ADNI

202 papers · 607 extracted observations · classification · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Classification.

46.963.580.196.7201220192026QDA: 66.14 (2012)QDA: 68.0 (2012)TabSeq: 64.44 (2024)TabSeq: 75.13 (2024)GLIM-Net: 77.9 (2024)MST-former (3 scales): 90.3 (2024)ConnectomeDiffuser: 71.25 (2025)MedOrch: 50.35 (2025)MedOrch (o1-mini, best@5): 93.26 (2025)M3D + LGA: 76.7 (2025)RCL: 89.3 (2025)Reinforced Domain Selection: 90.5 (2025)Artemis: 84.3 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 15 of 15 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026ACADiff proposedMAE0.014Image Generation · aggregation=average across three generators · evaluation-region=brain-maskAdaptive Clinical-Aware Latent Diffusion for Multimodal Brain Image Generation and Missing Modality Imputation
Source quote
L169: \header{Results} Fig.~\ref{fig:gen} shows generation performance. ACADiff consistently outperforms all baselines across all metrics (PSNR 27.9, SSIM 0.911, NMI 0.859, MAE 0.014), exceeding the best baseline LDM. The gap between ACADiff and ACADiff-emb (\sim1.8 PSNR) validates the benefit of semantic clinical encoding via GPT-4o. Table~\ref{tab:vol_classification} presents AD vs. HC classification under varying missing rates. ACADiff maintains robust performance across all scenarios, achieving 89.4% accuracy with 20% missing data (97.2% of oracle using complete real data). The advantage becomes more pronounced under extreme conditions: at 80% missing data, ACADiff preserves 77.5% accuracy while simple imputation fails. Among baselines, LDM performs best (76.4%) but remains below our approach. The consistent superiority over ACADiff-emb confirms that language model encoding provides meaningful clinical guidance. These results validate the clinical utility of our framework for multimodal brain image completion.
2025OPTIMUS, multiple modalities + KNNImputer + TabNetRegressor default proposedMean absolute error (MAE)0.543Cognitive Score Prediction · split: test · model=TabNetRegressor default · imputation=KNNImputer · modalities=multiple · test_samples=12OPTIMUS: Predicting Multivariate Outcomes in Alzheimer's Disease Using Multi-Modal Data Amidst Missing Values
Source quote
L721: Multiple │ KNNImputer │ TabNetRegressor default │ 0.487 │ 0.685 │ 0.615 │ 0.383 │ 0.543 │ 0.134
2025OPTIMUS, multiple modalities + KNNImputer + TabNetRegressor custom proposedMean absolute error (MAE)0.671Cognitive Score Prediction · split: test · model=TabNetRegressor custom · evaluation=leave-one-missing-out cross-validation · imputation=KNNImputer · modalities=multiple · test_samples=20OPTIMUS: Predicting Multivariate Outcomes in Alzheimer's Disease Using Multi-Modal Data Amidst Missing Values
Source quote
L979: Multiple │ KNNImputer │ TabNetRegressor custom │ 0.823 │ 0.619 │ 0.612 │ 0.629 │ 0.671 │ 0.102
2025GAN-Finetuned proposedParietal Lobe volume MAE0.282Counterfactual Generation · intervention=do(fro)Evaluation of 3D Counterfactual Brain MRI Generation
Source quote
L193: GAN-Finetuned │ 0.282 │ 0.084 │ 0.493 │ 0.671 │ 0.731 │ 0.515
2025GAN-Finetuned proposedTemporal Lobe volume MAE0.217Counterfactual Generation · intervention=do(fro)Evaluation of 3D Counterfactual Brain MRI Generation
Source quote
L208: GAN-Finetuned │ 0.217 │ 0.114 │ 0.399 │ 0.540 │ 0.588 │ 0.415
2025GAN-Finetuned proposedOccipital Lobe volume MAE1.434Counterfactual Generation · intervention=do(fro)Evaluation of 3D Counterfactual Brain MRI Generation
Source quote
L223: GAN-Finetuned │ 1.434 │ 0.617 │ 0.723 │ 0.438 │ 0.556 │ 0.270
2025GAN-Finetuned proposedCingulate cortex volume MAE3.760Counterfactual Generation · intervention=do(fro)Evaluation of 3D Counterfactual Brain MRI Generation
Source quote
L238: GAN-Finetuned │ 3.760 │ 2.079 │ 2.297 │ 0.632 │ 0.331 │ 0.610
2025GAN-Finetuned proposedInsula volume MAE6.075Counterfactual Generation · intervention=do(fro)Evaluation of 3D Counterfactual Brain MRI Generation
Source quote
L253: GAN-Finetuned │ 6.075 │ 3.550 │ 3.878 │ 1.378 │ 0.294 │ 1.264
2025GAN-Finetuned proposedVentricle volume MAE0.702Counterfactual Generation · intervention=do(fro)Evaluation of 3D Counterfactual Brain MRI Generation
Source quote
L268: GAN-Finetuned │ 0.702 │ 0.340 │ 0.384 │ 0.109 │ 0.147 │ 0.196
