ADNI · Binary Classification
202 papers · 607 extracted observations · classification · Markdown · CSV · JSON API
Tasks on ADNIAll tasks (202)Classification (44)Alzheimer Disease Classification (13)Binary Classification (13)Disease Classification (13)Image Classification (5)Medical Image Classification (5)Image Generation (4)Image Reconstruction (4)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Proposed/measured results matching task=Binary Classification, split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Ours (DTI+text) SOTA frontier | 92.94% | 2025-08-01 | modalities=DTI+clinical-text · train-test-split=80/20 · 80/20 train/test split; 301 NC and 117 MCI in the reported cohort. | Bridging Brain Connectomes and Clinical Reports for Early Alzheimer's Disease DiagnosisSource quote92.94 |
| 2 | DinoAtten3D | 87.8% | 2025-09-01 | Test set; model selected using the lowest validation loss. | DinoAtten3D: Slice-Level Attention Aggregation of DinoV2 for 3D Brain MRI Anomaly ClassificationSource quoteFor HC vs.\ AD, our model achieves 87.80% accuracy with an F_1 score of 0.871 in the test set after selecting the model with the lowest validation loss. |
Other primary task on ADNI: Binary Classification · AUC ↑ · test (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | LSTM-Robust SOTA frontier | 0.9029 | 2019-03-01 | classes=CN-vs-AD · classifier=LDA · Test-set pairwise clinical-status prediction; an LDA classifier uses estimated MRI bi… | Training recurrent neural networks robust to incomplete data: application to Alzheimer's disease progression modelingSource quoteCN vs. AD │ 0.9029^{\star\star\star/\star\star\star/\star\star\star} │ 0.8404 │ 0.8150 │ 0.7826 |
| 2 | DinoAtten3D | 0.865 | 2025-09-01 | Test set; model selected using the lowest validation loss. | DinoAtten3D: Slice-Level Attention Aggregation of DinoV2 for 3D Brain MRI Anomaly ClassificationSource quoteAs shown in Figure~\ref{fig:cn_ad}, 174/184 HC and 99/127 AD scans are correctly classified with 0.865 AUC, indicating good convergence and limited overfitting in terms of Alzheimer's disease detection. It also achieves better accuracy and AUC compared to the baselines. |
Other primary task on ADNI: Binary Classification · ACC (accuracy) ↑ (%) · val (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Proposed method (MPC: MRI+PET+CSF) SOTA frontier (+1 variant) | 95.9% | 2014-01-01 | data=baseline · modalities=MRI+PET+CSF · validation=10-fold cross-validation repeated 10 times · ADNI baseline data; binary classification; 10-fold cross-validation repeated 10 times… | Matrix-Similarity Based Loss Function and Feature Selection for Alzheimer's Disease DiagnosisSource quoteMP and MPC were better than the same methods with single-modality data such as MRI and PET. Also, the classification performance by MPC was generally better than MP. For example, in the discrimination between AD and NC, the proposed method with MPC achieved the classification accuracy of 95.9%, sensitivity of 95.7%, specificity of 98.6%, and AUC of 98.8%, while the best performance among other competing methods with single-modality data was 93.8% (ACC), |
| 2 | CB-SVM (proposed coupled boosting) (+1 variant) | 94.7% | 2014-01-01 | comparison=AD vs NC · modalities=MRI+PET · validation=10-fold cross-validation repeated 100 times · Baseline MRI and PET data; 10-fold cross-validation repeated 100 times; model paramet… | Joint Coupled-Feature Representation and Coupled Boosting for AD DiagnosisSource quoteSpecifically, we formulate a new weight updating function, which considers both incorrectly and inconsistently classified samples. In our experiments on the ADNI dataset, the proposed method presented the best performance with accuracies of 94.7% and 80.1% for AD vs. Normal Control (NC) and MCI vs. NC classifications, respectively, outperforming the competing methods and the state-of-the-art methods. |
