ADNI

202 papers · 607 extracted observations · classification · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Classification.

46.963.580.196.7201220192026QDA: 66.14 (2012)QDA: 68.0 (2012)TabSeq: 64.44 (2024)TabSeq: 75.13 (2024)GLIM-Net: 77.9 (2024)MST-former (3 scales): 90.3 (2024)ConnectomeDiffuser: 71.25 (2025)MedOrch: 50.35 (2025)MedOrch (o1-mini, best@5): 93.26 (2025)M3D + LGA: 76.7 (2025)RCL: 89.3 (2025)Reinforced Domain Selection: 90.5 (2025)Artemis: 84.3 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 91 of 91 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026scBIT with snRNA data proposedACC3.39%Alzheimer Disease Classification · split: val · 10-fold-cross-validation · modality=fMRI + snRNA · classification=binaryscBIT: Integrating Single-Cell Transcriptomic Data Into fMRI-Based Prediction for Alzheimer's Disease Diagnosis
Source quote
L234: 3.39% in ACC, 5.63% in AUC, 2.74% in SEN, and 9.71% in SPE, and in the five-class classification task of 26.59% in ACC, 7.44% in SPE, 24.98% in REC, 28.97% in PRE, and 26.89% in F1. The enhancements observed in the five-class classification task are substantially greater compared to those in the binary classification task. The reduction in standard deviation in the prediction results also indicates that the inclusion of snRNA data significantly enhances the stability of scBIT's predictions. We conducted an evaluation to determine the impact of integrating different proportions of snRNA data on the predictive performance of scBIT. This assessment involved a systematic introduction of snRNA data at 20% intervals, ranging from 20% to 80%. The results (Fig. 3(d)) clearly demonstrated that the inclusion of incremental amounts of snRNA data significantly improved the accuracy of scBIT in binary classification task. Notably, the average accuracy increased from 0.9431 with 20% snRNA data to 0.9569
2026scBIT with snRNA data proposedACC26.59%Alzheimer Disease Classification · split: val · 10-fold-cross-validation · modality=fMRI + snRNA · classification=five-classscBIT: Integrating Single-Cell Transcriptomic Data Into fMRI-Based Prediction for Alzheimer's Disease Diagnosis
Source quote
L234: 3.39% in ACC, 5.63% in AUC, 2.74% in SEN, and 9.71% in SPE, and in the five-class classification task of 26.59% in ACC, 7.44% in SPE, 24.98% in REC, 28.97% in PRE, and 26.89% in F1. The enhancements observed in the five-class classification task are substantially greater compared to those in the binary classification task. The reduction in standard deviation in the prediction results also indicates that the inclusion of snRNA data significantly enhances the stability of scBIT's predictions. We conducted an evaluation to determine the impact of integrating different proportions of snRNA data on the predictive performance of scBIT. This assessment involved a systematic introduction of snRNA data at 20% intervals, ranging from 20% to 80%. The results (Fig. 3(d)) clearly demonstrated that the inclusion of incremental amounts of snRNA data significantly improved the accuracy of scBIT in binary classification task. Notably, the average accuracy increased from 0.9431 with 20% snRNA data to 0.9569
2026NeuroAlign (Dual-MRI; DFC+SFC+ALFF+FA) proposedaccuracy0.825Mci Classification · split: val · modality=Dual-MRI (DFC+SFC+ALFF+FA) · validation=five-foldNeuroAlign: Hierarchical Multimodal Fusion of Dynamic and Structural Neuroimaging for MCI Analysis
Source quote
L23: \item NeuroAlign achieves 0.825/0.735 accuracy on ADNI/OASIS in multimodal MCI classification.
2025Heter-LBI (proposed method; table label “Ours”) proposedclassification accuracy88.96%Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=1.5TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L490: 88.96%
2025Heter-LBI (proposed method; table label “Ours”) proposedclassification accuracy91.48%Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=3.0TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L491: 91.48%
2025Heter-LBI (proposed method; table label “Ours”) proposedclassification accuracy74.00%Classification · split: val · comparison=MCI-vs-NC · validation=10-fold cross-validation · field-strength=1.5TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L492: 74.00% is enforced with spatial smoothness and non-negativity constraint to learn the lesion features and a dense parameter to additionally learn the procedural bias.
2025SDE-GNN (salient topological features) proposed non-standard sliceBayes Factor for MMSE prediction22.91Mmse Prediction · split: val · population=progressive subjects · transition=HC to MCI/AD · validation=5-fold cross-validation · regression-model=linear mixed-effectsUncovering Alzheimer's Disease Progression via SDE-based Spatio-Temporal Graph Deep Learning on Longitudinal Brain Networks
Source quote
L53: To further investigate the clinical relevance of the identified circuit abnormalities, we examined their relationship with longitudinal AD-related clinical measures, including Mini-Mental State Examination (MMSE) scores and amyloid-beta (A\beta) levels. Using the learned salient topological patterns, we predicted these clinical measures in progressive subjects to assess the functional significance of our identified biomarkers. We first z-score normalized the learned topological features and used them to train a linear mixed-effects regression model, which was evaluated using 5-fold cross-validation. Fig. \ref{fig:regression}(a) presents the predicted versus actual MMSE and A\beta scores across two progression stages in the OASIS-3 cohort. The actual A\beta was calculated by measuring centiloid-scaled standardized uptake value ratios (SUVRs) across relevant cortical regions, with higher values indicating increased A\beta accumulation and thus more severe Alzheimer's disease pathology. Fig. \ref{fig:regression}(b) shows the corresponding results for the ADNI cohort. The actual A\beta represents the concentration of amyloid plaque burden in cerebrospinal fluid (CSF), where smaller values are associated with more severe Alzheimer's disease. The visualizations illustrate the predictive accuracy of our method for two disease transitions: HC to MCI/AD progression and MCI to AD progression. The fit of the regression line and the box plot for longitudinal data further indicate a strong correlation between the ground truth and predicted scores of our method. To statistically validate the significance of our predictions, we conducted Bayes Factor analysis for the correlation. Fig. \ref{fig:regression}(c) summarizes the numerical performance comparison between our method and other brain network-based approaches across all progressive subjects. Our approach consistently achieved the highest Bayes Factors across different clinical contrasts and cohorts, reinforcing the robustness of our biomarker-driven predictions. Specifically, in the OASIS-3 cohort, the Bayes Factor of our method for the HC to MCI/AD transition was 11.05 for MMSE and 3.37 for A\beta, while in the ADNI cohort, it was 22.91 for MMSE and 17.28 for A\beta. Notably, Bayes Factors for the MCI to AD transition in OASIS-3 cohort were generally lower, likely due to fewer progressive subjects and shorter available longitudinal time points. However, the identified circuit biomarkers demonstrated significant predictive performance across all clinical measures, underscoring their strong association with progressive MCI and AD symptoms. These results highlight the potential of our method for tracking neurodegenerative decline and support its applicability for early-stage AD prognosis.
