ADNI
202 papers · 607 extracted observations · classification · Markdown · CSV · JSON API
Tasks on ADNIAll tasks (202)Classification (44)Alzheimer Disease Classification (13)Binary Classification (13)Disease Classification (13)Image Classification (5)Medical Image Classification (5)Image Generation (4)Image Reconstruction (4)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Proposed/measured results matching task=Classification.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | MedOrch (o1-mini, best@5) SOTA frontier (+1 variant) | 93.26% | 2025-06-01 | Three-class AD vs. MCI vs. NC diagnosis; best@5 counts a case correct if any of five … | MedOrch: Medical Diagnosis with Tool-Augmented Reasoning Agents for Flexible ExtensibilitySource quoteDiagnostic Performance. On the three-class AD vs. MCI vs. NC classification task, \texttt{MedOrch}\xspace with o1-mini using the best@5 strategy achieves the highest accuracy of 93.26%, outperforming all baseline methods, including the previous state-of-the-art ConvNext+GPT approach (89.05%). This represents a 4.21% absolute improvement in accuracy. Similar patterns are observed in the four-class classification tasks (AD vs. EMCI vs. LMCI vs. NC), where \texttt{MedOrch}\xspace consistently outperforms baselines across all metrics. The significant improvement highlights the value of \texttt{MedOrch}\xspace' dynamic tool-calling approach, which can adapt its information-gathering strategy to each specific case. |
| 2 | Reinforced Domain Selection (+1 variant) | 90.5% | 2025-10-01 | CDA comparison with four intermediate domains; ADNI classification across five diseas… | Reinforced Domain Selection for Continuous Domain AdaptationSource quoteOurs │ 93.4 │ 90.5 |
| 3 | MST-former (3 scales) SOTA frontier (+1 variant) | 90.3% | 2024-02-01 | resolution=256x256 · Next-status prediction among NC, MCI, and AD from clips of 3 MRI scans (256×256×256). | Multi-Scale Spatio-Temporal Transformer-Based Imbalanced Longitudinal Learning for Glaucoma Forecasting From Irregular Time Series ImagesSource quoteOurs │ 0.966 │ 90.3 │ 87.0 │ 94.2 |
| 4 | Artemis | 84.3% | 2026-06-01 | classes=NC vs. MCI · ADNI benchmark task: NC vs. MCI; reported score. | Artemis: Anatomy-Resolved inTervention for Eliminating Multimodal NeuroImage confounderSSource quoteOn ADNI, Artemis achieves 84.3% accuracy, a +5.0% absolute improvement over the best baseline BrainNetCNN (79.3%), and a macro-F1 of 73.5% compared with BrainNetCNN's 52.4%, a +21.1 percentage-point gain that reflects far more balanced recall across the NC and MCI classes. |
| 5 | M3D + LGA | 76.7% | 2025-09-01 | runs=5 · backbone=M3D · component=LGA · training-samples=1,504 · Three-way classification; M3D backbone with LGA fine-tuning; 1,504 training samples; … | Data-Efficient Fine-Tuning of Vision-Language Models for Diagnosis of Alzheimer's DiseaseSource quote\quad + LGA~\cite{hu2024lga} │ 76.7 │ 80.0 │ + 85.2M │ 1,504 |
| 6 | TabSeq SOTA frontier (+1 variant) | 75.13% | 2024-01-01 | partition=70:15:15 · feature-ordering=with; k-means, 5 clusters, ascending · target-attribute=ABETA12 · Acc.* (with feature ordering); k-means with 5 clusters, ascending order; dataset part… | TabSeq: A Framework for Deep Learning on Tabular Data via Sequential OrderingSource quoteTabSeq (ours) │ 64.44% │ 0.55 │ 75.13% │ 0.71 |
| 7 | ConnectomeDiffuser | 71.25% | 2025-01-01 | Classification performance for brain network construction methods; the cited table do… | ConnectomeDiffuser: Generative AI Enables Brain Network Construction From Diffusion Tensor ImagingSource quote\multirow{6}{*}{ADNI} │ ConnectomeDiffuser │ 71.25 │ 71.84 │ 71.25 │ 71.09 |
| 8 | QDA SOTA frontier (+1 variant) | 68% | 2012-01-01 | features=shape, PET, APOE carrier status, CSF Aβ-42 and ptau181 · weighting=η=0.8 · classifier=QDA · ADNI baseline data; analysis adds log-transformed CSF Aβ-42 and ptau181 to the preced… | Genetic, Structural and Functional Imaging Biomarkers for Early Detection of Conversion from MCI to ADSource quote29 NL, 36 AD and 59 MCI. With CSF-biomarkers, a slight increase in accuracy was observed for QDA: accuracy=68% and AUC= 0.72 (η = 0.8). |
Other primary task on ADNI: Disease Classification · ACC ↑ (%) · test (4 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | R-GenIMA (Qwen) SOTA frontier (+1 variant) | 99.01% | 2025-12-01 | labels=NC, SMC, MCI, AD · data-configuration=Mixture Dataset · paired-sample-fraction=50% · unimodal-sample-fraction=50% SNP-only · Mixture data configuration: 50% paired SNPs–MRI samples and 50% SNP-only samples. Fou… | R-GenIMA: Integrating Neuroimaging and Genetics with Interpretable Multimodal AI for Alzheimer's Disease ProgressionSource quoteR-GenIMA (Qwen) │ 99.01% │ 98.50% |
| 2 | HGGAN-proposed multimodal connectivity matrix (MC), evaluated with GCN SOTA frontier (+5 variants) | 93.02% | 2021-07-01 | classifier=GCN · train-test-split=65/35 · random-initializations=5 · ADNI data; 65% training / 35% testing split; models randomly initialized 5 times. GCN… | Characterization Multimodal Connectivity of Brain Network by Hypergraph GAN for Alzheimer's Disease AnalysisSource quote\quad │ MC(Ours) │ 93.02 │ 94.11 │ 92.30 │ 90.24 │ 82.35 │ 88.46 │ 72.00 │ 82.35 │ 50.00 |
| 3 | MediAD (‡; Monte Carlo-sampling FDA) | 90.38% | 2025-07-01 | classes=3 · Three-class CN/MCI/AD classification; internal test on ADNI. | Cross-modal Causal Intervention for Alzheimer's Disease PredictionSource quoteMediAD (\ddagger) │ 90.38 │ 90.22 │ 91.48 │ 89.05 │ 97.06 │ 75.00 │ 75.53 │ 76.07 │ 75.00 │ 88.13 |
| 4 | CvFormer with self-supervised pretraining | 89.09% | 2023-09-01 | pretraining=self-supervised · ADNI; self-supervised pretraining; 70% train, 10% validation, 20% test, repeated ten … | CvFormer: Cross-view transFormers with pre-training for fMRI analysis of human brainSource quote\checkmark │ 89.09 │ 87.35 |
Other primary task on ADNI: Alzheimer Disease Classification · AUC ↑ · test (3 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Proposed 3D Swin pretraining (L_domain + L_self + L_contrast) SOTA frontier | 0.9623 | 2024-10-01 | Task ablation; all three task groups are enabled. The cited table does not state an a… | Domain Aware Multi-Task Pretraining of 3D Swin Transformer for T1-weighted Brain MRISource quote\ding{51} │ \ding{51} │ \ding{51} │ \ 0.9462 \ │ \ 0.9623 \ |
| 2 | CITab (table's “Ours” configuration) | 0.96 | 2025-12-01 | timepoints=one per subject · pretraining=three cohorts · split_protocol=subject-wise 7:1:2 · Reported in the ablation and alternative-module table. Alzheimer’s diagnosis on the A… | Unleashing the Power of Image-Tabular Self-Supervised Learning via Breaking Cross-Tabular BarriersSource quoteOurs │ 0.846 │ 0.960 │ 0.834 │ 0.817 │ 0.895 │ 0.682 │ 0.728 │ 0.851 │ 0.651 |
