ADNI · Classification

202 papers · 607 extracted observations · classification · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Classification.

46.963.580.196.7201220192026QDA: 66.14 (2012)QDA: 68.0 (2012)TabSeq: 64.44 (2024)TabSeq: 75.13 (2024)GLIM-Net: 77.9 (2024)MST-former (3 scales): 90.3 (2024)ConnectomeDiffuser: 71.25 (2025)MedOrch: 50.35 (2025)MedOrch (o1-mini, best@5): 93.26 (2025)M3D + LGA: 76.7 (2025)RCL: 89.3 (2025)Reinforced Domain Selection: 90.5 (2025)Artemis: 84.3 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 18 of 18 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025Heter-LBI (proposed method; table label “Ours”) proposedclassification accuracy88.96%Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=1.5TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L490: 88.96%
2025Heter-LBI (proposed method; table label “Ours”) proposedclassification accuracy91.48%Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=3.0TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L491: 91.48%
2025Heter-LBI (proposed method; table label “Ours”) proposedclassification accuracy74.00%Classification · split: val · comparison=MCI-vs-NC · validation=10-fold cross-validation · field-strength=1.5TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L492: 74.00% is enforced with spatial smoothness and non-negativity constraint to learn the lesion features and a dense parameter to additionally learn the procedural bias.
2025Proposed spatial-temporal transformer (Ours; temporal and spatial blocks) proposedACC89.1Classification · split: val · 5-fold-cv · evaluation=subject-levelClassification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal Transformer
Source quote
L148: 89.1
2025Proposed spatial-temporal transformer (Ours; temporal and spatial blocks) proposedF190.3Classification · split: val · 5-fold-cv · evaluation=subject-levelClassification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal Transformer
Source quote
L152: 90.3 os-FC: original static FC; S/T-only: Using only the spatial/ temporal block
2025Proposed framework with contrastive learning proposedAccuracy improvement9.7%Classification · split: val · 5-fold-cv · component=contrastive-learning · comparison=without-contrastive-learning · evaluation=subject-levelClassification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal Transformer
Source quote
L114: To verify our proposed model, we compare it with other widely used methods in the literature listed in Table 1. Our results outperform most other studies. Furthermore, the proposed method incorporating contrastive learning strategy performs significantly better than the method without contrastive learning strategy on this data, showing an improvement of 9.7% in accuracy and 7.3% in F1 score when contrastive learning is applied.
2025Proposed framework with contrastive learning proposedF1 improvement7.3%Classification · split: val · 5-fold-cv · component=contrastive-learning · comparison=without-contrastive-learning · evaluation=subject-levelClassification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal Transformer
Source quote
L114: To verify our proposed model, we compare it with other widely used methods in the literature listed in Table 1. Our results outperform most other studies. Furthermore, the proposed method incorporating contrastive learning strategy performs significantly better than the method without contrastive learning strategy on this data, showing an improvement of 9.7% in accuracy and 7.3% in F1 score when contrastive learning is applied.
2025S-only (spatial block only) ablationACC76.6Classification · split: val · 5-fold-cv · ablation=spatial-block-only · evaluation=subject-levelClassification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal Transformer
Source quote
L136: 76.6
2025S-only (spatial block only) ablationF173.1Classification · split: val · 5-fold-cv · ablation=spatial-block-only · evaluation=subject-levelClassification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal Transformer
Source quote
L140: 73.1
2025GSplit LBI baselineclassification accuracy88.31%Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=1.5TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L486: 88.31%
2025GSplit LBI baselineclassification accuracy88.64%Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=3.0TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L487: 88.64%
2025SVM baselineclassification accuracy73.50%Classification · split: val · comparison=MCI-vs-NC · validation=10-fold cross-validation · field-strength=1.5TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L468: 73.50%
2023WSEK (weighted subspace exponential kernel) proposedaverage classification accuracy79%Classification · split: val · modality=fMRI · classifier=KSTM · rank-selection=best average over Tucker ranks 1–10A weighted subspace exponential kernel for support tensor machines
Source quote
L381: (79% for ADNI and 64% for ADHD) compared to other state of the art tensor kernels. We note that the accuracy of the subspace kernel improves for higher ranks in the ADHD dataset and is then similar to that of WSEK but this choice of rank is very high for a low-rank truncation method. On the other hand, our proposed kernel gives good classification accuracy already at rank 2. The Gaussian kernel was computed for different Tucker approximations of the full tensor. Using the full tensor in the computation of the kernel did not improve the accuracy. As in~\cite{KourJMLR}, the DuSK kernel was computed using a CP approximation of the full tensor (CP-DuSK), because computing the Tucker decomposition and then converting to CP yielded high CP ranks and DuSK was too slow.
2022ETLN^E (ECN-only)ACC (prediction accuracy)73.47Classification · split: valA Structure-Guided Effective and Temporal-Lag Connectivity Network for Revealing Brain Disorder Mechanisms
Source quote
L175: ETLN (E) │ 74.31 │ 70.59 │ 77.59 │ 72.00 │ 78.02 │ 82.35 │ 72.50 │ 80.77 │ 73.47 │ 82.76 │ 60.00 │ 78.69
2022LRACC (prediction accuracy)67.35Classification · split: valA Structure-Guided Effective and Temporal-Lag Connectivity Network for Revealing Brain Disorder Mechanisms
Source quote
L169: LR │ 69.72 │ 66.67 │ 72.41 │ 67.33 │ 74.73 │ 80.39 │ 67.50 │ 78.10 │ 67.35 │ 75.86 │ 55.00 │ 73.33
2020TT-MMK proposedAverage classification accuracy73%Classification · split: val · 5-fold-cross-validation · data=resting-state fMRI · classes=AD+MCI vs normal controls · subjects=33 · repetitions=50Efficient Structure-preserving Support Tensor Train Machine
Source quote
L515: TT-MMK │ 73 │ 64 │ 99 │ 99
2020Improved MMK baselineAverage classification accuracy71%Classification · split: val · 5-fold-cross-validation · data=resting-state fMRI · classes=AD+MCI vs normal controls · subjects=33 · repetitions=50Efficient Structure-preserving Support Tensor Train Machine
Source quote
L514: Improved MMK │ 71 │ 61 │ 94 │ 98
2019Linear SVM using morphological age and disease score proposedMean classification accuracy0.59Classification · split: val · classes=MCI stable vs MCI converters · classifier=linear SVM · validation=10-fold cross-validationA model of brain morphological changes related to aging and Alzheimer's disease from cross-sectional assessments
Source quote
L291: We also perform a simple linear classification task between the MCIs and MCIc groups using this two cross-sectional markers. A SVM linear classifier is fitted to the full data-set to perform the binary classification\footnote{The classification task was performed using the SVC module of the scikit-learn python library~\citep{scikit-learn}}. The error penalty weights are adjusted between the two classes to balance the trade-off between false positive and false negative rate. The mean classification accuracy using a 10-folds cross-validation scheme is equal to 0.59. The linear decision function is equivalent to the projection on the SVF v_A - 0.003 v_D, so the differences between MCIs and MCIc subjects is, in our model, only associated with the aging trajectory while the disease specific changes do not seem to have an impact before the conversion. For comparison, for the same experiment between CN and AD, the linear classifier corresponds to the projection on v_A + 0.49 v_D so approximately (v-bn + v-ad) / 2, i.e. the mean evolution of the whole population. Of course, in both cases we do not reach the performance of state-of-the-art dedicated algorithm but it allows us to see how both markers are associated with the diagnosis. Moreover this discriminant approach could be extended by using information in a subset of targeted areas.