Other primary task on ADNI: Binary Classification · AUC ↑ · val (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | CB-SVM (proposed coupled boosting) SOTA frontier (+1 variant) | 0.975 | 2014-01-01 | comparison=AD vs NC · modalities=MRI+PET · validation=10-fold cross-validation repeated 100 times · Baseline MRI and PET data; 10-fold cross-validation repeated 100 times for AUC. | Joint Coupled-Feature Representation and Coupled Boosting for AD DiagnosisSource quoteMCI vs. NC (by CB-SRC) classifications. Regarding AUCs, we repeated the 10-fold CV 100 times to reduce the possible bias caused by different data partition, and then obtained the mean AUC value. Our best AUCs were 0.975 (AD vs. |
| 2 | NSA-Flow (NSA) | 0.675 | 2025-11-01 | classifier=random-forest · comparison=CN vs MCI · evaluation=two runs of 4-fold cross-validation · Pairwise random forest classification; mean across folds, with the table caption spec… | Non-Negative Stiefel Approximating Flow: Orthogonalish Matrix Optimization for Interpretable EmbeddingsSource quoteCN vs MCI │ NSA │ 0.663 │ 0.681 │ 0.772 │ 0.586 │ {\itshape {0.675}} |
TaskClassification (109)Alzheimer Disease Classification (40)Binary Classification (40)Disease Classification (37)Medical Image Classification (13)Mci Conversion Prediction (12)Image Reconstruction (12)
Regimefine-tuned (26)unsupervised (12)semi-supervised (10)5-fold-cross-validation (7)5-fold-cv (6)pipeline-drift-comparison (6)
Showing 14 of 14 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | DinoAtten3D proposed | AUC | 0.865 | Binary Classification · split: test | DinoAtten3D: Slice-Level Attention Aggregation of DinoV2 for 3D Brain MRI Anomaly ClassificationSource quoteL178: As shown in Figure~\ref{fig:cn_ad}, 174/184 HC and 99/127 AD scans are correctly classified with 0.865 AUC, indicating good convergence and limited overfitting in terms of Alzheimer's disease detection. It also achieves better accuracy and AUC compared to the baselines. |
| 2025 | NSA-Flow (NSA) proposed | AUC | 0.675 | Binary Classification · split: val · classifier=random-forest · comparison=CN vs MCI · evaluation=two runs of 4-fold cross-validation | Non-Negative Stiefel Approximating Flow: Orthogonalish Matrix Optimization for Interpretable EmbeddingsSource quoteL829: CN vs MCI │ NSA │ 0.663 │ 0.681 │ 0.772 │ 0.586 │ {\itshape {0.675}} |
| 2025 | PCA baseline | AUC | 0.595 | Binary Classification · split: val · classifier=random-forest · comparison=CN vs MCI · evaluation=two runs of 4-fold cross-validation | Non-Negative Stiefel Approximating Flow: Orthogonalish Matrix Optimization for Interpretable EmbeddingsSource quoteL830: CN vs MCI │ PCA │ 0.637 │ 0.645 │ 0.584 │ 0.514 │ {\itshape {0.595}} |
| 2023 | BSFL (proposed; listed as “Ours”; GCN classifier) proposed non-standard slice | AUC | 93.88% | Binary Classification · split: val · classifier=GCN · comparison=SMC-vs-NC · modalities=DTI-and-fMRI · validation=10-fold-cross-validation | Brain Structure-Function Fusing Representation Learning using Adversarial Decomposed-VAE for Analyzing MCISource quoteL274: Ours │ {\bfseries 85.97} │ {\bfseries 96.34} │ {\bfseries 75.61} │ {\bfseries 93.88} │ {\bfseries 90.85} │ {\bfseries 93.90} │ {\bfseries 87.80} │ {\bfseries 97.85} │ {\bfseries 94.30} │ {\bfseries 93.42} │ 95.12 │ {\bfseries 98.12} |
| 2023 | BSFL (proposed; listed as “Ours”; GCN classifier) proposed non-standard slice | AUC | 98.12% | Binary Classification · split: val · classifier=GCN · comparison=LMCI-vs-NC · modalities=DTI-and-fMRI · validation=10-fold-cross-validation | Brain Structure-Function Fusing Representation Learning using Adversarial Decomposed-VAE for Analyzing MCISource quoteL274: Ours │ {\bfseries 85.97} │ {\bfseries 96.34} │ {\bfseries 75.61} │ {\bfseries 93.88} │ {\bfseries 90.85} │ {\bfseries 93.90} │ {\bfseries 87.80} │ {\bfseries 97.85} │ {\bfseries 94.30} │ {\bfseries 93.42} │ 95.12 │ {\bfseries 98.12} |
