ADNI

202 papers · 607 extracted observations · classification · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Classification.

46.963.580.196.7201220192026QDA: 66.14 (2012)QDA: 68.0 (2012)TabSeq: 64.44 (2024)TabSeq: 75.13 (2024)GLIM-Net: 77.9 (2024)MST-former (3 scales): 90.3 (2024)ConnectomeDiffuser: 71.25 (2025)MedOrch: 50.35 (2025)MedOrch (o1-mini, best@5): 93.26 (2025)M3D + LGA: 76.7 (2025)RCL: 89.3 (2025)Reinforced Domain Selection: 90.5 (2025)Artemis: 84.3 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 27 of 27 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Scientific Claim Stability (SCS) proposed non-standard sliceTransfer AUROC0.704Classification · pipeline-drift-comparisonA Scientific Claim Stability Framework for Evaluating MRI Morphometry Pipelines
Source quote
L764: AUROC 0.704;
2026Scientific Claim Stability (SCS) proposedTransfer AUROC0.561Classification · pipeline-drift-comparisonA Scientific Claim Stability Framework for Evaluating MRI Morphometry Pipelines
Source quote
L774: AUROC 0.561;
2026Schema-Adaptive model proposedAUROC (Avg-All; macro-average over 13 diagnostic labels)0.727Clinical Diagnosis · 0-shot · schema=unseen · training_data=NACCSchema-Adaptive Tabular Representation Learning with LLMs for Generalizable Multimodal Clinical Reasoning
Source quote
L220: As summarized in Table~\ref{tab:zero_shot}, both non-LLM baselines collapse when evaluated on the unseen ADNI schema, with performance barely above random, confirming their brittleness to schema shifts. In contrast, our schema-adaptive model achieves an average AUROC of 0.727, a substantial margin demonstrating its capacity to align heterogeneous feature semantics. For instance, the model successfully maps ``MMSE Total Score'' from NACC and ``MMSCORE'' from ADNI into a coherent semantic embedding. This finding provides strong empirical evidence that linguistic tokenization allows the model to perform cross-schema translation, enabling zero-shot reasoning across disparate tabular structures—a core capability long considered unattainable for standard tabular models.
2026NACC-FewShot (fine-tuned schema-grounded model) proposedAUROC0.9362Clinical Diagnosis · few-shot · model=schema-grounded · training_samples=300Schema-Adaptive Tabular Representation Learning with LLMs for Generalizable Multimodal Clinical Reasoning
Source quote
L256: 300 │ 0.9362 │ 0.7206
2026MM-KG (condition D; Qwen3.5-9B) proposedAUROC.86Classification · split: test · params=9BAligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMs
Source quote
L585: 0.786 (.86)
2026ADNI-Train (trained from scratch) baselineAUROC0.7206Clinical Diagnosis · few-shot · training=from-scratch · training_samples=300Schema-Adaptive Tabular Representation Learning with LLMs for Generalizable Multimodal Clinical Reasoning
Source quote
L256: 300 │ 0.9362 │ 0.7206
2025Adaptive two-stage framework (Triage Model) proposedtest AUROC0.929Alzheimer Disease Progression Prediction · split: testAn Adaptive Machine Learning Triage Framework for Predicting Alzheimer's Disease Progression
Source quote
L4: Accurate predictions of conversion from mild cognitive impairment (MCI) to Alzheimer's disease (AD) can enable effective personalized therapy. While cognitive tests and clinical data are routinely collected, they lack the predictive power of PET scans and CSF biomarker analysis, which are prohibitively expensive to obtain for every patient. To address this cost-accuracy dilemma, we design a two-stage machine learning framework that selectively obtains advanced, costly features based on their predicted ``value of information''. We apply our framework to predict AD progression for MCI patients using data from the Alzheimer's Disease Neuroimaging Initiative (ADNI). Our framework reduces the need for advanced testing by 20% while achieving a test AUROC of 0.929, comparable to the model that uses both basic and advanced features (AUROC=0.915, p=0.1010). We also provide an example interpretability analysis showing how one may explain the triage decision. Our work presents an interpretable, data-driven framework that optimizes AD diagnostic pathways and balances accuracy with cost, representing a step towards making early, reliable AD prediction more accessible in real-world practice. Future work should consider multiple categories of advanced features and larger-scale validation.
