CSIQ
45 papers · 77 extracted observations · image quality assessment · vision · Markdown · CSV · JSON API
Tasks on CSIQAll tasks (45)Image Quality Assessment (40)Blind Image Quality Assessment (2)Video Quality Assessment (2)Image Quality Regression (1)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Image Quality Assessment: proposed/measured results on test (including papers where test split is standard/implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | HarmonyIQA (NR) SOTA frontier | 0.968 | 2025-01-01 | evaluation=no-reference · split-ratio=4:1 train/test · 4:1 train/test split. | HarmonyIQA: Pioneering Benchmark and Model for Image Harmonization Quality AssessmentSource quoteHarmonyIQA │ \textcolor{mred}{0.968} │ \textcolor{mred}{0.977} │ \textcolor{mred}{0.901} │ \textcolor{mred}{0.913} │ \textcolor{mred}{0.935} │ \textcolor{mred}{0.938} |
| 2 | CSFIQA SOTA frontier | 0.967 | 2024-11-01 | evaluation=80/20 train-test split; 10 repeats; median · Main evaluation setup: 80/20 train/test split, repeated 10 times; median SRCC/PLCC re… | Scale Contrastive Learning with Selective Attentions for Blind Image Quality AssessmentSource quoteBlind image quality assessment (BIQA) serves as a fundamental task in computer vision, yet it often fails to consistently align with human subjective perception. Recent advances show that multi-scale evaluation strategies are promising due to their ability to replicate the hierarchical structure of human vision. However, the effectiveness of these strategies is limited by a lack of understanding of how different image scales influence perceived quality. This paper addresses two primary challenges: the significant redundancy of information across different scales, and the confusion caused by combining features from these scales, which may vary widely in quality. To this end, a new multi-scale BIQA framework is proposed, namely Contrast-Constrained Scale-Focused IQA Framework (CSFIQA). CSFIQA features a selective focus attention mechanism to minimize information redundancy and highlight critical quality-related information. Additionally, CSFIQA includes a scale-level contrastive learning module equipped with a noise sample matching mechanism to identify quality discrepancies across the same image content at different scales. By exploring the intrinsic relationship between image scales and the perceived quality, the proposed CSFIQA achieves leading performance on eight benchmark datasets, e.g., achieving SRCC values of 0.967 (versus 0.947 in CSIQ) and 0.905 (versus 0.876 in LIVEC). |
| 3 | MP-IQE SOTA frontier | 0.961 | 2024-04-01 | Full MP-IQE variant; paper reports 80/20 train/test and the median over 10 runs. | Multi-Modal Prompt Learning on Blind Image Quality AssessmentSource quoteMP-IQE │ 0.968 │ 0.961 │ 0.916 │ 0.900 |
| 4 | MR-IQA (Diff) SOTA frontier | 0.947 | 2023-02-01 | repeats=10 random splits · test-patches=8 randomly sampled; horizontal/vertical flipping · patch-selection=difference masking · train-test-split=80/20 by reference image · 80/20 train/test split by reference image; average over ten random splits. Diff maski… | Mask Reference Image Quality AssessmentSource quoteOurs (Diff) │ 0.977 │ 0.980 │ 0.947 │ 0.952 │ 0.912 │ 0.930 │ 0.952 │ 0.955 \Xhline{1.2pt} \specialrule{0em}{1pt}{1pt} |
| 5 | GDBC-DBCNN-LC | 0.9463 | 2023-11-01 | trials=10; median reported · bias-rate=100% · annotations-per-image=1 · Training with LC-MOS and GDBC; 100% bias rate and M=1 annotation per image. LA-MOS pr… | Learning with Noisy Low-Cost MOS for Image Quality Assessment via Dual-Bias CalibrationSource quoteGDBC-\text{DBCNN}-LC │ 0.8053 │ 0.8424 │ 0.6137 │ 0.7007 │ 0.7095 │ 0.5181 │ 0.9074 │ 0.9159 │ 0.7377 │ 0.9463 │ 0.9552 │ 0.8067 |
