ADNI

202 papers · 607 extracted observations · classification · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Classification.

46.963.580.196.7201220192026QDA: 66.14 (2012)QDA: 68.0 (2012)TabSeq: 64.44 (2024)TabSeq: 75.13 (2024)GLIM-Net: 77.9 (2024)MST-former (3 scales): 90.3 (2024)ConnectomeDiffuser: 71.25 (2025)MedOrch: 50.35 (2025)MedOrch (o1-mini, best@5): 93.26 (2025)M3D + LGA: 76.7 (2025)RCL: 89.3 (2025)Reinforced Domain Selection: 90.5 (2025)Artemis: 84.3 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 15 of 15 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025BrainMAP proposedAUC91.5%Disease Classification · split: val · 5-fold-cross-validation · CNA=64 · GIAC=32BrainMAP: Multimodal Graph Learning For Efficient Brain Disease Localization
Source quote
L215: 82.3 │ 91.5
2025NSA-Flow (NSA) proposedAUC0.765Multi Class Classification · split: val · classifier=random-forest · evaluation=two runs of 4-fold cross-validationNon-Negative Stiefel Approximating Flow: Orthogonalish Matrix Optimization for Interpretable Embeddings
Source quote
L838: Multi-class │ NSA │ {\itshape {0.765}}
2025NSA-Flow (NSA) proposedAUC0.675Binary Classification · split: val · classifier=random-forest · comparison=CN vs MCI · evaluation=two runs of 4-fold cross-validationNon-Negative Stiefel Approximating Flow: Orthogonalish Matrix Optimization for Interpretable Embeddings
Source quote
L829: CN vs MCI │ NSA │ 0.663 │ 0.681 │ 0.772 │ 0.586 │ {\itshape {0.675}}
2025PCA baselineAUC0.719Multi Class Classification · split: val · classifier=random-forest · evaluation=two runs of 4-fold cross-validationNon-Negative Stiefel Approximating Flow: Orthogonalish Matrix Optimization for Interpretable Embeddings
Source quote
L839: Multi-class │ PCA │ {\itshape {0.719}}
2025PCA baselineAUC0.595Binary Classification · split: val · classifier=random-forest · comparison=CN vs MCI · evaluation=two runs of 4-fold cross-validationNon-Negative Stiefel Approximating Flow: Orthogonalish Matrix Optimization for Interpretable Embeddings
Source quote
L830: CN vs MCI │ PCA │ 0.637 │ 0.645 │ 0.584 │ 0.514 │ {\itshape {0.595}}
2023BSFL (proposed; listed as “Ours”; GCN classifier) proposed non-standard sliceAUC93.88%Binary Classification · split: val · classifier=GCN · comparison=SMC-vs-NC · modalities=DTI-and-fMRI · validation=10-fold-cross-validationBrain Structure-Function Fusing Representation Learning using Adversarial Decomposed-VAE for Analyzing MCI
Source quote
L274: Ours │ {\bfseries 85.97} │ {\bfseries 96.34} │ {\bfseries 75.61} │ {\bfseries 93.88} │ {\bfseries 90.85} │ {\bfseries 93.90} │ {\bfseries 87.80} │ {\bfseries 97.85} │ {\bfseries 94.30} │ {\bfseries 93.42} │ 95.12 │ {\bfseries 98.12}
2023BSFL (proposed; listed as “Ours”; GCN classifier) proposed non-standard sliceAUC98.12%Binary Classification · split: val · classifier=GCN · comparison=LMCI-vs-NC · modalities=DTI-and-fMRI · validation=10-fold-cross-validationBrain Structure-Function Fusing Representation Learning using Adversarial Decomposed-VAE for Analyzing MCI
Source quote
L274: Ours │ {\bfseries 85.97} │ {\bfseries 96.34} │ {\bfseries 75.61} │ {\bfseries 93.88} │ {\bfseries 90.85} │ {\bfseries 93.90} │ {\bfseries 87.80} │ {\bfseries 97.85} │ {\bfseries 94.30} │ {\bfseries 93.42} │ 95.12 │ {\bfseries 98.12}
2023GBDM (GCN classifier) baseline non-standard sliceAUC81.81%Binary Classification · split: val · classifier=GCN · comparison=SMC-vs-NC · modalities=DTI-and-fMRI · validation=10-fold-cross-validationBrain Structure-Function Fusing Representation Learning using Adversarial Decomposed-VAE for Analyzing MCI
Source quote
L273: GBDM │ 81.70 │ 89.02 │ 74.39 │ 81.81 │ 86.58 │ 89.02 │ 84.14 │ 89.75 │ 91.13 │ 86.84 │ 95.12 │ 89.68