2025SDE-GNN (salient topological features) proposedBayes Factor for Aβ prediction17.28Amyloid Beta Prediction · split: val · population=progressive subjects · transition=HC to MCI/AD · validation=5-fold cross-validation · measurement=cerebrospinal-fluid concentration · regression-model=linear mixed-effectsUncovering Alzheimer's Disease Progression via SDE-based Spatio-Temporal Graph Deep Learning on Longitudinal Brain Networks
Source quote
L53: To further investigate the clinical relevance of the identified circuit abnormalities, we examined their relationship with longitudinal AD-related clinical measures, including Mini-Mental State Examination (MMSE) scores and amyloid-beta (A\beta) levels. Using the learned salient topological patterns, we predicted these clinical measures in progressive subjects to assess the functional significance of our identified biomarkers. We first z-score normalized the learned topological features and used them to train a linear mixed-effects regression model, which was evaluated using 5-fold cross-validation. Fig. \ref{fig:regression}(a) presents the predicted versus actual MMSE and A\beta scores across two progression stages in the OASIS-3 cohort. The actual A\beta was calculated by measuring centiloid-scaled standardized uptake value ratios (SUVRs) across relevant cortical regions, with higher values indicating increased A\beta accumulation and thus more severe Alzheimer's disease pathology. Fig. \ref{fig:regression}(b) shows the corresponding results for the ADNI cohort. The actual A\beta represents the concentration of amyloid plaque burden in cerebrospinal fluid (CSF), where smaller values are associated with more severe Alzheimer's disease. The visualizations illustrate the predictive accuracy of our method for two disease transitions: HC to MCI/AD progression and MCI to AD progression. The fit of the regression line and the box plot for longitudinal data further indicate a strong correlation between the ground truth and predicted scores of our method. To statistically validate the significance of our predictions, we conducted Bayes Factor analysis for the correlation. Fig. \ref{fig:regression}(c) summarizes the numerical performance comparison between our method and other brain network-based approaches across all progressive subjects. Our approach consistently achieved the highest Bayes Factors across different clinical contrasts and cohorts, reinforcing the robustness of our biomarker-driven predictions. Specifically, in the OASIS-3 cohort, the Bayes Factor of our method for the HC to MCI/AD transition was 11.05 for MMSE and 3.37 for A\beta, while in the ADNI cohort, it was 22.91 for MMSE and 17.28 for A\beta. Notably, Bayes Factors for the MCI to AD transition in OASIS-3 cohort were generally lower, likely due to fewer progressive subjects and shorter available longitudinal time points. However, the identified circuit biomarkers demonstrated significant predictive performance across all clinical measures, underscoring their strong association with progressive MCI and AD symptoms. These results highlight the potential of our method for tracking neurodegenerative decline and support its applicability for early-stage AD prognosis.
2025Proposed spatial-temporal transformer (Ours; temporal and spatial blocks) proposedACC89.1Classification · split: val · 5-fold-cv · evaluation=subject-levelClassification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal Transformer
Source quote
L148: 89.1
2025Proposed spatial-temporal transformer (Ours; temporal and spatial blocks) proposedF190.3Classification · split: val · 5-fold-cv · evaluation=subject-levelClassification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal Transformer
Source quote
L152: 90.3 os-FC: original static FC; S/T-only: Using only the spatial/ temporal block
2025Proposed framework with contrastive learning proposedAccuracy improvement9.7%Classification · split: val · 5-fold-cv · component=contrastive-learning · comparison=without-contrastive-learning · evaluation=subject-levelClassification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal Transformer
Source quote
L114: To verify our proposed model, we compare it with other widely used methods in the literature listed in Table 1. Our results outperform most other studies. Furthermore, the proposed method incorporating contrastive learning strategy performs significantly better than the method without contrastive learning strategy on this data, showing an improvement of 9.7% in accuracy and 7.3% in F1 score when contrastive learning is applied.
2025Proposed framework with contrastive learning proposedF1 improvement7.3%Classification · split: val · 5-fold-cv · component=contrastive-learning · comparison=without-contrastive-learning · evaluation=subject-levelClassification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal Transformer
Source quote
L114: To verify our proposed model, we compare it with other widely used methods in the literature listed in Table 1. Our results outperform most other studies. Furthermore, the proposed method incorporating contrastive learning strategy performs significantly better than the method without contrastive learning strategy on this data, showing an improvement of 9.7% in accuracy and 7.3% in F1 score when contrastive learning is applied.
2025SAM-Brain3D + HyDA (k=28) proposedAccuracy (ACC)88.34%Medical Image Classification · split: val · cross-validation=5-fold · hypergraph-nearest-neighbor-k=28Brain foundation models with hypergraph dynamic adapter for brain disease analysis
Source quote
L357: SAM-Brain3D + HyDA (k=28) │ 88.34 │ 71.70 │ 97.86 │ 62.19 │ 84.29
2025BrainMAP proposedACC82.3%Disease Classification · split: val · 5-fold-cross-validation · CNA=64 · GIAC=32BrainMAP: Multimodal Graph Learning For Efficient Brain Disease Localization
Source quote
L215: 82.3 │ 91.5
2025BrainMAP proposedAUC91.5%Disease Classification · split: val · 5-fold-cross-validation · CNA=64 · GIAC=32BrainMAP: Multimodal Graph Learning For Efficient Brain Disease Localization
Source quote
L215: 82.3 │ 91.5
2025BrainMAP proposedTime0.0243 seconds per epochDisease Classification · split: val · 5-fold-cross-validation · CNA=64 · GIAC=32 · runtime-unit=seconds per epochBrainMAP: Multimodal Graph Learning For Efficient Brain Disease Localization
Source quote
L216: 0.0243 │ 1.5 GB
2025NSA-Flow (NSA) proposedAUC0.765Multi Class Classification · split: val · classifier=random-forest · evaluation=two runs of 4-fold cross-validationNon-Negative Stiefel Approximating Flow: Orthogonalish Matrix Optimization for Interpretable Embeddings
Source quote
L838: Multi-class │ NSA │ {\itshape {0.765}}
2025NSA-Flow (NSA) proposedAUC0.675Binary Classification · split: val · classifier=random-forest · comparison=CN vs MCI · evaluation=two runs of 4-fold cross-validationNon-Negative Stiefel Approximating Flow: Orthogonalish Matrix Optimization for Interpretable Embeddings
Source quote
L829: CN vs MCI │ NSA │ 0.663 │ 0.681 │ 0.772 │ 0.586 │ {\itshape {0.675}}
