ADNI · Binary Classification

202 papers · 607 extracted observations · classification · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Binary Classification, split=test.

87.489.491.493.42026Ours (DTI+text): 92.94 (2025)DinoAtten3D: 87.8 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 27 of 27 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025Cycle-GAN generative imputation proposedF1 score0.88Binary Classification · modalities=T1 and FNCA Generative Imputation Method for Multimodal Alzheimer's Disease Diagnosis
Source quote
L109: Using the real T1 and FNC data along with the generated data we trained a multi-modal classification of AD vs. CN and measured the performance of the model with the accuracy, precision, recall, and F1 score. Moreover, we compared the performance of the model with the following baselines: 1. subsampling, where the input data includes only the data for which both modalities are available; and 2. zero-imputation, where the missing modality is replaced with zeros. Fig. \ref{fig:performance} shows a summary of the performance of each approach. According to the results, our generative-imputation approach achieved an accuracy of 86.87%±2.9 and outperformed the subsampling and zero-imputation approaches by 8.6% and 9.4%, respectively. Furthermore, our proposed approach attained an F1 score of 0.88, a recall of 0.86, and a precision of 0.91, all of which were superior to the baselines.
2025Cycle-GAN generative imputation proposedrecall0.86Binary Classification · modalities=T1 and FNCA Generative Imputation Method for Multimodal Alzheimer's Disease Diagnosis
Source quote
L109: Using the real T1 and FNC data along with the generated data we trained a multi-modal classification of AD vs. CN and measured the performance of the model with the accuracy, precision, recall, and F1 score. Moreover, we compared the performance of the model with the following baselines: 1. subsampling, where the input data includes only the data for which both modalities are available; and 2. zero-imputation, where the missing modality is replaced with zeros. Fig. \ref{fig:performance} shows a summary of the performance of each approach. According to the results, our generative-imputation approach achieved an accuracy of 86.87%±2.9 and outperformed the subsampling and zero-imputation approaches by 8.6% and 9.4%, respectively. Furthermore, our proposed approach attained an F1 score of 0.88, a recall of 0.86, and a precision of 0.91, all of which were superior to the baselines.
2025Cycle-GAN generative imputation proposedprecision0.91Binary Classification · modalities=T1 and FNCA Generative Imputation Method for Multimodal Alzheimer's Disease Diagnosis
Source quote
L109: Using the real T1 and FNC data along with the generated data we trained a multi-modal classification of AD vs. CN and measured the performance of the model with the accuracy, precision, recall, and F1 score. Moreover, we compared the performance of the model with the following baselines: 1. subsampling, where the input data includes only the data for which both modalities are available; and 2. zero-imputation, where the missing modality is replaced with zeros. Fig. \ref{fig:performance} shows a summary of the performance of each approach. According to the results, our generative-imputation approach achieved an accuracy of 86.87%±2.9 and outperformed the subsampling and zero-imputation approaches by 8.6% and 9.4%, respectively. Furthermore, our proposed approach attained an F1 score of 0.88, a recall of 0.86, and a precision of 0.91, all of which were superior to the baselines.
2025DinoAtten3D proposedaccuracy87.80%Binary Classification · split: testDinoAtten3D: Slice-Level Attention Aggregation of DinoV2 for 3D Brain MRI Anomaly Classification
Source quote
L177: For HC vs.\ AD, our model achieves 87.80% accuracy with an F_1 score of 0.871 in the test set after selecting the model with the lowest validation loss.
2025DinoAtten3D proposedAUC0.865Binary Classification · split: testDinoAtten3D: Slice-Level Attention Aggregation of DinoV2 for 3D Brain MRI Anomaly Classification
Source quote
L178: As shown in Figure~\ref{fig:cn_ad}, 174/184 HC and 99/127 AD scans are correctly classified with 0.865 AUC, indicating good convergence and limited overfitting in terms of Alzheimer's disease detection. It also achieves better accuracy and AUC compared to the baselines.
