ADNI
202 papers · 607 extracted observations · classification · Markdown · CSV · JSON API
Tasks on ADNIAll tasks (202)Classification (44)Alzheimer Disease Classification (13)Binary Classification (13)Disease Classification (13)Image Classification (5)Medical Image Classification (5)Image Generation (4)Image Reconstruction (4)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Proposed/measured results matching task=Classification.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | MedOrch (o1-mini, best@5) SOTA frontier (+1 variant) | 93.26% | 2025-06-01 | Three-class AD vs. MCI vs. NC diagnosis; best@5 counts a case correct if any of five … | MedOrch: Medical Diagnosis with Tool-Augmented Reasoning Agents for Flexible ExtensibilitySource quoteDiagnostic Performance. On the three-class AD vs. MCI vs. NC classification task, \texttt{MedOrch}\xspace with o1-mini using the best@5 strategy achieves the highest accuracy of 93.26%, outperforming all baseline methods, including the previous state-of-the-art ConvNext+GPT approach (89.05%). This represents a 4.21% absolute improvement in accuracy. Similar patterns are observed in the four-class classification tasks (AD vs. EMCI vs. LMCI vs. NC), where \texttt{MedOrch}\xspace consistently outperforms baselines across all metrics. The significant improvement highlights the value of \texttt{MedOrch}\xspace' dynamic tool-calling approach, which can adapt its information-gathering strategy to each specific case. |
| 2 | Reinforced Domain Selection (+1 variant) | 90.5% | 2025-10-01 | CDA comparison with four intermediate domains; ADNI classification across five diseas… | Reinforced Domain Selection for Continuous Domain AdaptationSource quoteOurs │ 93.4 │ 90.5 |
| 3 | MST-former (3 scales) SOTA frontier (+1 variant) | 90.3% | 2024-02-01 | resolution=256x256 · Next-status prediction among NC, MCI, and AD from clips of 3 MRI scans (256×256×256). | Multi-Scale Spatio-Temporal Transformer-Based Imbalanced Longitudinal Learning for Glaucoma Forecasting From Irregular Time Series ImagesSource quoteOurs │ 0.966 │ 90.3 │ 87.0 │ 94.2 |
| 4 | Artemis | 84.3% | 2026-06-01 | classes=NC vs. MCI · ADNI benchmark task: NC vs. MCI; reported score. | Artemis: Anatomy-Resolved inTervention for Eliminating Multimodal NeuroImage confounderSSource quoteOn ADNI, Artemis achieves 84.3% accuracy, a +5.0% absolute improvement over the best baseline BrainNetCNN (79.3%), and a macro-F1 of 73.5% compared with BrainNetCNN's 52.4%, a +21.1 percentage-point gain that reflects far more balanced recall across the NC and MCI classes. |
| 5 | M3D + LGA | 76.7% | 2025-09-01 | runs=5 · backbone=M3D · component=LGA · training-samples=1,504 · Three-way classification; M3D backbone with LGA fine-tuning; 1,504 training samples; … | Data-Efficient Fine-Tuning of Vision-Language Models for Diagnosis of Alzheimer's DiseaseSource quote\quad + LGA~\cite{hu2024lga} │ 76.7 │ 80.0 │ + 85.2M │ 1,504 |
| 6 | TabSeq SOTA frontier (+1 variant) | 75.13% | 2024-01-01 | partition=70:15:15 · feature-ordering=with; k-means, 5 clusters, ascending · target-attribute=ABETA12 · Acc.* (with feature ordering); k-means with 5 clusters, ascending order; dataset part… | TabSeq: A Framework for Deep Learning on Tabular Data via Sequential OrderingSource quoteTabSeq (ours) │ 64.44% │ 0.55 │ 75.13% │ 0.71 |
| 7 | ConnectomeDiffuser | 71.25% | 2025-01-01 | Classification performance for brain network construction methods; the cited table do… | ConnectomeDiffuser: Generative AI Enables Brain Network Construction From Diffusion Tensor ImagingSource quote\multirow{6}{*}{ADNI} │ ConnectomeDiffuser │ 71.25 │ 71.84 │ 71.25 │ 71.09 |
| 8 | QDA SOTA frontier (+1 variant) | 68% | 2012-01-01 | features=shape, PET, APOE carrier status, CSF Aβ-42 and ptau181 · weighting=η=0.8 · classifier=QDA · ADNI baseline data; analysis adds log-transformed CSF Aβ-42 and ptau181 to the preced… | Genetic, Structural and Functional Imaging Biomarkers for Early Detection of Conversion from MCI to ADSource quote29 NL, 36 AD and 59 MCI. With CSF-biomarkers, a slight increase in accuracy was observed for QDA: accuracy=68% and AUC= 0.72 (η = 0.8). |