| 6 | dipIQ (CORNIA features) SOTA frontier | 0.93 | 2019-04-01 | training_data=LIVE · distortion_subset=ALL4: JP2K, JPEG, WN, BLUR · Median across 1,000 sessions; trained on LIVE and tested on CSIQ. Opinion-unaware pai… | dipIQ: Blind Image Quality Assessment by Learning-to-Rank Discriminable Image PairsSource quotedipIQ │ {\bf 0.944} │ {\bf 0.936} │ {\bf 0.904} │ {\bf 0.932} │ {\bf 0.930} |
| 7 | MQAF-R | 0.91 | 2026-02-01 | Cross-dataset evaluation: trained on KADID-10K and tested on CSIQ, without fine-tunin… | Image Quality Assessment: Exploring Quality Awareness via Memory-driven Distortion Patterns MatchingSource quoteMQAF-R (Ours) │ \bf 0.913 │ \bf0.941 │ \bf 0.903 │ 0.910 │ \bf0.845 │ \bf 0.847 |
| 8 | Proposed BIQA method (Ours, All databases) | 0.907 | 2020-01-01 | resolution=original image size · training-data=all six IQA databases · Trained on all six IQA databases using intra-database image pairs; tested at original… | Learning To Blindly Assess Image Quality In The Laboratory And WildSource quoteOurs (All databases) │ {\bf 0.961} │ {\bf 0.907} │ {\bf 0.855} │ {\bf 0.863} │ {\bf 0.851} │ {\bf 0.894} |
| 9 | Proposed multi-dimensional IQA model | 0.86 | 2026-01-01 | External IQA test set; first value in the table’s SRCC/PLCC pair. | How far have we Gone in Generative Image Restoration? A Study on its Capability, Limitations and Evaluation PracticesSource quoteCSIQ │ 0.70/0.65 │ 0.62/0.63 │ 0.77/0.71 │ 0.77/0.72 │ 0.79/0.74 │ 0.86/0.83 |
| 10 | DUBMA | 0.84 | 2025-01-01 | Correlation with MOS on the subject-rated image set; trained on synthetic image pairs… | Deep Opinion-Unaware Blind Image Quality Assessment by Learning and Adapting from Multiple AnnotatorsSource quote0.930 0.840 |
| 11 | QAIRN (Q2 from γ2) | 0.832 | 2023-11-01 | pooling=Minkowski · attention-map=γ2 · quality-estimate=Q2 · Minkowski-pooled quality estimate Q2 from the γ2 attention map; correlation with huma… | Joint Deep Image Restoration and Unsupervised Quality AssessmentSource quote\(Q_2\), from \(\gamma_2\) │ 0.859 │ 0.832 │ 0.628 |
| 12 | CVRKD-IQA NAR-student + Content-variant NAR | 0.829 | 2022-01-01 | reference=content-variant non-aligned HQ · training-data=KADID-10K · Cross-dataset evaluation after training on synthetic Kaddid-10K; content-variant non-… | Content-Variant Reference Image Quality Assessment via Knowledge DistillationSource quoteNAR-student + Content-variant NAR │ 0.913 │ 0.829 │ 0.691 |
Other primary task on CSIQ: Blind Image Quality Assessment · SRCC ↑ (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DEIQT + (proposed quality context contrastive learning strategy) SOTA frontier | 0.956 | 2024-01-01 | method=DEIQT · backbone=ViT · Table 2 portability experiment: DEIQT with a ViT backbone, fine-tuned with the propos… | Integrating Global Context Contrast and Local Sensitivity for Blind Image Quality AssessmentSource quote0.956 |
| 2 | GraphIQA SOTA frontier | 0.947 | 2021-03-01 | Single-database evaluation; experiments conducted 10 times; pretraining did not use a… | GraphIQA: Learning Distortion Graph Representations for Blind Image Quality AssessmentSource quoteOurs │ 0.911 │ 0.845 │ 0.979 │ 0.947 │ 0.930 \\[1pt] |
