ADNI
202 papers · 607 extracted observations · classification · Markdown · CSV · JSON API
Tasks on ADNIAll tasks (202)Classification (44)Alzheimer Disease Classification (13)Binary Classification (13)Disease Classification (13)Image Classification (5)Medical Image Classification (5)Image Generation (4)Image Reconstruction (4)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Proposed/measured results matching task=Classification.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | MedOrch (o1-mini, best@5) SOTA frontier (+1 variant) | 93.26% | 2025-06-01 | Three-class AD vs. MCI vs. NC diagnosis; best@5 counts a case correct if any of five … | MedOrch: Medical Diagnosis with Tool-Augmented Reasoning Agents for Flexible ExtensibilitySource quoteDiagnostic Performance. On the three-class AD vs. MCI vs. NC classification task, \texttt{MedOrch}\xspace with o1-mini using the best@5 strategy achieves the highest accuracy of 93.26%, outperforming all baseline methods, including the previous state-of-the-art ConvNext+GPT approach (89.05%). This represents a 4.21% absolute improvement in accuracy. Similar patterns are observed in the four-class classification tasks (AD vs. EMCI vs. LMCI vs. NC), where \texttt{MedOrch}\xspace consistently outperforms baselines across all metrics. The significant improvement highlights the value of \texttt{MedOrch}\xspace' dynamic tool-calling approach, which can adapt its information-gathering strategy to each specific case. |
| 2 | Reinforced Domain Selection (+1 variant) | 90.5% | 2025-10-01 | CDA comparison with four intermediate domains; ADNI classification across five diseas… | Reinforced Domain Selection for Continuous Domain AdaptationSource quoteOurs │ 93.4 │ 90.5 |
| 3 | MST-former (3 scales) SOTA frontier (+1 variant) | 90.3% | 2024-02-01 | resolution=256x256 · Next-status prediction among NC, MCI, and AD from clips of 3 MRI scans (256×256×256). | Multi-Scale Spatio-Temporal Transformer-Based Imbalanced Longitudinal Learning for Glaucoma Forecasting From Irregular Time Series ImagesSource quoteOurs │ 0.966 │ 90.3 │ 87.0 │ 94.2 |
| 4 | Artemis | 84.3% | 2026-06-01 | classes=NC vs. MCI · ADNI benchmark task: NC vs. MCI; reported score. | Artemis: Anatomy-Resolved inTervention for Eliminating Multimodal NeuroImage confounderSSource quoteOn ADNI, Artemis achieves 84.3% accuracy, a +5.0% absolute improvement over the best baseline BrainNetCNN (79.3%), and a macro-F1 of 73.5% compared with BrainNetCNN's 52.4%, a +21.1 percentage-point gain that reflects far more balanced recall across the NC and MCI classes. |
| 5 | M3D + LGA | 76.7% | 2025-09-01 | runs=5 · backbone=M3D · component=LGA · training-samples=1,504 · Three-way classification; M3D backbone with LGA fine-tuning; 1,504 training samples; … | Data-Efficient Fine-Tuning of Vision-Language Models for Diagnosis of Alzheimer's DiseaseSource quote\quad + LGA~\cite{hu2024lga} │ 76.7 │ 80.0 │ + 85.2M │ 1,504 |
| 6 | TabSeq SOTA frontier (+1 variant) | 75.13% | 2024-01-01 | partition=70:15:15 · feature-ordering=with; k-means, 5 clusters, ascending · target-attribute=ABETA12 · Acc.* (with feature ordering); k-means with 5 clusters, ascending order; dataset part… | TabSeq: A Framework for Deep Learning on Tabular Data via Sequential OrderingSource quoteTabSeq (ours) │ 64.44% │ 0.55 │ 75.13% │ 0.71 |
| 7 | ConnectomeDiffuser | 71.25% | 2025-01-01 | Classification performance for brain network construction methods; the cited table do… | ConnectomeDiffuser: Generative AI Enables Brain Network Construction From Diffusion Tensor ImagingSource quote\multirow{6}{*}{ADNI} │ ConnectomeDiffuser │ 71.25 │ 71.84 │ 71.25 │ 71.09 |
| 8 | QDA SOTA frontier (+1 variant) | 68% | 2012-01-01 | features=shape, PET, APOE carrier status, CSF Aβ-42 and ptau181 · weighting=η=0.8 · classifier=QDA · ADNI baseline data; analysis adds log-transformed CSF Aβ-42 and ptau181 to the preced… | Genetic, Structural and Functional Imaging Biomarkers for Early Detection of Conversion from MCI to ADSource quote29 NL, 36 AD and 59 MCI. With CSF-biomarkers, a slight increase in accuracy was observed for QDA: accuracy=68% and AUC= 0.72 (η = 0.8). |
