ADNI · Classification
202 papers · 607 extracted observations · classification · Markdown · CSV · JSON API
Tasks on ADNIAll tasks (202)Classification (44)Alzheimer Disease Classification (13)Binary Classification (13)Disease Classification (13)Image Classification (5)Medical Image Classification (5)Image Generation (4)Image Reconstruction (4)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Proposed/measured results matching task=Classification.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | MedOrch (o1-mini, best@5) SOTA frontier (+1 variant) | 93.26% | 2025-06-01 | Three-class AD vs. MCI vs. NC diagnosis; best@5 counts a case correct if any of five … | MedOrch: Medical Diagnosis with Tool-Augmented Reasoning Agents for Flexible ExtensibilitySource quoteDiagnostic Performance. On the three-class AD vs. MCI vs. NC classification task, \texttt{MedOrch}\xspace with o1-mini using the best@5 strategy achieves the highest accuracy of 93.26%, outperforming all baseline methods, including the previous state-of-the-art ConvNext+GPT approach (89.05%). This represents a 4.21% absolute improvement in accuracy. Similar patterns are observed in the four-class classification tasks (AD vs. EMCI vs. LMCI vs. NC), where \texttt{MedOrch}\xspace consistently outperforms baselines across all metrics. The significant improvement highlights the value of \texttt{MedOrch}\xspace' dynamic tool-calling approach, which can adapt its information-gathering strategy to each specific case. |
| 2 | Reinforced Domain Selection (+1 variant) | 90.5% | 2025-10-01 | CDA comparison with four intermediate domains; ADNI classification across five diseas… | Reinforced Domain Selection for Continuous Domain AdaptationSource quoteOurs │ 93.4 │ 90.5 |
| 3 | MST-former (3 scales) SOTA frontier (+1 variant) | 90.3% | 2024-02-01 | resolution=256x256 · Next-status prediction among NC, MCI, and AD from clips of 3 MRI scans (256×256×256). | Multi-Scale Spatio-Temporal Transformer-Based Imbalanced Longitudinal Learning for Glaucoma Forecasting From Irregular Time Series ImagesSource quoteOurs │ 0.966 │ 90.3 │ 87.0 │ 94.2 |
| 4 | Artemis | 84.3% | 2026-06-01 | classes=NC vs. MCI · ADNI benchmark task: NC vs. MCI; reported score. | Artemis: Anatomy-Resolved inTervention for Eliminating Multimodal NeuroImage confounderSSource quoteOn ADNI, Artemis achieves 84.3% accuracy, a +5.0% absolute improvement over the best baseline BrainNetCNN (79.3%), and a macro-F1 of 73.5% compared with BrainNetCNN's 52.4%, a +21.1 percentage-point gain that reflects far more balanced recall across the NC and MCI classes. |
| 5 | M3D + LGA | 76.7% | 2025-09-01 | runs=5 · backbone=M3D · component=LGA · training-samples=1,504 · Three-way classification; M3D backbone with LGA fine-tuning; 1,504 training samples; … | Data-Efficient Fine-Tuning of Vision-Language Models for Diagnosis of Alzheimer's DiseaseSource quote\quad + LGA~\cite{hu2024lga} │ 76.7 │ 80.0 │ + 85.2M │ 1,504 |
| 6 | TabSeq SOTA frontier (+1 variant) | 75.13% | 2024-01-01 | partition=70:15:15 · feature-ordering=with; k-means, 5 clusters, ascending · target-attribute=ABETA12 · Acc.* (with feature ordering); k-means with 5 clusters, ascending order; dataset part… | TabSeq: A Framework for Deep Learning on Tabular Data via Sequential OrderingSource quoteTabSeq (ours) │ 64.44% │ 0.55 │ 75.13% │ 0.71 |
| 7 | ConnectomeDiffuser | 71.25% | 2025-01-01 | Classification performance for brain network construction methods; the cited table do… | ConnectomeDiffuser: Generative AI Enables Brain Network Construction From Diffusion Tensor ImagingSource quote\multirow{6}{*}{ADNI} │ ConnectomeDiffuser │ 71.25 │ 71.84 │ 71.25 │ 71.09 |
| 8 | QDA SOTA frontier (+1 variant) | 68% | 2012-01-01 | features=shape, PET, APOE carrier status, CSF Aβ-42 and ptau181 · weighting=η=0.8 · classifier=QDA · ADNI baseline data; analysis adds log-transformed CSF Aβ-42 and ptau181 to the preced… | Genetic, Structural and Functional Imaging Biomarkers for Early Detection of Conversion from MCI to ADSource quote29 NL, 36 AD and 59 MCI. With CSF-biomarkers, a slight increase in accuracy was observed for QDA: accuracy=68% and AUC= 0.72 (η = 0.8). |