| 3 | MUSE+ SOTA frontier (+1 variant) | 0.9309 | 2024-01-01 | classes=normal-control-mild-cognitive-impairment-alzheimers-disease · training-data=labeled-and-unlabeled-patients · missing-labels=50%-randomly-masked · Additional Table 7; classify visits as normal control, mild cognitive impairment, or … | Multimodal Patient Representation Learning with Missing Modalities and LabelsSource quote0.9309 modality-agnostic and label-decisive features. In contrast, the classification loss leverages modelspecific and label-decisive features to enhance prediction performance. To empirically support this, we provide additional ablation study on the supervised contrastive loss in terms of the AUC-ROC score in Tab. 7. This ablation study demonstrates the contribution of the supervised contrastive loss to the overall model performance. |
Other primary task on ADNI: Binary Classification · ACC (accuracy) ↑ (%) · test (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Ours (DTI+text) SOTA frontier | 92.94% | 2025-08-01 | modalities=DTI+clinical-text · train-test-split=80/20 · 80/20 train/test split; 301 NC and 117 MCI in the reported cohort. | Bridging Brain Connectomes and Clinical Reports for Early Alzheimer's Disease DiagnosisSource quote92.94 |
| 2 | DinoAtten3D | 87.8% | 2025-09-01 | Test set; model selected using the lowest validation loss. | DinoAtten3D: Slice-Level Attention Aggregation of DinoV2 for 3D Brain MRI Anomaly ClassificationSource quoteFor HC vs.\ AD, our model achieves 87.80% accuracy with an F_1 score of 0.871 in the test set after selecting the model with the lowest validation loss. |
Other primary task on ADNI: Diagnosis · Acc ↑ (%) · test (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Hybrid manifold learning + bagging trees (proposed) SOTA frontier | 86% | 2016-01-01 | classes=3-class · test-size=150 · training-size=2008 · Diagnosis comparison; the described holdout randomly samples 50 records per class for… | Bagging Ensembles for the Diagnosis and Prognostication of Alzheimer's DiseaseSource quote86.0 |
| 2 | CERD (Full) | 65.64% | 2026-04-01 | setting=IGCB · modalities=four · Ablation study; four-modality IGCB setting; train/validation/test split 0.7:0.15:0.15… | Conditional Evidence Reconstruction and Decomposition for Interpretable Multimodal DiagnosisSource quoteCERD (Full) │ \checkmark │ \checkmark │ × │ \checkmark │ 65.64 │ 64.06 │ 82.03 |
TaskClassification (109)Alzheimer Disease Classification (40)Binary Classification (40)Disease Classification (37)Medical Image Classification (13)Mci Conversion Prediction (12)Image Reconstruction (12)
Regimefine-tuned (26)unsupervised (12)semi-supervised (10)5-fold-cross-validation (7)5-fold-cv (6)pipeline-drift-comparison (6)
Showing 150 of 189 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | OctEncoder proposed | ACC | 0.782 | Classification · comparison=MCI vs CN · representation=tetrahedral mesh | Hierarchical Mesh Transformers with Topology-Guided Pretraining for Morphometric Analysis of Brain StructuresSource quoteL135: OctEncoder │ 0.907 │ 0.902 │ 0.914 │ 0.731 │ 0.650 │ 0.812 │ 0.782 │ 0.761 │ 0.807 │ 0.763 │ 0.751 │ 0.774 |
| 2026 | OctEncoder proposed non-standard slice | ACC | 0.763 | Amyloid Positivity Prediction · input=mesh-only · subset=medium-risk | Hierarchical Mesh Transformers with Topology-Guided Pretraining for Morphometric Analysis of Brain StructuresSource quoteL135: OctEncoder │ 0.907 │ 0.902 │ 0.914 │ 0.731 │ 0.650 │ 0.812 │ 0.782 │ 0.761 │ 0.807 │ 0.763 │ 0.751 │ 0.774 |
| 2026 | OctEncoder + pTau proposed non-standard slice | ACC | 0.815 | Amyloid Positivity Prediction · fusion=pTau-217 · subset=medium-risk | Hierarchical Mesh Transformers with Topology-Guided Pretraining for Morphometric Analysis of Brain StructuresSource quoteL136: OctEncoder + pTau │ --- │ --- │ --- │ --- │ --- │ --- │ --- │ --- │ --- │ 0.815 │ 0.781 │ 0.848 |
| 2026 | CERD (Full) proposed | Acc | 65.64% | Diagnosis · split: test · setting=IGCB · modalities=four | Conditional Evidence Reconstruction and Decomposition for Interpretable Multimodal DiagnosisSource quoteL196: CERD (Full) │ \checkmark │ \checkmark │ × │ \checkmark │ 65.64 │ 64.06 │ 82.03 |
| 2026 | Artemis proposed | accuracy | 84.3% | Classification · classes=NC vs. MCI | Artemis: Anatomy-Resolved inTervention for Eliminating Multimodal NeuroImage confounderSSource quoteL278: On ADNI, Artemis achieves 84.3% accuracy, a +5.0% absolute improvement over the best baseline BrainNetCNN (79.3%), and a macro-F1 of 73.5% compared with BrainNetCNN's 52.4%, a +21.1 percentage-point gain that reflects far more balanced recall across the NC and MCI classes. |
| 2026 | DeCI proposed | Accuracy | +11.25 pp | Classification · split: test | Moving Beyond Functional Connectivity: Time-Series Modeling for fMRI-Based Brain Disorder ClassificationSource quoteL257: Paired two-sided t-tests on the 5-fold results (Table~\ref{tab:significance}) show that DeCI significantly outperforms Leddam. On ADNI, DeCI improves Accuracy by +11.25\,pp \([8.24, 14.28]\), d_z=4.63, and F1-Score by +22.13\,pp \([13.92, 30.33]\), d_z=3.35 (both p<0.001). On Mātai, Accuracy and F1-Score improve by +3.34\,pp \([0.35, 6.31]\), d_z=1.39, and +4.04\,pp \([0.32, 7.76]\), d_z=1.35 (both p<0.05). On Neurocon, DeCI yields +4.11\,pp in Accuracy \([0.75, 7.47]\), d_z=1.81, and +2.66\,pp in F1-Score \([0.18, 5.14]\), d_z=1.33 (both p<0.05). On TaoWu, DeCI yields +11.50\,pp in Accuracy \([7.96, 15.04]\), d_z=4.03, and +13.83\,pp in F1-Score \([9.71, 17.93]\), d_z=4.17 (both p<0.001). With n{=}5 folds, d_z>1.2 denotes strong, stable improvements, met on Neurocon and Mātai and vastly exceeded on ADNI and TaoWu, highlighting DeCI’s effectiveness and robustness against overfitting on small sample datasets (e.g., Neurocon and TaoWu). |
| 2026 | Modality-anchored interaction (Ours; train from pre-trained) proposed | ACC | 0.979 | Alzheimer Disease Classification · classes=NC vs MCI · training=from pre-trained · modality-setting=modality-incomplete | Joint Adaptation of Uni-modal Foundation Models for Multi-modal Alzheimer's Disease DiagnosisSource quoteL696: 0.979 |
| 2026 | Modality-anchored interaction (Ours; train from pre-trained) proposed | ACC | 0.945 | Alzheimer Disease Classification · classes=NC vs AD · training=from pre-trained · modality-setting=modality-incomplete | Joint Adaptation of Uni-modal Foundation Models for Multi-modal Alzheimer's Disease DiagnosisSource quoteL698: 0.945 |