2025IFA (LDIS enabled) ablationHM82.4Image Classification · split: val · 0-shot · evaluation=five-fold cross-validation · unseen-class=MCIGeneralized Zero-Shot Classification via Semantics-Free Inter-Class Feature Generation
Source quote
L482: 82.4
2025S-only (spatial block only) ablationACC76.6Classification · split: val · 5-fold-cv · ablation=spatial-block-only · evaluation=subject-levelClassification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal Transformer
Source quote
L136: 76.6
2025S-only (spatial block only) ablationF173.1Classification · split: val · 5-fold-cv · ablation=spatial-block-only · evaluation=subject-levelClassification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal Transformer
Source quote
L140: 73.1
2025GSplit LBI baselineclassification accuracy88.31%Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=1.5TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L486: 88.31%
2025GSplit LBI baselineclassification accuracy88.64%Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=3.0TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L487: 88.64%
2025SVM baselineclassification accuracy73.50%Classification · split: val · comparison=MCI-vs-NC · validation=10-fold cross-validation · field-strength=1.5TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L468: 73.50%
2025PCA baselineAUC0.719Multi Class Classification · split: val · classifier=random-forest · evaluation=two runs of 4-fold cross-validationNon-Negative Stiefel Approximating Flow: Orthogonalish Matrix Optimization for Interpretable Embeddings
Source quote
L839: Multi-class │ PCA │ {\itshape {0.719}}
2025PCA baselineAUC0.595Binary Classification · split: val · classifier=random-forest · comparison=CN vs MCI · evaluation=two runs of 4-fold cross-validationNon-Negative Stiefel Approximating Flow: Orthogonalish Matrix Optimization for Interpretable Embeddings
Source quote
L830: CN vs MCI │ PCA │ 0.637 │ 0.645 │ 0.584 │ 0.514 │ {\itshape {0.595}}
2024Ours (inv) proposedACC81Image Classification · split: val · evaluation=5-fold cross-validation · invariance=scannerPooling Image Datasets with Multiple Covariate Shift and Imbalance
Source quote
L580: Ours (inv) │ 81{\scriptstyle(2.3)} │ {\bf 02}{\scriptstyle(2.4)} │ 52{\scriptstyle(2.0)} │ {\bf 86}{\scriptstyle(8.0)} │ {\bf 34}{\scriptstyle(01.2)} │ 45{\scriptstyle(04.2)}
2024Naive baselineACC80Image Classification · split: val · setting=pooled data without pre/post processing · evaluation=5-fold cross-validationPooling Image Datasets with Multiple Covariate Shift and Imbalance
Source quote
L573: Naive │ 80{\scriptstyle(2.6)} │ 27{\scriptstyle(1.6)} │ 59{\scriptstyle(2.9)} │ 83{\scriptstyle(4.4)} │ 90{\scriptstyle(08.7)} │ 49{\scriptstyle(08.4)}
2023BSFL (proposed; listed as “Ours”; GCN classifier) proposed non-standard sliceAUC93.88%Binary Classification · split: val · classifier=GCN · comparison=SMC-vs-NC · modalities=DTI-and-fMRI · validation=10-fold-cross-validationBrain Structure-Function Fusing Representation Learning using Adversarial Decomposed-VAE for Analyzing MCI
Source quote
L274: Ours │ {\bfseries 85.97} │ {\bfseries 96.34} │ {\bfseries 75.61} │ {\bfseries 93.88} │ {\bfseries 90.85} │ {\bfseries 93.90} │ {\bfseries 87.80} │ {\bfseries 97.85} │ {\bfseries 94.30} │ {\bfseries 93.42} │ 95.12 │ {\bfseries 98.12}
2023BSFL (proposed; listed as “Ours”; GCN classifier) proposed non-standard sliceAUC98.12%Binary Classification · split: val · classifier=GCN · comparison=LMCI-vs-NC · modalities=DTI-and-fMRI · validation=10-fold-cross-validationBrain Structure-Function Fusing Representation Learning using Adversarial Decomposed-VAE for Analyzing MCI
Source quote
L274: Ours │ {\bfseries 85.97} │ {\bfseries 96.34} │ {\bfseries 75.61} │ {\bfseries 93.88} │ {\bfseries 90.85} │ {\bfseries 93.90} │ {\bfseries 87.80} │ {\bfseries 97.85} │ {\bfseries 94.30} │ {\bfseries 93.42} │ 95.12 │ {\bfseries 98.12}
2023BDHT proposedMAE0.0092Time Series Reconstruction · split: val · input=ROI-based time series · evaluation=5-fold cross-validationBDHT: Generative AI Enables Causality Analysis for Mild Cognitive Impairment
Source quote
L227: The output of the proposed model is the denoised time series and the effective connectivity. We evaluated the performance of the generated time series. The details of generating one ROI-based time series by our model are displayed in Fig.~\ref{fig4}. As the time steps decrease, the Gaussian noise is gradually transformed into a clean time series. We select two other generative frameworks for comparison, including the variational autoencoder (VAE) and the generative adversarial network (GAN). These two frameworks accept both SC and rough time series by designing graph convolutional networks (GCN). As shown in Fig.~\ref{fig5}, the VAE-based or GAN-based models have larger reconstructed errors, while our model achieves the minimum mean value for MAE and RMSE with 0.0092 and 0.0121, respectively. The standard error of our model is also lower than that of the other two models.
2023BDHT proposedRMSE0.0121Time Series Reconstruction · split: val · input=ROI-based time series · evaluation=5-fold cross-validationBDHT: Generative AI Enables Causality Analysis for Mild Cognitive Impairment
Source quote
L227: The output of the proposed model is the denoised time series and the effective connectivity. We evaluated the performance of the generated time series. The details of generating one ROI-based time series by our model are displayed in Fig.~\ref{fig4}. As the time steps decrease, the Gaussian noise is gradually transformed into a clean time series. We select two other generative frameworks for comparison, including the variational autoencoder (VAE) and the generative adversarial network (GAN). These two frameworks accept both SC and rough time series by designing graph convolutional networks (GCN). As shown in Fig.~\ref{fig5}, the VAE-based or GAN-based models have larger reconstructed errors, while our model achieves the minimum mean value for MAE and RMSE with 0.0092 and 0.0121, respectively. The standard error of our model is also lower than that of the other two models.
2023WSEK (weighted subspace exponential kernel) proposedaverage classification accuracy79%Classification · split: val · modality=fMRI · classifier=KSTM · rank-selection=best average over Tucker ranks 1–10A weighted subspace exponential kernel for support tensor machines
Source quote
L381: (79% for ADNI and 64% for ADHD) compared to other state of the art tensor kernels. We note that the accuracy of the subspace kernel improves for higher ranks in the ADHD dataset and is then similar to that of WSEK but this choice of rank is very high for a low-rank truncation method. On the other hand, our proposed kernel gives good classification accuracy already at rank 2. The Gaussian kernel was computed for different Tucker approximations of the full tensor. Using the full tensor in the computation of the kernel did not improve the accuracy. As in~\cite{KourJMLR}, the DuSK kernel was computed using a CP approximation of the full tensor (CP-DuSK), because computing the Tucker decomposition and then converting to CP yielded high CP ranks and DuSK was too slow.