2025NSA-Flow (NSA) proposedAUC0.675Binary Classification · split: val · classifier=random-forest · comparison=CN vs MCI · evaluation=two runs of 4-fold cross-validationNon-Negative Stiefel Approximating Flow: Orthogonalish Matrix Optimization for Interpretable Embeddings
Source quote
L829: CN vs MCI │ NSA │ 0.663 │ 0.681 │ 0.772 │ 0.586 │ {\itshape {0.675}}
2025Ours (DTI+text) proposedACC92.94%Binary Classification · split: test · modalities=DTI+clinical-text · train-test-split=80/20Bridging Brain Connectomes and Clinical Reports for Early Alzheimer's Disease Diagnosis
Source quote
L408: 92.94
2025Ours (DTI+text) proposedSEN93.0%Binary Classification · split: test · modalities=DTI+clinical-text · train-test-split=80/20Bridging Brain Connectomes and Clinical Reports for Early Alzheimer's Disease Diagnosis
Source quote
L409: 93.0
2024ADAPT (1+1+2+2 encoder-layer configuration) proposedtest acc.0.924Binary Classification · split: test · slices=48 total; 16 per view · classes=AD/normal · sampling=important sampling · configuration=1+1+2+2 encoder layersADAPT: Alzheimer Diagnosis through Adaptive Profiling Transformers
Source quote
L397: 0.924
2023BSFL (proposed; listed as “Ours”; GCN classifier) proposed non-standard sliceAUC93.88%Binary Classification · split: val · classifier=GCN · comparison=SMC-vs-NC · modalities=DTI-and-fMRI · validation=10-fold-cross-validationBrain Structure-Function Fusing Representation Learning using Adversarial Decomposed-VAE for Analyzing MCI
Source quote
L274: Ours │ {\bfseries 85.97} │ {\bfseries 96.34} │ {\bfseries 75.61} │ {\bfseries 93.88} │ {\bfseries 90.85} │ {\bfseries 93.90} │ {\bfseries 87.80} │ {\bfseries 97.85} │ {\bfseries 94.30} │ {\bfseries 93.42} │ 95.12 │ {\bfseries 98.12}
2023BSFL (proposed; listed as “Ours”; GCN classifier) proposed non-standard sliceAUC98.12%Binary Classification · split: val · classifier=GCN · comparison=LMCI-vs-NC · modalities=DTI-and-fMRI · validation=10-fold-cross-validationBrain Structure-Function Fusing Representation Learning using Adversarial Decomposed-VAE for Analyzing MCI
Source quote
L274: Ours │ {\bfseries 85.97} │ {\bfseries 96.34} │ {\bfseries 75.61} │ {\bfseries 93.88} │ {\bfseries 90.85} │ {\bfseries 93.90} │ {\bfseries 87.80} │ {\bfseries 97.85} │ {\bfseries 94.30} │ {\bfseries 93.42} │ 95.12 │ {\bfseries 98.12}
2022Proposed layer-wise partitioning and merging proposedACC (accuracy)0.94Binary Classification · gpus=1 · model=3D-ResAttNet34 · comparison=AD vs. NCLayer-wise partitioning and merging for efficient and scalable deep learning
Source quote
L234: 1 │ 0.79 │ 29 │ 0.93 │ 55 │ 0.81 │ 34 │ 0.94 │ 61\tabularnewline
2022Proposed layer-wise partitioning and merging proposedACC (accuracy)0.94Binary Classification · gpus=8 · model=3D-ResAttNet34 · comparison=AD vs. NCLayer-wise partitioning and merging for efficient and scalable deep learning
Source quote
L241: 8 │ 0.80 │ 3 │ 0.93 │ 7 │ 0.82 │ 4 │ 0.94 │ 8 \tabularnewline
2021DecGAN (t=2, k=5) proposed non-standard sliceACC92.59%Binary Classification · split: val · k=5 · t=2 · classes=AD vs NC · validation=five-foldDecGAN: Decoupling Generative Adversarial Network detecting abnormal neural circuits for Alzheimer's disease
Source quote
L354: The top two highest ACC value of 92.59% and 88.90% are achieved at (t,k)=(2,5) and (t,k)=(1,8).
2021DecGAN (t=1, k=8) proposed non-standard sliceACC88.90%Binary Classification · split: val · k=8 · t=1 · classes=AD vs NC · validation=five-foldDecGAN: Decoupling Generative Adversarial Network detecting abnormal neural circuits for Alzheimer's disease
Source quote
L354: The top two highest ACC value of 92.59% and 88.90% are achieved at (t,k)=(2,5) and (t,k)=(1,8).
2019LSTM-Robust proposedAUC0.9029Binary Classification · split: test · classes=CN-vs-AD · classifier=LDATraining recurrent neural networks robust to incomplete data: application to Alzheimer's disease progression modeling
Source quote
L230: CN vs. AD │ 0.9029^{\star\star\star/\star\star\star/\star\star\star} │ 0.8404 │ 0.8150 │ 0.7826
2018Proposed end-to-end 3D-CNN proposedAcc%94.1%Binary Classification · modality=MRIEnd-To-End Alzheimer's Disease Diagnosis and Biomarker Identification
Source quote
L119: Ours │ MRI │ 94.1 │ 0.94 │ 0.91
2014Proposed method (MPC: MRI+PET+CSF) proposedACC (accuracy)95.9%Binary Classification · split: val · data=baseline · modalities=MRI+PET+CSF · validation=10-fold cross-validation repeated 10 timesMatrix-Similarity Based Loss Function and Feature Selection for Alzheimer's Disease Diagnosis
Source quote
L243: MP and MPC were better than the same methods with single-modality data such as MRI and PET. Also, the classification performance by MPC was generally better than MP. For example, in the discrimination between AD and NC, the proposed method with MPC achieved the classification accuracy of 95.9%, sensitivity of 95.7%, specificity of 98.6%, and AUC of 98.8%, while the best performance among other competing methods with single-modality data was 93.8% (ACC),
