ADNI · Classification

202 papers · 607 extracted observations · classification · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Classification.

46.963.580.196.7201220192026QDA: 66.14 (2012)QDA: 68.0 (2012)TabSeq: 64.44 (2024)TabSeq: 75.13 (2024)GLIM-Net: 77.9 (2024)MST-former (3 scales): 90.3 (2024)ConnectomeDiffuser: 71.25 (2025)MedOrch: 50.35 (2025)MedOrch (o1-mini, best@5): 93.26 (2025)M3D + LGA: 76.7 (2025)RCL: 89.3 (2025)Reinforced Domain Selection: 90.5 (2025)Artemis: 84.3 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 60 of 60 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Flux proposedaverage macro-F10.508Classification · missingness=natural sample-level; varied client-level modality availabilityMultimodal Federated Learning under Dual-Axis Modality Missingness
Source quote
L401: Table~\ref{tab:adni_results} reports results on ADNI, where natural sample-level missingness is retained while client-level modality availability is varied. \texttt{Flux}{} achieves the highest average macro-F1 of 0.508, remains competitive in the homogeneous setting, and performs best under moderate, high, and extreme inter-client heterogeneity. In the extreme setting, where each client has a unique modality composition, \texttt{Flux}{} reaches 0.395, compared with 0.389 for FedRoD. Overall,
2026OctEncoder proposedACC0.782Classification · comparison=MCI vs CN · representation=tetrahedral meshHierarchical Mesh Transformers with Topology-Guided Pretraining for Morphometric Analysis of Brain Structures
Source quote
L135: OctEncoder │ 0.907 │ 0.902 │ 0.914 │ 0.731 │ 0.650 │ 0.812 │ 0.782 │ 0.761 │ 0.807 │ 0.763 │ 0.751 │ 0.774
2026Scientific Claim Stability (SCS) proposedMedian support overlap (Jaccard)0.098Classification · pipeline-drift-comparisonA Scientific Claim Stability Framework for Evaluating MRI Morphometry Pipelines
Source quote
L1119: with median evidence Spearman of 0.903, support Jaccard of 0.098, and source-support direction
2026Scientific Claim Stability (SCS) proposedMedian evidence concordance (Spearman)0.903Classification · pipeline-drift-comparisonA Scientific Claim Stability Framework for Evaluating MRI Morphometry Pipelines
Source quote
L1119: with median evidence Spearman of 0.903, support Jaccard of 0.098, and source-support direction
2026Scientific Claim Stability (SCS) proposed non-standard sliceTransfer AUROC0.704Classification · pipeline-drift-comparisonA Scientific Claim Stability Framework for Evaluating MRI Morphometry Pipelines
Source quote
L764: AUROC 0.704;
2026Scientific Claim Stability (SCS) proposedTransfer AUROC0.561Classification · pipeline-drift-comparisonA Scientific Claim Stability Framework for Evaluating MRI Morphometry Pipelines
Source quote
L774: AUROC 0.561;
2026Scientific Claim Stability (SCS) proposed non-standard sliceMedian evidence concordance (Spearman)0.875Classification · pipeline-drift-comparisonA Scientific Claim Stability Framework for Evaluating MRI Morphometry Pipelines
Source quote
L762: 0.875
2026Scientific Claim Stability (SCS) proposed non-standard sliceMedian support overlap (Jaccard)1.000Classification · pipeline-drift-comparisonA Scientific Claim Stability Framework for Evaluating MRI Morphometry Pipelines
Source quote
L763: 1.000
2026MMAP (full model, I + T) proposedBACC0.786Classification · split: test · fine-tunedMMAP: Multimodal Missing-Aware Pretraining for Longitudinal Alzheimer's Prediction
Source quote
L382: 0.786 0.850 0.690 0.733 0.760 0.820
2026Artemis proposedaccuracy84.3%Classification · classes=NC vs. MCIArtemis: Anatomy-Resolved inTervention for Eliminating Multimodal NeuroImage confounderS
Source quote
L278: On ADNI, Artemis achieves 84.3% accuracy, a +5.0% absolute improvement over the best baseline BrainNetCNN (79.3%), and a macro-F1 of 73.5% compared with BrainNetCNN's 52.4%, a +21.1 percentage-point gain that reflects far more balanced recall across the NC and MCI classes.