Other primary task on ADNI: Disease Classification · ACC ↑ (%) · test (4 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | R-GenIMA (Qwen) SOTA frontier (+1 variant) | 99.01% | 2025-12-01 | labels=NC, SMC, MCI, AD · data-configuration=Mixture Dataset · paired-sample-fraction=50% · unimodal-sample-fraction=50% SNP-only · Mixture data configuration: 50% paired SNPs–MRI samples and 50% SNP-only samples. Fou… | R-GenIMA: Integrating Neuroimaging and Genetics with Interpretable Multimodal AI for Alzheimer's Disease ProgressionSource quoteR-GenIMA (Qwen) │ 99.01% │ 98.50% |
| 2 | HGGAN-proposed multimodal connectivity matrix (MC), evaluated with GCN SOTA frontier (+5 variants) | 93.02% | 2021-07-01 | classifier=GCN · train-test-split=65/35 · random-initializations=5 · ADNI data; 65% training / 35% testing split; models randomly initialized 5 times. GCN… | Characterization Multimodal Connectivity of Brain Network by Hypergraph GAN for Alzheimer's Disease AnalysisSource quote\quad │ MC(Ours) │ 93.02 │ 94.11 │ 92.30 │ 90.24 │ 82.35 │ 88.46 │ 72.00 │ 82.35 │ 50.00 |
| 3 | MediAD (‡; Monte Carlo-sampling FDA) | 90.38% | 2025-07-01 | classes=3 · Three-class CN/MCI/AD classification; internal test on ADNI. | Cross-modal Causal Intervention for Alzheimer's Disease PredictionSource quoteMediAD (\ddagger) │ 90.38 │ 90.22 │ 91.48 │ 89.05 │ 97.06 │ 75.00 │ 75.53 │ 76.07 │ 75.00 │ 88.13 |
| 4 | CvFormer with self-supervised pretraining | 89.09% | 2023-09-01 | pretraining=self-supervised · ADNI; self-supervised pretraining; 70% train, 10% validation, 20% test, repeated ten … | CvFormer: Cross-view transFormers with pre-training for fMRI analysis of human brainSource quote\checkmark │ 89.09 │ 87.35 |
Other primary task on ADNI: Alzheimer Disease Classification · AUC ↑ · test (3 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Proposed 3D Swin pretraining (L_domain + L_self + L_contrast) SOTA frontier | 0.9623 | 2024-10-01 | Task ablation; all three task groups are enabled. The cited table does not state an a… | Domain Aware Multi-Task Pretraining of 3D Swin Transformer for T1-weighted Brain MRISource quote\ding{51} │ \ding{51} │ \ding{51} │ \ 0.9462 \ │ \ 0.9623 \ |
| 2 | CITab (table's “Ours” configuration) | 0.96 | 2025-12-01 | timepoints=one per subject · pretraining=three cohorts · split_protocol=subject-wise 7:1:2 · Reported in the ablation and alternative-module table. Alzheimer’s diagnosis on the A… | Unleashing the Power of Image-Tabular Self-Supervised Learning via Breaking Cross-Tabular BarriersSource quoteOurs │ 0.846 │ 0.960 │ 0.834 │ 0.817 │ 0.895 │ 0.682 │ 0.728 │ 0.851 │ 0.651 |
| 3 | MUSE+ SOTA frontier (+1 variant) | 0.9309 | 2024-01-01 | classes=normal-control-mild-cognitive-impairment-alzheimers-disease · training-data=labeled-and-unlabeled-patients · missing-labels=50%-randomly-masked · Additional Table 7; classify visits as normal control, mild cognitive impairment, or … | Multimodal Patient Representation Learning with Missing Modalities and LabelsSource quote0.9309 modality-agnostic and label-decisive features. In contrast, the classification loss leverages modelspecific and label-decisive features to enhance prediction performance. To empirically support this, we provide additional ablation study on the supervised contrastive loss in terms of the AUC-ROC score in Tab. 7. This ablation study demonstrates the contribution of the supervised contrastive loss to the overall model performance. |
Other primary task on ADNI: Binary Classification · ACC (accuracy) ↑ (%) · test (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Ours (DTI+text) SOTA frontier | 92.94% | 2025-08-01 | modalities=DTI+clinical-text · train-test-split=80/20 · 80/20 train/test split; 301 NC and 117 MCI in the reported cohort. | Bridging Brain Connectomes and Clinical Reports for Early Alzheimer's Disease DiagnosisSource quote92.94 |