Other primary task on ADNI: Classification · AUC ↑ (5 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | MST-former (3 scales) SOTA frontier (+1 variant) | 0.966 | 2024-02-01 | resolution=256x256 · Next-status prediction among NC, MCI, and AD from clips of 3 MRI scans (256×256×256). | Multi-Scale Spatio-Temporal Transformer-Based Imbalanced Longitudinal Learning for Glaucoma Forecasting From Irregular Time Series ImagesSource quoteOurs │ 0.966 │ 90.3 │ 87.0 │ 94.2 |
| 2 | BrainInterNet | 0.85 | 2026-03-01 | Three-way CN/MCI/AD classification; all models fine-tuned using subject-level data sp… | Interpretable Cross-Network Attention for Resting-State fMRI Representation LearningSource quoteOurs - Cross │ Net │ \ding{55} │ 60.29 │ 58.22 │ 0.615 │ BrainInterNet\xspace │ Net │ \ding{51} │ 77.53 │ 77.55 │ 0.850 |
| 3 | Proposed atlas-estimated volumes of all nuclei, leave-one-out linear discriminant analysis (LDA) SOTA frontier (+1 variant) | 0.83 | 2018-01-01 | cohort=213 Alzheimer's disease; 161 controls · features=volumes of all nuclei · classifier=leave-one-out LDA · 213 Alzheimer's disease subjects and 161 age-matched controls; volumes corrected for … | A probabilistic atlas of the human thalamic nuclei combining ex vivo MRI and histologySource quoteThe receiver operating characteristic (ROC) curves are shown in Figure~\ref{fig:ROC}. The area under the curve (AUC), which is a threshold-independent measure of performance for a classifier, was 0.632 for the thalamic volumes given Freesurfer's main stream. When using the whole thalamic volumes given by the proposed atlas, the AUC was slightly higher (AUC = 0.645), though the difference was not statistically significant (p = 0.4) according to a paired DeLong test \citep{delong1988comparing}. However, when using all nuclei simultaneously, the AUC increased considerably to 0.830 (p \sim 10 (-10) against the whole thalamic volumes, given by \texttt{recon-all} or our proposed atlas). |
| 4 | GE-IFRVFL-CIL-1 | 0.757 | 2024-01-01 | comparisons=CN_vs_AD, CN_vs_MCI, MCI_vs_AD · comparison_count=3 · Average across the three ADNI binary comparisons: CN_vs_AD, CN_vs_MCI, and MCI_vs_AD. | Graph Embedded Intuitionistic Fuzzy Random Vector Functional Link Neural Network for Class Imbalance LearningSource quoteAverage AUC │ 0.7212 │ 0.6618 │ 0.6873 │ 0.7519 │ 0.7273 │ 0.7555 │ \bm{0.757} │ 0.7486 |
| 5 | QDA SOTA frontier | 0.72 | 2012-01-01 | features=shape, PET, APOE carrier status, CSF Aβ-42 and ptau181 · weighting=η=0.8 · classifier=QDA · ADNI baseline data; analysis adds log-transformed CSF Aβ-42 and ptau181 to the preced… | Genetic, Structural and Functional Imaging Biomarkers for Early Detection of Conversion from MCI to ADSource quote29 NL, 36 AD and 59 MCI. With CSF-biomarkers, a slight increase in accuracy was observed for QDA: accuracy=68% and AUC= 0.72 (η = 0.8). |
Other primary task on ADNI: Classification · AUROC ↑ · test (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | MM-KG (condition D; Qwen3.5-9B) SOTA frontier | 0.86 | 2026-10-01 | params=9B · Paired contraindication benchmark, 70-item test set; condition D supplies both patien… | Aligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMsSource quote0.786 (.86) |
| 2 | MORPHADE (unsupervised) SOTA frontier | 0.8 | 2024-07-01 | method=unsupervised · training=760 healthy controls · Trained on 760 healthy controls; evaluated on the test set of 215 HC and 200 AD sampl… | Unsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable AutoencodersSource quoteIn this section, we assess the capability of MORPHADE in detecting AD at the patient level. Table \ref{tab::benchmark_anomaly_detection} shows the Area Under the Receiver Operating Characteristic curve (AUROC) scores obtained when comparing our method to various baselines for identifying subjects with AD compared to healthy control (HC) subjects. Our model achieves an AUROC of 0.80, surpassing even the 3D supervised baselines ResNet \cite{supervised_resnet} and DenseNet \cite{supervised_densenet}, with AUROCs of 0.77 and 0.74, respectively. |
Other primary task on ADNI: Classification · Accuracy ↑ (%) · test (4 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | tLSSVM-MTL SOTA frontier | 98.17% | 2023-08-01 | tasks=4 × 4 × 3 · kernel=RBF · training-sample-ratio=0.3 · RBF kernel; ADNI classification with training-sample ratio 0.3; 4×4×3 classification … | Low-Rank Multitask Learning based on Tensorized SVMs and LSSVMsSource quotetLSSVM-MTL │ 98.17% │ 97.85% │ 98.48% │ 98.16%\% │ 5.31 |