2026DeCI proposedAccuracy+11.25 ppClassification · split: testMoving Beyond Functional Connectivity: Time-Series Modeling for fMRI-Based Brain Disorder Classification
Source quote
L257: Paired two-sided t-tests on the 5-fold results (Table~\ref{tab:significance}) show that DeCI significantly outperforms Leddam. On ADNI, DeCI improves Accuracy by +11.25\,pp \([8.24, 14.28]\), d_z=4.63, and F1-Score by +22.13\,pp \([13.92, 30.33]\), d_z=3.35 (both p<0.001). On Mātai, Accuracy and F1-Score improve by +3.34\,pp \([0.35, 6.31]\), d_z=1.39, and +4.04\,pp \([0.32, 7.76]\), d_z=1.35 (both p<0.05). On Neurocon, DeCI yields +4.11\,pp in Accuracy \([0.75, 7.47]\), d_z=1.81, and +2.66\,pp in F1-Score \([0.18, 5.14]\), d_z=1.33 (both p<0.05). On TaoWu, DeCI yields +11.50\,pp in Accuracy \([7.96, 15.04]\), d_z=4.03, and +13.83\,pp in F1-Score \([9.71, 17.93]\), d_z=4.17 (both p<0.001). With n{=}5 folds, d_z>1.2 denotes strong, stable improvements, met on Neurocon and Mātai and vastly exceeded on ADNI and TaoWu, highlighting DeCI’s effectiveness and robustness against overfitting on small sample datasets (e.g., Neurocon and TaoWu).
2026DeCI proposedF1-Score+22.13 ppClassification · split: testMoving Beyond Functional Connectivity: Time-Series Modeling for fMRI-Based Brain Disorder Classification
Source quote
L257: Paired two-sided t-tests on the 5-fold results (Table~\ref{tab:significance}) show that DeCI significantly outperforms Leddam. On ADNI, DeCI improves Accuracy by +11.25\,pp \([8.24, 14.28]\), d_z=4.63, and F1-Score by +22.13\,pp \([13.92, 30.33]\), d_z=3.35 (both p<0.001). On Mātai, Accuracy and F1-Score improve by +3.34\,pp \([0.35, 6.31]\), d_z=1.39, and +4.04\,pp \([0.32, 7.76]\), d_z=1.35 (both p<0.05). On Neurocon, DeCI yields +4.11\,pp in Accuracy \([0.75, 7.47]\), d_z=1.81, and +2.66\,pp in F1-Score \([0.18, 5.14]\), d_z=1.33 (both p<0.05). On TaoWu, DeCI yields +11.50\,pp in Accuracy \([7.96, 15.04]\), d_z=4.03, and +13.83\,pp in F1-Score \([9.71, 17.93]\), d_z=4.17 (both p<0.001). With n{=}5 folds, d_z>1.2 denotes strong, stable improvements, met on Neurocon and Mātai and vastly exceeded on ADNI and TaoWu, highlighting DeCI’s effectiveness and robustness against overfitting on small sample datasets (e.g., Neurocon and TaoWu).
2026MM-KG (condition D; Qwen3.5-9B) proposedAUROC.86Classification · split: test · params=9BAligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMs
Source quote
L585: 0.786 (.86)
2026MM-KG multimodal patient representation (clinical history, biomarkers, and imaging) proposedbalanced accuracy0.652ClassificationAligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMs
Source quote
L873: history improves prognosis balanced accuracy from 0.595 to 0.652 (App. L). Removing PrimeKG leaves
2025ConnectomeDiffuser proposedACC71.25%ClassificationConnectomeDiffuser: Generative AI Enables Brain Network Construction From Diffusion Tensor Imaging
Source quote
L314: \multirow{6}{*}{ADNI} │ ConnectomeDiffuser │ 71.25 │ 71.84 │ 71.25 │ 71.09
2025IMMFM-forecast ventricular-area classifier proposedClassification accuracy80.8%Classification · split: test · input=IMMFM-forecast ventricular area · classification=AD-CN · forecast-horizon=36 monthsLongitudinal Flow Matching for Trajectory Modeling
Source quote
L351: Finally, we examine the specific progression of the disease. For the ADNI dataset, we focus on the ventricle region, as ventricular enlargement is a well-studied biomarker of AD progression and its underlying neurodegenerative process \citep{nestor2008ventricular}. IMMFM captures distinct ventricular growth trajectories for AD versus CN groups without explicit class conditioning (Fig.~\ref{fig:ad_dist}). Using only observed data at the second visit (\sim18 months), AD–CN classification reaches \bm{71.7%}. When using trajectories forecasted by our model to \sim36 months, AD-CN classification accuracy increases to \bm{80.8%}, a \bm{9.1%} gain. In practical terms, this corresponds to correctly classifying about nine additional subjects per 100, 18 months earlier than would be possible using only the observed data (see Appendix~\ref{app:classification_details} for additional details).