2025BrainFound proposedAUROC0.830Disease Classification · diagnosis=AD classification · train-cohort=NACCTowards Generalisable Foundation Models for 3D Brain MRI
Source quote
L167: To assess external validity, we conducted six cross-cohort evaluations where models trained on one dataset were tested on independent cohorts for Alzheimer’s disease (AD) classification. When trained on the NACC dataset, BrainFound achieved the highest AUROC in all target cohorts: 0.830 on ADNI, 0.880 on OASIS, and 0.799 on AIBL, outperforming all baselines (Figure \ref{fig:fig6}).
2025Autoencoder KL proposedAUROC0.69Image Classification · split: testResolution Invariant Autoencoder
Source quote
L98: HR Testing │ \multicolumn{1}{c|}{0.78} │ \multicolumn{1}{c|}{0.69} │ 0.67 │ \multicolumn{1}{c|}{0.78} │ \multicolumn{1}{c|}{0.74} │ 0.77
2025AE-KL Invariant (Resolution Invariant AE) proposedAUROC0.74Image Classification · split: testResolution Invariant Autoencoder
Source quote
L98: HR Testing │ \multicolumn{1}{c|}{0.78} │ \multicolumn{1}{c|}{0.69} │ 0.67 │ \multicolumn{1}{c|}{0.78} │ \multicolumn{1}{c|}{0.74} │ 0.77
2025Model using both basic and advanced features (Advanced Model) baselinetest AUROC0.915Alzheimer Disease Progression Prediction · split: testAn Adaptive Machine Learning Triage Framework for Predicting Alzheimer's Disease Progression
Source quote
L4: Accurate predictions of conversion from mild cognitive impairment (MCI) to Alzheimer's disease (AD) can enable effective personalized therapy. While cognitive tests and clinical data are routinely collected, they lack the predictive power of PET scans and CSF biomarker analysis, which are prohibitively expensive to obtain for every patient. To address this cost-accuracy dilemma, we design a two-stage machine learning framework that selectively obtains advanced, costly features based on their predicted ``value of information''. We apply our framework to predict AD progression for MCI patients using data from the Alzheimer's Disease Neuroimaging Initiative (ADNI). Our framework reduces the need for advanced testing by 20% while achieving a test AUROC of 0.929, comparable to the model that uses both basic and advanced features (AUROC=0.915, p=0.1010). We also provide an example interpretability analysis showing how one may explain the triage decision. Our work presents an interpretable, data-driven framework that optimizes AD diagnostic pathways and balances accuracy with cost, representing a step towards making early, reliable AD prediction more accessible in real-world practice. Future work should consider multiple categories of advanced features and larger-scale validation.
2024MORPHADE (unsupervised) proposedAUROC0.80Classification · split: test · method=unsupervised · training=760 healthy controlsUnsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable Autoencoders
Source quote
L96: In this section, we assess the capability of MORPHADE in detecting AD at the patient level. Table \ref{tab::benchmark_anomaly_detection} shows the Area Under the Receiver Operating Characteristic curve (AUROC) scores obtained when comparing our method to various baselines for identifying subjects with AD compared to healthy control (HC) subjects. Our model achieves an AUROC of 0.80, surpassing even the 3D supervised baselines ResNet \cite{supervised_resnet} and DenseNet \cite{supervised_densenet}, with AUROCs of 0.77 and 0.74, respectively.
2024LR (logistic regression) baselineAverage test AUROC56.2%Clinical Prediction · split: test · model=logistic-regression · history=current-context-only · evaluation=average-across-five-splits · aggregation=sumHow Should We Represent History in Interpretable Models of Clinical Policies?