2023GBDM (GCN classifier) baseline non-standard sliceAUC89.75%Binary Classification · split: val · classifier=GCN · comparison=EMCI-vs-NC · modalities=DTI-and-fMRI · validation=10-fold-cross-validationBrain Structure-Function Fusing Representation Learning using Adversarial Decomposed-VAE for Analyzing MCI
Source quote
L273: GBDM │ 81.70 │ 89.02 │ 74.39 │ 81.81 │ 86.58 │ 89.02 │ 84.14 │ 89.75 │ 91.13 │ 86.84 │ 95.12 │ 89.68
2023GBDM (GCN classifier) baseline non-standard sliceAUC89.68%Binary Classification · split: val · classifier=GCN · comparison=LMCI-vs-NC · modalities=DTI-and-fMRI · validation=10-fold-cross-validationBrain Structure-Function Fusing Representation Learning using Adversarial Decomposed-VAE for Analyzing MCI
Source quote
L273: GBDM │ 81.70 │ 89.02 │ 74.39 │ 81.81 │ 86.58 │ 89.02 │ 84.14 │ 89.75 │ 91.13 │ 86.84 │ 95.12 │ 89.68
2020ASMFS proposedAUC0.9703Disease Classification · split: val · 10-fold-cross-validation · cohort=51 AD; 52 NC · modalities=MRI+FDG-PETASMFS: Adaptive-Similarity-based Multi-modality Feature Selection for Classification of Alzheimer's Disease
Source quote
L612: Table 2 lists the classification results of AD vs. NC produced by seven methods. The standard deviations are given and the best results are denoted in bold in Table 2. As observed, our proposed method (ASMFS) consistently achieves the best performance from all the methods in comparison. Specifically, ASMFS achieves the accuracy of 96.76%, the sensitivity of 96.1%, the specificity of 97.47%, the AUC of 0.9703 and the F1 Score of 96.63. Among the three multi-modality feature selection methods, i.e., MTFS, M2TFS and ASMFS, we can find that over 95% accuracy is achieved by M2TFS and ASMFS, indicating that maintaining inter-modality information is effective for feature selection. Furthermore, compared with
2014Proposed method (MPC: MRI+PET+CSF) proposedAUC98.8%Binary Classification · split: val · data=baseline · modalities=MRI+PET+CSF · validation=10-fold cross-validation repeated 10 timesMatrix-Similarity Based Loss Function and Feature Selection for Alzheimer's Disease Diagnosis
Source quote
L243: MP and MPC were better than the same methods with single-modality data such as MRI and PET. Also, the classification performance by MPC was generally better than MP. For example, in the discrimination between AD and NC, the proposed method with MPC achieved the classification accuracy of 95.9%, sensitivity of 95.7%, specificity of 98.6%, and AUC of 98.8%, while the best performance among other competing methods with single-modality data was 93.8% (ACC),
2014Proposed method (MPC: MRI+PET+CSF) proposedAUC87.0%Binary Classification · split: val · data=baseline · modalities=MRI+PET+CSF · validation=10-fold cross-validation repeated 10 timesMatrix-Similarity Based Loss Function and Feature Selection for Alzheimer's Disease Diagnosis
Source quote
L513: 87.0
2014CB-SVM (proposed coupled boosting) proposedAUC0.975Binary Classification · split: val · comparison=AD vs NC · modalities=MRI+PET · validation=10-fold cross-validation repeated 100 timesJoint Coupled-Feature Representation and Coupled Boosting for AD Diagnosis
Source quote
L386: MCI vs. NC (by CB-SRC) classifications. Regarding AUCs, we repeated the 10-fold CV 100 times to reduce the possible bias caused by different data partition, and then obtained the mean AUC value. Our best AUCs were 0.975 (AD vs.
2014CB-SRC (proposed coupled boosting) proposedAUC0.833Binary Classification · split: val · comparison=MCI vs NC · modalities=MRI+PET · validation=10-fold cross-validation repeated 100 timesJoint Coupled-Feature Representation and Coupled Boosting for AD Diagnosis
Source quote
L387: NC) and 0.833 (MCI vs. NC), better than results in [21].