2025Heter-LBI (proposed method; table label “Ours”) proposedclassification accuracy88.96%Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=1.5TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L490: 88.96%
2025Heter-LBI (proposed method; table label “Ours”) proposedclassification accuracy91.48%Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=3.0TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L491: 91.48%
2025Heter-LBI (proposed method; table label “Ours”) proposedclassification accuracy74.00%Classification · split: val · comparison=MCI-vs-NC · validation=10-fold cross-validation · field-strength=1.5TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L492: 74.00% is enforced with spatial smoothness and non-negativity constraint to learn the lesion features and a dense parameter to additionally learn the procedural bias.
2025CoCoLIT proposedBA (balanced accuracy for Aβ-positivity classification)62.3%Classification · split: test · method-setting=LAS m=64 · classification-threshold=selected on internal validation setCoCoLIT: ControlNet-Conditioned Latent Image Translation for MRI to Amyloid PET Synthesis
Source quote
L163: m=64 │ 0.896 ± 0.050 │ 24.135 ± 2.820 │ 0.0050 ± 0.0047 │ 0.328~(p<0.001) │ 0.522~(p<0.001) │ 62.3%
2025InfoDPCCA Step II proposedNMI1.000Classification · semi-supervisedInfoDPCCA: Information-Theoretic Dynamic Probabilistic Canonical Correlation Analysis
Source quote
L476: Step II │ 1.000/0.908 │ 0.642/0.620 │ 0.228/0.586
2025MedOrch (o1-mini, best@5) proposedAccuracy93.26%ClassificationMedOrch: Medical Diagnosis with Tool-Augmented Reasoning Agents for Flexible Extensibility
Source quote
L262: Diagnostic Performance. On the three-class AD vs. MCI vs. NC classification task, \texttt{MedOrch}\xspace with o1-mini using the best@5 strategy achieves the highest accuracy of 93.26%, outperforming all baseline methods, including the previous state-of-the-art ConvNext+GPT approach (89.05%). This represents a 4.21% absolute improvement in accuracy. Similar patterns are observed in the four-class classification tasks (AD vs. EMCI vs. LMCI vs. NC), where \texttt{MedOrch}\xspace consistently outperforms baselines across all metrics. The significant improvement highlights the value of \texttt{MedOrch}\xspace' dynamic tool-calling approach, which can adapt its information-gathering strategy to each specific case.
2025MedOrch proposedAccuracy50.35%ClassificationMedOrch: Medical Diagnosis with Tool-Augmented Reasoning Agents for Flexible Extensibility
Source quote
L264: Prediction Performance. The disease progression prediction task proves more challenging for all. However, \texttt{MedOrch}\xspace shows a more pronounced advantage in this setting, achieving 50.35% accuracy with the best@5 and 38.61% with best@1. This significant lead over the baselines highlights \texttt{MedOrch}\xspace' superior ability to analyze temporal patterns in patient data and identify relevant progression indicators through its specialized tools and agents.
2025FLIQA-AD proposed non-standard sliceclassification accuracy (ACC)97%Classification · split: test · subset=300 samples per category · sampling=patient-levelFLIQA-AD: a Fusion Model with Large Language Model for Better Diagnose and MMSE Prediction of Alzheimer's Disease
Source quote
L202: 97% and 95%.