2023GBDM (GCN classifier) baseline non-standard sliceAUC81.81%Binary Classification · split: val · classifier=GCN · comparison=SMC-vs-NC · modalities=DTI-and-fMRI · validation=10-fold-cross-validationBrain Structure-Function Fusing Representation Learning using Adversarial Decomposed-VAE for Analyzing MCI
Source quote
L273: GBDM │ 81.70 │ 89.02 │ 74.39 │ 81.81 │ 86.58 │ 89.02 │ 84.14 │ 89.75 │ 91.13 │ 86.84 │ 95.12 │ 89.68
2023GBDM (GCN classifier) baseline non-standard sliceAUC89.75%Binary Classification · split: val · classifier=GCN · comparison=EMCI-vs-NC · modalities=DTI-and-fMRI · validation=10-fold-cross-validationBrain Structure-Function Fusing Representation Learning using Adversarial Decomposed-VAE for Analyzing MCI
Source quote
L273: GBDM │ 81.70 │ 89.02 │ 74.39 │ 81.81 │ 86.58 │ 89.02 │ 84.14 │ 89.75 │ 91.13 │ 86.84 │ 95.12 │ 89.68
2023GBDM (GCN classifier) baseline non-standard sliceAUC89.68%Binary Classification · split: val · classifier=GCN · comparison=LMCI-vs-NC · modalities=DTI-and-fMRI · validation=10-fold-cross-validationBrain Structure-Function Fusing Representation Learning using Adversarial Decomposed-VAE for Analyzing MCI
Source quote
L273: GBDM │ 81.70 │ 89.02 │ 74.39 │ 81.81 │ 86.58 │ 89.02 │ 84.14 │ 89.75 │ 91.13 │ 86.84 │ 95.12 │ 89.68
2022BrainFormer (fMRI-only) proposedclassification accuracy95.3%Brain Disease Classification · split: val · 5-fold-cross-validation · input=single-volume fMRI · classes=AD vs CNFirst Glance Diagnosis: Brain Disease Classification with Single fMRI Volume
Source quote
L337: fMRI │ 97.2 │ 95.3 │ 72.0 │ 72.5 │ 81.2
2022ETLN^E (ECN-only)ACC (prediction accuracy)73.47Classification · split: valA Structure-Guided Effective and Temporal-Lag Connectivity Network for Revealing Brain Disorder Mechanisms
Source quote
L175: ETLN (E) │ 74.31 │ 70.59 │ 77.59 │ 72.00 │ 78.02 │ 82.35 │ 72.50 │ 80.77 │ 73.47 │ 82.76 │ 60.00 │ 78.69
2022LRACC (prediction accuracy)67.35Classification · split: valA Structure-Guided Effective and Temporal-Lag Connectivity Network for Revealing Brain Disorder Mechanisms
Source quote
L169: LR │ 69.72 │ 66.67 │ 72.41 │ 67.33 │ 74.73 │ 80.39 │ 67.50 │ 78.10 │ 67.35 │ 75.86 │ 55.00 │ 73.33
2022Layer-wise Relevance Propagation (LRP) baselineDice overlap0.502Brain Region Localization · split: val · smoothing=7 mm FWHMDeep neural network heatmaps capture Alzheimer's disease patterns reported in a large meta-analysis of neuroimaging studies
Source quote
L161: Figure \ref{dice} reports all the Dice measured between the heatmaps and the meta-analysis map. The best Dice overlap measured for LRP, IG, GGC, and SVM was 0.502 when the LRP heatmap was smoothed by a 7 mm FWHM Gaussian smoothing, 0.550 for the IG heatmap with a 4 mm smoothing, 0.540 for GGC with an 8 mm smoothing and 0.479 for the SVM heatmap with a 12 mm smoothing. The heatmaps with the best overlaps with the meta-analysis are shown in Figure \ref{plot}. Figure \ref{plot2} displays the unsmoothed heatmaps. The LRP heatmaps select more regions than the other maps and appear to be noisier. On the other hand, IG heatmaps have a better focus on the regions highlighted by the meta-analysis, but the unsmoothed IG map presents an unrealistic scatter. IG produced a map that was simultaneously more relevant than the LRP heatmap and less scattered than the GGC heatmap. In comparison, the unsmoothed SVM heatmap covers most of the grey matter. The linear SVM produced slightly larger weight amplitudes in the regions relevant for the diagnosis, but an aggressive smoothing was required to make this effect emerge in Figure \ref{plot}.
2022Integrated Gradients (IG) baselineDice overlap0.550Brain Region Localization · split: val · smoothing=4 mm FWHMDeep neural network heatmaps capture Alzheimer's disease patterns reported in a large meta-analysis of neuroimaging studies
Source quote
L161: Figure \ref{dice} reports all the Dice measured between the heatmaps and the meta-analysis map. The best Dice overlap measured for LRP, IG, GGC, and SVM was 0.502 when the LRP heatmap was smoothed by a 7 mm FWHM Gaussian smoothing, 0.550 for the IG heatmap with a 4 mm smoothing, 0.540 for GGC with an 8 mm smoothing and 0.479 for the SVM heatmap with a 12 mm smoothing. The heatmaps with the best overlaps with the meta-analysis are shown in Figure \ref{plot}. Figure \ref{plot2} displays the unsmoothed heatmaps. The LRP heatmaps select more regions than the other maps and appear to be noisier. On the other hand, IG heatmaps have a better focus on the regions highlighted by the meta-analysis, but the unsmoothed IG map presents an unrealistic scatter. IG produced a map that was simultaneously more relevant than the LRP heatmap and less scattered than the GGC heatmap. In comparison, the unsmoothed SVM heatmap covers most of the grey matter. The linear SVM produced slightly larger weight amplitudes in the regions relevant for the diagnosis, but an aggressive smoothing was required to make this effect emerge in Figure \ref{plot}.
2022Guided Grad-CAM (GGC) baselineDice overlap0.540Brain Region Localization · split: val · smoothing=8 mm FWHMDeep neural network heatmaps capture Alzheimer's disease patterns reported in a large meta-analysis of neuroimaging studies
Source quote
L161: Figure \ref{dice} reports all the Dice measured between the heatmaps and the meta-analysis map. The best Dice overlap measured for LRP, IG, GGC, and SVM was 0.502 when the LRP heatmap was smoothed by a 7 mm FWHM Gaussian smoothing, 0.550 for the IG heatmap with a 4 mm smoothing, 0.540 for GGC with an 8 mm smoothing and 0.479 for the SVM heatmap with a 12 mm smoothing. The heatmaps with the best overlaps with the meta-analysis are shown in Figure \ref{plot}. Figure \ref{plot2} displays the unsmoothed heatmaps. The LRP heatmaps select more regions than the other maps and appear to be noisier. On the other hand, IG heatmaps have a better focus on the regions highlighted by the meta-analysis, but the unsmoothed IG map presents an unrealistic scatter. IG produced a map that was simultaneously more relevant than the LRP heatmap and less scattered than the GGC heatmap. In comparison, the unsmoothed SVM heatmap covers most of the grey matter. The linear SVM produced slightly larger weight amplitudes in the regions relevant for the diagnosis, but an aggressive smoothing was required to make this effect emerge in Figure \ref{plot}.
2021DecGAN (t=2, k=5) proposed non-standard sliceACC92.59%Binary Classification · split: val · k=5 · t=2 · classes=AD vs NC · validation=five-foldDecGAN: Decoupling Generative Adversarial Network detecting abnormal neural circuits for Alzheimer's disease
Source quote
L354: The top two highest ACC value of 92.59% and 88.90% are achieved at (t,k)=(2,5) and (t,k)=(1,8).
