ARC-Challenge

173 papers · 317 extracted observations · commonsense reasoning · language · Markdown · CSV · JSON API

Also indexed as: ARC-C, ARC Challenge, AI2 ARC Challenge

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

22.445.468.491.5202120242027N-XKT K+Q base: 35.87 (2021)Coherence boosting (Ours), GPT-2 Small, α* = -4.2: 29.1 (2022)Iterative RPO (Llama-2-70B-Chat, iteration 3): 86.7 (2024)CRISP (Clustered Importance Sampling): 38.6 (2025)AdaSTaR (Qwen 2.5 3B): 85.0 (2025)PbPO w/ token RM (5-itr): 73.5 (2025)DLCM (2.3B): 34.81 (2025)OLMoE-1.3B-SeeDNorm: 34.5 (2026)PCA+DotResize: 56.23 (2026)BASED+LLoPS (LLoPS-1B): 27.13 (2026)StateLoop: 28.33 (2026)LoopFold D=9: 29.35 (2026)CPLM: 41.55 (2026)SSD-MIMO (R2O2-c): 28.2 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 6 of 6 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025GPTQ-quantized model, post-calibration proposedCalibration error0.19calibration=soft-prompt post-calibration · quantization=GPTQ · confidence_subset=correct answersQuantized Can Still Be Calibrated: A Unified Framework to Calibration in Quantized Large Language Models
Source quote
L287: 2 (a), the GPTQ quantized model’s calibration error decreased from 0.39 to 0.19, while the BNB quantized model’s error reduced from 0.37 to 0.24.
2025GPTQ-quantized model, post-calibration proposedCalibration error0.74calibration=soft-prompt post-calibration · quantization=GPTQ · confidence_subset=incorrect answersQuantized Can Still Be Calibrated: A Unified Framework to Calibration in Quantized Large Language Models
Source quote
L290: 0.85 to 0.74, and the BNB model showed a substantial reduction from 0.86 to 0.21. This improvement is consistent with the overall improvements in calibration performance in Table 2, indicating the effectiveness of our proposed post-calibration in reducing calibration error in quantized models.
2025BNB-quantized model, post-calibration proposedCalibration error0.21calibration=soft-prompt post-calibration · quantization=BNB · confidence_subset=incorrect answersQuantized Can Still Be Calibrated: A Unified Framework to Calibration in Quantized Large Language Models
Source quote
L290: 0.85 to 0.74, and the BNB model showed a substantial reduction from 0.86 to 0.21. This improvement is consistent with the overall improvements in calibration performance in Table 2, indicating the effectiveness of our proposed post-calibration in reducing calibration error in quantized models.
2025GPTQ-quantized model, pre-calibration baselineCalibration error0.39calibration=pre-calibration · quantization=GPTQ · confidence_subset=correct answersQuantized Can Still Be Calibrated: A Unified Framework to Calibration in Quantized Large Language Models
Source quote
L287: 2 (a), the GPTQ quantized model’s calibration error decreased from 0.39 to 0.19, while the BNB quantized model’s error reduced from 0.37 to 0.24.
2025GPTQ-quantized model, pre-calibration baselineCalibration error0.85calibration=pre-calibration · quantization=GPTQ · confidence_subset=incorrect answersQuantized Can Still Be Calibrated: A Unified Framework to Calibration in Quantized Large Language Models
Source quote
L290: 0.85 to 0.74, and the BNB model showed a substantial reduction from 0.86 to 0.21. This improvement is consistent with the overall improvements in calibration performance in Table 2, indicating the effectiveness of our proposed post-calibration in reducing calibration error in quantized models.
2025BNB-quantized model, pre-calibration baselineCalibration error0.86calibration=pre-calibration · quantization=BNB · confidence_subset=incorrect answersQuantized Can Still Be Calibrated: A Unified Framework to Calibration in Quantized Large Language Models
Source quote
L290: 0.85 to 0.74, and the BNB model showed a substantial reduction from 0.86 to 0.21. This improvement is consistent with the overall improvements in calibration performance in Table 2, indicating the effectiveness of our proposed post-calibration in reducing calibration error in quantized models.