Calgary-Campinas

6 papers · 20 extracted observations · mri reconstruction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

25.930.234.438.6202220242026ST-GAN: 26.82 (2022)RecurrentVarNet: 32.71 (2022)RecurrentVarNet: 36.02 (2022)Unrolled[3D]: 34.72 (2026)Unrolled[3D]: 37.74 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 2 of 2 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2021RecurrentVarNet proposedNMSE0.0038split: test · acceleration=5-foldRecurrent Variational Network: A Deep Learning Inverse Problem Solver applied to the task of Accelerated MRI Reconstruction
Source quote
L287: RecurrentVarNet │ 0.9418 │ 36.02 │ 0.0038
2021RecurrentVarNet proposedNMSE0.0085split: test · acceleration=10-foldRecurrent Variational Network: A Deep Learning Inverse Problem Solver applied to the task of Accelerated MRI Reconstruction
Source quote
L293: RecurrentVarNet │ 0.9073 │ 32.71 │ 0.0085