2021DecGAN (t=1, k=8) proposed non-standard sliceACC88.90%Binary Classification · split: val · k=8 · t=1 · classes=AD vs NC · validation=five-foldDecGAN: Decoupling Generative Adversarial Network detecting abnormal neural circuits for Alzheimer's disease
Source quote
L354: The top two highest ACC value of 92.59% and 88.90% are achieved at (t,k)=(2,5) and (t,k)=(1,8).
2021FedNI proposedAccuracy0.758Disease Prediction · split: val · semi-supervised · evaluation=5-fold cross-validation repeated 5 times · institutions=5 · labeled-rate=80%FedNI: Federated Graph Learning with Network Inpainting for Population-Based Disease Prediction
Source quote
L446: ~~\multirow{2}{*}{\textbf{\texttt{FedNI}} (ours)} │ 0.667 │ 0.663 │ 0.647 │ 0.640 │ 0.637 │ 0.758 │ 0.754 │ 0.725 │ 0.721 │ 0.717
2021SVM on priori brain networks baseline non-standard sliceACC77.77%Binary Classification · split: val · input=priori brain networks · classes=NC vs AD · classifier=SVM · validation=five-foldDecGAN: Decoupling Generative Adversarial Network detecting abnormal neural circuits for Alzheimer's disease
Source quote
L457: SVM │ Priori brain networks │ 72.41% │ 73.33% │ 71.42% │ 73.33% │ 76.19% │ 86.66% │ 50.00% │ 83.87% │ 77.77% │ 87.50% │ 63.63% │ 82.35%
2021SVM on reconstruction brain networks baseline non-standard sliceACC85.18%Binary Classification · split: val · input=DecGAN reconstruction brain networks · classes=NC vs AD · classifier=SVM · validation=five-foldDecGAN: Decoupling Generative Adversarial Network detecting abnormal neural circuits for Alzheimer's disease
Source quote
L458: Reconstruction brain networks │ 75.86% │ 80.00% │ 71.42% │ 77.41% │ 80.95% │ 86.66% │ 66.66% │ 86.66% │ 85.18% │ 75.00% │ 100.00% │ 85.71%
2021GCN on priori brain networks baseline non-standard sliceACC82.75%Binary Classification · split: val · input=priori brain networks · classes=NC vs EMCI · classifier=GCN · validation=five-foldDecGAN: Decoupling Generative Adversarial Network detecting abnormal neural circuits for Alzheimer's disease
Source quote
L463: GCN │ Priori brain networks │ 82.75% │ 86.66% │ 78.57% │ 83.87% │ 80.95% │ 73.33% │ 100.00% │ 84.61% │ 81.48% │ 81.25% │ 81.80% │ 83.87%
2021GCN on reconstruction brain networks baseline non-standard sliceACC86.20%Binary Classification · split: val · input=DecGAN reconstruction brain networks · classes=NC vs EMCI · classifier=GCN · validation=five-foldDecGAN: Decoupling Generative Adversarial Network detecting abnormal neural circuits for Alzheimer's disease
Source quote
L464: Reconstruction brain networks │ 86.20% │ 86.66% │ 85.71% │ 86.66% │ 85.71% │ 80.00% │ 100.00% │ 88.88% │ 85.18% │ 81.25% │ 90.91% │ 86.66%
2021FedSage+ baselineAccuracy0.751Disease Prediction · split: val · semi-supervised · evaluation=5-fold cross-validation repeated 5 times · institutions=5 · labeled-rate=80%FedNI: Federated Graph Learning with Network Inpainting for Population-Based Disease Prediction
Source quote
L443: ~~\multirow{2}{*}{FedSage+} │ 0.658 │ 0.655 │ 0.641 │ 0.627 │ 0.626 │ 0.751 │ 0.744 │ 0.722 │ 0.699 │ 0.700
2020TT-MMK proposedAverage classification accuracy73%Classification · split: val · 5-fold-cross-validation · data=resting-state fMRI · classes=AD+MCI vs normal controls · subjects=33 · repetitions=50Efficient Structure-preserving Support Tensor Train Machine
Source quote
L515: TT-MMK │ 73 │ 64 │ 99 │ 99
2020DOP (depth-first-based ordinal pattern kernel) proposedClassification accuracy86.90%Brain Network Classification · split: val · atlas=AAL-90 · validation=leave-one-out · diagnosis-contrast=AD-vs-NCOrdinal Pattern Kernel for Brain Connectivity Network Classification
Source quote
L216: DOP │ 81.21 │ 86.90 │ 83.84 │ 80.0 │ 83.12 }
2020DOP (depth-first-based ordinal pattern kernel) proposedClassification accuracy83.84%Brain Network Classification · split: val · atlas=AAL-90 · validation=leave-one-out · diagnosis-contrast=EMCI-vs-LMCIOrdinal Pattern Kernel for Brain Connectivity Network Classification
Source quote
L216: DOP │ 81.21 │ 86.90 │ 83.84 │ 80.0 │ 83.12 }
2020DOP (depth-first-based ordinal pattern kernel) proposedClassification accuracy80.0%Brain Network Classification · split: val · atlas=AAL-90 · validation=leave-one-out · diagnosis-contrast=EMCI-vs-ADOrdinal Pattern Kernel for Brain Connectivity Network Classification
Source quote
L216: DOP │ 81.21 │ 86.90 │ 83.84 │ 80.0 │ 83.12 }
2020DOP (depth-first-based ordinal pattern kernel) proposedClassification accuracy83.12%Brain Network Classification · split: val · atlas=AAL-90 · validation=leave-one-out · diagnosis-contrast=LMCI-vs-ADOrdinal Pattern Kernel for Brain Connectivity Network Classification
Source quote
L216: DOP │ 81.21 │ 86.90 │ 83.84 │ 80.0 │ 83.12 }
2020ASMFS proposedAUC0.9703Disease Classification · split: val · 10-fold-cross-validation · cohort=51 AD; 52 NC · modalities=MRI+FDG-PETASMFS: Adaptive-Similarity-based Multi-modality Feature Selection for Classification of Alzheimer's Disease
Source quote
L612: Table 2 lists the classification results of AD vs. NC produced by seven methods. The standard deviations are given and the best results are denoted in bold in Table 2. As observed, our proposed method (ASMFS) consistently achieves the best performance from all the methods in comparison. Specifically, ASMFS achieves the accuracy of 96.76%, the sensitivity of 96.1%, the specificity of 97.47%, the AUC of 0.9703 and the F1 Score of 96.63. Among the three multi-modality feature selection methods, i.e., MTFS, M2TFS and ASMFS, we can find that over 95% accuracy is achieved by M2TFS and ASMFS, indicating that maintaining inter-modality information is effective for feature selection. Furthermore, compared with
2020ASMFS proposedF1 Score96.63Disease Classification · split: val · 10-fold-cross-validation · cohort=51 AD; 52 NC · modalities=MRI+FDG-PETASMFS: Adaptive-Similarity-based Multi-modality Feature Selection for Classification of Alzheimer's Disease
Source quote
L612: Table 2 lists the classification results of AD vs. NC produced by seven methods. The standard deviations are given and the best results are denoted in bold in Table 2. As observed, our proposed method (ASMFS) consistently achieves the best performance from all the methods in comparison. Specifically, ASMFS achieves the accuracy of 96.76%, the sensitivity of 96.1%, the specificity of 97.47%, the AUC of 0.9703 and the F1 Score of 96.63. Among the three multi-modality feature selection methods, i.e., MTFS, M2TFS and ASMFS, we can find that over 95% accuracy is achieved by M2TFS and ASMFS, indicating that maintaining inter-modality information is effective for feature selection. Furthermore, compared with
