ADNI · Classification

202 papers · 607 extracted observations · classification · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Classification.

46.963.580.196.7201220192026QDA: 66.14 (2012)QDA: 68.0 (2012)TabSeq: 64.44 (2024)TabSeq: 75.13 (2024)GLIM-Net: 77.9 (2024)MST-former (3 scales): 90.3 (2024)ConnectomeDiffuser: 71.25 (2025)MedOrch: 50.35 (2025)MedOrch (o1-mini, best@5): 93.26 (2025)M3D + LGA: 76.7 (2025)RCL: 89.3 (2025)Reinforced Domain Selection: 90.5 (2025)Artemis: 84.3 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 28 of 28 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026MMAP (full model, I + T) proposedBACC0.786Classification · split: test · fine-tunedMMAP: Multimodal Missing-Aware Pretraining for Longitudinal Alzheimer's Prediction
Source quote
L382: 0.786 0.850 0.690 0.733 0.760 0.820
2026DeCI proposedAccuracy+11.25 ppClassification · split: testMoving Beyond Functional Connectivity: Time-Series Modeling for fMRI-Based Brain Disorder Classification
Source quote
L257: Paired two-sided t-tests on the 5-fold results (Table~\ref{tab:significance}) show that DeCI significantly outperforms Leddam. On ADNI, DeCI improves Accuracy by +11.25\,pp \([8.24, 14.28]\), d_z=4.63, and F1-Score by +22.13\,pp \([13.92, 30.33]\), d_z=3.35 (both p<0.001). On Mātai, Accuracy and F1-Score improve by +3.34\,pp \([0.35, 6.31]\), d_z=1.39, and +4.04\,pp \([0.32, 7.76]\), d_z=1.35 (both p<0.05). On Neurocon, DeCI yields +4.11\,pp in Accuracy \([0.75, 7.47]\), d_z=1.81, and +2.66\,pp in F1-Score \([0.18, 5.14]\), d_z=1.33 (both p<0.05). On TaoWu, DeCI yields +11.50\,pp in Accuracy \([7.96, 15.04]\), d_z=4.03, and +13.83\,pp in F1-Score \([9.71, 17.93]\), d_z=4.17 (both p<0.001). With n{=}5 folds, d_z>1.2 denotes strong, stable improvements, met on Neurocon and Mātai and vastly exceeded on ADNI and TaoWu, highlighting DeCI’s effectiveness and robustness against overfitting on small sample datasets (e.g., Neurocon and TaoWu).
2026DeCI proposedF1-Score+22.13 ppClassification · split: testMoving Beyond Functional Connectivity: Time-Series Modeling for fMRI-Based Brain Disorder Classification
Source quote
L257: Paired two-sided t-tests on the 5-fold results (Table~\ref{tab:significance}) show that DeCI significantly outperforms Leddam. On ADNI, DeCI improves Accuracy by +11.25\,pp \([8.24, 14.28]\), d_z=4.63, and F1-Score by +22.13\,pp \([13.92, 30.33]\), d_z=3.35 (both p<0.001). On Mātai, Accuracy and F1-Score improve by +3.34\,pp \([0.35, 6.31]\), d_z=1.39, and +4.04\,pp \([0.32, 7.76]\), d_z=1.35 (both p<0.05). On Neurocon, DeCI yields +4.11\,pp in Accuracy \([0.75, 7.47]\), d_z=1.81, and +2.66\,pp in F1-Score \([0.18, 5.14]\), d_z=1.33 (both p<0.05). On TaoWu, DeCI yields +11.50\,pp in Accuracy \([7.96, 15.04]\), d_z=4.03, and +13.83\,pp in F1-Score \([9.71, 17.93]\), d_z=4.17 (both p<0.001). With n{=}5 folds, d_z>1.2 denotes strong, stable improvements, met on Neurocon and Mātai and vastly exceeded on ADNI and TaoWu, highlighting DeCI’s effectiveness and robustness against overfitting on small sample datasets (e.g., Neurocon and TaoWu).