| 2023 | GBDM (GCN classifier) baseline non-standard slice | AUC | 81.81% | Binary Classification · split: val · classifier=GCN · comparison=SMC-vs-NC · modalities=DTI-and-fMRI · validation=10-fold-cross-validation | Brain Structure-Function Fusing Representation Learning using Adversarial Decomposed-VAE for Analyzing MCISource quoteL273: GBDM │ 81.70 │ 89.02 │ 74.39 │ 81.81 │ 86.58 │ 89.02 │ 84.14 │ 89.75 │ 91.13 │ 86.84 │ 95.12 │ 89.68 |
| 2023 | GBDM (GCN classifier) baseline non-standard slice | AUC | 89.75% | Binary Classification · split: val · classifier=GCN · comparison=EMCI-vs-NC · modalities=DTI-and-fMRI · validation=10-fold-cross-validation | Brain Structure-Function Fusing Representation Learning using Adversarial Decomposed-VAE for Analyzing MCISource quoteL273: GBDM │ 81.70 │ 89.02 │ 74.39 │ 81.81 │ 86.58 │ 89.02 │ 84.14 │ 89.75 │ 91.13 │ 86.84 │ 95.12 │ 89.68 |
| 2023 | GBDM (GCN classifier) baseline non-standard slice | AUC | 89.68% | Binary Classification · split: val · classifier=GCN · comparison=LMCI-vs-NC · modalities=DTI-and-fMRI · validation=10-fold-cross-validation | Brain Structure-Function Fusing Representation Learning using Adversarial Decomposed-VAE for Analyzing MCISource quoteL273: GBDM │ 81.70 │ 89.02 │ 74.39 │ 81.81 │ 86.58 │ 89.02 │ 84.14 │ 89.75 │ 91.13 │ 86.84 │ 95.12 │ 89.68 |
| 2019 | LSTM-Robust proposed | AUC | 0.9029 | Binary Classification · split: test · classes=CN-vs-AD · classifier=LDA | Training recurrent neural networks robust to incomplete data: application to Alzheimer's disease progression modelingSource quoteL230: CN vs. AD │ 0.9029^{\star\star\star/\star\star\star/\star\star\star} │ 0.8404 │ 0.8150 │ 0.7826 |
| 2019 | LSTM-Mean baseline | AUC | 0.8404 | Binary Classification · split: test · classes=CN-vs-AD · classifier=LDA · imputation=mean | Training recurrent neural networks robust to incomplete data: application to Alzheimer's disease progression modelingSource quoteL230: CN vs. AD │ 0.9029^{\star\star\star/\star\star\star/\star\star\star} │ 0.8404 │ 0.8150 │ 0.7826 |
| 2014 | Proposed method (MPC: MRI+PET+CSF) proposed | AUC | 98.8% | Binary Classification · split: val · data=baseline · modalities=MRI+PET+CSF · validation=10-fold cross-validation repeated 10 times | Matrix-Similarity Based Loss Function and Feature Selection for Alzheimer's Disease DiagnosisSource quoteL243: MP and MPC were better than the same methods with single-modality data such as MRI and PET. Also, the classification performance by MPC was generally better than MP. For example, in the discrimination between AD and NC, the proposed method with MPC achieved the classification accuracy of 95.9%, sensitivity of 95.7%, specificity of 98.6%, and AUC of 98.8%, while the best performance among other competing methods with single-modality data was 93.8% (ACC), |
| 2014 | Proposed method (MPC: MRI+PET+CSF) proposed | AUC | 87.0% | Binary Classification · split: val · data=baseline · modalities=MRI+PET+CSF · validation=10-fold cross-validation repeated 10 times | Matrix-Similarity Based Loss Function and Feature Selection for Alzheimer's Disease DiagnosisSource quoteL513: 87.0 |
| 2014 | CB-SVM (proposed coupled boosting) proposed | AUC | 0.975 | Binary Classification · split: val · comparison=AD vs NC · modalities=MRI+PET · validation=10-fold cross-validation repeated 100 times | Joint Coupled-Feature Representation and Coupled Boosting for AD DiagnosisSource quoteL386: MCI vs. NC (by CB-SRC) classifications. Regarding AUCs, we repeated the 10-fold CV 100 times to reduce the possible bias caused by different data partition, and then obtained the mean AUC value. Our best AUCs were 0.975 (AD vs. |
| 2014 | CB-SRC (proposed coupled boosting) proposed | AUC | 0.833 | Binary Classification · split: val · comparison=MCI vs NC · modalities=MRI+PET · validation=10-fold cross-validation repeated 100 times | Joint Coupled-Feature Representation and Coupled Boosting for AD DiagnosisSource quoteL387: NC) and 0.833 (MCI vs. NC), better than results in [21]. |