| 2026 | Modality-anchored interaction (Ours; C+G+F+S) proposed | ACC | 0.846 | Alzheimer Disease Classification · classes=NC vs AD · modalities=C+G+F+S · modality-setting=modality-complete | Joint Adaptation of Uni-modal Foundation Models for Multi-modal Alzheimer's Disease DiagnosisSource quoteL373: 0.846 |
| 2026 | Modality-anchored interaction (Ours; C+G+F+S) proposed | ACC | 0.763 | Alzheimer Disease Classification · classes=sMCI vs pMCI · follow-up=36-month · modalities=C+G+F+S · modality-setting=modality-complete | Joint Adaptation of Uni-modal Foundation Models for Multi-modal Alzheimer's Disease DiagnosisSource quoteL376: 0.763 |
| 2026 | scBIT with snRNA data proposed | ACC | 3.39% | Alzheimer Disease Classification · split: val · 10-fold-cross-validation · modality=fMRI + snRNA · classification=binary | scBIT: Integrating Single-Cell Transcriptomic Data Into fMRI-Based Prediction for Alzheimer's Disease DiagnosisSource quoteL234: 3.39% in ACC, 5.63% in AUC, 2.74% in SEN, and 9.71% in SPE, and in the five-class classification task of 26.59% in ACC, 7.44% in SPE, 24.98% in REC, 28.97% in PRE, and 26.89% in F1. The enhancements observed in the five-class classification task are substantially greater compared to those in the binary classification task. The reduction in standard deviation in the prediction results also indicates that the inclusion of snRNA data significantly enhances the stability of scBIT's predictions. We conducted an evaluation to determine the impact of integrating different proportions of snRNA data on the predictive performance of scBIT. This assessment involved a systematic introduction of snRNA data at 20% intervals, ranging from 20% to 80%. The results (Fig. 3(d)) clearly demonstrated that the inclusion of incremental amounts of snRNA data significantly improved the accuracy of scBIT in binary classification task. Notably, the average accuracy increased from 0.9431 with 20% snRNA data to 0.9569 |
| 2026 | scBIT with snRNA data proposed | ACC | 26.59% | Alzheimer Disease Classification · split: val · 10-fold-cross-validation · modality=fMRI + snRNA · classification=five-class | scBIT: Integrating Single-Cell Transcriptomic Data Into fMRI-Based Prediction for Alzheimer's Disease DiagnosisSource quoteL234: 3.39% in ACC, 5.63% in AUC, 2.74% in SEN, and 9.71% in SPE, and in the five-class classification task of 26.59% in ACC, 7.44% in SPE, 24.98% in REC, 28.97% in PRE, and 26.89% in F1. The enhancements observed in the five-class classification task are substantially greater compared to those in the binary classification task. The reduction in standard deviation in the prediction results also indicates that the inclusion of snRNA data significantly enhances the stability of scBIT's predictions. We conducted an evaluation to determine the impact of integrating different proportions of snRNA data on the predictive performance of scBIT. This assessment involved a systematic introduction of snRNA data at 20% intervals, ranging from 20% to 80%. The results (Fig. 3(d)) clearly demonstrated that the inclusion of incremental amounts of snRNA data significantly improved the accuracy of scBIT in binary classification task. Notably, the average accuracy increased from 0.9431 with 20% snRNA data to 0.9569 |
| 2026 | MM-KG multimodal patient representation (clinical history, biomarkers, and imaging) proposed | balanced accuracy | 0.652 | Classification | Aligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMsSource quoteL873: history improves prognosis balanced accuracy from 0.595 to 0.652 (App. L). Removing PrimeKG leaves |
| 2026 | NeuroAlign (Dual-MRI; DFC+SFC+ALFF+FA) proposed | accuracy | 0.825 | Mci Classification · split: val · modality=Dual-MRI (DFC+SFC+ALFF+FA) · validation=five-fold | NeuroAlign: Hierarchical Multimodal Fusion of Dynamic and Structural Neuroimaging for MCI AnalysisSource quoteL23: \item NeuroAlign achieves 0.825/0.735 accuracy on ADNI/OASIS in multimodal MCI classification. |
| 2026 | ChebyNet baseline | ACC | 0.735 | Classification · comparison=MCI vs CN · representation=tetrahedral mesh | Hierarchical Mesh Transformers with Topology-Guided Pretraining for Morphometric Analysis of Brain StructuresSource quoteL131: ChebyNet │ 0.870 │ 0.881 │ 0.850 │ 0.703 │ 0.790 │ 0.616 │ 0.735 │ 0.778 │ 0.667 │ 0.677 │ 0.563 │ 0.800 |
| 2026 | BrainNetCNN baseline | accuracy | 79.3% | Classification · classes=NC vs. MCI | Artemis: Anatomy-Resolved inTervention for Eliminating Multimodal NeuroImage confounderSSource quoteL278: On ADNI, Artemis achieves 84.3% accuracy, a +5.0% absolute improvement over the best baseline BrainNetCNN (79.3%), and a macro-F1 of 73.5% compared with BrainNetCNN's 52.4%, a +21.1 percentage-point gain that reflects far more balanced recall across the NC and MCI classes. |
| 2026 | Self-Attention Fusion baseline | ACC | 0.921 | Alzheimer Disease Classification · classes=NC vs MCI · modality-setting=modality-incomplete | Joint Adaptation of Uni-modal Foundation Models for Multi-modal Alzheimer's Disease DiagnosisSource quoteL690: 0.921 |
| 2026 | Self-Attention Fusion baseline | ACC | 0.901 | Alzheimer Disease Classification · classes=NC vs AD · modality-setting=modality-incomplete | Joint Adaptation of Uni-modal Foundation Models for Multi-modal Alzheimer's Disease DiagnosisSource quoteL692: 0.901 |
| 2026 | Clinical-history-only configuration baseline | balanced accuracy | 0.595 | Classification | Aligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMsSource quoteL873: history improves prognosis balanced accuracy from 0.595 to 0.652 (App. L). Removing PrimeKG leaves |
| 2025 | CITab (table's “Ours” configuration) proposed | Acc | 0.846 | Alzheimer Disease Classification · split: test · fine-tuned · timepoints=one per subject · pretraining=three cohorts · split_protocol=subject-wise 7:1:2 | Unleashing the Power of Image-Tabular Self-Supervised Learning via Breaking Cross-Tabular BarriersSource quoteL174: Ours │ 0.846 │ 0.960 │ 0.834 │ 0.817 │ 0.895 │ 0.682 │ 0.728 │ 0.851 │ 0.651 |
| 2025 | ConnectomeDiffuser proposed | ACC | 71.25% | Classification | ConnectomeDiffuser: Generative AI Enables Brain Network Construction From Diffusion Tensor ImagingSource quoteL314: \multirow{6}{*}{ADNI} │ ConnectomeDiffuser │ 71.25 │ 71.84 │ 71.25 │ 71.09 |
| 2025 | MCI-Diff (full model; labeled “Ours” in the table) proposed | ACC (classification accuracy) | 0.950 | Conversion Classification · split: test | Diffusion with a Linguistic Compass: Steering the Generation of Clinically Plausible Future sMRI Representations for Early MCI Conversion PredictionSource quoteL259: Ours │ 0.950 │ 0.947 │ 0.950 │ 0.948 │ 0.936 │ 0.882 │ 0.946 │ 0.914 |