| 2 | KAN classifier | 81.85% | 2025-01-01 | Middle sagittal sMRI slice; diagnostic categories include cognitively normal, MCI, an… | Interpreting Kolmogorov-Arnold Networks in Neuroimaging: A Path-Based Attribution FrameworkSource quoteWe train a KAN on the datasets and achieve test accuracies of 93.24%, 81.85% and 91.25% respectively, on the OASIS-1, ADNI and Mendeley test sets. We also train the KAN on MNIST classification as a Proofof-Concept (PoC) and achieve a test accuracy of 99.4%. Using the proposed path-based attribution, we obtain an Insertion AUC of 0.865 ± 0.049, Deletion AUC of 0.282 ± 0.020, and Sufficiency of 0.068 ± 0.064 on the OASIS dataset as indicated in Table 1. On ADNI, the method achieves an Insertion AUC of 0.758 |
| 3 | IMMFM-forecast ventricular-area classifier | 80.8% | 2025-10-01 | input=IMMFM-forecast ventricular area · classification=AD-CN · forecast-horizon=36 months · Binary classification on the main test set using normalized ventricular area forecast… | Longitudinal Flow Matching for Trajectory ModelingSource quoteFinally, we examine the specific progression of the disease. For the ADNI dataset, we focus on the ventricle region, as ventricular enlargement is a well-studied biomarker of AD progression and its underlying neurodegenerative process \citep{nestor2008ventricular}. IMMFM captures distinct ventricular growth trajectories for AD versus CN groups without explicit class conditioning (Fig.~\ref{fig:ad_dist}). Using only observed data at the second visit (\sim18 months), AD–CN classification reaches \bm{71.7%}. When using trajectories forecasted by our model to \sim36 months, AD-CN classification accuracy increases to \bm{80.8%}, a \bm{9.1%} gain. In practical terms, this corresponds to correctly classifying about nine additional subjects per 100, 18 months earlier than would be possible using only the observed data (see Appendix~\ref{app:classification_details} for additional details). |
| 4 | CoCoLIT | 62.3% | 2026-01-01 | method-setting=LAS m=64 · classification-threshold=selected on internal validation set · CoCoLIT with LAS m=64. Aβ positivity is cortical mean SUVR >1.11; the classification … | CoCoLIT: ControlNet-Conditioned Latent Image Translation for MRI to Amyloid PET SynthesisSource quotem=64 │ 0.896 ± 0.050 │ 24.135 ± 2.820 │ 0.0050 ± 0.0047 │ 0.328~(p<0.001) │ 0.522~(p<0.001) │ 62.3% |
Other primary task on ADNI: Classification · Accuracy ↑ (%) · val (3 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Heter-LBI (proposed method; table label “Ours”) SOTA frontier (+2 variants) | 91.48% | 2025-01-01 | comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=3.0T · 10-fold cross-validation on baseline T1-weighted MRI; ADNI data. 30T denotes 3.0 Tesl… | A Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging AnalysisSource quote91.48% |
| 2 | WSEK (weighted subspace exponential kernel) SOTA frontier | 79% | 2023-02-01 | modality=fMRI · classifier=KSTM · rank-selection=best average over Tucker ranks 1–10 · KSTM; mean accuracy from cross-validation, reported as the best average over Tucker r… | A weighted subspace exponential kernel for support tensor machinesSource quote(79% for ADNI and 64% for ADHD) compared to other state of the art tensor kernels. We note that the accuracy of the subspace kernel improves for higher ranks in the ADHD dataset and is then similar to that of WSEK but this choice of rank is very high for a low-rank truncation method. On the other hand, our proposed kernel gives good classification accuracy already at rank 2. The Gaussian kernel was computed for different Tucker approximations of the full tensor. Using the full tensor in the computation of the kernel did not improve the accuracy. As in~\cite{KourJMLR}, the DuSK kernel was computed using a CP approximation of the full tensor (CP-DuSK), because computing the Tucker decomposition and then converting to CP yielded high CP ranks and DuSK was too slow. |
| 3 | ETLN^E (ECN-only) SOTA frontier (+1 variant) | 73.47% | 2023-01-01 | 10-fold cross-validation; SVM on RFE-selected 1,000 edge-weight features; ETLN^E uses… | A Structure-Guided Effective and Temporal-Lag Connectivity Network for Revealing Brain Disorder MechanismsSource quoteETLN (E) │ 74.31 │ 70.59 │ 77.59 │ 72.00 │ 78.02 │ 82.35 │ 72.50 │ 80.77 │ 73.47 │ 82.76 │ 60.00 │ 78.69 |
TaskClassification (109)Alzheimer Disease Classification (40)Binary Classification (40)Disease Classification (37)Medical Image Classification (13)Mci Conversion Prediction (12)Image Reconstruction (12)