Other primary task on ADNI: Disease Classification · ACC ↑ (%) · test (4 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | R-GenIMA (Qwen) SOTA frontier (+1 variant) | 99.01% | 2025-12-01 | labels=NC, SMC, MCI, AD · data-configuration=Mixture Dataset · paired-sample-fraction=50% · unimodal-sample-fraction=50% SNP-only · Mixture data configuration: 50% paired SNPs–MRI samples and 50% SNP-only samples. Fou… | R-GenIMA: Integrating Neuroimaging and Genetics with Interpretable Multimodal AI for Alzheimer's Disease ProgressionSource quoteR-GenIMA (Qwen) │ 99.01% │ 98.50% |
| 2 | HGGAN-proposed multimodal connectivity matrix (MC), evaluated with GCN SOTA frontier (+5 variants) | 93.02% | 2021-07-01 | classifier=GCN · train-test-split=65/35 · random-initializations=5 · ADNI data; 65% training / 35% testing split; models randomly initialized 5 times. GCN… | Characterization Multimodal Connectivity of Brain Network by Hypergraph GAN for Alzheimer's Disease AnalysisSource quote\quad │ MC(Ours) │ 93.02 │ 94.11 │ 92.30 │ 90.24 │ 82.35 │ 88.46 │ 72.00 │ 82.35 │ 50.00 |
| 3 | MediAD (‡; Monte Carlo-sampling FDA) | 90.38% | 2025-07-01 | classes=3 · Three-class CN/MCI/AD classification; internal test on ADNI. | Cross-modal Causal Intervention for Alzheimer's Disease PredictionSource quoteMediAD (\ddagger) │ 90.38 │ 90.22 │ 91.48 │ 89.05 │ 97.06 │ 75.00 │ 75.53 │ 76.07 │ 75.00 │ 88.13 |
| 4 | CvFormer with self-supervised pretraining | 89.09% | 2023-09-01 | pretraining=self-supervised · ADNI; self-supervised pretraining; 70% train, 10% validation, 20% test, repeated ten … | CvFormer: Cross-view transFormers with pre-training for fMRI analysis of human brainSource quote\checkmark │ 89.09 │ 87.35 |
Other primary task on ADNI: Alzheimer Disease Classification · AUC ↑ · test (3 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Proposed 3D Swin pretraining (L_domain + L_self + L_contrast) SOTA frontier | 0.9623 | 2024-10-01 | Task ablation; all three task groups are enabled. The cited table does not state an a… | Domain Aware Multi-Task Pretraining of 3D Swin Transformer for T1-weighted Brain MRISource quote\ding{51} │ \ding{51} │ \ding{51} │ \ 0.9462 \ │ \ 0.9623 \ |
| 2 | CITab (table's “Ours” configuration) | 0.96 | 2025-12-01 | timepoints=one per subject · pretraining=three cohorts · split_protocol=subject-wise 7:1:2 · Reported in the ablation and alternative-module table. Alzheimer’s diagnosis on the A… | Unleashing the Power of Image-Tabular Self-Supervised Learning via Breaking Cross-Tabular BarriersSource quoteOurs │ 0.846 │ 0.960 │ 0.834 │ 0.817 │ 0.895 │ 0.682 │ 0.728 │ 0.851 │ 0.651 |
| 3 | MUSE+ SOTA frontier (+1 variant) | 0.9309 | 2024-01-01 | classes=normal-control-mild-cognitive-impairment-alzheimers-disease · training-data=labeled-and-unlabeled-patients · missing-labels=50%-randomly-masked · Additional Table 7; classify visits as normal control, mild cognitive impairment, or … | Multimodal Patient Representation Learning with Missing Modalities and LabelsSource quote0.9309 modality-agnostic and label-decisive features. In contrast, the classification loss leverages modelspecific and label-decisive features to enhance prediction performance. To empirically support this, we provide additional ablation study on the supervised contrastive loss in terms of the AUC-ROC score in Tab. 7. This ablation study demonstrates the contribution of the supervised contrastive loss to the overall model performance. |
Other primary task on ADNI: Binary Classification · ACC (accuracy) ↑ (%) · test (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Ours (DTI+text) SOTA frontier | 92.94% | 2025-08-01 | modalities=DTI+clinical-text · train-test-split=80/20 · 80/20 train/test split; 301 NC and 117 MCI in the reported cohort. | Bridging Brain Connectomes and Clinical Reports for Early Alzheimer's Disease DiagnosisSource quote92.94 |
| 2 | DinoAtten3D | 87.8% | 2025-09-01 | Test set; model selected using the lowest validation loss. | DinoAtten3D: Slice-Level Attention Aggregation of DinoV2 for 3D Brain MRI Anomaly ClassificationSource quoteFor HC vs.\ AD, our model achieves 87.80% accuracy with an F_1 score of 0.871 in the test set after selecting the model with the lowest validation loss. |
