ADNI · Medical Image Classification

202 papers · 607 extracted observations · classification · Markdown · CSV · JSON API

Showing 7 of 7 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025SAM-Brain3D + HyDA (k=28) proposedAccuracy (ACC)88.34%Medical Image Classification · split: val · cross-validation=5-fold · hypergraph-nearest-neighbor-k=28Brain foundation models with hypergraph dynamic adapter for brain disease analysis
Source quote
L357: SAM-Brain3D + HyDA (k=28) │ 88.34 │ 71.70 │ 97.86 │ 62.19 │ 84.29
2023Proposed transfer-learning and class-decomposition model (AlexNet feature extraction; ImageNet-pretrained VGG19 classifier) proposedaccuracy98.3%Medical Image Classification · split: test · fine-tuned · cohort=134 subjects · backbone=VGG19 · pretraining=ImageNet · input-selection=20 highest-entropy 2D slices per subjectTransfer Learning and Class Decomposition for Detecting the Cognitive Decline of Alzheimer Disease
Source quote
L269: In addition, we use the entropy-based approach to select the training dataset that contains the most informative data. We use the VGG19 ImageNet-trained weights network to obtain highly accurate results. We compared our findings to those of four other cutting-edge procedures using the ADNI dataset. With an accuracy of 98.3%, our model ternary classification outperforms the other approaches, representing a
2021Our approach, 3D-ResAttNet34 (parallel) proposedAccuracy0.97Medical Image Classification · backbone=3D-ResAttNet34 · parallelism=parallelA Hybrid Parallelization Approach for Distributed and Scalable Deep Learning
Source quote
L398: Our approach │ 3D-ResAttNet34 │ Yes │ 0.84 │ 0.97
2021Our approach, 3D-ResAttNet34 (parallel) proposedAccuracy0.84Medical Image Classification · backbone=3D-ResAttNet34 · parallelism=parallelA Hybrid Parallelization Approach for Distributed and Scalable Deep Learning
Source quote
L398: Our approach │ 3D-ResAttNet34 │ Yes │ 0.84 │ 0.97
2021Proposed approach, 3D-ResAttNet34 proposed non-standard sliceSpeedup5.64Medical Image Classification · GPUs=8 · backbone=3D-ResAttNet34A Hybrid Parallelization Approach for Distributed and Scalable Deep Learning
Source quote
L376: In all cases, it is observed that our proposed approach achieves almost linear speedup, which demonstrates the scalability of our approach in that the number of GPUs is directly proportional to the training speedup performance. For instance, in AD vs. NC classification task with 3D-ResAttNet34, the training speedup for 1, 2 3, 4, 5, 6, 7, and 8 GPUs are 1, 2.38, 2.95, 3.44, 3.65, 4.13, 5.17, and 5.64 respectively. A similar trend is also observed in the sMCI vs. pMCI classification task with 3D-ResAttNet34, the training speedup for 1, 2 ,3, 4, 5, 6, 7, and 8 GPUs are 1, 2.27, 2.62, 3.09, 3.40, 3.78, 4.86, and 5.67 respectively.
2021Proposed approach, 3D-ResAttNet34 proposed non-standard sliceSpeedup5.67Medical Image Classification · GPUs=8 · backbone=3D-ResAttNet34A Hybrid Parallelization Approach for Distributed and Scalable Deep Learning
Source quote
L376: In all cases, it is observed that our proposed approach achieves almost linear speedup, which demonstrates the scalability of our approach in that the number of GPUs is directly proportional to the training speedup performance. For instance, in AD vs. NC classification task with 3D-ResAttNet34, the training speedup for 1, 2 3, 4, 5, 6, 7, and 8 GPUs are 1, 2.38, 2.95, 3.44, 3.65, 4.13, 5.17, and 5.64 respectively. A similar trend is also observed in the sMCI vs. pMCI classification task with 3D-ResAttNet34, the training speedup for 1, 2 ,3, 4, 5, 6, 7, and 8 GPUs are 1, 2.27, 2.62, 3.09, 3.40, 3.78, 4.86, and 5.67 respectively.
2021Proposed 2D-DCNN proposed non-standard sliceaccuracy99.89%Medical Image Classification · split: test · input=2D images from structural MRI · epochs=70 · classes=3 (AD/MCI/NC) · train-validation-test-split=60%-20%-20%Deep Convolutional Neural Network based Classification of Alzheimer's Disease using MRI data
Source quote
L205: 99.89% which is superior to other state-of-the-art techniques presented in literature. However, most of the studies used a combination of features from different modalities, while the proposed method is more suitable for time-saving with single modality and low-level pre-processing. The results presented in the form of confusion matrix, the loss values, and accuracy are shown in Figures 3, 4, and 5 respectively. Table II shows the comparison results of previous studies with the proposed framework. The confusion matrix and ROC curve on training, testing, and validation data demonstrate the effectiveness of this model. This paper serves as a further stimulus for utilizing different deep learning-based models for the analysis of 3D