| 2025 | IMMFM-forecast ventricular-area classifier proposed | Classification accuracy | 80.8% | Classification · split: test · input=IMMFM-forecast ventricular area · classification=AD-CN · forecast-horizon=36 months | Longitudinal Flow Matching for Trajectory ModelingSource quoteL351: Finally, we examine the specific progression of the disease. For the ADNI dataset, we focus on the ventricle region, as ventricular enlargement is a well-studied biomarker of AD progression and its underlying neurodegenerative process \citep{nestor2008ventricular}. IMMFM captures distinct ventricular growth trajectories for AD versus CN groups without explicit class conditioning (Fig.~\ref{fig:ad_dist}). Using only observed data at the second visit (\sim18 months), AD–CN classification reaches \bm{71.7%}. When using trajectories forecasted by our model to \sim36 months, AD-CN classification accuracy increases to \bm{80.8%}, a \bm{9.1%} gain. In practical terms, this corresponds to correctly classifying about nine additional subjects per 100, 18 months earlier than would be possible using only the observed data (see Appendix~\ref{app:classification_details} for additional details). |
| 2025 | Heter-LBI (proposed method; table label “Ours”) proposed | classification accuracy | 88.96% | Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=1.5T | A Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging AnalysisSource quoteL490: 88.96% |
| 2025 | Heter-LBI (proposed method; table label “Ours”) proposed | classification accuracy | 91.48% | Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=3.0T | A Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging AnalysisSource quoteL491: 91.48% |
| 2025 | Heter-LBI (proposed method; table label “Ours”) proposed | classification accuracy | 74.00% | Classification · split: val · comparison=MCI-vs-NC · validation=10-fold cross-validation · field-strength=1.5T | A Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging AnalysisSource quoteL492: 74.00% is enforced with spatial smoothness and non-negativity constraint to learn the lesion features and a dense parameter to additionally learn the procedural bias. |
| 2025 | CoCoLIT proposed | BA (balanced accuracy for Aβ-positivity classification) | 62.3% | Classification · split: test · method-setting=LAS m=64 · classification-threshold=selected on internal validation set | CoCoLIT: ControlNet-Conditioned Latent Image Translation for MRI to Amyloid PET SynthesisSource quoteL163: m=64 │ 0.896 ± 0.050 │ 24.135 ± 2.820 │ 0.0050 ± 0.0047 │ 0.328~(p<0.001) │ 0.522~(p<0.001) │ 62.3% |
| 2025 | DinoAtten3D proposed | accuracy | 87.80% | Binary Classification · split: test | DinoAtten3D: Slice-Level Attention Aggregation of DinoV2 for 3D Brain MRI Anomaly ClassificationSource quoteL177: For HC vs.\ AD, our model achieves 87.80% accuracy with an F_1 score of 0.871 in the test set after selecting the model with the lowest validation loss. |
| 2025 | MedOrch (o1-mini, best@5) proposed | Accuracy | 93.26% | Classification | MedOrch: Medical Diagnosis with Tool-Augmented Reasoning Agents for Flexible ExtensibilitySource quoteL262: Diagnostic Performance. On the three-class AD vs. MCI vs. NC classification task, \texttt{MedOrch}\xspace with o1-mini using the best@5 strategy achieves the highest accuracy of 93.26%, outperforming all baseline methods, including the previous state-of-the-art ConvNext+GPT approach (89.05%). This represents a 4.21% absolute improvement in accuracy. Similar patterns are observed in the four-class classification tasks (AD vs. EMCI vs. LMCI vs. NC), where \texttt{MedOrch}\xspace consistently outperforms baselines across all metrics. The significant improvement highlights the value of \texttt{MedOrch}\xspace' dynamic tool-calling approach, which can adapt its information-gathering strategy to each specific case. |
| 2025 | MedOrch proposed | Accuracy | 50.35% | Classification | MedOrch: Medical Diagnosis with Tool-Augmented Reasoning Agents for Flexible ExtensibilitySource quoteL264: Prediction Performance. The disease progression prediction task proves more challenging for all. However, \texttt{MedOrch}\xspace shows a more pronounced advantage in this setting, achieving 50.35% accuracy with the best@5 and 38.61% with best@1. This significant lead over the baselines highlights \texttt{MedOrch}\xspace' superior ability to analyze temporal patterns in patient data and identify relevant progression indicators through its specialized tools and agents. |
| 2025 | UG-FedDA proposed | accuracy (ACC) | 90.54% | Alzheimer Disease Classification · repeats=5 · label_pair=NC vs AD · evaluation_site=ADNI · evaluation_regime=cross-domain | UG-FedDA: Uncertainty-Guided Federated Domain Adaptation for Multi-Center Alzheimer's Disease DetectionSource quoteL301: Across the three evaluation sites ADNI, AIBL and OASIS, our method achieved accuracies of 90.54%, |
| 2025 | UG-FedDA proposed | accuracy (ACC) | 79.21% | Alzheimer Disease Classification · repeats=5 · label_pair=MCI vs AD · evaluation_site=ADNI · evaluation_regime=cross-domain | UG-FedDA: Uncertainty-Guided Federated Domain Adaptation for Multi-Center Alzheimer's Disease DetectionSource quoteL501: Across all three sites, UG-FedDA consistently delivered the strongest performance on the MCI vs AD task. On ADNI, the model achieved 79.21% accuracy, 80.00% sensitivity, and 82.82% AUC, outperforming all competing methods by a clear margin. On AIBL, UG-FedDA also reached the highest accuracy at |
| 2025 | FLIQA-AD proposed non-standard slice | classification accuracy (ACC) | 97% | Classification · split: test · subset=300 samples per category · sampling=patient-level | FLIQA-AD: a Fusion Model with Large Language Model for Better Diagnose and MMSE Prediction of Alzheimer's DiseaseSource quoteL202: 97% and 95%. |
| 2025 | MediAD (‡; Monte Carlo-sampling FDA) proposed | ACC | 90.38% | Disease Classification · split: test · classes=3 | Cross-modal Causal Intervention for Alzheimer's Disease PredictionSource quoteL335: MediAD (\ddagger) │ 90.38 │ 90.22 │ 91.48 │ 89.05 │ 97.06 │ 75.00 │ 75.53 │ 76.07 │ 75.00 │ 88.13 |
| 2025 | R-GenIMA (Qwen) proposed | Accuracy | 95.58% | Disease Classification · labels=NC, SMC, MCI, AD · genetic-data=complete paired data · imaging-encoder=ROI-wise RiT · data-configuration=Image-Gene | R-GenIMA: Integrating Neuroimaging and Genetics with Interpretable Multimodal AI for Alzheimer's Disease ProgressionSource quoteL87: R-GenIMA (Qwen) │ 95.58% │ 90.42% |