Other primary task on ADNI: Diagnosis · Acc ↑ (%) · test (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Hybrid manifold learning + bagging trees (proposed) SOTA frontier | 86% | 2016-01-01 | classes=3-class · test-size=150 · training-size=2008 · Diagnosis comparison; the described holdout randomly samples 50 records per class for… | Bagging Ensembles for the Diagnosis and Prognostication of Alzheimer's DiseaseSource quote86.0 |
| 2 | CERD (Full) | 65.64% | 2026-04-01 | setting=IGCB · modalities=four · Ablation study; four-modality IGCB setting; train/validation/test split 0.7:0.15:0.15… | Conditional Evidence Reconstruction and Decomposition for Interpretable Multimodal DiagnosisSource quoteCERD (Full) │ \checkmark │ \checkmark │ × │ \checkmark │ 65.64 │ 64.06 │ 82.03 |
TaskClassification (109)Alzheimer Disease Classification (40)Binary Classification (40)Disease Classification (37)Medical Image Classification (13)Mci Conversion Prediction (12)Image Reconstruction (12)
Regimefine-tuned (26)unsupervised (12)semi-supervised (10)5-fold-cross-validation (7)5-fold-cv (6)pipeline-drift-comparison (6)
Showing 27 of 27 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Scientific Claim Stability (SCS) proposed non-standard slice | Transfer AUROC | 0.704 | Classification · pipeline-drift-comparison | A Scientific Claim Stability Framework for Evaluating MRI Morphometry PipelinesSource quoteL764: AUROC 0.704; |
| 2026 | Scientific Claim Stability (SCS) proposed | Transfer AUROC | 0.561 | Classification · pipeline-drift-comparison | A Scientific Claim Stability Framework for Evaluating MRI Morphometry PipelinesSource quoteL774: AUROC 0.561; |
| 2026 | Schema-Adaptive model proposed | AUROC (Avg-All; macro-average over 13 diagnostic labels) | 0.727 | Clinical Diagnosis · 0-shot · schema=unseen · training_data=NACC | Schema-Adaptive Tabular Representation Learning with LLMs for Generalizable Multimodal Clinical ReasoningSource quoteL220: As summarized in Table~\ref{tab:zero_shot}, both non-LLM baselines collapse when evaluated on the unseen ADNI schema, with performance barely above random, confirming their brittleness to schema shifts. In contrast, our schema-adaptive model achieves an average AUROC of 0.727, a substantial margin demonstrating its capacity to align heterogeneous feature semantics. For instance, the model successfully maps ``MMSE Total Score'' from NACC and ``MMSCORE'' from ADNI into a coherent semantic embedding. This finding provides strong empirical evidence that linguistic tokenization allows the model to perform cross-schema translation, enabling zero-shot reasoning across disparate tabular structures—a core capability long considered unattainable for standard tabular models. |
| 2026 | NACC-FewShot (fine-tuned schema-grounded model) proposed | AUROC | 0.9362 | Clinical Diagnosis · few-shot · model=schema-grounded · training_samples=300 | Schema-Adaptive Tabular Representation Learning with LLMs for Generalizable Multimodal Clinical ReasoningSource quoteL256: 300 │ 0.9362 │ 0.7206 |
| 2026 | MM-KG (condition D; Qwen3.5-9B) proposed | AUROC | .86 | Classification · split: test · params=9B | Aligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMsSource quoteL585: 0.786 (.86) |
| 2026 | ADNI-Train (trained from scratch) baseline | AUROC | 0.7206 | Clinical Diagnosis · few-shot · training=from-scratch · training_samples=300 | Schema-Adaptive Tabular Representation Learning with LLMs for Generalizable Multimodal Clinical ReasoningSource quoteL256: 300 │ 0.9362 │ 0.7206 |