2026MM-KG (condition D; Qwen3.5-9B) proposedAUROC.86Classification · split: test · params=9BAligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMs
Source quote
L585: 0.786 (.86)
2025IMMFM-forecast ventricular-area classifier proposedClassification accuracy80.8%Classification · split: test · input=IMMFM-forecast ventricular area · classification=AD-CN · forecast-horizon=36 monthsLongitudinal Flow Matching for Trajectory Modeling
Source quote
L351: Finally, we examine the specific progression of the disease. For the ADNI dataset, we focus on the ventricle region, as ventricular enlargement is a well-studied biomarker of AD progression and its underlying neurodegenerative process \citep{nestor2008ventricular}. IMMFM captures distinct ventricular growth trajectories for AD versus CN groups without explicit class conditioning (Fig.~\ref{fig:ad_dist}). Using only observed data at the second visit (\sim18 months), AD–CN classification reaches \bm{71.7%}. When using trajectories forecasted by our model to \sim36 months, AD-CN classification accuracy increases to \bm{80.8%}, a \bm{9.1%} gain. In practical terms, this corresponds to correctly classifying about nine additional subjects per 100, 18 months earlier than would be possible using only the observed data (see Appendix~\ref{app:classification_details} for additional details).
2025CoCoLIT proposedBA (balanced accuracy for Aβ-positivity classification)62.3%Classification · split: test · method-setting=LAS m=64 · classification-threshold=selected on internal validation setCoCoLIT: ControlNet-Conditioned Latent Image Translation for MRI to Amyloid PET Synthesis
Source quote
L163: m=64 │ 0.896 ± 0.050 │ 24.135 ± 2.820 │ 0.0050 ± 0.0047 │ 0.328~(p<0.001) │ 0.522~(p<0.001) │ 62.3%
2025FLIQA-AD proposed non-standard sliceclassification accuracy (ACC)97%Classification · split: test · subset=300 samples per category · sampling=patient-levelFLIQA-AD: a Fusion Model with Large Language Model for Better Diagnose and MMSE Prediction of Alzheimer's Disease
Source quote
L202: 97% and 95%.
2025SFC-GAN (translated FC) proposed non-standard sliceAccuracy16.67Classification · split: testSFC-GAN: A Generative Adversarial Network for Brain Functional and Structural Connectome Translation
Source quote
L161: Translated FC │ 16.67 │ 11.11 │ 16.67 │ 12.50 │ 52.18
2025SFC-GAN (translated SC) proposed non-standard sliceAccuracy41.67Classification · split: testSFC-GAN: A Generative Adversarial Network for Brain Functional and Structural Connectome Translation
Source quote
L162: Translated SC │ 41.67 │ 27.78 │ 41.67 │ 33.33 │ 57.78
2025KAN classifiertest accuracy81.85%Classification · split: testInterpreting Kolmogorov-Arnold Networks in Neuroimaging: A Path-Based Attribution Framework
Source quote
L181: We train a KAN on the datasets and achieve test accuracies of 93.24%, 81.85% and 91.25% respectively, on the OASIS-1, ADNI and Mendeley test sets. We also train the KAN on MNIST classification as a Proofof-Concept (PoC) and achieve a test accuracy of 99.4%. Using the proposed path-based attribution, we obtain an Insertion AUC of 0.865 ± 0.049, Deletion AUC of 0.282 ± 0.020, and Sufficiency of 0.068 ± 0.064 on the OASIS dataset as indicated in Table 1. On ADNI, the method achieves an Insertion AUC of 0.758
2025Observed-data ventricular-area classifier baselineClassification accuracy71.7%Classification · split: test · input=observed ventricular area · classification=AD-CNLongitudinal Flow Matching for Trajectory Modeling
Source quote
L351: Finally, we examine the specific progression of the disease. For the ADNI dataset, we focus on the ventricle region, as ventricular enlargement is a well-studied biomarker of AD progression and its underlying neurodegenerative process \citep{nestor2008ventricular}. IMMFM captures distinct ventricular growth trajectories for AD versus CN groups without explicit class conditioning (Fig.~\ref{fig:ad_dist}). Using only observed data at the second visit (\sim18 months), AD–CN classification reaches \bm{71.7%}. When using trajectories forecasted by our model to \sim36 months, AD-CN classification accuracy increases to \bm{80.8%}, a \bm{9.1%} gain. In practical terms, this corresponds to correctly classifying about nine additional subjects per 100, 18 months earlier than would be possible using only the observed data (see Appendix~\ref{app:classification_details} for additional details).