2020Improved MMK baselineAverage classification accuracy71%Classification · split: val · 5-fold-cross-validation · data=resting-state fMRI · classes=AD+MCI vs normal controls · subjects=33 · repetitions=50Efficient Structure-preserving Support Tensor Train Machine
Source quote
L514: Improved MMK │ 71 │ 61 │ 94 │ 98
2020PM (Pyramid Match kernel) baselineClassification accuracy79.87%Brain Network Classification · split: val · atlas=AAL-90 · validation=leave-one-out · diagnosis-contrast=MCI-vs-NCOrdinal Pattern Kernel for Brain Connectivity Network Classification
Source quote
L212: PM │ 79.87 │ 72.62 │ 75.76 │ 74.44 │ 75.32
2019sGP(VIS) proposedmean absolute error (MAE)0.32Forecasting · split: val · fine-tuned · visit-filter=existing visits only · cross-validation=10-fold subject-independent · forecast-horizon=6, 12, 18, and 24 months · metric-aggregation=averaged across four forecasting stepsMeta-Weighted Gaussian Process Experts for Personalized Forecasting of AD Cognitive Changes
Source quote
L168: Table 1 compares the evaluation metrics for the model settings described above. By comparing different population-level GP models, we note that simple smoothing of the previous ADAS-Cog13 score (y_t) using sGP(VIS) is quite effective. We attribute this to the fact that the target scores from the consequent visits are highly correlated. Compared to the model free approach, Base (y_t), which forecasts by "carrying forward" the current score, we note that sGP(VIS) takes advantage of the GP's smoothing property, effectively leveraging the labels (i.e. ADAS-Cog13 scores) from the training population. This results in average error reduction of 0.32 over the four time steps.
2019MGNN (proposed multi-resolution graph neural network) proposedAccuracy0.774Alzheimer Disease Classification · split: val · 3-fold-cross-validation · classes=2 · selection=best results across multiple settings · class-grouping=pre-clinical AD (CN+EMCI) vs prodromal AD (LMCI+AD)Learning Multi-resolution Graph Edge Embedding for Discovering Brain Network Dysfunction in Neurological Disorders
Source quote
L1081: MGNN (ours) │ {\bf 0.774} │ {\bf 0.772} │ {\bf 0.774}
2019MGNN (proposed multi-resolution graph neural network) proposedwPrecision0.772Alzheimer Disease Classification · split: val · 3-fold-cross-validation · classes=2 · selection=best results across multiple settings · class-grouping=pre-clinical AD (CN+EMCI) vs prodromal AD (LMCI+AD)Learning Multi-resolution Graph Edge Embedding for Discovering Brain Network Dysfunction in Neurological Disorders
Source quote
L1081: MGNN (ours) │ {\bf 0.774} │ {\bf 0.772} │ {\bf 0.774}
2019MGNN (proposed multi-resolution graph neural network) proposedwRecall0.774Alzheimer Disease Classification · split: val · 3-fold-cross-validation · classes=2 · selection=best results across multiple settings · class-grouping=pre-clinical AD (CN+EMCI) vs prodromal AD (LMCI+AD)Learning Multi-resolution Graph Edge Embedding for Discovering Brain Network Dysfunction in Neurological Disorders
Source quote
L1081: MGNN (ours) │ {\bf 0.774} │ {\bf 0.772} │ {\bf 0.774}
2019Proposed two-stage 3D FCN with enhancement mask (α=0.1) proposedDSC0.897Medical Image Segmentation · split: val · hemisphere=left · validation_protocol=10-fold cross-validation · enhancement_mask_alpha=0.1Enhancement Mask for Hippocampus Detection and Segmentation
Source quote
L381: Ours │ \begin{tabular}[c]{@{}l@{}}0.897/0.900 │ \begin{tabular}[c]{@{}l@{}}0.798/0.813 │ \begin{tabular}[c]{@{}l@{}}0.892/0.919 │ \begin{tabular}[c]{@{}l@{}}0.904/0.882
2019Proposed two-stage 3D FCN with enhancement mask (α=0.1) proposedDSC0.900Medical Image Segmentation · split: val · hemisphere=right · validation_protocol=10-fold cross-validation · enhancement_mask_alpha=0.1Enhancement Mask for Hippocampus Detection and Segmentation
Source quote
L381: Ours │ \begin{tabular}[c]{@{}l@{}}0.897/0.900 │ \begin{tabular}[c]{@{}l@{}}0.798/0.813 │ \begin{tabular}[c]{@{}l@{}}0.892/0.919 │ \begin{tabular}[c]{@{}l@{}}0.904/0.882
2019Linear SVM using morphological age and disease score proposedMean classification accuracy0.59Classification · split: val · classes=MCI stable vs MCI converters · classifier=linear SVM · validation=10-fold cross-validationA model of brain morphological changes related to aging and Alzheimer's disease from cross-sectional assessments
Source quote
L291: We also perform a simple linear classification task between the MCIs and MCIc groups using this two cross-sectional markers. A SVM linear classifier is fitted to the full data-set to perform the binary classification\footnote{The classification task was performed using the SVC module of the scikit-learn python library~\citep{scikit-learn}}. The error penalty weights are adjusted between the two classes to balance the trade-off between false positive and false negative rate. The mean classification accuracy using a 10-folds cross-validation scheme is equal to 0.59. The linear decision function is equivalent to the projection on the SVF v_A - 0.003 v_D, so the differences between MCIs and MCIc subjects is, in our model, only associated with the aging trajectory while the disease specific changes do not seem to have an impact before the conversion. For comparison, for the same experiment between CN and AD, the linear classifier corresponds to the projection on v_A + 0.49 v_D so approximately (v-bn + v-ad) / 2, i.e. the mean evolution of the whole population. Of course, in both cases we do not reach the performance of state-of-the-art dedicated algorithm but it allows us to see how both markers are associated with the diagnosis. Moreover this discriminant approach could be extended by using information in a subset of targeted areas.
2019Segmentation Network without enhancement mask ablationDSC0.863Medical Image Segmentation · split: val · enhancement_mask=absentEnhancement Mask for Hippocampus Detection and Segmentation
Source quote
L348: without mask gain 0.863. The model with the enhancement mask performs better than them with 0.897.