| 2 | DinoAtten3D | 87.8% | 2025-09-01 | Test set; model selected using the lowest validation loss. | DinoAtten3D: Slice-Level Attention Aggregation of DinoV2 for 3D Brain MRI Anomaly ClassificationSource quoteFor HC vs.\ AD, our model achieves 87.80% accuracy with an F_1 score of 0.871 in the test set after selecting the model with the lowest validation loss. |
Other primary task on ADNI: Diagnosis · Acc ↑ (%) · test (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Hybrid manifold learning + bagging trees (proposed) SOTA frontier | 86% | 2016-01-01 | classes=3-class · test-size=150 · training-size=2008 · Diagnosis comparison; the described holdout randomly samples 50 records per class for… | Bagging Ensembles for the Diagnosis and Prognostication of Alzheimer's DiseaseSource quote86.0 |
| 2 | CERD (Full) | 65.64% | 2026-04-01 | setting=IGCB · modalities=four · Ablation study; four-modality IGCB setting; train/validation/test split 0.7:0.15:0.15… | Conditional Evidence Reconstruction and Decomposition for Interpretable Multimodal DiagnosisSource quoteCERD (Full) │ \checkmark │ \checkmark │ × │ \checkmark │ 65.64 │ 64.06 │ 82.03 |
TaskClassification (109)Alzheimer Disease Classification (40)Binary Classification (40)Disease Classification (37)Medical Image Classification (13)Mci Conversion Prediction (12)Image Reconstruction (12)
Regimefine-tuned (26)unsupervised (12)semi-supervised (10)5-fold-cross-validation (7)5-fold-cv (6)pipeline-drift-comparison (6)
Showing 3 of 3 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2014 | HOG+SVMRank atlas selection with majority voting (MV) proposed | average surface distance error | 0.4084 mm | Brain Mri Segmentation · split: cross-validation · voting=majority-voting · anatomy=left-and-right-hippocampi · selection=HOG+SVMRank · atlas-count=23 · registration=diffeomorphic-demons | Learning-Based Atlas Selection for Multiple-Atlas SegmentationSource quoteL254: In order to demonstrate that our scoring function targeted at the ground-truth Dice ratio generalizes well to other performance measurements, we compute the average surface distance errors (in mm) by the different atlas selection methods when using K = 23 atlases to segment the left and right hippocampi. The average surface distance errors obtained by HOG+SVMRank vs NMI are 0.4084 vs. 0.4693 (MV) ; 0.3728 vs. 0.4036 (LWV) ; and 0.3608 vs. 0.3819 (NLWV), respectively. |
| 2014 | HOG+SVMRank atlas selection with local weighted voting (LWV) proposed | average surface distance error | 0.3728 mm | Brain Mri Segmentation · split: cross-validation · voting=local-weighted-voting · anatomy=left-and-right-hippocampi · selection=HOG+SVMRank · atlas-count=23 · registration=diffeomorphic-demons | Learning-Based Atlas Selection for Multiple-Atlas SegmentationSource quoteL254: In order to demonstrate that our scoring function targeted at the ground-truth Dice ratio generalizes well to other performance measurements, we compute the average surface distance errors (in mm) by the different atlas selection methods when using K = 23 atlases to segment the left and right hippocampi. The average surface distance errors obtained by HOG+SVMRank vs NMI are 0.4084 vs. 0.4693 (MV) ; 0.3728 vs. 0.4036 (LWV) ; and 0.3608 vs. 0.3819 (NLWV), respectively. |
| 2014 | HOG+SVMRank atlas selection with non-local weighted voting (NLWV) proposed | average surface distance error | 0.3608 mm | Brain Mri Segmentation · split: cross-validation · voting=non-local-weighted-voting · anatomy=left-and-right-hippocampi · selection=HOG+SVMRank · atlas-count=23 · registration=diffeomorphic-demons | Learning-Based Atlas Selection for Multiple-Atlas SegmentationSource quoteL254: In order to demonstrate that our scoring function targeted at the ground-truth Dice ratio generalizes well to other performance measurements, we compute the average surface distance errors (in mm) by the different atlas selection methods when using K = 23 atlases to segment the left and right hippocampi. The average surface distance errors obtained by HOG+SVMRank vs NMI are 0.4084 vs. 0.4693 (MV) ; 0.3728 vs. 0.4036 (LWV) ; and 0.3608 vs. 0.3819 (NLWV), respectively. |