2025M3D + LGA proposedACC76.7%Classification · fine-tuned · runs=5 · backbone=M3D · component=LGA · training-samples=1,504Data-Efficient Fine-Tuning of Vision-Language Models for Diagnosis of Alzheimer's Disease
Source quote
L235: \quad + LGA~\cite{hu2024lga} │ 76.7 │ 80.0 │ + 85.2M │ 1,504
2025Proposed spatial-temporal transformer (Ours; temporal and spatial blocks) proposedACC89.1Classification · split: val · 5-fold-cv · evaluation=subject-levelClassification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal Transformer
Source quote
L148: 89.1
2025Proposed spatial-temporal transformer (Ours; temporal and spatial blocks) proposedF190.3Classification · split: val · 5-fold-cv · evaluation=subject-levelClassification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal Transformer
Source quote
L152: 90.3 os-FC: original static FC; S/T-only: Using only the spatial/ temporal block
2025Proposed framework with contrastive learning proposedAccuracy improvement9.7%Classification · split: val · 5-fold-cv · component=contrastive-learning · comparison=without-contrastive-learning · evaluation=subject-levelClassification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal Transformer
Source quote
L114: To verify our proposed model, we compare it with other widely used methods in the literature listed in Table 1. Our results outperform most other studies. Furthermore, the proposed method incorporating contrastive learning strategy performs significantly better than the method without contrastive learning strategy on this data, showing an improvement of 9.7% in accuracy and 7.3% in F1 score when contrastive learning is applied.
2025Proposed framework with contrastive learning proposedF1 improvement7.3%Classification · split: val · 5-fold-cv · component=contrastive-learning · comparison=without-contrastive-learning · evaluation=subject-levelClassification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal Transformer
Source quote
L114: To verify our proposed model, we compare it with other widely used methods in the literature listed in Table 1. Our results outperform most other studies. Furthermore, the proposed method incorporating contrastive learning strategy performs significantly better than the method without contrastive learning strategy on this data, showing an improvement of 9.7% in accuracy and 7.3% in F1 score when contrastive learning is applied.
2025SFC-GAN (translated FC) proposed non-standard sliceAccuracy16.67Classification · split: testSFC-GAN: A Generative Adversarial Network for Brain Functional and Structural Connectome Translation
Source quote
L161: Translated FC │ 16.67 │ 11.11 │ 16.67 │ 12.50 │ 52.18
2025SFC-GAN (translated SC) proposed non-standard sliceAccuracy41.67Classification · split: testSFC-GAN: A Generative Adversarial Network for Brain Functional and Structural Connectome Translation
Source quote
L162: Translated SC │ 41.67 │ 27.78 │ 41.67 │ 33.33 │ 57.78
2025Reinforced Domain Selection proposedAccuracy90.5ClassificationReinforced Domain Selection for Continuous Domain Adaptation
Source quote
L180: Ours │ 93.4 │ 90.5
2024SOE, self-supervised pretrained on ADNI (self-training) proposedBACC83.84Classification · pretraining-dataset=ADNISOE: SO(3)-Equivariant 3D MRI Encoding
Source quote
L88: First, we evaluated our proposed method with regard to its generalizability across datasets. We examined the classification and age regression performance on ADNI of models without pretraining, pretrained with SOE on the NCANDA dataset, and pretrained with SOE on the ADNI dataset. In Table \ref{NCANDA_pretraining}, we observe that our proposed SOE pretraining performs better than the no pretraining instance for both ADNI NC vs. AD classification and age prediction tasks by 0.5-8% in terms of BACC. Furthermore, we observe that pretraining our model on the same dataset (ADNI) as the downstream task evaluation, the so-called ``self-training", outperforms the model pretrained on NCANDA in classification (AUC 91.3 vs. 91.1; BACC 83.84 vs. 82.81; F1 79.38 vs. 78.50). Particularly when evaluated on the task of age prediction, our representation learning framework outperforms the model with no pretraining (R2 0.45 vs. 0.41; MAE 5.88 vs. 5.95).
2024SOE, self-supervised pretrained on NCANDA proposedBACC82.81Classification · pretraining-dataset=NCANDASOE: SO(3)-Equivariant 3D MRI Encoding
Source quote
L88: First, we evaluated our proposed method with regard to its generalizability across datasets. We examined the classification and age regression performance on ADNI of models without pretraining, pretrained with SOE on the NCANDA dataset, and pretrained with SOE on the ADNI dataset. In Table \ref{NCANDA_pretraining}, we observe that our proposed SOE pretraining performs better than the no pretraining instance for both ADNI NC vs. AD classification and age prediction tasks by 0.5-8% in terms of BACC. Furthermore, we observe that pretraining our model on the same dataset (ADNI) as the downstream task evaluation, the so-called ``self-training", outperforms the model pretrained on NCANDA in classification (AUC 91.3 vs. 91.1; BACC 83.84 vs. 82.81; F1 79.38 vs. 78.50). Particularly when evaluated on the task of age prediction, our representation learning framework outperforms the model with no pretraining (R2 0.45 vs. 0.41; MAE 5.88 vs. 5.95).