| 2025 | R-GenIMA (Qwen) proposed | Accuracy | 99.01% | Disease Classification · labels=NC, SMC, MCI, AD · data-configuration=Mixture Dataset · paired-sample-fraction=50% · unimodal-sample-fraction=50% SNP-only | R-GenIMA: Integrating Neuroimaging and Genetics with Interpretable Multimodal AI for Alzheimer's Disease ProgressionSource quoteL93: R-GenIMA (Qwen) │ 99.01% │ 98.50% |
| 2025 | M3D + LGA proposed | ACC | 76.7% | Classification · fine-tuned · runs=5 · backbone=M3D · component=LGA · training-samples=1,504 | Data-Efficient Fine-Tuning of Vision-Language Models for Diagnosis of Alzheimer's DiseaseSource quoteL235: \quad + LGA~\cite{hu2024lga} │ 76.7 │ 80.0 │ + 85.2M │ 1,504 |
| 2025 | DCMM-Transformer proposed | classification accuracy | 74.1% | Image Classification · fine-tuned · backbone=ViT-Small · input=structural connectivity matrices from MRI · epochs=100 · pretrained=true | DCMM-Transformer: Degree-Corrected Mixed-Membership Attention for Medical ImagingSource quoteL247: The DCMM-Transformer consistently outperforms all baselines across all datasets, achieving an average accuracy of 87.3%, surpassing the next-best method (MaxViT, 85.8%) by a significant margin. Notably, DCMM demonstrates the strongest gains on the ADNI dataset (74.1%), highlighting its capacity to capture subtle structural variations in brain connectivity graphs, a challenging task where standard vision transformers underperform. The model also achieves state-of-the-art performance on the ChestXray (96.0%) and SIIM-ACR (88.2%) datasets, showcasing its effectiveness on 2D radiographic images with diverse pathological characteristics. These results validate the ability of the proposed degree-corrected mixed-membership attention mechanism to enhance representation learning in medical image classification tasks. |
| 2025 | Proposed spatial-temporal transformer (Ours; temporal and spatial blocks) proposed | ACC | 89.1 | Classification · split: val · 5-fold-cv · evaluation=subject-level | Classification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal TransformerSource quoteL148: 89.1 |
| 2025 | Proposed framework with contrastive learning proposed | Accuracy improvement | 9.7% | Classification · split: val · 5-fold-cv · component=contrastive-learning · comparison=without-contrastive-learning · evaluation=subject-level | Classification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal TransformerSource quoteL114: To verify our proposed model, we compare it with other widely used methods in the literature listed in Table 1. Our results outperform most other studies. Furthermore, the proposed method incorporating contrastive learning strategy performs significantly better than the method without contrastive learning strategy on this data, showing an improvement of 9.7% in accuracy and 7.3% in F1 score when contrastive learning is applied. |
| 2025 | SAM-Brain3D + HyDA (k=28) proposed | Accuracy (ACC) | 88.34% | Medical Image Classification · split: val · cross-validation=5-fold · hypergraph-nearest-neighbor-k=28 | Brain foundation models with hypergraph dynamic adapter for brain disease analysisSource quoteL357: SAM-Brain3D + HyDA (k=28) │ 88.34 │ 71.70 │ 97.86 │ 62.19 │ 84.29 |
| 2025 | BrainMAP proposed | ACC | 82.3% | Disease Classification · split: val · 5-fold-cross-validation · CNA=64 · GIAC=32 | BrainMAP: Multimodal Graph Learning For Efficient Brain Disease LocalizationSource quoteL215: 82.3 │ 91.5 |
| 2025 | SFC-GAN (translated FC) proposed non-standard slice | Accuracy | 16.67 | Classification · split: test | SFC-GAN: A Generative Adversarial Network for Brain Functional and Structural Connectome TranslationSource quoteL161: Translated FC │ 16.67 │ 11.11 │ 16.67 │ 12.50 │ 52.18 |
| 2025 | SFC-GAN (translated SC) proposed non-standard slice | Accuracy | 41.67 | Classification · split: test | SFC-GAN: A Generative Adversarial Network for Brain Functional and Structural Connectome TranslationSource quoteL162: Translated SC │ 41.67 │ 27.78 │ 41.67 │ 33.33 │ 57.78 |
| 2025 | Reinforced Domain Selection proposed | Accuracy | 90.5 | Classification | Reinforced Domain Selection for Continuous Domain AdaptationSource quoteL180: Ours │ 93.4 │ 90.5 |
| 2025 | Ours (DTI+text) proposed | ACC | 92.94% | Binary Classification · split: test · modalities=DTI+clinical-text · train-test-split=80/20 | Bridging Brain Connectomes and Clinical Reports for Early Alzheimer's Disease DiagnosisSource quoteL408: 92.94 |
| 2025 | S-only (spatial block only) ablation | ACC | 76.6 | Classification · split: val · 5-fold-cv · ablation=spatial-block-only · evaluation=subject-level | Classification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal TransformerSource quoteL136: 76.6 |
| 2025 | I-only (imaging input) ablation | ACC | 73.77% | Binary Classification · split: test · input-modality=imaging-only · train-test-split=80/20 | Bridging Brain Connectomes and Clinical Reports for Early Alzheimer's Disease DiagnosisSource quoteL422: 73.77 |
| 2025 | C-only (clinical-text input) ablation | ACC | 86.96% | Binary Classification · split: test · input-modality=clinical-text-only · train-test-split=80/20 | Bridging Brain Connectomes and Clinical Reports for Early Alzheimer's Disease DiagnosisSource quoteL430: 86.96 |
| 2025 | LETetCNN | ACC (accuracy) | 0.794 | Classification | Enhancing Alzheimer's Diagnosis: Leveraging Anatomical Landmarks in Graph Convolutional Neural Networks on Tetrahedral MeshesSource quoteL159: LETetCNN │ 0.917 │ 0.915 │ 0.920 │ 0.755 │ 0.615 │ 0.835 │ 0.794 │ 0.778 │ 0.822 |
| 2025 | TetCNN | ACC (accuracy) | 0.730 | Classification | Enhancing Alzheimer's Diagnosis: Leveraging Anatomical Landmarks in Graph Convolutional Neural Networks on Tetrahedral MeshesSource quoteL157: TetCNN │ 0.876 │ 0.886 │ 0.859 │ 0.709 │ 0.660 │ 0.769 │ 0.730 │ 0.761 │ 0.700 |
| 2025 | KAN classifier | test accuracy | 81.85% | Classification · split: test | Interpreting Kolmogorov-Arnold Networks in Neuroimaging: A Path-Based Attribution FrameworkSource quoteL181: We train a KAN on the datasets and achieve test accuracies of 93.24%, 81.85% and 91.25% respectively, on the OASIS-1, ADNI and Mendeley test sets. We also train the KAN on MNIST classification as a Proofof-Concept (PoC) and achieve a test accuracy of 99.4%. Using the proposed path-based attribution, we obtain an Insertion AUC of 0.865 ± 0.049, Deletion AUC of 0.282 ± 0.020, and Sufficiency of 0.068 ± 0.064 on the OASIS dataset as indicated in Table 1. On ADNI, the method achieves an Insertion AUC of 0.758 |