2024PLM proposedACC0.8693Classification · split: testConnectional-style-guided contextual representation learning for brain disease diagnosis
Source quote
L328: 0.8693
2024MORPHADE (unsupervised) proposedAUROC0.80Classification · split: test · method=unsupervised · training=760 healthy controlsUnsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable Autoencoders
Source quote
L96: In this section, we assess the capability of MORPHADE in detecting AD at the patient level. Table \ref{tab::benchmark_anomaly_detection} shows the Area Under the Receiver Operating Characteristic curve (AUROC) scores obtained when comparing our method to various baselines for identifying subjects with AD compared to healthy control (HC) subjects. Our model achieves an AUROC of 0.80, surpassing even the 3D supervised baselines ResNet \cite{supervised_resnet} and DenseNet \cite{supervised_densenet}, with AUROCs of 0.77 and 0.74, respectively.
2024DA-MIDL baselineACC0.9085Classification · split: testConnectional-style-guided contextual representation learning for brain disease diagnosis
Source quote
L333: 0.9085
2024ResNet (3D supervised baseline) baselineAUROC0.77Classification · split: test · backbone=3D ResNet · training=includes 430 AD samplesUnsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable Autoencoders
Source quote
L96: In this section, we assess the capability of MORPHADE in detecting AD at the patient level. Table \ref{tab::benchmark_anomaly_detection} shows the Area Under the Receiver Operating Characteristic curve (AUROC) scores obtained when comparing our method to various baselines for identifying subjects with AD compared to healthy control (HC) subjects. Our model achieves an AUROC of 0.80, surpassing even the 3D supervised baselines ResNet \cite{supervised_resnet} and DenseNet \cite{supervised_densenet}, with AUROCs of 0.77 and 0.74, respectively.
2024DenseNet (3D supervised baseline) baselineAUROC0.74Classification · split: test · backbone=3D DenseNet · training=includes 430 AD samplesUnsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable Autoencoders
Source quote
L96: In this section, we assess the capability of MORPHADE in detecting AD at the patient level. Table \ref{tab::benchmark_anomaly_detection} shows the Area Under the Receiver Operating Characteristic curve (AUROC) scores obtained when comparing our method to various baselines for identifying subjects with AD compared to healthy control (HC) subjects. Our model achieves an AUROC of 0.80, surpassing even the 3D supervised baselines ResNet \cite{supervised_resnet} and DenseNet \cite{supervised_densenet}, with AUROCs of 0.77 and 0.74, respectively.
2024Brainomaly baselineAUROC0.78Classification · split: test · method=anomaly detection · training=requires pathological samplesUnsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable Autoencoders
Source quote
L98: Furthermore, we obtain improved performance compared to methods proposed for unsupervised anomaly detection. These methods are only available in 2D, so were assessed slice-wise with the final anomaly scores obtained by averaging over the slices for each patient. f-AnoGAN \cite{fanogan}, Ganomaly \cite{ganomaly} obtained AUROCs of 0.70 and 0.72, respectively. We also outperform Brainomaly~\cite{brainomaly} (AUROC 0.78), a method that is not strictly unsupervised since it requires pathological samples during training for improved performance.
2024f-AnoGAN baselineAUROC0.70Classification · split: test · input=2D slices · scoring=mean over slicesUnsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable Autoencoders
Source quote
L98: Furthermore, we obtain improved performance compared to methods proposed for unsupervised anomaly detection. These methods are only available in 2D, so were assessed slice-wise with the final anomaly scores obtained by averaging over the slices for each patient. f-AnoGAN \cite{fanogan}, Ganomaly \cite{ganomaly} obtained AUROCs of 0.70 and 0.72, respectively. We also outperform Brainomaly~\cite{brainomaly} (AUROC 0.78), a method that is not strictly unsupervised since it requires pathological samples during training for improved performance.