2024TabSeq proposedAccuracy64.44%Classification · partition=70:15:15 · feature-ordering=without · target-attribute=ABETA12TabSeq: A Framework for Deep Learning on Tabular Data via Sequential Ordering
Source quote
L254: TabSeq (ours) │ 64.44% │ 0.55 │ 75.13% │ 0.71
2024TabSeq proposedAccuracy75.13%Classification · partition=70:15:15 · feature-ordering=with; k-means, 5 clusters, ascending · target-attribute=ABETA12TabSeq: A Framework for Deep Learning on Tabular Data via Sequential Ordering
Source quote
L254: TabSeq (ours) │ 64.44% │ 0.55 │ 75.13% │ 0.71
2024PLM proposedACC0.8693Classification · split: testConnectional-style-guided contextual representation learning for brain disease diagnosis
Source quote
L328: 0.8693
2024MORPHADE (unsupervised) proposedAUROC0.80Classification · split: test · method=unsupervised · training=760 healthy controlsUnsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable Autoencoders
Source quote
L96: In this section, we assess the capability of MORPHADE in detecting AD at the patient level. Table \ref{tab::benchmark_anomaly_detection} shows the Area Under the Receiver Operating Characteristic curve (AUROC) scores obtained when comparing our method to various baselines for identifying subjects with AD compared to healthy control (HC) subjects. Our model achieves an AUROC of 0.80, surpassing even the 3D supervised baselines ResNet \cite{supervised_resnet} and DenseNet \cite{supervised_densenet}, with AUROCs of 0.77 and 0.74, respectively.
2024CLiP-ICA proposedmodality coupled sources44 sourcesClassification · backbone=CLiP · modalities=sMRI and fMRICopula-Linked Parallel ICA: A Method for Coupling Structural and Functional MRI brain Networks
Source quote
L142: Domains including SC, AU and CB have mostly highly linked components while other higher cognitive domains such as SM, VI, CC and DM have both highly linked and low linked components. This resulted in 44 modality coupled sources and 7 modality unique sources, 6 from fMRI and 1 from sMRI. This illustrates the power and flexibility of the proposed model, and suggests it is not artificially creating linkages, but rather encourages the linkage up until the data allows. The
2024CLiP-ICA proposedmodality unique sources7 sourcesClassification · backbone=CLiP · modalities=sMRI and fMRICopula-Linked Parallel ICA: A Method for Coupling Structural and Functional MRI brain Networks
Source quote
L142: Domains including SC, AU and CB have mostly highly linked components while other higher cognitive domains such as SM, VI, CC and DM have both highly linked and low linked components. This resulted in 44 modality coupled sources and 7 modality unique sources, 6 from fMRI and 1 from sMRI. This illustrates the power and flexibility of the proposed model, and suggests it is not artificially creating linkages, but rather encourages the linkage up until the data allows. The
2023WSEK (weighted subspace exponential kernel) proposedaverage classification accuracy79%Classification · split: val · modality=fMRI · classifier=KSTM · rank-selection=best average over Tucker ranks 1–10A weighted subspace exponential kernel for support tensor machines
Source quote
L381: (79% for ADNI and 64% for ADHD) compared to other state of the art tensor kernels. We note that the accuracy of the subspace kernel improves for higher ranks in the ADHD dataset and is then similar to that of WSEK but this choice of rank is very high for a low-rank truncation method. On the other hand, our proposed kernel gives good classification accuracy already at rank 2. The Gaussian kernel was computed for different Tucker approximations of the full tensor. Using the full tensor in the computation of the kernel did not improve the accuracy. As in~\cite{KourJMLR}, the DuSK kernel was computed using a CP approximation of the full tensor (CP-DuSK), because computing the Tucker decomposition and then converting to CP yielded high CP ranks and DuSK was too slow.