| 2025 | RCL | Accuracy | 89.3 | Classification | Reinforced Domain Selection for Continuous Domain AdaptationSource quoteL178: RCL \cite{xu2018reinforced} │ 91.5 │ 89.3 |
| 2025 | HFCN^+ baseline | ACC (classification accuracy) | 0.899 | Conversion Classification · split: test | Diffusion with a Linguistic Compass: Steering the Generation of Clinically Plausible Future sMRI Representations for Early MCI Conversion PredictionSource quoteL255: HFCN^+ │ 0.899 │ 0.895 │ 0.900 │ 0.897 │ 0.873 │ 0.824 │ 0.882 │ 0.853 |
| 2025 | Observed-data ventricular-area classifier baseline | Classification accuracy | 71.7% | Classification · split: test · input=observed ventricular area · classification=AD-CN | Longitudinal Flow Matching for Trajectory ModelingSource quoteL351: Finally, we examine the specific progression of the disease. For the ADNI dataset, we focus on the ventricle region, as ventricular enlargement is a well-studied biomarker of AD progression and its underlying neurodegenerative process \citep{nestor2008ventricular}. IMMFM captures distinct ventricular growth trajectories for AD versus CN groups without explicit class conditioning (Fig.~\ref{fig:ad_dist}). Using only observed data at the second visit (\sim18 months), AD–CN classification reaches \bm{71.7%}. When using trajectories forecasted by our model to \sim36 months, AD-CN classification accuracy increases to \bm{80.8%}, a \bm{9.1%} gain. In practical terms, this corresponds to correctly classifying about nine additional subjects per 100, 18 months earlier than would be possible using only the observed data (see Appendix~\ref{app:classification_details} for additional details). |
| 2025 | GSplit LBI baseline | classification accuracy | 88.31% | Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=1.5T | A Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging AnalysisSource quoteL486: 88.31% |
| 2025 | GSplit LBI baseline | classification accuracy | 88.64% | Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=3.0T | A Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging AnalysisSource quoteL487: 88.64% |
| 2025 | SVM baseline | classification accuracy | 73.50% | Classification · split: val · comparison=MCI-vs-NC · validation=10-fold cross-validation · field-strength=1.5T | A Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging AnalysisSource quoteL468: 73.50% |
| 2025 | ConvNext+GPT baseline | Accuracy | 89.05% | Classification | MedOrch: Medical Diagnosis with Tool-Augmented Reasoning Agents for Flexible ExtensibilitySource quoteL262: Diagnostic Performance. On the three-class AD vs. MCI vs. NC classification task, \texttt{MedOrch}\xspace with o1-mini using the best@5 strategy achieves the highest accuracy of 93.26%, outperforming all baseline methods, including the previous state-of-the-art ConvNext+GPT approach (89.05%). This represents a 4.21% absolute improvement in accuracy. Similar patterns are observed in the four-class classification tasks (AD vs. EMCI vs. LMCI vs. NC), where \texttt{MedOrch}\xspace consistently outperforms baselines across all metrics. The significant improvement highlights the value of \texttt{MedOrch}\xspace' dynamic tool-calling approach, which can adapt its information-gathering strategy to each specific case. |
| 2025 | MedBlip baseline | ACC | 78.70% | Disease Classification · split: test · classes=3 | Cross-modal Causal Intervention for Alzheimer's Disease PredictionSource quoteL332: \texttt{MedBlip} │ 78.70 |
| 2025 | Qwen+Med3D baseline | Accuracy | 93.61% | Disease Classification · labels=NC, SMC, MCI, AD · genetic-data=complete paired data · imaging-encoder=whole-brain Med3D · data-configuration=Image-Gene | R-GenIMA: Integrating Neuroimaging and Genetics with Interpretable Multimodal AI for Alzheimer's Disease ProgressionSource quoteL85: Qwen\cite{qwen2.5}+Med3D\cite{chen2019med3d} │ 93.61% │ 85.87% |
| 2025 | Pretrained M3D (direct evaluation) baseline | ACC | 54.9% | Classification · 0-shot · runs=5 · classes=3-way | Data-Efficient Fine-Tuning of Vision-Language Models for Diagnosis of Alzheimer's DiseaseSource quoteL233: \textbf{M3D~\cite{bai2024m3d}} │ 54.9 │ 52.6 │ 198M~(0) │ -- |
| 2025 | MedBLIP (original-paper baseline) baseline | ACC | 78.7% | Classification · training-samples=10,387 | Data-Efficient Fine-Tuning of Vision-Language Models for Diagnosis of Alzheimer's DiseaseSource quoteL241: MedBLIP~\cite{chen2024medblip}{}^\dagger │ 78.7 │ 85.3 │ 1.7B~(154M) │ 10,387 |
| 2024 | Proposed 3D Swin pretraining (L_domain + L_self + L_contrast) proposed | ACC. | 0.9462 | Alzheimer Disease Classification | Domain Aware Multi-Task Pretraining of 3D Swin Transformer for T1-weighted Brain MRISource quoteL268: \ding{51} │ \ding{51} │ \ding{51} │ \ 0.9462 \ │ \ 0.9623 \ |
| 2024 | TabSeq proposed | Accuracy | 64.44% | Classification · partition=70:15:15 · feature-ordering=without · target-attribute=ABETA12 | TabSeq: A Framework for Deep Learning on Tabular Data via Sequential OrderingSource quoteL254: TabSeq (ours) │ 64.44% │ 0.55 │ 75.13% │ 0.71 |
| 2024 | TabSeq proposed | Accuracy | 75.13% | Classification · partition=70:15:15 · feature-ordering=with; k-means, 5 clusters, ascending · target-attribute=ABETA12 | TabSeq: A Framework for Deep Learning on Tabular Data via Sequential OrderingSource quoteL254: TabSeq (ours) │ 64.44% │ 0.55 │ 75.13% │ 0.71 |
| 2024 | PLM proposed | ACC | 0.8693 | Classification · split: test | Connectional-style-guided contextual representation learning for brain disease diagnosisSource quoteL328: 0.8693 |
| 2024 | Ours (inv) proposed | ACC | 81 | Image Classification · split: val · evaluation=5-fold cross-validation · invariance=scanner | Pooling Image Datasets with Multiple Covariate Shift and ImbalanceSource quoteL580: Ours (inv) │ 81{\scriptstyle(2.3)} │ {\bf 02}{\scriptstyle(2.4)} │ 52{\scriptstyle(2.0)} │ {\bf 86}{\scriptstyle(8.0)} │ {\bf 34}{\scriptstyle(01.2)} │ 45{\scriptstyle(04.2)} |
| 2024 | XGBoost proposed | accuracy | 91% | Disease Diagnosis · split: test · test-repetitions=10 · train-test-split=70/30 | Intelligent Diagnosis of Alzheimer's Disease Based on Machine LearningSource quoteL206: Forest, and SVM, is ranked in descending order. XGBoost has the highest accuracy at 91%, followed by Random Forest at 90%, and SVM at 75%. Therefore, among these three algorithms, XGBoost has the highest accuracy and is the best diagnostic method for Alzheimer's disease. |
| 2024 | ADAPT (1+1+2+2 encoder-layer configuration) proposed | test acc. | 0.924 | Binary Classification · split: test · slices=48 total; 16 per view · classes=AD/normal · sampling=important sampling · configuration=1+1+2+2 encoder layers | ADAPT: Alzheimer Diagnosis through Adaptive Profiling TransformersSource quoteL397: 0.924 |