Source quote
L550: \multirow[c]{8}{*}{ADNI} │ X_t │ \begin{tabular}[c]{@{}c@{}}54.2\\(51.4, 57.0) │ \begin{tabular}[c]{@{}c@{}}56.2\\(54.4, 57.4) │ \begin{tabular}[c]{@{}c@{}}53.9\\(52.1, 55.9) │ \begin{tabular}[c]{@{}c@{}}55.6\\(54.1, 57.0)
2024LR (logistic regression) baselineAverage test AUROC64.4%Clinical Prediction · split: test · model=logistic-regression · history=aggregated-history · evaluation=average-across-five-splits · aggregation=sumHow Should We Represent History in Interpretable Models of Clinical Policies?
Source quote
L553: \bar{H}_t │ \begin{tabular}[c]{@{}c@{}}63.0\\(61.3, 64.7) │ \begin{tabular}[c]{@{}c@{}}64.4\\(62.8, 65.9) │ \begin{tabular}[c]{@{}c@{}}64.9\\(63.1, 66.7) │ \begin{tabular}[c]{@{}c@{}}64.1\\(62.2, 65.3)
2024ResNet (3D supervised baseline) baselineAUROC0.77Classification · split: test · backbone=3D ResNet · training=includes 430 AD samplesUnsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable Autoencoders
Source quote
L96: In this section, we assess the capability of MORPHADE in detecting AD at the patient level. Table \ref{tab::benchmark_anomaly_detection} shows the Area Under the Receiver Operating Characteristic curve (AUROC) scores obtained when comparing our method to various baselines for identifying subjects with AD compared to healthy control (HC) subjects. Our model achieves an AUROC of 0.80, surpassing even the 3D supervised baselines ResNet \cite{supervised_resnet} and DenseNet \cite{supervised_densenet}, with AUROCs of 0.77 and 0.74, respectively.
2024DenseNet (3D supervised baseline) baselineAUROC0.74Classification · split: test · backbone=3D DenseNet · training=includes 430 AD samplesUnsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable Autoencoders
Source quote
L96: In this section, we assess the capability of MORPHADE in detecting AD at the patient level. Table \ref{tab::benchmark_anomaly_detection} shows the Area Under the Receiver Operating Characteristic curve (AUROC) scores obtained when comparing our method to various baselines for identifying subjects with AD compared to healthy control (HC) subjects. Our model achieves an AUROC of 0.80, surpassing even the 3D supervised baselines ResNet \cite{supervised_resnet} and DenseNet \cite{supervised_densenet}, with AUROCs of 0.77 and 0.74, respectively.
2024Brainomaly baselineAUROC0.78Classification · split: test · method=anomaly detection · training=requires pathological samplesUnsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable Autoencoders
Source quote
L98: Furthermore, we obtain improved performance compared to methods proposed for unsupervised anomaly detection. These methods are only available in 2D, so were assessed slice-wise with the final anomaly scores obtained by averaging over the slices for each patient. f-AnoGAN \cite{fanogan}, Ganomaly \cite{ganomaly} obtained AUROCs of 0.70 and 0.72, respectively. We also outperform Brainomaly~\cite{brainomaly} (AUROC 0.78), a method that is not strictly unsupervised since it requires pathological samples during training for improved performance.
2024f-AnoGAN baselineAUROC0.70Classification · split: test · input=2D slices · scoring=mean over slicesUnsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable Autoencoders
Source quote
L98: Furthermore, we obtain improved performance compared to methods proposed for unsupervised anomaly detection. These methods are only available in 2D, so were assessed slice-wise with the final anomaly scores obtained by averaging over the slices for each patient. f-AnoGAN \cite{fanogan}, Ganomaly \cite{ganomaly} obtained AUROCs of 0.70 and 0.72, respectively. We also outperform Brainomaly~\cite{brainomaly} (AUROC 0.78), a method that is not strictly unsupervised since it requires pathological samples during training for improved performance.