Other primary task on CSIQ: Image Quality Assessment · PLCC ↑ · test (7 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | LML-IQA SOTA frontier (+1 variant) | 0.977 | 2024-06-01 | Overall dataset result; the paper reports final metrics as averages over 10 independe… | Local Manifold Learning for No-Reference Image Quality AssessmentSource quoteImage Quality Assessment (IQA) methods typically overlook local manifold structures, leading to compromised discriminative capabilities in perceptual quality evaluation. To address this limitation, we present LML-IQA, an innovative no-reference IQA (NR-IQA) approach that leverages a combination of local manifold learning and contrastive learning. Our approach first extracts multiple patches from each image and identifies the most visually salient region. This salient patch serves as a positive sample for contrastive learning, while other patches from the same image are treated as intra-class negatives to preserve local distinctiveness. Patches from different images also act as inter-class negatives to enhance feature separation. Additionally, we introduce a mutual learning strategy to improve the model’s ability to recognize and prioritize visually important regions. Comprehensive experiments across eight benchmark datasets demonstrate significant performance gains over state-of-the-art methods, achieving a PLCC of 0.942 on TID2013 (compared to 0.908) and 0.977 on CSIQ (compared to 0.965). |
| 2 | SaTQA (#4 ablation: SCL, MSB and PAB enabled) SOTA frontier | 0.972 | 2024-01-01 | test-patches=8 · configuration=SCL, MSB, and PAB enabled · Ablation table's full-component configuration; results averaged over 10 runs with dif… | Transformer-Based No-Reference Image Quality Assessment via Supervised Contrastive LearningSource quote4 │ \checkmark │ \checkmark │ \checkmark │ 0.903 │ 0.877 │ 0.972 │ 0.965 [1.3pt] |
| 3 | MR-IQA (Diff) SOTA frontier | 0.952 | 2023-02-01 | repeats=10 random splits · test-patches=8 randomly sampled; horizontal/vertical flipping · patch-selection=difference masking · train-test-split=80/20 by reference image · 80/20 train/test split by reference image; average over ten random splits. Diff maski… | Mask Reference Image Quality AssessmentSource quoteOurs (Diff) │ 0.977 │ 0.980 │ 0.947 │ 0.952 │ 0.912 │ 0.930 │ 0.952 │ 0.955 \Xhline{1.2pt} \specialrule{0em}{1pt}{1pt} |
| 4 | MQAF-R | 0.903 | 2026-02-01 | Cross-dataset evaluation: trained on KADID-10K and tested on CSIQ, without fine-tunin… | Image Quality Assessment: Exploring Quality Awareness via Memory-driven Distortion Patterns MatchingSource quoteMQAF-R (Ours) │ \bf 0.913 │ \bf0.941 │ \bf 0.903 │ 0.910 │ \bf0.845 │ \bf 0.847 |
| 5 | DUBMA | 0.859 | 2025-01-01 | Correlation with MOS on the subject-rated image set; trained on synthetic image pairs… | Deep Opinion-Unaware Blind Image Quality Assessment by Learning and Adapting from Multiple AnnotatorsSource quote0.918 0.859 |
| 6 | Proposed multi-dimensional IQA model | 0.83 | 2026-01-01 | External IQA test set; second value in the table’s SRCC/PLCC pair. | How far have we Gone in Generative Image Restoration? A Study on its Capability, Limitations and Evaluation PracticesSource quoteCSIQ │ 0.70/0.65 │ 0.62/0.63 │ 0.77/0.71 │ 0.77/0.72 │ 0.79/0.74 │ 0.86/0.83 |
| 7 | Life-IQA | 0.738 | 2026-01-01 | Cross-dataset evaluation: trained on KonIQ and tested on CSIQ. | Life-IQA: Boosting Blind Image Quality Assessment through GCN-enhanced Layer Interaction and MoE-based Feature DecouplingSource quoteLife-IQA │ \textbf{\textcolor{red}{0.715}} │ \textbf{\textcolor{red}{0.738}} │ \textbf{\textcolor{red}{0.453}} │ \textbf{\textcolor{red}{0.578}} │ 0.822 │ \textbf{\textcolor{red}{0.800}} |