Regimefine-tuned (26)unsupervised (12)semi-supervised (10)5-fold-cross-validation (7)5-fold-cv (6)pipeline-drift-comparison (6)
Showing 18 of 18 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | Heter-LBI (proposed method; table label “Ours”) proposed | classification accuracy | 88.96% | Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=1.5T | A Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging AnalysisSource quoteL490: 88.96% |
| 2025 | Heter-LBI (proposed method; table label “Ours”) proposed | classification accuracy | 91.48% | Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=3.0T | A Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging AnalysisSource quoteL491: 91.48% |
| 2025 | Heter-LBI (proposed method; table label “Ours”) proposed | classification accuracy | 74.00% | Classification · split: val · comparison=MCI-vs-NC · validation=10-fold cross-validation · field-strength=1.5T | A Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging AnalysisSource quoteL492: 74.00% is enforced with spatial smoothness and non-negativity constraint to learn the lesion features and a dense parameter to additionally learn the procedural bias. |
| 2025 | Proposed spatial-temporal transformer (Ours; temporal and spatial blocks) proposed | ACC | 89.1 | Classification · split: val · 5-fold-cv · evaluation=subject-level | Classification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal TransformerSource quoteL148: 89.1 |
| 2025 | Proposed spatial-temporal transformer (Ours; temporal and spatial blocks) proposed | F1 | 90.3 | Classification · split: val · 5-fold-cv · evaluation=subject-level | Classification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal TransformerSource quoteL152: 90.3 os-FC: original static FC; S/T-only: Using only the spatial/ temporal block |
| 2025 | Proposed framework with contrastive learning proposed | Accuracy improvement | 9.7% | Classification · split: val · 5-fold-cv · component=contrastive-learning · comparison=without-contrastive-learning · evaluation=subject-level | Classification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal TransformerSource quoteL114: To verify our proposed model, we compare it with other widely used methods in the literature listed in Table 1. Our results outperform most other studies. Furthermore, the proposed method incorporating contrastive learning strategy performs significantly better than the method without contrastive learning strategy on this data, showing an improvement of 9.7% in accuracy and 7.3% in F1 score when contrastive learning is applied. |
| 2025 | Proposed framework with contrastive learning proposed | F1 improvement | 7.3% | Classification · split: val · 5-fold-cv · component=contrastive-learning · comparison=without-contrastive-learning · evaluation=subject-level | Classification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal TransformerSource quoteL114: To verify our proposed model, we compare it with other widely used methods in the literature listed in Table 1. Our results outperform most other studies. Furthermore, the proposed method incorporating contrastive learning strategy performs significantly better than the method without contrastive learning strategy on this data, showing an improvement of 9.7% in accuracy and 7.3% in F1 score when contrastive learning is applied. |
| 2025 | S-only (spatial block only) ablation | ACC | 76.6 | Classification · split: val · 5-fold-cv · ablation=spatial-block-only · evaluation=subject-level | Classification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal TransformerSource quoteL136: 76.6 |
| 2025 | S-only (spatial block only) ablation | F1 | 73.1 | Classification · split: val · 5-fold-cv · ablation=spatial-block-only · evaluation=subject-level | Classification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal TransformerSource quoteL140: 73.1 |
| 2025 | GSplit LBI baseline | classification accuracy | 88.31% | Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=1.5T | A Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging AnalysisSource quoteL486: 88.31% |
| 2025 | GSplit LBI baseline | classification accuracy | 88.64% | Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=3.0T | A Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging AnalysisSource quoteL487: 88.64% |