2024Ganomaly baselineAUROC0.72Classification · split: test · input=2D slices · scoring=mean over slicesUnsupervised Analysis of Alzheimer’s Disease Signatures using 3D Deformable Autoencoders
Source quote
L98: Furthermore, we obtain improved performance compared to methods proposed for unsupervised anomaly detection. These methods are only available in 2D, so were assessed slice-wise with the final anomaly scores obtained by averaging over the slices for each patient. f-AnoGAN \cite{fanogan}, Ganomaly \cite{ganomaly} obtained AUROCs of 0.70 and 0.72, respectively. We also outperform Brainomaly~\cite{brainomaly} (AUROC 0.78), a method that is not strictly unsupervised since it requires pathological samples during training for improved performance.
2023CPR proposedAUROC0.763Mri Order Prediction · static-context=patient age and genderContextualized Policy Recovery: Modeling and Interpreting Medical Decisions with Adaptive Imitation Learning
Source quote
L283: Additionally, static contexts substantially increase the action-matching performance of CPR to 0.763 AUROC.
2018MATCH-Net without clinician input ablationAUROC0.962Survival Analysis · split: val · evaluation=five-fold cross-validation · clinician-input=none · prediction-horizon=0.5 yearsMATCH-Net: Dynamic Prediction in Survival Analysis using Convolutional Neural Networks
Source quote
L61: {} │ {\tau} │ {Match-Net} │ {S-TCN} │ {S-MLP} │ {FCN} │ {D-Atlas} │ {RNN} │ {MLP} │ {JM} │ {LM} auroc │ 0.5 │ 0.962~ │ 0.961~ │ 0.959~ │ 0.954~ │ 0.959~ │ 0.949* │ 0.948* │ 0.913* │ 0.909*
2018MATCH-Net without clinician input ablationAUROC0.942Survival Analysis · split: val · evaluation=five-fold cross-validation · clinician-input=none · prediction-horizon=1.0 yearsMATCH-Net: Dynamic Prediction in Survival Analysis using Convolutional Neural Networks
Source quote
L62: 1.0 │ 0.942~ │ 0.941~ │ 0.932~ │ 0.930~ │ 0.929~ │ 0.930~ │ 0.930~ │ 0.917* │ 0.914*
2018S-TCN baselineAUROC0.961Survival Analysis · split: val · evaluation=five-fold cross-validation · prediction-horizon=0.5 yearsMATCH-Net: Dynamic Prediction in Survival Analysis using Convolutional Neural Networks
Source quote
L61: {} │ {\tau} │ {Match-Net} │ {S-TCN} │ {S-MLP} │ {FCN} │ {D-Atlas} │ {RNN} │ {MLP} │ {JM} │ {LM} auroc │ 0.5 │ 0.962~ │ 0.961~ │ 0.959~ │ 0.954~ │ 0.959~ │ 0.949* │ 0.948* │ 0.913* │ 0.909*
2018S-TCN baselineAUROC0.941Survival Analysis · split: val · evaluation=five-fold cross-validation · prediction-horizon=1.0 yearsMATCH-Net: Dynamic Prediction in Survival Analysis using Convolutional Neural Networks
Source quote
L62: 1.0 │ 0.942~ │ 0.941~ │ 0.932~ │ 0.930~ │ 0.929~ │ 0.930~ │ 0.930~ │ 0.917* │ 0.914*
2017Deep CNN (ConvScore; FDG and AV-45 PET) proposedROC AUC0.89Mci Conversion Prediction · cohort=171 MCI participants · modality=FDG and AV-45 PETPredicting Cognitive Decline with Deep Learning of Brain Metabolism and Amyloid Imaging
Source quote
L267: 0.89
2017Feature VOI-based (FDG) baselineROC AUC0.82Mci Conversion Prediction · cohort=171 MCI participants · method=feature VOI · modality=FDG PETPredicting Cognitive Decline with Deep Learning of Brain Metabolism and Amyloid Imaging
Source quote
L264: 0.82
2017Feature VOI-based (AV45) baselineROC AUC0.83Mci Conversion Prediction · cohort=171 MCI participants · method=feature VOI · modality=AV-45 PETPredicting Cognitive Decline with Deep Learning of Brain Metabolism and Amyloid Imaging
Source quote
L265: 0.83