Building image
2 papers · 4 extracted observations · image segmentation · vision · Markdown · CSV · JSON API
Also indexed as: building-image
Metrictime to converge to a low energy solution (1)time to converge to the reported solution energy (1)psnr (1)ssim (1)
Showing 4 of 4 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2019 | 2-D RIA LRMF-AM with simple averaging fusion (“Average”) proposed | PSNR | 31.99 dB | fusion=average · noise_type=mixed noise | Image Denoising by Random Interpolation Average with Low-Rank Matrix ApproximationSource quoteL249: Fig. \ref{main4} plots the PSNR and SSIM versus different hard thresholding parameter \tau of denoising a building image in different ratios of mixed noise. Although a popular method to determine the optimal value is using the statistical information of noise, it it impractical because the standard deviation \sigma needs to be known. Moreover, when the image is corrupted by more complicated noise distribution, e.g., mixed noise, it is difficult to choose the optimal value based on the statistical information of noise. Therefore, we select the hard thresholding parameter \tau via (r+1)th largest singular value \lambda-r+1. Assume that both refer to singular values are arranged in the descending order. At first, we test the denoising performance with different grids of the (r+1) singular value, where \lambda-r+1 is sampled with interval grid 1 from 0 to the value of (r+1)th singular value. \tau has a wide range from \tau = 11 to \tau = 17 that generates faithful denoising results, where the differences of the PSNR and SSIM in the denoised image are less than 0.030 dB and 0.001, respectively. The optimal results are achieved at \tau = 15, which makes the selection of \tau robust to user. We observe that when \tau \approx 15 , \lambda-r+1 \approx 30, i.e., \tau \approx \lambda-r+1/2. Therefore, the hard thresholding parameter \tau of our method "Hard thresholding" is adopted at \tau = \lambda-r+1/2 for the following simulation results. The threshold \tau-universal = \sigma\sqrt{2log(L)} (L = M × N is the number of pixels in image) is well known in wavelet literature \cite{HOSVD, RWBSRR, AUSWS} as the Universal threshold, which is the optimal threshold in the asymptotic sense. Compared with the universal threshold, the best empirical threshold \tau = 15 adopted in our work is much lower than \sigma\sqrt{2log(L)}, which indicates that the proposed method is not sensitive to the threshold value, as a wide range of threshold can be selected especially for large matrix size. Since the "Average" method is insensitive to the hard-thresholding parameter \tau, it is not included in Fig. \ref{main4}, where the PSNR and SSIM are 31.99 dB and 0.7456, respectively. |
| 2019 | 2-D RIA LRMF-AM with simple averaging fusion (“Average”) proposed | SSIM | 0.7456 | fusion=average · noise_type=mixed noise | Image Denoising by Random Interpolation Average with Low-Rank Matrix ApproximationSource quoteL249: Fig. \ref{main4} plots the PSNR and SSIM versus different hard thresholding parameter \tau of denoising a building image in different ratios of mixed noise. Although a popular method to determine the optimal value is using the statistical information of noise, it it impractical because the standard deviation \sigma needs to be known. Moreover, when the image is corrupted by more complicated noise distribution, e.g., mixed noise, it is difficult to choose the optimal value based on the statistical information of noise. Therefore, we select the hard thresholding parameter \tau via (r+1)th largest singular value \lambda-r+1. Assume that both refer to singular values are arranged in the descending order. At first, we test the denoising performance with different grids of the (r+1) singular value, where \lambda-r+1 is sampled with interval grid 1 from 0 to the value of (r+1)th singular value. \tau has a wide range from \tau = 11 to \tau = 17 that generates faithful denoising results, where the differences of the PSNR and SSIM in the denoised image are less than 0.030 dB and 0.001, respectively. The optimal results are achieved at \tau = 15, which makes the selection of \tau robust to user. We observe that when \tau \approx 15 , \lambda-r+1 \approx 30, i.e., \tau \approx \lambda-r+1/2. Therefore, the hard thresholding parameter \tau of our method "Hard thresholding" is adopted at \tau = \lambda-r+1/2 for the following simulation results. The threshold \tau-universal = \sigma\sqrt{2log(L)} (L = M × N is the number of pixels in image) is well known in wavelet literature \cite{HOSVD, RWBSRR, AUSWS} as the Universal threshold, which is the optimal threshold in the asymptotic sense. Compared with the universal threshold, the best empirical threshold \tau = 15 adopted in our work is much lower than \sigma\sqrt{2log(L)}, which indicates that the proposed method is not sensitive to the threshold value, as a wide range of threshold can be selected especially for large matrix size. Since the "Average" method is insensitive to the hard-thresholding parameter \tau, it is not included in Fig. \ref{main4}, where the PSNR and SSIM are 31.99 dB and 0.7456, respectively. |
| 2008 | Optimized BP (partially optimal solution followed by inference on the projected energy) proposed | time to converge to a low-energy solution | 0.85 seconds | Optimized BP runs on the projected energy after computing a partially optimal solution;… | Reduce, reuse & recycle: Efficiently solving multi-label MRFsSource quoteL406: BP converges to a low energy (although not the global optima), in 0.85 seconds, while standard BP converges to a much higher energy in 11.12 seconds. The solutions corresponding to these energies are shown in Figure 6. |
| 2008 | Standard BP baseline | time to converge to the reported solution energy | 11.12 seconds | Standard BP; it converges to a much higher energy than optimized BP, and does not reach… | Reduce, reuse & recycle: Efficiently solving multi-label MRFsSource quoteL406: BP converges to a low energy (although not the global optima), in 0.85 seconds, while standard BP converges to a much higher energy in 11.12 seconds. The solutions corresponding to these energies are shown in Figure 6. |