2023tLSSVM-MTL proposedACC98.17%Classification · split: test · tasks=4 × 4 × 3 · kernel=RBF · training-sample-ratio=0.3Low-Rank Multitask Learning based on Tensorized SVMs and LSSVMs
Source quote
L743: tLSSVM-MTL │ 98.17% │ 97.85% │ 98.48% │ 98.16%\% │ 5.31
2023GE-IFRVFL-CIL-1 proposedAverage AUC0.757Classification · comparisons=CN_vs_AD, CN_vs_MCI, MCI_vs_AD · comparison_count=3Graph Embedded Intuitionistic Fuzzy Random Vector Functional Link Neural Network for Class Imbalance Learning
Source quote
L318: Average AUC │ 0.7212 │ 0.6618 │ 0.6873 │ 0.7519 │ 0.7273 │ 0.7555 │ \bm{0.757} │ 0.7486
2021Projected group lasso (p_glasso) proposedNumber of significantly associated voxels14297 voxelsClassification · split: test · slices=nine axial slices · timepoint=month-12Multi-Task Learning with High-Dimensional Noisy Images
Source quote
L326: p\_glasso │ \bf{0.96} │ \bf{0.92} │ \bf{0.89} │ \bf{0.87} │ \bf{0.91} │ \bf{0.97} │ {\bf 0.98} │ \bf{0.90} │ \bf{0.88} │ 1370 │ 1329 │ 976 │ 1646 │ 1718 │ 702 │ 2024 │ 1915 │ 2617 │ 14297
2021Proposed hierarchical approach (P) proposedC-index.91Classification · split: testA Hierarchical Approach to Multi-Event Survival Analysis
Source quote
L361: .91(.88-.93)
2021Proposed hierarchical approach (P) proposedLocal consistency.97Classification · split: testA Hierarchical Approach to Multi-Event Survival Analysis
Source quote
L363: .97(.94-.98)
2020TT-MMK proposedAverage classification accuracy73%Classification · split: val · 5-fold-cross-validation · data=resting-state fMRI · classes=AD+MCI vs normal controls · subjects=33 · repetitions=50Efficient Structure-preserving Support Tensor Train Machine
Source quote
L515: TT-MMK │ 73 │ 64 │ 99 │ 99
2019Proposed method (Bayesian segmentation with sMRI and dMRI) proposedsample size20 samplesClassification · analysis=linear discriminant analysis · modality=sMRI+dMRI · validation=leave-one-outJoint inference on structural and diffusion MRI for sequence-adaptive Bayesian segmentation of thalamic nuclei with probabilistic atlases
Source quote
L255: Sample size │ 50 │ 26 │ 20
2019Linear SVM using morphological age and disease score proposedMean classification accuracy0.59Classification · split: val · classes=MCI stable vs MCI converters · classifier=linear SVM · validation=10-fold cross-validationA model of brain morphological changes related to aging and Alzheimer's disease from cross-sectional assessments
Source quote
L291: We also perform a simple linear classification task between the MCIs and MCIc groups using this two cross-sectional markers. A SVM linear classifier is fitted to the full data-set to perform the binary classification\footnote{The classification task was performed using the SVC module of the scikit-learn python library~\citep{scikit-learn}}. The error penalty weights are adjusted between the two classes to balance the trade-off between false positive and false negative rate. The mean classification accuracy using a 10-folds cross-validation scheme is equal to 0.59. The linear decision function is equivalent to the projection on the SVF v_A - 0.003 v_D, so the differences between MCIs and MCIc subjects is, in our model, only associated with the aging trajectory while the disease specific changes do not seem to have an impact before the conversion. For comparison, for the same experiment between CN and AD, the linear classifier corresponds to the projection on v_A + 0.49 v_D so approximately (v-bn + v-ad) / 2, i.e. the mean evolution of the whole population. Of course, in both cases we do not reach the performance of state-of-the-art dedicated algorithm but it allows us to see how both markers are associated with the diagnosis. Moreover this discriminant approach could be extended by using information in a subset of targeted areas.
