3D CT
Source quote
L178: RadFinder (Ours) │ \checkmark │ \checkmark │ \checkmark │ \checkmark │ 31.5 │ \showstd{1.6} │ 78.0 │ \showstd{1.7} │ 83.8 │ \showstd{0.7} │ \bestci{77.0} │ \showstd{0.5} │ 69.0 │ \showstd{0.9} │ 40.3 │ \showstd{0.7}
2026CT-DiagVLM proposedAUC85.6labels=pseudo-labels · disease-count=60Disease-Centric Vision-Language Pretraining with Hybrid Visual Encoding for 3D Computed Tomography
Source quote
L408: AUC │ 81.1 │ 85.6
2026RAG-Nearest proposedAUC Macro0.787CT-Net classification performance on generated synthetic CT volumes; macro AUC.Retrieval-Augmented Anatomical Guidance for Text-to-CT Generation
Source quote
L212: RAG-Nearest │ 0.787 │ 0.776 │ 0.535 │ 0.606
2026CT-DiagVLM w/o Diagnosis-Aware Prompt ablationAUC81.1labels=pseudo-labels · disease-count=60Disease-Centric Vision-Language Pretraining with Hybrid Visual Encoding for 3D Computed Tomography
Source quote
L408: AUC │ 81.1 │ 85.6
2026MPS-CT baselineAUC (disease classification)83.8classes=18 · training-data=CT-RATE · prompt-templates=7Learning to Read Where to Look: Disease-Aware Vision-Language Pretraining for 3D CT
Source quote
L176: MPS-CT~\cite{mpsct} │ \checkmark │ 16.3 │ 71.3 │ 83.8 │ 77.3 │ --- │ ---
2026Text-to-CT baselineAUC Macro0.745CT-Net classification performance on generated synthetic CT volumes; macro AUC.Retrieval-Augmented Anatomical Guidance for Text-to-CT Generation
Source quote
L209: Text-to-CT~\cite{molino2025text} │ 0.745* │ 0.731* │ 0.477* │ 0.549*
2025Ours (supervised-pretrained 3D ResNet-18 with vanilla CLIP training) proposedAUC83.8%split: val · 0-shot · backbone=3D ResNet-18More performant and scalable: Rethinking contrastive vision-language pre-training of radiology in the LLM era
Source quote
L173: Ours │ 83.8 │ 77.4 │ 79.6 │ 43.5 │ 77.3 │ 71.9 │ 74.8 │ 45.0
2025MedVista3D-UniMISS proposedAUC0.7820-shot · scope=globalMedVista3D: Vision-Language Modeling for Reducing Diagnostic Errors in 3D CT Disease Detection, Understanding and Reporting
Source quote
L268: Results for global tasks. Both MedVista3D-ViT and MedVista3D-UniMISS outperform all global models in disease zero-shot and report retrieval (Table \ref{tab:compare_CTRATE_table}). For global disease zero-shot, MedVista3D-UniMISS achieves the highest AUC (0.782) and F1 (0.770), outperforming CT-CLIP by 7.4 points in AUC and 6.9 points in F1. For report retrieval, MedVista3D-ViT surpasses CT-CLIP by 4.3% and 6.7% in top-5 and top-10 recall. These results validate our model’s ability to jointly reduce inattentional blindness and under-reading errors.
2025AnyMC3D (DINOv2) proposedMean AUC across 18 diseases0.882labels=18 diseases · backbone=DINOv2 · task-version=T11Revisiting 2D Foundation Models for Scalable 3D Medical Image Classification
Source quote
L213: Chest CT Multi-Abnormality (T11). We evaluate on chest CT multi-abnormality classification by using the CT-RATE dataset~\cite{hamamci2024foundation} and the official data split. We compare AnyMC3D (DINOv2) against CT-Net~\cite{draelos2021machine} (supervised baseline) and CT-CLIP~\cite{hamamci2024foundation} (vision-language FM for chest CT). As shown in Fig.~\ref{fig:ct_rate}, AnyMC3D (DINOv2) consistently outperforms both baselines across all 18 diseases, improving mean AUC from 0.631 (CT-Net) and 0.768 (CT-CLIP) to 0.882. We further validated AnyMC3D by attending the VLM3D challenge. With only about 0.5M trainable parameters, AnyMC3D won 1st place among 118 participants, beating other competing methods that performed expensive large-scale CT pretraining. This is a strong demonstration of AnyMC3D's generalizability, as challenge solutions are typically well-engineered and task-optimized.