| 2025 | Adaptive two-stage framework (Triage Model) proposed | test AUROC | 0.929 | Alzheimer Disease Progression Prediction · split: test | An Adaptive Machine Learning Triage Framework for Predicting Alzheimer's Disease ProgressionSource quoteL4: Accurate predictions of conversion from mild cognitive impairment (MCI) to Alzheimer's disease (AD) can enable effective personalized therapy. While cognitive tests and clinical data are routinely collected, they lack the predictive power of PET scans and CSF biomarker analysis, which are prohibitively expensive to obtain for every patient. To address this cost-accuracy dilemma, we design a two-stage machine learning framework that selectively obtains advanced, costly features based on their predicted ``value of information''. We apply our framework to predict AD progression for MCI patients using data from the Alzheimer's Disease Neuroimaging Initiative (ADNI). Our framework reduces the need for advanced testing by 20% while achieving a test AUROC of 0.929, comparable to the model that uses both basic and advanced features (AUROC=0.915, p=0.1010). We also provide an example interpretability analysis showing how one may explain the triage decision. Our work presents an interpretable, data-driven framework that optimizes AD diagnostic pathways and balances accuracy with cost, representing a step towards making early, reliable AD prediction more accessible in real-world practice. Future work should consider multiple categories of advanced features and larger-scale validation. |
| 2025 | BrainFound proposed | AUROC | 0.830 | Disease Classification · diagnosis=AD classification · train-cohort=NACC | Towards Generalisable Foundation Models for 3D Brain MRISource quoteL167: To assess external validity, we conducted six cross-cohort evaluations where models trained on one dataset were tested on independent cohorts for Alzheimer’s disease (AD) classification. When trained on the NACC dataset, BrainFound achieved the highest AUROC in all target cohorts: 0.830 on ADNI, 0.880 on OASIS, and 0.799 on AIBL, outperforming all baselines (Figure \ref{fig:fig6}). |
| 2025 | Autoencoder KL proposed | AUROC | 0.69 | Image Classification · split: test | Resolution Invariant AutoencoderSource quoteL98: HR Testing │ \multicolumn{1}{c|}{0.78} │ \multicolumn{1}{c|}{0.69} │ 0.67 │ \multicolumn{1}{c|}{0.78} │ \multicolumn{1}{c|}{0.74} │ 0.77 |
| 2025 | AE-KL Invariant (Resolution Invariant AE) proposed | AUROC | 0.74 | Image Classification · split: test | Resolution Invariant AutoencoderSource quoteL98: HR Testing │ \multicolumn{1}{c|}{0.78} │ \multicolumn{1}{c|}{0.69} │ 0.67 │ \multicolumn{1}{c|}{0.78} │ \multicolumn{1}{c|}{0.74} │ 0.77 |
| 2025 | Model using both basic and advanced features (Advanced Model) baseline | test AUROC | 0.915 | Alzheimer Disease Progression Prediction · split: test | An Adaptive Machine Learning Triage Framework for Predicting Alzheimer's Disease ProgressionSource quoteL4: Accurate predictions of conversion from mild cognitive impairment (MCI) to Alzheimer's disease (AD) can enable effective personalized therapy. While cognitive tests and clinical data are routinely collected, they lack the predictive power of PET scans and CSF biomarker analysis, which are prohibitively expensive to obtain for every patient. To address this cost-accuracy dilemma, we design a two-stage machine learning framework that selectively obtains advanced, costly features based on their predicted ``value of information''. We apply our framework to predict AD progression for MCI patients using data from the Alzheimer's Disease Neuroimaging Initiative (ADNI). Our framework reduces the need for advanced testing by 20% while achieving a test AUROC of 0.929, comparable to the model that uses both basic and advanced features (AUROC=0.915, p=0.1010). We also provide an example interpretability analysis showing how one may explain the triage decision. Our work presents an interpretable, data-driven framework that optimizes AD diagnostic pathways and balances accuracy with cost, representing a step towards making early, reliable AD prediction more accessible in real-world practice. Future work should consider multiple categories of advanced features and larger-scale validation. |