2024Ganomaly baselineAUROC0.72Classification · split: test · input=2D slices · scoring=mean over slicesUnsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable Autoencoders
Source quote
L98: Furthermore, we obtain improved performance compared to methods proposed for unsupervised anomaly detection. These methods are only available in 2D, so were assessed slice-wise with the final anomaly scores obtained by averaging over the slices for each patient. f-AnoGAN \cite{fanogan}, Ganomaly \cite{ganomaly} obtained AUROCs of 0.70 and 0.72, respectively. We also outperform Brainomaly~\cite{brainomaly} (AUROC 0.78), a method that is not strictly unsupervised since it requires pathological samples during training for improved performance.
2023tLSSVM-MTL proposedACC98.17%Classification · split: test · tasks=4 × 4 × 3 · kernel=RBF · training-sample-ratio=0.3Low-Rank Multitask Learning based on Tensorized SVMs and LSSVMs
Source quote
L743: tLSSVM-MTL │ 98.17% │ 97.85% │ 98.48% │ 98.16%\% │ 5.31
2023MTL-LSSVM baselineACC95.42%Classification · split: test · tasks=4 × 4 × 3 · kernel=RBF · training-sample-ratio=0.3Low-Rank Multitask Learning based on Tensorized SVMs and LSSVMs
Source quote
L741: MTL-LSSVM │ 95.42% │ 94.61% │ 96.24% │ 95.42% \% │ 0.23
2021Projected group lasso (p_glasso) proposedNumber of significantly associated voxels14297 voxelsClassification · split: test · slices=nine axial slices · timepoint=month-12Multi-Task Learning with High-Dimensional Noisy Images
Source quote
L326: p\_glasso │ \bf{0.96} │ \bf{0.92} │ \bf{0.89} │ \bf{0.87} │ \bf{0.91} │ \bf{0.97} │ {\bf 0.98} │ \bf{0.90} │ \bf{0.88} │ 1370 │ 1329 │ 976 │ 1646 │ 1718 │ 702 │ 2024 │ 1915 │ 2617 │ 14297
2021Proposed hierarchical approach (P) proposedC-index.91Classification · split: testA Hierarchical Approach to Multi-Event Survival Analysis
Source quote
L361: .91(.88-.93)
2021Proposed hierarchical approach (P) proposedLocal consistency.97Classification · split: testA Hierarchical Approach to Multi-Event Survival Analysis
Source quote
L363: .97(.94-.98)
2021Group lasso without noise correction (glasso) baselineNumber of significantly associated voxels19 voxelsClassification · split: test · slices=nine axial slices · timepoint=month-12Multi-Task Learning with High-Dimensional Noisy Images
Source quote
L322: glasso │ 1.00 │ 1.00 │ 0.97 │ 0.94 │ 1.00 │ 0.99 │ 0.99 │ 0.99 │ 0.95 │ 2 │ 0 │ 0 │ 17 │ 0 │ 0 │ 0 │ 0 │ 0 │ 19
2018CNN (MRI-only) proposed non-standard sliceAccuracy92%Classification · split: test · subset=1,299 scans · modality=MRINeuroimaging modality fusion in Alzheimer’s classification using convolutional neural networks
Source quote
L80: MRI │ 92%
2018CNN (PET-only) proposed non-standard sliceAccuracy85%Classification · split: test · subset=585 scans · modality=amyloid PETNeuroimaging modality fusion in Alzheimer’s classification using convolutional neural networks
Source quote
L81: PET │ 85%
2018CNN (MRI+PET fusion) proposed non-standard sliceAccuracy94%Classification · split: test · subset=585 paired data points · modality=MRI+amyloid PET fusionNeuroimaging modality fusion in Alzheimer’s classification using convolutional neural networks
Source quote
L82: Fusion │ 94%