2025BrgSA proposedAUC79.2split: val · 0-shotBridged Semantic Alignment for Zero-shot 3D Medical Image Diagnosis
Source quote
L37: To explore the potential of our vision-language alignment approach for zero-shot diagnosis, we expand the original 18 abnormality labels on CT-RATE~\citep{hamamci2024foundation} with 15 additional labels. The new benchmark, referred to as ``CT-RATE-LT," focuses on underrepresented abnormalities with limited occurrences in the dataset, providing a challenging yet valuable testing ground for evaluating diagnostic methods. Experimental results on CT-RATE-LT demonstrate that our method achieves excellent performance in diagnosing underrepresented abnormalities, showing significant improvements compared to the existing state-of-the-art (SOTA) method (AUC: 76.9 vs. 85.6). Furthermore, we evaluate our method on the benchmark CT-RATE and RAD-ChestCT~\citep{draelos2021machine} datasets, achieving SOTA performances in zero-shot abnormality diagnosis, with an AUC of 79.2 and 70.0 on internal and external validation, respectively. In addition to its diagnostic capabilities, our method significantly outperforms the SOTA in the report-to-volume retrieval task (Recall@10: 5.0 vs. 10.1), demonstrating effective semantic alignment between image and text features.
2025MViT with segmentation supervision proposedAUC-ROC82.94%initialization=from-scratch · segmentation-supervision=usedScaling Supervision for Free: Leveraging Universal Segmentation Models for Enhanced Medical Image Diagnosis
Source quote
L154: 82.94 (+2.07)
2025MViT without segmentation supervision ablationAUC-ROC80.87%initialization=from-scratch · segmentation-supervision=noneScaling Supervision for Free: Leveraging Universal Segmentation Models for Enhanced Medical Image Diagnosis
Source quote
L153: 80.87
2025BrgSA baselineAUC79.2%split: val · 0-shotMore performant and scalable: Rethinking contrastive vision-language pre-training of radiology in the LLM era
Source quote
L172: BrgSA │ 79.2 │ 73.3 │ 76.2 │ 38.5 │ 70.0 │ 65.5 │ 69.3 │ 39.1
2025CT-Net baselineMean AUC across 18 diseases0.631labels=18 diseases · method=CT-Net · task-version=T11Revisiting 2D Foundation Models for Scalable 3D Medical Image Classification
Source quote
L213: Chest CT Multi-Abnormality (T11). We evaluate on chest CT multi-abnormality classification by using the CT-RATE dataset~\cite{hamamci2024foundation} and the official data split. We compare AnyMC3D (DINOv2) against CT-Net~\cite{draelos2021machine} (supervised baseline) and CT-CLIP~\cite{hamamci2024foundation} (vision-language FM for chest CT). As shown in Fig.~\ref{fig:ct_rate}, AnyMC3D (DINOv2) consistently outperforms both baselines across all 18 diseases, improving mean AUC from 0.631 (CT-Net) and 0.768 (CT-CLIP) to 0.882. We further validated AnyMC3D by attending the VLM3D challenge. With only about 0.5M trainable parameters, AnyMC3D won 1st place among 118 participants, beating other competing methods that performed expensive large-scale CT pretraining. This is a strong demonstration of AnyMC3D's generalizability, as challenge solutions are typically well-engineered and task-optimized.
2025CT-CLIP (ClassFine) baselineMean AUC across 18 diseases0.768linear-probe · labels=18 diseases · backbone=CLIP · task-version=T11 · method-variant=ClassFineRevisiting 2D Foundation Models for Scalable 3D Medical Image Classification
Source quote
L213: Chest CT Multi-Abnormality (T11). We evaluate on chest CT multi-abnormality classification by using the CT-RATE dataset~\cite{hamamci2024foundation} and the official data split. We compare AnyMC3D (DINOv2) against CT-Net~\cite{draelos2021machine} (supervised baseline) and CT-CLIP~\cite{hamamci2024foundation} (vision-language FM for chest CT). As shown in Fig.~\ref{fig:ct_rate}, AnyMC3D (DINOv2) consistently outperforms both baselines across all 18 diseases, improving mean AUC from 0.631 (CT-Net) and 0.768 (CT-CLIP) to 0.882. We further validated AnyMC3D by attending the VLM3D challenge. With only about 0.5M trainable parameters, AnyMC3D won 1st place among 118 participants, beating other competing methods that performed expensive large-scale CT pretraining. This is a strong demonstration of AnyMC3D's generalizability, as challenge solutions are typically well-engineered and task-optimized.
2024VoCo (Swin-H) proposedvocabulary classification AUC73.69%backbone=Swin-HLarge-Scale 3D Medical Image Pre-Training With Geometric Context Priors
Source quote
L668: VoCo~(Swin-H) │ 73.69 │ 24.12
2024MG-3D (3D Swin-B) proposedAUC68.62%split: test · few-shot · backbone=3D Swin-BMG-3D: Multi-Grained Knowledge-Enhanced 3D Medical Vision-Language Pre-training
Source quote
L431: AUC (%) │ 64.82 │ 65.12 │ 67.57 │ 68.62