Other primary task on CSIQ: Image Quality Assessment · SROCC ↑ · test (7 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | CLRIQA+FT (Proposed) SOTA frontier | 0.953 | 2019-11-01 | test-sub-images=60 · train-test-split=80/20 · Fine-tuned after pre-training; evaluation uses a random 80/20 train/test split, and a… | Controllable List-wise Ranking for Universal No-reference Image Quality AssessmentSource quoteCLRIQA+FT (Proposed) │ 0.979 │ 0.980 │ 0.953 │ 0.958 │ 0.935 │ 0.929 │ 0.821 │ 0.851 │ 0.921 │ 0.925\cr |
| 2 | WaDIQaM-FR SOTA frontier | 0.931 | 2018-01-01 | evaluation=cross-database · reference-type=full-reference · training-dataset=TID2013 · Cross-database evaluation: trained on the full TID2013 database and tested on CSIQ. | Deep Neural Networks for No-Reference and Full-Reference Image Quality AssessmentSource quoteWaDIQaM-FR (proposed) │ \bf{0.751} │ 0.909 │ \bf{0.931} │ 0.936 |
| 3 | BLISS-C SOTA frontier (+1 variant) | 0.918 | 2014-01-01 | ALL4 (JP2K, JPEG, WN, and BLUR combined); trained on synthetic scores from 3300 Flick… | Beyond Human Opinion Scores: Blind Image Quality Assessment Based on Synthetic ScoresSource quote0.918 |
| 4 | QualNet (proposed) | 0.907 | 2020-06-01 | — | No-Reference Image Quality Assessment via Feature Fusion and Multi-Task LearningSource quoteQualNet (proposed) │ 0.980 │ 0.984 │ 0.907 │ 0.921 │ 0.890 │ 0.901 │ 0.961 │ 0.965 │ 0.960 │ 0.952 │ 0.938 │ 0.943\tabularnewline |
| 5 | Unpaired-IQA (ER-IQA; reported as “Ours”) | 0.871 | 2021-05-01 | evaluation=cross-dataset · training-dataset=LIVE · reference-selection=within-dataset; no train-test content overlap · Cross-dataset test; synthetic-dataset references are selected within the dataset, wit… | ER-IQA: Boosting Perceptual Quality Assessment Using External Reference ImagesSource quoteKonIQ │ LIVEC │ 0.755 │ 0.785 │ 0.809 \multirow{2}{*}{Synthetic} │ LIVE │ CSIQ │ 0.758 │ 0.744 │ 0.871 |
| 6 | SaTQA (proposed) | 0.831 | 2024-01-01 | evaluation=cross-dataset · training-dataset=LIVE · Cross-dataset evaluation: train on LIVE, test on CSIQ without parameter tuning; resul… | Transformer-Based No-Reference Image Quality Assessment via Supervised Contrastive LearningSource quoteProposed │ 0.791 │ 0.788 │ 0.831 │ 0.617 |
| 7 | Life-IQA | 0.715 | 2026-01-01 | Cross-dataset evaluation: trained on KonIQ and tested on CSIQ. | Life-IQA: Boosting Blind Image Quality Assessment through GCN-enhanced Layer Interaction and MoE-based Feature DecouplingSource quoteLife-IQA │ \textbf{\textcolor{red}{0.715}} │ \textbf{\textcolor{red}{0.738}} │ \textbf{\textcolor{red}{0.453}} │ \textbf{\textcolor{red}{0.578}} │ 0.822 │ \textbf{\textcolor{red}{0.800}} |
Other primary task on CSIQ: Image Quality Assessment · PCC ↑ (3 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | GMSD SOTA frontier | 0.954 | 2013-08-01 | channel=luminance · CSIQ database (886 distorted images); evaluated on the luminance channel; PCC compute… | Gradient Magnitude Similarity Deviation: A Highly Efficient Perceptual Image Quality IndexSource quote0.954 |
| 2 | SOS-H-rNSE | 0.933 | 2015-10-01 | distortions=JP2K, JPEG, WN, GB · Common distortion types JP2K, JPEG, WN, and GB; SOS-H-rNSE configuration. | Learn to Evaluate Image Perceptual Quality Blindly from Statistics of Self-similaritySource quoteFrom TABLE~\ref{Table_2}, we can observe that both SOS-MD and SOS-H show good performance on the three databases in terms of PCC and SRC. The best results on all the three databases are achieved by the method SOS-H-rNSE, with PCC values 0.946, 0.933, and 0.937 on the three databases, respectively. For every single distortion type, it also demonstrates PCC and SRC values consistently higher than 0.9. Note that due to the scale difference of subjective scores on the three databases, the resulting RMSE values range differently. |