2019Proposal Network ablationDSC0.810Medical Image Segmentation · split: val · component=proposal networkEnhancement Mask for Hippocampus Detection and Segmentation
Source quote
L347: As we observe in Fig.~\ref{fig:self_comp}, the proposal network has only 0.810 accuracy in DSC and the segmentation network
2019Path-Based Label Fusion (PBLF) baselineDSC0.879Medical Image Segmentation · split: val · hemisphere=left · validation_protocol=10-fold cross-validationEnhancement Mask for Hippocampus Detection and Segmentation
Source quote
L380: PBLF\cite{Wang2018Patch} │ \begin{tabular}[c]{@{}l@{}}0.879/0.889 │ \begin{tabular}[c]{@{}l@{}}0.773/0.789 │ \begin{tabular}[c]{@{}l@{}}0.903/0.914 │ \begin{tabular}[c]{@{}l@{}}0.879/0.889
2019Path-Based Label Fusion (PBLF) baselineDSC0.889Medical Image Segmentation · split: val · hemisphere=right · validation_protocol=10-fold cross-validationEnhancement Mask for Hippocampus Detection and Segmentation
Source quote
L380: PBLF\cite{Wang2018Patch} │ \begin{tabular}[c]{@{}l@{}}0.879/0.889 │ \begin{tabular}[c]{@{}l@{}}0.773/0.789 │ \begin{tabular}[c]{@{}l@{}}0.903/0.914 │ \begin{tabular}[c]{@{}l@{}}0.879/0.889
2018MATCH-Net without clinician input ablationAUROC0.962Survival Analysis · split: val · evaluation=five-fold cross-validation · clinician-input=none · prediction-horizon=0.5 yearsMATCH-Net: Dynamic Prediction in Survival Analysis using Convolutional Neural Networks
Source quote
L61: {} │ {\tau} │ {Match-Net} │ {S-TCN} │ {S-MLP} │ {FCN} │ {D-Atlas} │ {RNN} │ {MLP} │ {JM} │ {LM} auroc │ 0.5 │ 0.962~ │ 0.961~ │ 0.959~ │ 0.954~ │ 0.959~ │ 0.949* │ 0.948* │ 0.913* │ 0.909*
2018MATCH-Net without clinician input ablationAUROC0.942Survival Analysis · split: val · evaluation=five-fold cross-validation · clinician-input=none · prediction-horizon=1.0 yearsMATCH-Net: Dynamic Prediction in Survival Analysis using Convolutional Neural Networks
Source quote
L62: 1.0 │ 0.942~ │ 0.941~ │ 0.932~ │ 0.930~ │ 0.929~ │ 0.930~ │ 0.930~ │ 0.917* │ 0.914*
2018Brain Surface AreaCorrectness rate56.67%Disease Classification · split: val · cohort=30 AD patients and 30 healthy controls · method=SVM · feature=cortical surface area · validation=10-fold cross-validationBrain Morphometry Analysis with Surface Foliation Theory
Source quote
L216: Brain Surface Area │ 56.67%
2018Brain Mean CurvatureCorrectness rate55.00%Disease Classification · split: val · cohort=30 AD patients and 30 healthy controls · method=SVM · feature=cortical surface mean curvature · validation=10-fold cross-validationBrain Morphometry Analysis with Surface Foliation Theory
Source quote
L217: Brain Mean Curvature │ 55.00%
2018S-TCN baselineAUROC0.961Survival Analysis · split: val · evaluation=five-fold cross-validation · prediction-horizon=0.5 yearsMATCH-Net: Dynamic Prediction in Survival Analysis using Convolutional Neural Networks
Source quote
L61: {} │ {\tau} │ {Match-Net} │ {S-TCN} │ {S-MLP} │ {FCN} │ {D-Atlas} │ {RNN} │ {MLP} │ {JM} │ {LM} auroc │ 0.5 │ 0.962~ │ 0.961~ │ 0.959~ │ 0.954~ │ 0.959~ │ 0.949* │ 0.948* │ 0.913* │ 0.909*
2018S-TCN baselineAUROC0.941Survival Analysis · split: val · evaluation=five-fold cross-validation · prediction-horizon=1.0 yearsMATCH-Net: Dynamic Prediction in Survival Analysis using Convolutional Neural Networks
Source quote
L62: 1.0 │ 0.942~ │ 0.941~ │ 0.932~ │ 0.930~ │ 0.929~ │ 0.930~ │ 0.930~ │ 0.917* │ 0.914*
2017GCN (population graph) proposedaccuracy77%Disease Progression Prediction · split: val · seeds=10 · prediction=MCI-to-AD conversion · cross-validation=10-fold stratified; subject acquisitions kept togetherSpectral Graph Convolutions for Population-based Disease Prediction
Source quote
L78: For both databases, we observe a significant (p<0.05) increase both in terms of accuracy and area under curve using our proposed method, with respect to the competing methods. The random support yields equivalent or worse results to the linear classifier. For ABIDE, we obtain an average accuracy of 69.5%, outperforming the recent state of the art (66.8%) \cite{abraham2016deriving}. Results obtained for the ADNI database show a large increase in performance with respect to the competing methods, with an average accuracy of 77% on par with state of the art results \cite{tong2016}, corresponding to a 10% increase over a standard linear classifier.
2014Proposed method (MPC: MRI+PET+CSF) proposedACC (accuracy)95.9%Binary Classification · split: val · data=baseline · modalities=MRI+PET+CSF · validation=10-fold cross-validation repeated 10 timesMatrix-Similarity Based Loss Function and Feature Selection for Alzheimer's Disease Diagnosis
Source quote
L243: MP and MPC were better than the same methods with single-modality data such as MRI and PET. Also, the classification performance by MPC was generally better than MP. For example, in the discrimination between AD and NC, the proposed method with MPC achieved the classification accuracy of 95.9%, sensitivity of 95.7%, specificity of 98.6%, and AUC of 98.8%, while the best performance among other competing methods with single-modality data was 93.8% (ACC),
2014Proposed method (MPC: MRI+PET+CSF) proposedSEN (sensitivity)95.7%Binary Classification · split: val · data=baseline · modalities=MRI+PET+CSF · validation=10-fold cross-validation repeated 10 timesMatrix-Similarity Based Loss Function and Feature Selection for Alzheimer's Disease Diagnosis
Source quote
L243: MP and MPC were better than the same methods with single-modality data such as MRI and PET. Also, the classification performance by MPC was generally better than MP. For example, in the discrimination between AD and NC, the proposed method with MPC achieved the classification accuracy of 95.9%, sensitivity of 95.7%, specificity of 98.6%, and AUC of 98.8%, while the best performance among other competing methods with single-modality data was 93.8% (ACC),
2014Proposed method (MPC: MRI+PET+CSF) proposedSPE (specificity)98.6%Binary Classification · split: val · data=baseline · modalities=MRI+PET+CSF · validation=10-fold cross-validation repeated 10 timesMatrix-Similarity Based Loss Function and Feature Selection for Alzheimer's Disease Diagnosis
Source quote
L243: MP and MPC were better than the same methods with single-modality data such as MRI and PET. Also, the classification performance by MPC was generally better than MP. For example, in the discrimination between AD and NC, the proposed method with MPC achieved the classification accuracy of 95.9%, sensitivity of 95.7%, specificity of 98.6%, and AUC of 98.8%, while the best performance among other competing methods with single-modality data was 93.8% (ACC),
2014Proposed method (MPC: MRI+PET+CSF) proposedAUC98.8%Binary Classification · split: val · data=baseline · modalities=MRI+PET+CSF · validation=10-fold cross-validation repeated 10 timesMatrix-Similarity Based Loss Function and Feature Selection for Alzheimer's Disease Diagnosis
Source quote
L243: MP and MPC were better than the same methods with single-modality data such as MRI and PET. Also, the classification performance by MPC was generally better than MP. For example, in the discrimination between AD and NC, the proposed method with MPC achieved the classification accuracy of 95.9%, sensitivity of 95.7%, specificity of 98.6%, and AUC of 98.8%, while the best performance among other competing methods with single-modality data was 93.8% (ACC),
2014Proposed method (MPC: MRI+PET+CSF) proposedACC (accuracy)82.0%Binary Classification · split: val · data=baseline · modalities=MRI+PET+CSF · validation=10-fold cross-validation repeated 10 timesMatrix-Similarity Based Loss Function and Feature Selection for Alzheimer's Disease Diagnosis
Source quote
L510: 82.0
2014Proposed method (MPC: MRI+PET+CSF) proposedAUC87.0%Binary Classification · split: val · data=baseline · modalities=MRI+PET+CSF · validation=10-fold cross-validation repeated 10 timesMatrix-Similarity Based Loss Function and Feature Selection for Alzheimer's Disease Diagnosis
Source quote
L513: 87.0
2014CB-SVM (proposed coupled boosting) proposedACC (classification accuracy)94.7%Binary Classification · split: val · comparison=AD vs NC · modalities=MRI+PET · validation=10-fold cross-validation repeated 100 timesJoint Coupled-Feature Representation and Coupled Boosting for AD Diagnosis
Source quote
L8: Specifically, we formulate a new weight updating function, which considers both incorrectly and inconsistently classified samples. In our experiments on the ADNI dataset, the proposed method presented the best performance with accuracies of 94.7% and 80.1% for AD vs. Normal Control (NC) and MCI vs. NC classifications, respectively, outperforming the competing methods and the state-of-the-art methods.