| 2024 | Proposed 3D Swin pretraining (L_domain only) ablation | ACC. | 0.9348 | Alzheimer Disease Classification | Domain Aware Multi-Task Pretraining of 3D Swin Transformer for T1-weighted Brain MRISource quoteL262: \ding{51} │ \ 0.9348 \ │ \ 0.9468 \ |
| 2024 | MST-former (3 scales) | ACC (Accuracy) | 90.3% | Classification · resolution=256x256 | Multi-Scale Spatio-Temporal Transformer-Based Imbalanced Longitudinal Learning for Glaucoma Forecasting From Irregular Time Series ImagesSource quoteL283: Ours │ 0.966 │ 90.3 │ 87.0 │ 94.2 |
| 2024 | GLIM-Net | ACC (Accuracy) | 77.9% | Classification · resolution=256x256 | Multi-Scale Spatio-Temporal Transformer-Based Imbalanced Longitudinal Learning for Glaucoma Forecasting From Irregular Time Series ImagesSource quoteL281: GLIM-Net~\cite{xiaoyan:23:glim} │ 0.866 │ 77.9 │ 61.4 │ 85.8 |
| 2024 | CDOT baseline | Accuracy | 82.6 | Classification · intermediate-domains=2 | Enhancing Continuous Domain Adaptation with Multi-path Transfer CurriculumSource quoteL217: CDOT \cite{ortiz2019cdot} │ 82.6 │ 0.0209 │ 75.6 |
| 2024 | DA-MIDL baseline | ACC | 0.9085 | Classification · split: test | Connectional-style-guided contextual representation learning for brain disease diagnosisSource quoteL333: 0.9085 |
| 2024 | Naive baseline | ACC | 80 | Image Classification · split: val · setting=pooled data without pre/post processing · evaluation=5-fold cross-validation | Pooling Image Datasets with Multiple Covariate Shift and ImbalanceSource quoteL573: Naive │ 80{\scriptstyle(2.6)} │ 27{\scriptstyle(1.6)} │ 59{\scriptstyle(2.9)} │ 83{\scriptstyle(4.4)} │ 90{\scriptstyle(08.7)} │ 49{\scriptstyle(08.4)} |
| 2024 | Random Forest baseline | accuracy | 90% | Disease Diagnosis · split: test · test-repetitions=10 · train-test-split=70/30 | Intelligent Diagnosis of Alzheimer's Disease Based on Machine LearningSource quoteL206: Forest, and SVM, is ranked in descending order. XGBoost has the highest accuracy at 91%, followed by Random Forest at 90%, and SVM at 75%. Therefore, among these three algorithms, XGBoost has the highest accuracy and is the best diagnostic method for Alzheimer's disease. |
| 2024 | SVM baseline | accuracy | 75% | Disease Diagnosis · split: test · train-test-split=70/30 | Intelligent Diagnosis of Alzheimer's Disease Based on Machine LearningSource quoteL206: Forest, and SVM, is ranked in descending order. XGBoost has the highest accuracy at 91%, followed by Random Forest at 90%, and SVM at 75%. Therefore, among these three algorithms, XGBoost has the highest accuracy and is the best diagnostic method for Alzheimer's disease. |
| 2023 | Dynamic dual-graph fusion convolutional network (proposed model) proposed | ACC (accuracy) | 99.3% | Disease Classification · split: test · 5-fold-cross-validation · cohort=testing cohort · diagnostic-contrast=AD vs. NC | Dynamic Dual-Graph Fusion Convolutional Network for Alzheimer’s Disease DiagnosisSource quoteL196: ACC of 99.3% in the testing cohort. The results of our disease diagnosis method show an average improvement of 0.6% compared to the best comparison method (DGM) and an average improvement of 13.3% compared to the worst comparison method (SVM) in AD vs. NC task. |
| 2023 | Proposed transfer-learning and class-decomposition model (AlexNet feature extraction; ImageNet-pretrained VGG19 classifier) proposed | accuracy | 98.3% | Medical Image Classification · split: test · fine-tuned · cohort=134 subjects · backbone=VGG19 · pretraining=ImageNet · input-selection=20 highest-entropy 2D slices per subject | Transfer Learning and Class Decomposition for Detecting the Cognitive Decline of Alzheimer DiseaseSource quoteL269: In addition, we use the entropy-based approach to select the training dataset that contains the most informative data. We use the VGG19 ImageNet-trained weights network to obtain highly accurate results. We compared our findings to those of four other cutting-edge procedures using the ADNI dataset. With an accuracy of 98.3%, our model ternary classification outperforms the other approaches, representing a |
| 2023 | WSEK (weighted subspace exponential kernel) proposed | average classification accuracy | 79% | Classification · split: val · modality=fMRI · classifier=KSTM · rank-selection=best average over Tucker ranks 1–10 | A weighted subspace exponential kernel for support tensor machinesSource quoteL381: (79% for ADNI and 64% for ADHD) compared to other state of the art tensor kernels. We note that the accuracy of the subspace kernel improves for higher ranks in the ADHD dataset and is then similar to that of WSEK but this choice of rank is very high for a low-rank truncation method. On the other hand, our proposed kernel gives good classification accuracy already at rank 2. The Gaussian kernel was computed for different Tucker approximations of the full tensor. Using the full tensor in the computation of the kernel did not improve the accuracy. As in~\cite{KourJMLR}, the DuSK kernel was computed using a CP approximation of the full tensor (CP-DuSK), because computing the Tucker decomposition and then converting to CP yielded high CP ranks and DuSK was too slow. |
| 2023 | tLSSVM-MTL proposed | ACC | 98.17% | Classification · split: test · tasks=4 × 4 × 3 · kernel=RBF · training-sample-ratio=0.3 | Low-Rank Multitask Learning based on Tensorized SVMs and LSSVMsSource quoteL743: tLSSVM-MTL │ 98.17% │ 97.85% │ 98.48% │ 98.16%\% │ 5.31 |
| 2023 | 2D-Slice-CNN with pretrained ResNet-18 encoder proposed | balanced accuracy | 88.6 | Alzheimer Disease Classification · backbone=ResNet-18 · pretraining=ImageNet · slice-direction=axial | Transferring Models Trained on Natural Images to 3D MRI via Position Encoded Slice ModelsSource quoteL152: Our main goal with these experiments is to demonstrate improvement in performance due to natural image pretraining. Nevertheless, another interesting outcome is that 2D-Slice models with pretrained encoders are the best for both tasks, outperforming the 3D-CNN as well. For the AD task, we observe that 3D-CNN has a balanced accuracy of 88.40. In contrast, models with pretrained ResNet-18 encoder model have a balanced accuracy of 88.6 when using slices along the axial direction (both with and without position encodings). Similarly, the best MAE with the pretrained model for brain age prediction is 2.715 compared to 2.792 MAE with 3D-CNN. Finally, We also evaluated if increasing the size of the pretrained encoder may lead to more gain by employing ResNet-50 as the encoder for brain age prediction. |