| 3 | QAIRN (Q2 from γ2) | 0.859 | 2023-11-01 | pooling=Minkowski · attention-map=γ2 · quality-estimate=Q2 · Minkowski-pooled quality estimate Q2 from the γ2 attention map; correlation with huma… | Joint Deep Image Restoration and Unsupervised Quality AssessmentSource quote\(Q_2\), from \(\gamma_2\) │ 0.859 │ 0.832 │ 0.628 |
TaskImage Quality Assessment (66)Video Quality Assessment (6)Blind Image Quality Assessment (3)Image Quality Regression (2)
Metricsrcc (23)plcc (23)srocc (12)pcc (4)src (3)pra (2)pearson correlation between estimated image qual (2)
Showing 9 of 9 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | Life-IQA proposed | SROCC | 0.715 | Image Quality Assessment · split: test | Life-IQA: Boosting Blind Image Quality Assessment through GCN-enhanced Layer Interaction and MoE-based Feature DecouplingSource quoteL239: Life-IQA │ \textbf{\textcolor{red}{0.715}} │ \textbf{\textcolor{red}{0.738}} │ \textbf{\textcolor{red}{0.453}} │ \textbf{\textcolor{red}{0.578}} │ 0.822 │ \textbf{\textcolor{red}{0.800}} |
| 2023 | SaTQA (proposed) proposed | SROCC | 0.831 | Image Quality Assessment · split: test · evaluation=cross-dataset · training-dataset=LIVE | Transformer-Based No-Reference Image Quality Assessment via Supervised Contrastive LearningSource quoteL199: Proposed │ 0.791 │ 0.788 │ 0.831 │ 0.617 |
| 2021 | Unpaired-IQA (ER-IQA; reported as “Ours”) proposed | SROCC | 0.871 | Image Quality Assessment · split: test · evaluation=cross-dataset · training-dataset=LIVE · reference-selection=within-dataset; no train-test content overlap | ER-IQA: Boosting Perceptual Quality Assessment Using External Reference ImagesSource quoteL227: KonIQ │ LIVEC │ 0.755 │ 0.785 │ 0.809 \multirow{2}{*}{Synthetic} │ LIVE │ CSIQ │ 0.758 │ 0.744 │ 0.871 |
| 2020 | QualNet (proposed) proposed | SROCC | 0.907 | Image Quality Assessment | No-Reference Image Quality Assessment via Feature Fusion and Multi-Task LearningSource quoteL398: QualNet (proposed) │ 0.980 │ 0.984 │ 0.907 │ 0.921 │ 0.890 │ 0.901 │ 0.961 │ 0.965 │ 0.960 │ 0.952 │ 0.938 │ 0.943\tabularnewline |
| 2019 | C3DVQA (60-frame segments) proposed | SROCC | 0.9152 | Video Quality Assessment · segment-frames=60 | C3DVQA: Full-Reference Video Quality Assessment with 3D Convolutional Neural NetworkSource quoteL135: SROCC │ 0.7423 │ 0.8360 │ 0.9152 │ 0.9331 |
| 2019 | C3DVQA (120-frame segments) proposed | SROCC | 0.9331 | Video Quality Assessment · segment-frames=120 | C3DVQA: Full-Reference Video Quality Assessment with 3D Convolutional Neural NetworkSource quoteL135: SROCC │ 0.7423 │ 0.8360 │ 0.9152 │ 0.9331 |
| 2019 | RRLRIQA proposed non-standard slice | SROCC | 0.907 | Image Quality Assessment · split: test · fine-tuned · repeats=20; median · split-protocol=80/20 grouped by reference image · training-target=objective-score rewards, not MOS | No-Reference Image Quality Assessment with Reinforcement Recursive List-Wise RankingSource quoteL369: 0.907 |
| 2019 | CLRIQA+FT (Proposed) proposed | SROCC | 0.953 | Image Quality Assessment · split: test · fine-tuned · test-sub-images=60 · train-test-split=80/20 | Controllable List-wise Ranking for Universal No-reference Image Quality AssessmentSource quoteL289: CLRIQA+FT (Proposed) │ 0.979 │ 0.980 │ 0.953 │ 0.958 │ 0.935 │ 0.929 │ 0.821 │ 0.851 │ 0.921 │ 0.925\cr |
| 2016 | WaDIQaM-FR proposed | SROCC | 0.931 | Image Quality Assessment · split: test · evaluation=cross-database · reference-type=full-reference · training-dataset=TID2013 | Deep Neural Networks for No-Reference and Full-Reference Image Quality AssessmentSource quoteL883: WaDIQaM-FR (proposed) │ \bf{0.751} │ 0.909 │ \bf{0.931} │ 0.936 |