2014CB-SRC (proposed coupled boosting) proposedACC (classification accuracy)80.1%Binary Classification · split: val · comparison=MCI vs NC · modalities=MRI+PET · validation=10-fold cross-validation repeated 100 timesJoint Coupled-Feature Representation and Coupled Boosting for AD Diagnosis
Source quote
L8: Specifically, we formulate a new weight updating function, which considers both incorrectly and inconsistently classified samples. In our experiments on the ADNI dataset, the proposed method presented the best performance with accuracies of 94.7% and 80.1% for AD vs. Normal Control (NC) and MCI vs. NC classifications, respectively, outperforming the competing methods and the state-of-the-art methods.
2014CB-SVM (proposed coupled boosting) proposedAUC0.975Binary Classification · split: val · comparison=AD vs NC · modalities=MRI+PET · validation=10-fold cross-validation repeated 100 timesJoint Coupled-Feature Representation and Coupled Boosting for AD Diagnosis
Source quote
L386: MCI vs. NC (by CB-SRC) classifications. Regarding AUCs, we repeated the 10-fold CV 100 times to reduce the possible bias caused by different data partition, and then obtained the mean AUC value. Our best AUCs were 0.975 (AD vs.
2014CB-SRC (proposed coupled boosting) proposedAUC0.833Binary Classification · split: val · comparison=MCI vs NC · modalities=MRI+PET · validation=10-fold cross-validation repeated 100 timesJoint Coupled-Feature Representation and Coupled Boosting for AD Diagnosis
Source quote
L387: NC) and 0.833 (MCI vs. NC), better than results in [21].
2011SCLDA-selected 47 features (26 PET and 21 MRI) with linear SVM proposedclassification accuracy94.3%Alzheimer Disease Classification · split: val · cohort=49 AD; 67 NC · classifier=linear SVM · modalities=PET+MRI · validation=10-fold cross-validationIdentifying Alzheimer's Disease-Related Brain Regions from Multi-Modality Neuroimaging Data using Sparse Composite Linear Discrimination Analysis
Source quote
L232: As one of our primary goals is to distinguish AD from NC, the identified disease-related brain regions through SCLDA are further utilized for establishing a classification model. Specifically, for each subject, the rCBF values of the 26 disease-related brain regions identified from PET and the structural volumes of the 21 disease-related brain regions identified from MRI are used, as a joint spatial pattern of both brain physiology and structure. As a result, each subject is associated with a vector with 47 features/variables. Linear SVM (Support Vector Machine) is employed as the classifier. The classification accuracy based on 10-fold cross-validation is 94.3%. For comparison purposes, MSLDA is also applied, which identifies 45 and 38 disease-related brain regions for PET and MRI, respectively. Linear SVM applied to the 45+38 features gives a classification accuracy of only 85.8%. Note that MSLDA identifies a much larger number of disease-related brain regions than SCLDA, but some of the identified regions by MSLDA may indeed be disease-irrelevant, so including them deteriorates the classification.
2011MSLDA-selected 83 features (45 PET and 38 MRI) with linear SVM baselineclassification accuracy85.8%Alzheimer Disease Classification · split: val · cohort=49 AD; 67 NC · classifier=linear SVM · modalities=PET+MRI · validation=10-fold cross-validationIdentifying Alzheimer's Disease-Related Brain Regions from Multi-Modality Neuroimaging Data using Sparse Composite Linear Discrimination Analysis
Source quote
L232: As one of our primary goals is to distinguish AD from NC, the identified disease-related brain regions through SCLDA are further utilized for establishing a classification model. Specifically, for each subject, the rCBF values of the 26 disease-related brain regions identified from PET and the structural volumes of the 21 disease-related brain regions identified from MRI are used, as a joint spatial pattern of both brain physiology and structure. As a result, each subject is associated with a vector with 47 features/variables. Linear SVM (Support Vector Machine) is employed as the classifier. The classification accuracy based on 10-fold cross-validation is 94.3%. For comparison purposes, MSLDA is also applied, which identifies 45 and 38 disease-related brain regions for PET and MRI, respectively. Linear SVM applied to the 45+38 features gives a classification accuracy of only 85.8%. Note that MSLDA identifies a much larger number of disease-related brain regions than SCLDA, but some of the identified regions by MSLDA may indeed be disease-irrelevant, so including them deteriorates the classification.
2010SVM with spatial priors (3D spatial-proximity experiment) proposedclassification accuracy85%Brain Image Classification · split: val · leave-one-out · C=1 · cohort=30 AD, 30 controls · method=spatial-proximity SVM · classes=AD vs CNSpatial and anatomical regularization of SVM for brain image analysis
Source quote
L229: The classifiers were able to distinguish AD from CN with similar accuracies (83% with no spatial priors and 85% with spatial priors).
2010Linear SVM without spatial priors baselineclassification accuracy83%Brain Image Classification · split: val · leave-one-out · C=1 · input=3D gray-matter probability maps · cohort=30 AD, 30 controls · classes=AD vs CNSpatial and anatomical regularization of SVM for brain image analysis
Source quote
L229: The classifiers were able to distinguish AD from CN with similar accuracies (83% with no spatial priors and 85% with spatial priors).