| 2025 | SVM baseline | classification accuracy | 73.50% | Classification · split: val · comparison=MCI-vs-NC · validation=10-fold cross-validation · field-strength=1.5T | A Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging AnalysisSource quoteL468: 73.50% |
| 2023 | WSEK (weighted subspace exponential kernel) proposed | average classification accuracy | 79% | Classification · split: val · modality=fMRI · classifier=KSTM · rank-selection=best average over Tucker ranks 1–10 | A weighted subspace exponential kernel for support tensor machinesSource quoteL381: (79% for ADNI and 64% for ADHD) compared to other state of the art tensor kernels. We note that the accuracy of the subspace kernel improves for higher ranks in the ADHD dataset and is then similar to that of WSEK but this choice of rank is very high for a low-rank truncation method. On the other hand, our proposed kernel gives good classification accuracy already at rank 2. The Gaussian kernel was computed for different Tucker approximations of the full tensor. Using the full tensor in the computation of the kernel did not improve the accuracy. As in~\cite{KourJMLR}, the DuSK kernel was computed using a CP approximation of the full tensor (CP-DuSK), because computing the Tucker decomposition and then converting to CP yielded high CP ranks and DuSK was too slow. |
| 2022 | ETLN^E (ECN-only) | ACC (prediction accuracy) | 73.47 | Classification · split: val | A Structure-Guided Effective and Temporal-Lag Connectivity Network for Revealing Brain Disorder MechanismsSource quoteL175: ETLN (E) │ 74.31 │ 70.59 │ 77.59 │ 72.00 │ 78.02 │ 82.35 │ 72.50 │ 80.77 │ 73.47 │ 82.76 │ 60.00 │ 78.69 |
| 2022 | LR | ACC (prediction accuracy) | 67.35 | Classification · split: val | A Structure-Guided Effective and Temporal-Lag Connectivity Network for Revealing Brain Disorder MechanismsSource quoteL169: LR │ 69.72 │ 66.67 │ 72.41 │ 67.33 │ 74.73 │ 80.39 │ 67.50 │ 78.10 │ 67.35 │ 75.86 │ 55.00 │ 73.33 |
| 2020 | TT-MMK proposed | Average classification accuracy | 73% | Classification · split: val · 5-fold-cross-validation · data=resting-state fMRI · classes=AD+MCI vs normal controls · subjects=33 · repetitions=50 | Efficient Structure-preserving Support Tensor Train MachineSource quoteL515: TT-MMK │ 73 │ 64 │ 99 │ 99 |
| 2020 | Improved MMK baseline | Average classification accuracy | 71% | Classification · split: val · 5-fold-cross-validation · data=resting-state fMRI · classes=AD+MCI vs normal controls · subjects=33 · repetitions=50 | Efficient Structure-preserving Support Tensor Train MachineSource quoteL514: Improved MMK │ 71 │ 61 │ 94 │ 98 |
| 2019 | Linear SVM using morphological age and disease score proposed | Mean classification accuracy | 0.59 | Classification · split: val · classes=MCI stable vs MCI converters · classifier=linear SVM · validation=10-fold cross-validation | A model of brain morphological changes related to aging and Alzheimer's disease from cross-sectional assessmentsSource quoteL291: We also perform a simple linear classification task between the MCIs and MCIc groups using this two cross-sectional markers. A SVM linear classifier is fitted to the full data-set to perform the binary classification\footnote{The classification task was performed using the SVC module of the scikit-learn python library~\citep{scikit-learn}}. The error penalty weights are adjusted between the two classes to balance the trade-off between false positive and false negative rate. The mean classification accuracy using a 10-folds cross-validation scheme is equal to 0.59. The linear decision function is equivalent to the projection on the SVF v_A - 0.003 v_D, so the differences between MCIs and MCIc subjects is, in our model, only associated with the aging trajectory while the disease specific changes do not seem to have an impact before the conversion. For comparison, for the same experiment between CN and AD, the linear classifier corresponds to the projection on v_A + 0.49 v_D so approximately (v-bn + v-ad) / 2, i.e. the mean evolution of the whole population. Of course, in both cases we do not reach the performance of state-of-the-art dedicated algorithm but it allows us to see how both markers are associated with the diagnosis. Moreover this discriminant approach could be extended by using information in a subset of targeted areas. |