2024SOE, self-supervised pretrained on ADNI (self-training) proposedMAE5.88Age Regression · pretraining-dataset=ADNISOE: SO(3)-Equivariant 3D MRI Encoding
Source quote
L88: First, we evaluated our proposed method with regard to its generalizability across datasets. We examined the classification and age regression performance on ADNI of models without pretraining, pretrained with SOE on the NCANDA dataset, and pretrained with SOE on the ADNI dataset. In Table \ref{NCANDA_pretraining}, we observe that our proposed SOE pretraining performs better than the no pretraining instance for both ADNI NC vs. AD classification and age prediction tasks by 0.5-8% in terms of BACC. Furthermore, we observe that pretraining our model on the same dataset (ADNI) as the downstream task evaluation, the so-called ``self-training", outperforms the model pretrained on NCANDA in classification (AUC 91.3 vs. 91.1; BACC 83.84 vs. 82.81; F1 79.38 vs. 78.50). Particularly when evaluated on the task of age prediction, our representation learning framework outperforms the model with no pretraining (R2 0.45 vs. 0.41; MAE 5.88 vs. 5.95).
2023BDHT proposedMAE0.0092Time Series Reconstruction · split: val · input=ROI-based time series · evaluation=5-fold cross-validationBDHT: Generative AI Enables Causality Analysis for Mild Cognitive Impairment
Source quote
L227: The output of the proposed model is the denoised time series and the effective connectivity. We evaluated the performance of the generated time series. The details of generating one ROI-based time series by our model are displayed in Fig.~\ref{fig4}. As the time steps decrease, the Gaussian noise is gradually transformed into a clean time series. We select two other generative frameworks for comparison, including the variational autoencoder (VAE) and the generative adversarial network (GAN). These two frameworks accept both SC and rough time series by designing graph convolutional networks (GCN). As shown in Fig.~\ref{fig5}, the VAE-based or GAN-based models have larger reconstructed errors, while our model achieves the minimum mean value for MAE and RMSE with 0.0092 and 0.0121, respectively. The standard error of our model is also lower than that of the other two models.
2023Weighted Siamese proposedMAE2.00Ordinal RegressionInterpretable Weighted Siamese Network to Predict the Time to Onset of Alzheimer's Disease from MRI Images
Source quote
L121: Weighted Siamese │ 2.00 │ 2.40
2019sGP(VIS) proposedmean absolute error (MAE)0.32Forecasting · split: val · fine-tuned · visit-filter=existing visits only · cross-validation=10-fold subject-independent · forecast-horizon=6, 12, 18, and 24 months · metric-aggregation=averaged across four forecasting stepsMeta-Weighted Gaussian Process Experts for Personalized Forecasting of AD Cognitive Changes
Source quote
L168: Table 1 compares the evaluation metrics for the model settings described above. By comparing different population-level GP models, we note that simple smoothing of the previous ADAS-Cog13 score (y_t) using sGP(VIS) is quite effective. We attribute this to the fact that the target scores from the consequent visits are highly correlated. Compared to the model free approach, Base (y_t), which forecasts by "carrying forward" the current score, we note that sGP(VIS) takes advantage of the GP's smoothing property, effectively leveraging the labels (i.e. ADAS-Cog13 scores) from the training population. This results in average error reduction of 0.32 over the four time steps.
2019LSTM-Robust proposedMAE0.00307Longitudinal Prediction · split: test · biomarker=ventricles · prediction-interval=yearlyTraining recurrent neural networks robust to incomplete data: application to Alzheimer's disease progression modeling
Source quote
L209: Ventricles │ 0.00307^{\star\star\star/\star\star\star/\star\star\star} │ 0.00620 │ 0.00472 │ 0.00807
2019LSTM-Robust proposedMAE0.01330Longitudinal Prediction · split: test · biomarker=whole-brain · prediction-interval=yearlyTraining recurrent neural networks robust to incomplete data: application to Alzheimer's disease progression modeling
Source quote
L211: Whole brain │ 0.01330^{\star\star\star/\star\star/\star\star\star} │ 0.02375 │ 0.01639 │ 0.00551