| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Unrolled[3D] SOTA frontier (+1 variant) | 37.74 | 2026-01-01 | resolution=218x170 · Amplitude-image PSNR; retrospective Poisson-disc undersampling at R=5, with models tr… | Efficient Unrolled Networks for Large-Scale 3D Inverse ProblemsSource quote\colorbox[rgb]{0.7,1.0,0.7}{37.74} │ \colorbox[rgb]{0.7,1.0,0.7}{34.72} |
| 2 | RecurrentVarNet SOTA frontier (+1 variant) | 36.02 | 2022-01-01 | acceleration=5-fold · 5-fold acceleration; average test-set metric; best checkpoint selected using validati… | Recurrent Variational Network: A Deep Learning Inverse Problem Solver applied to the task of Accelerated MRI ReconstructionSource quoteRecurrentVarNet │ 0.9418 │ 36.02 │ 0.0038 |
| 3 | ST-GAN | 26.82 | 2022-01-01 | undersampling-mask=G1D10% · Test set; G1D10% mask. | Fast MRI Reconstruction: How Powerful Transformers Are?Source quoteSwinMR achieved the results with the highest SSIM (SwinMR/ST-GAN: 0.882/0.855 by G1D10%) and PSNR (27.68/26.82), whereas the SSIMs and PSNRs of the results reconstructed by all transformer based GANs (ST-GAN, EES-GAN, TES-GAN) fell slightly behind (Fig.~\ref{fig:SSIM}). However, when assessed for the visual perceptional metric FID, TES-GAN achieved the best FID, followed by other transformer based GANs and the non-GAN model SwinMR. |
Splittest (12)
Showing 4 of 4 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2022 | SwinMR (PI) proposed | Fréchet inception distance (FID) | 40.81 | mask=Gaussian 1D 30% · noise-level=80% | Swin transformer for fast MRISource quoteL480: NL80% │ 40.81 │ 73.12 │ 250.99 |
| 2022 | TES-GAN proposed | FID | 7.60 | split: test · fid-reference=zero-filled images · undersampling-mask=G1D30% | Fast MRI Reconstruction: How Powerful Transformers Are?Source quoteL195: TES-GAN │ 17.98 │ 7.60 │ 114.703 │ 0.041 │ 11.40/164.37^* │ 800.73 |
| 2022 | DAGAN baseline | Fréchet inception distance (FID) | 73.12 | mask=Gaussian 1D 30% · noise-level=80% | Swin transformer for fast MRISource quoteL480: NL80% │ 40.81 │ 73.12 │ 250.99 |
| 2022 | SwinMR baseline | FID | 21.03 | split: test · fid-reference=zero-filled images · undersampling-mask=G1D30% | Fast MRI Reconstruction: How Powerful Transformers Are?Source quoteL192: SwinMR │ 60.60 │ 21.03 │ 59.269 │ 0.041 │ 11.40 │ 800.73 |