2014Proposed method (MPC: MRI+PET+CSF) proposedSEN (sensitivity)95.7%Binary Classification · split: val · data=baseline · modalities=MRI+PET+CSF · validation=10-fold cross-validation repeated 10 timesMatrix-Similarity Based Loss Function and Feature Selection for Alzheimer's Disease Diagnosis
Source quote
L243: MP and MPC were better than the same methods with single-modality data such as MRI and PET. Also, the classification performance by MPC was generally better than MP. For example, in the discrimination between AD and NC, the proposed method with MPC achieved the classification accuracy of 95.9%, sensitivity of 95.7%, specificity of 98.6%, and AUC of 98.8%, while the best performance among other competing methods with single-modality data was 93.8% (ACC),
2014Proposed method (MPC: MRI+PET+CSF) proposedSPE (specificity)98.6%Binary Classification · split: val · data=baseline · modalities=MRI+PET+CSF · validation=10-fold cross-validation repeated 10 timesMatrix-Similarity Based Loss Function and Feature Selection for Alzheimer's Disease Diagnosis
Source quote
L243: MP and MPC were better than the same methods with single-modality data such as MRI and PET. Also, the classification performance by MPC was generally better than MP. For example, in the discrimination between AD and NC, the proposed method with MPC achieved the classification accuracy of 95.9%, sensitivity of 95.7%, specificity of 98.6%, and AUC of 98.8%, while the best performance among other competing methods with single-modality data was 93.8% (ACC),
2014Proposed method (MPC: MRI+PET+CSF) proposedAUC98.8%Binary Classification · split: val · data=baseline · modalities=MRI+PET+CSF · validation=10-fold cross-validation repeated 10 timesMatrix-Similarity Based Loss Function and Feature Selection for Alzheimer's Disease Diagnosis
Source quote
L243: MP and MPC were better than the same methods with single-modality data such as MRI and PET. Also, the classification performance by MPC was generally better than MP. For example, in the discrimination between AD and NC, the proposed method with MPC achieved the classification accuracy of 95.9%, sensitivity of 95.7%, specificity of 98.6%, and AUC of 98.8%, while the best performance among other competing methods with single-modality data was 93.8% (ACC),
2014Proposed method (MPC: MRI+PET+CSF) proposedACC (accuracy)82.0%Binary Classification · split: val · data=baseline · modalities=MRI+PET+CSF · validation=10-fold cross-validation repeated 10 timesMatrix-Similarity Based Loss Function and Feature Selection for Alzheimer's Disease Diagnosis
Source quote
L510: 82.0
2014Proposed method (MPC: MRI+PET+CSF) proposedAUC87.0%Binary Classification · split: val · data=baseline · modalities=MRI+PET+CSF · validation=10-fold cross-validation repeated 10 timesMatrix-Similarity Based Loss Function and Feature Selection for Alzheimer's Disease Diagnosis
Source quote
L513: 87.0
2014CB-SVM (proposed coupled boosting) proposedACC (classification accuracy)94.7%Binary Classification · split: val · comparison=AD vs NC · modalities=MRI+PET · validation=10-fold cross-validation repeated 100 timesJoint Coupled-Feature Representation and Coupled Boosting for AD Diagnosis
Source quote
L8: Specifically, we formulate a new weight updating function, which considers both incorrectly and inconsistently classified samples. In our experiments on the ADNI dataset, the proposed method presented the best performance with accuracies of 94.7% and 80.1% for AD vs. Normal Control (NC) and MCI vs. NC classifications, respectively, outperforming the competing methods and the state-of-the-art methods.
2014CB-SRC (proposed coupled boosting) proposedACC (classification accuracy)80.1%Binary Classification · split: val · comparison=MCI vs NC · modalities=MRI+PET · validation=10-fold cross-validation repeated 100 timesJoint Coupled-Feature Representation and Coupled Boosting for AD Diagnosis
Source quote
L8: Specifically, we formulate a new weight updating function, which considers both incorrectly and inconsistently classified samples. In our experiments on the ADNI dataset, the proposed method presented the best performance with accuracies of 94.7% and 80.1% for AD vs. Normal Control (NC) and MCI vs. NC classifications, respectively, outperforming the competing methods and the state-of-the-art methods.
2014CB-SVM (proposed coupled boosting) proposedAUC0.975Binary Classification · split: val · comparison=AD vs NC · modalities=MRI+PET · validation=10-fold cross-validation repeated 100 timesJoint Coupled-Feature Representation and Coupled Boosting for AD Diagnosis
Source quote
L386: MCI vs. NC (by CB-SRC) classifications. Regarding AUCs, we repeated the 10-fold CV 100 times to reduce the possible bias caused by different data partition, and then obtained the mean AUC value. Our best AUCs were 0.975 (AD vs.
2014CB-SRC (proposed coupled boosting) proposedAUC0.833Binary Classification · split: val · comparison=MCI vs NC · modalities=MRI+PET · validation=10-fold cross-validation repeated 100 timesJoint Coupled-Feature Representation and Coupled Boosting for AD Diagnosis
Source quote
L387: NC) and 0.833 (MCI vs. NC), better than results in [21].