2018CNN (MRI-only) proposed non-standard sliceAccuracy92%Classification · split: test · subset=1,299 scans · modality=MRINeuroimaging modality fusion in Alzheimer’s classification using convolutional neural networks
Source quote
L80: MRI │ 92%
2018CNN (PET-only) proposed non-standard sliceAccuracy85%Classification · split: test · subset=585 scans · modality=amyloid PETNeuroimaging modality fusion in Alzheimer’s classification using convolutional neural networks
Source quote
L81: PET │ 85%
2018CNN (MRI+PET fusion) proposed non-standard sliceAccuracy94%Classification · split: test · subset=585 paired data points · modality=MRI+amyloid PET fusionNeuroimaging modality fusion in Alzheimer’s classification using convolutional neural networks
Source quote
L82: Fusion │ 94%
2018Proposed atlas, whole-thalamic volume computed by summing nuclei; volume thresholding proposedarea under the curve (AUC)0.645Classification · cohort=213 Alzheimer's disease; 161 controls · features=whole-thalamic volumeA probabilistic atlas of the human thalamic nuclei combining ex vivo MRI and histology
Source quote
L272: The receiver operating characteristic (ROC) curves are shown in Figure~\ref{fig:ROC}. The area under the curve (AUC), which is a threshold-independent measure of performance for a classifier, was 0.632 for the thalamic volumes given Freesurfer's main stream. When using the whole thalamic volumes given by the proposed atlas, the AUC was slightly higher (AUC = 0.645), though the difference was not statistically significant (p = 0.4) according to a paired DeLong test \citep{delong1988comparing}. However, when using all nuclei simultaneously, the AUC increased considerably to 0.830 (p \sim 10 (-10) against the whole thalamic volumes, given by \texttt{recon-all} or our proposed atlas).
2018Proposed atlas-estimated volumes of all nuclei, leave-one-out linear discriminant analysis (LDA) proposedarea under the curve (AUC)0.830Classification · cohort=213 Alzheimer's disease; 161 controls · features=volumes of all nuclei · classifier=leave-one-out LDAA probabilistic atlas of the human thalamic nuclei combining ex vivo MRI and histology
Source quote
L272: The receiver operating characteristic (ROC) curves are shown in Figure~\ref{fig:ROC}. The area under the curve (AUC), which is a threshold-independent measure of performance for a classifier, was 0.632 for the thalamic volumes given Freesurfer's main stream. When using the whole thalamic volumes given by the proposed atlas, the AUC was slightly higher (AUC = 0.645), though the difference was not statistically significant (p = 0.4) according to a paired DeLong test \citep{delong1988comparing}. However, when using all nuclei simultaneously, the AUC increased considerably to 0.830 (p \sim 10 (-10) against the whole thalamic volumes, given by \texttt{recon-all} or our proposed atlas).
2014LR+GFL (logistic regression with generalized fused lasso) proposedaccuracy84.21%Classification · split: 10-fold-cv · cohort=AD vs healthy controls · modality=MRI · field-strength=1.5TEfficient Generalized Fused Lasso and its Application to the Diagnosis of Alzheimer's Disease
Source quote
L377: 84.21%
2014LR+GFL (logistic regression with generalized fused lasso) proposedaccuracy70.92%Classification · split: 10-fold-cv · cohort=MCI converters vs non-converters · modality=MRI · field-strength=1.5TEfficient Generalized Fused Lasso and its Application to the Diagnosis of Alzheimer's Disease
Source quote
L382: 70.92%
2012QDA proposedAUC0.72Classification · features=shape, PET, APOE carrier status · weighting=η=0.8 · classifier=QDAGenetic, Structural and Functional Imaging Biomarkers for Early Detection of Conversion from MCI to AD
Source quote
L129: 0.72
2012QDA proposedAcc (%)66.14%Classification · features=shape, PET, APOE carrier status · weighting=η=0.8 · classifier=QDAGenetic, Structural and Functional Imaging Biomarkers for Early Detection of Conversion from MCI to AD
Source quote
L130: 66.14
2012QDA proposedaccuracy68%Classification · features=shape, PET, APOE carrier status, CSF Aβ-42 and ptau181 · weighting=η=0.8 · classifier=QDAGenetic, Structural and Functional Imaging Biomarkers for Early Detection of Conversion from MCI to AD
Source quote
L214: 29 NL, 36 AD and 59 MCI. With CSF-biomarkers, a slight increase in accuracy was observed for QDA: accuracy=68% and AUC= 0.72 (η = 0.8).
2012QDA proposedAUC0.72Classification · features=shape, PET, APOE carrier status, CSF Aβ-42 and ptau181 · weighting=η=0.8 · classifier=QDAGenetic, Structural and Functional Imaging Biomarkers for Early Detection of Conversion from MCI to AD
Source quote
L214: 29 NL, 36 AD and 59 MCI. With CSF-biomarkers, a slight increase in accuracy was observed for QDA: accuracy=68% and AUC= 0.72 (η = 0.8).