| 2024 | MORPHADE (unsupervised) proposed | AUROC | 0.80 | Classification · split: test · method=unsupervised · training=760 healthy controls | Unsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable AutoencodersSource quoteL96: In this section, we assess the capability of MORPHADE in detecting AD at the patient level. Table \ref{tab::benchmark_anomaly_detection} shows the Area Under the Receiver Operating Characteristic curve (AUROC) scores obtained when comparing our method to various baselines for identifying subjects with AD compared to healthy control (HC) subjects. Our model achieves an AUROC of 0.80, surpassing even the 3D supervised baselines ResNet \cite{supervised_resnet} and DenseNet \cite{supervised_densenet}, with AUROCs of 0.77 and 0.74, respectively. |
| 2024 | LR (logistic regression) baseline | Average test AUROC | 56.2% | Clinical Prediction · split: test · model=logistic-regression · history=current-context-only · evaluation=average-across-five-splits · aggregation=sum | How Should We Represent History in Interpretable Models of Clinical Policies?Source quoteL550: \multirow[c]{8}{*}{ADNI} │ X_t │ \begin{tabular}[c]{@{}c@{}}54.2\\(51.4, 57.0) │ \begin{tabular}[c]{@{}c@{}}56.2\\(54.4, 57.4) │ \begin{tabular}[c]{@{}c@{}}53.9\\(52.1, 55.9) │ \begin{tabular}[c]{@{}c@{}}55.6\\(54.1, 57.0) |
| 2024 | LR (logistic regression) baseline | Average test AUROC | 64.4% | Clinical Prediction · split: test · model=logistic-regression · history=aggregated-history · evaluation=average-across-five-splits · aggregation=sum | How Should We Represent History in Interpretable Models of Clinical Policies?Source quoteL553: \bar{H}_t │ \begin{tabular}[c]{@{}c@{}}63.0\\(61.3, 64.7) │ \begin{tabular}[c]{@{}c@{}}64.4\\(62.8, 65.9) │ \begin{tabular}[c]{@{}c@{}}64.9\\(63.1, 66.7) │ \begin{tabular}[c]{@{}c@{}}64.1\\(62.2, 65.3) |
| 2024 | ResNet (3D supervised baseline) baseline | AUROC | 0.77 | Classification · split: test · backbone=3D ResNet · training=includes 430 AD samples | Unsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable AutoencodersSource quoteL96: In this section, we assess the capability of MORPHADE in detecting AD at the patient level. Table \ref{tab::benchmark_anomaly_detection} shows the Area Under the Receiver Operating Characteristic curve (AUROC) scores obtained when comparing our method to various baselines for identifying subjects with AD compared to healthy control (HC) subjects. Our model achieves an AUROC of 0.80, surpassing even the 3D supervised baselines ResNet \cite{supervised_resnet} and DenseNet \cite{supervised_densenet}, with AUROCs of 0.77 and 0.74, respectively. |
| 2024 | DenseNet (3D supervised baseline) baseline | AUROC | 0.74 | Classification · split: test · backbone=3D DenseNet · training=includes 430 AD samples | Unsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable AutoencodersSource quoteL96: In this section, we assess the capability of MORPHADE in detecting AD at the patient level. Table \ref{tab::benchmark_anomaly_detection} shows the Area Under the Receiver Operating Characteristic curve (AUROC) scores obtained when comparing our method to various baselines for identifying subjects with AD compared to healthy control (HC) subjects. Our model achieves an AUROC of 0.80, surpassing even the 3D supervised baselines ResNet \cite{supervised_resnet} and DenseNet \cite{supervised_densenet}, with AUROCs of 0.77 and 0.74, respectively. |
| 2024 | Brainomaly baseline | AUROC | 0.78 | Classification · split: test · method=anomaly detection · training=requires pathological samples | Unsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable AutoencodersSource quoteL98: Furthermore, we obtain improved performance compared to methods proposed for unsupervised anomaly detection. These methods are only available in 2D, so were assessed slice-wise with the final anomaly scores obtained by averaging over the slices for each patient. f-AnoGAN \cite{fanogan}, Ganomaly \cite{ganomaly} obtained AUROCs of 0.70 and 0.72, respectively. We also outperform Brainomaly~\cite{brainomaly} (AUROC 0.78), a method that is not strictly unsupervised since it requires pathological samples during training for improved performance. |
| 2024 | f-AnoGAN baseline | AUROC | 0.70 | Classification · split: test · input=2D slices · scoring=mean over slices | Unsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable AutoencodersSource quoteL98: Furthermore, we obtain improved performance compared to methods proposed for unsupervised anomaly detection. These methods are only available in 2D, so were assessed slice-wise with the final anomaly scores obtained by averaging over the slices for each patient. f-AnoGAN \cite{fanogan}, Ganomaly \cite{ganomaly} obtained AUROCs of 0.70 and 0.72, respectively. We also outperform Brainomaly~\cite{brainomaly} (AUROC 0.78), a method that is not strictly unsupervised since it requires pathological samples during training for improved performance. |
| 2024 | Ganomaly baseline | AUROC | 0.72 | Classification · split: test · input=2D slices · scoring=mean over slices | Unsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable AutoencodersSource quoteL98: Furthermore, we obtain improved performance compared to methods proposed for unsupervised anomaly detection. These methods are only available in 2D, so were assessed slice-wise with the final anomaly scores obtained by averaging over the slices for each patient. f-AnoGAN \cite{fanogan}, Ganomaly \cite{ganomaly} obtained AUROCs of 0.70 and 0.72, respectively. We also outperform Brainomaly~\cite{brainomaly} (AUROC 0.78), a method that is not strictly unsupervised since it requires pathological samples during training for improved performance. |
| 2023 | CPR proposed | AUROC | 0.763 | Mri Order Prediction · static-context=patient age and gender | Contextualized Policy Recovery: Modeling and Interpreting Medical Decisions with Adaptive Imitation LearningSource quoteL283: Additionally, static contexts substantially increase the action-matching performance of CPR to 0.763 AUROC. |
| 2018 | MATCH-Net without clinician input ablation | AUROC | 0.962 | Survival Analysis · split: val · evaluation=five-fold cross-validation · clinician-input=none · prediction-horizon=0.5 years | MATCH-Net: Dynamic Prediction in Survival Analysis using Convolutional Neural NetworksSource quoteL61: {} │ {\tau} │ {Match-Net} │ {S-TCN} │ {S-MLP} │ {FCN} │ {D-Atlas} │ {RNN} │ {MLP} │ {JM} │ {LM} auroc │ 0.5 │ 0.962~ │ 0.961~ │ 0.959~ │ 0.954~ │ 0.959~ │ 0.949* │ 0.948* │ 0.913* │ 0.909* |
| 2018 | MATCH-Net without clinician input ablation | AUROC | 0.942 | Survival Analysis · split: val · evaluation=five-fold cross-validation · clinician-input=none · prediction-horizon=1.0 years | MATCH-Net: Dynamic Prediction in Survival Analysis using Convolutional Neural NetworksSource quoteL62: 1.0 │ 0.942~ │ 0.941~ │ 0.932~ │ 0.930~ │ 0.929~ │ 0.930~ │ 0.930~ │ 0.917* │ 0.914* |
| 2018 | S-TCN baseline | AUROC | 0.961 | Survival Analysis · split: val · evaluation=five-fold cross-validation · prediction-horizon=0.5 years | MATCH-Net: Dynamic Prediction in Survival Analysis using Convolutional Neural NetworksSource quoteL61: {} │ {\tau} │ {Match-Net} │ {S-TCN} │ {S-MLP} │ {FCN} │ {D-Atlas} │ {RNN} │ {MLP} │ {JM} │ {LM} auroc │ 0.5 │ 0.962~ │ 0.961~ │ 0.959~ │ 0.954~ │ 0.959~ │ 0.949* │ 0.948* │ 0.913* │ 0.909* |
| 2018 | S-TCN baseline | AUROC | 0.941 | Survival Analysis · split: val · evaluation=five-fold cross-validation · prediction-horizon=1.0 years | MATCH-Net: Dynamic Prediction in Survival Analysis using Convolutional Neural NetworksSource quoteL62: 1.0 │ 0.942~ │ 0.941~ │ 0.932~ │ 0.930~ │ 0.929~ │ 0.930~ │ 0.930~ │ 0.917* │ 0.914* |
| 2017 | Deep CNN (ConvScore; FDG and AV-45 PET) proposed | ROC AUC | 0.89 | Mci Conversion Prediction · cohort=171 MCI participants · modality=FDG and AV-45 PET | Predicting Cognitive Decline with Deep Learning of Brain Metabolism and Amyloid ImagingSource quoteL267: 0.89 |
| 2017 | Feature VOI-based (FDG) baseline | ROC AUC | 0.82 | Mci Conversion Prediction · cohort=171 MCI participants · method=feature VOI · modality=FDG PET | Predicting Cognitive Decline with Deep Learning of Brain Metabolism and Amyloid ImagingSource quoteL264: 0.82 |
| 2017 | Feature VOI-based (AV45) baseline | ROC AUC | 0.83 | Mci Conversion Prediction · cohort=171 MCI participants · method=feature VOI · modality=AV-45 PET | Predicting Cognitive Decline with Deep Learning of Brain Metabolism and Amyloid ImagingSource quoteL265: 0.83 |