| 2023 | CvFormer with self-supervised pretraining proposed | Accuracy | 89.09% | Disease Classification · split: test · pretraining=self-supervised | CvFormer: Cross-view transFormers with pre-training for fMRI analysis of human brainSource quoteL192: \checkmark │ 89.09 │ 87.35 |
| 2023 | CvFormer without self-supervised pretraining ablation | Accuracy | 83.23% | Disease Classification · split: test · pretraining=none | CvFormer: Cross-view transFormers with pre-training for fMRI analysis of human brainSource quoteL193: × │ 83.23 │ 82.78 |
| 2023 | GPT-4 (0-shot) baseline | Accuracy | 0.820 | Dementia Diagnosis · 0-shot | Can LLMs like GPT-4 outperform traditional AI tools in dementia diagnosis? Maybe, but not todaySource quoteL139: ADNI │ 0.820 │ 0.820 │ 0.443 │ 0.639 │ 0.803 │ 0.689 │ 0.803 │ 0.820 │ 0.852 |
| 2023 | RRL baseline | Accuracy | 0.852 | Dementia Diagnosis · supervised | Can LLMs like GPT-4 outperform traditional AI tools in dementia diagnosis? Maybe, but not todaySource quoteL139: ADNI │ 0.820 │ 0.820 │ 0.443 │ 0.639 │ 0.803 │ 0.689 │ 0.803 │ 0.820 │ 0.852 |
| 2023 | MTL-LSSVM baseline | ACC | 95.42% | Classification · split: test · tasks=4 × 4 × 3 · kernel=RBF · training-sample-ratio=0.3 | Low-Rank Multitask Learning based on Tensorized SVMs and LSSVMsSource quoteL741: MTL-LSSVM │ 95.42% │ 94.61% │ 96.24% │ 95.42% \% │ 0.23 |
| 2023 | 3D-CNN baseline | accuracy | 88.40 | Alzheimer Disease Classification | Transferring Models Trained on Natural Images to 3D MRI via Position Encoded Slice ModelsSource quoteL143: Tables~\ref{tab:adni_results} and~\ref{tab:brain_age_results} summarize the performance of different models for AD and brain age prediction, respectively. We observed that the 2D-Slice-CNN was better at predicting brain age when using the same hyperparameters as~\cite{gupta2021improved}. However, our 3D-CNN results are better than 2D-Slice-CNN (Table~\ref{tab:brain_age_results}), and the reported numbers in~\cite{gupta2021improved} (3.02 vs.\ 2.792 MAE) due to switching from PyTorch's default initialization to explicitly using He initialization~\cite{he2015delving} and using \texttt{SGD}\ optimizer. Similarly, 3D-CNN outperforms the 2D-Slice-CNN for AD prediction (88.40 vs.\ 87.53 accuracy). We hypothesized that this might be due to 2D-Slice-CNN combining slice embeddings with permutation invariant operation and consequently losing information about the position of the slice in MRI. We, thus, incorporate positional encodings in the 2D-Slice model. |
| 2023 | 3D-CNN baseline | balanced accuracy | 88.40 | Alzheimer Disease Classification | Transferring Models Trained on Natural Images to 3D MRI via Position Encoded Slice ModelsSource quoteL152: Our main goal with these experiments is to demonstrate improvement in performance due to natural image pretraining. Nevertheless, another interesting outcome is that 2D-Slice models with pretrained encoders are the best for both tasks, outperforming the 3D-CNN as well. For the AD task, we observe that 3D-CNN has a balanced accuracy of 88.40. In contrast, models with pretrained ResNet-18 encoder model have a balanced accuracy of 88.6 when using slices along the axial direction (both with and without position encodings). Similarly, the best MAE with the pretrained model for brain age prediction is 2.715 compared to 2.792 MAE with 3D-CNN. Finally, We also evaluated if increasing the size of the pretrained encoder may lead to more gain by employing ResNet-50 as the encoder for brain age prediction. |
| 2022 | DCA-CRN (proposed) proposed | ACC (accuracy) | 69.6% | Multi Class Classification · classes=AD, lMCI, eMCI, NC | Reconstructing high-order sequence features of dynamic functional connectivity networks based on diversified covert attention patterns for Alzheimer's disease classificationSource quoteL194: ~DCA-CRN(OURS) │ 69.6 │ 64.7 │ 78.1 │ 65.0 │ 66.7 |
| 2022 | BrainFormer (fMRI-only) proposed | classification accuracy | 95.3% | Brain Disease Classification · split: val · 5-fold-cross-validation · input=single-volume fMRI · classes=AD vs CN | First Glance Diagnosis: Brain Disease Classification with Single fMRI VolumeSource quoteL337: fMRI │ 97.2 │ 95.3 │ 72.0 │ 72.5 │ 81.2 |
| 2022 | Proposed layer-wise partitioning and merging proposed | ACC (accuracy) | 0.94 | Binary Classification · gpus=1 · model=3D-ResAttNet34 · comparison=AD vs. NC | Layer-wise partitioning and merging for efficient and scalable deep learningSource quoteL234: 1 │ 0.79 │ 29 │ 0.93 │ 55 │ 0.81 │ 34 │ 0.94 │ 61\tabularnewline |
| 2022 | Proposed layer-wise partitioning and merging proposed | ACC (accuracy) | 0.94 | Binary Classification · gpus=8 · model=3D-ResAttNet34 · comparison=AD vs. NC | Layer-wise partitioning and merging for efficient and scalable deep learningSource quoteL241: 8 │ 0.80 │ 3 │ 0.93 │ 7 │ 0.82 │ 4 │ 0.94 │ 8 \tabularnewline |
| 2022 | CRN ablation | ACC (accuracy) | 67.4% | Multi Class Classification · classes=AD, lMCI, eMCI, NC | Reconstructing high-order sequence features of dynamic functional connectivity networks based on diversified covert attention patterns for Alzheimer's disease classificationSource quoteL190: ~CRN │ 67.4 │ 52.7 │ 74.8 │ 64.0 │ 66.7 |
| 2022 | ETLN^E (ECN-only) | ACC (prediction accuracy) | 73.47 | Classification · split: val | A Structure-Guided Effective and Temporal-Lag Connectivity Network for Revealing Brain Disorder MechanismsSource quoteL175: ETLN (E) │ 74.31 │ 70.59 │ 77.59 │ 72.00 │ 78.02 │ 82.35 │ 72.50 │ 80.77 │ 73.47 │ 82.76 │ 60.00 │ 78.69 |
| 2022 | LR | ACC (prediction accuracy) | 67.35 | Classification · split: val | A Structure-Guided Effective and Temporal-Lag Connectivity Network for Revealing Brain Disorder MechanismsSource quoteL169: LR │ 69.72 │ 66.67 │ 72.41 │ 67.33 │ 74.73 │ 80.39 │ 67.50 │ 78.10 │ 67.35 │ 75.86 │ 55.00 │ 73.33 |
| 2021 | HGGAN-proposed multimodal connectivity matrix (MC), evaluated with GCN proposed | ACC | 93.02 | Disease Classification · split: test · classifier=GCN · train-test-split=65/35 · random-initializations=5 | Characterization Multimodal Connectivity of Brain Network by Hypergraph GAN for Alzheimer's Disease AnalysisSource quoteL190: \quad │ MC(Ours) │ 93.02 │ 94.11 │ 92.30 │ 90.24 │ 82.35 │ 88.46 │ 72.00 │ 82.35 │ 50.00 |
| 2021 | HGGAN-proposed multimodal connectivity matrix (MC), evaluated with GCN proposed | ACC | 90.24 | Disease Classification · split: test · classifier=GCN · train-test-split=65/35 · random-initializations=5 | Characterization Multimodal Connectivity of Brain Network by Hypergraph GAN for Alzheimer's Disease AnalysisSource quoteL190: \quad │ MC(Ours) │ 93.02 │ 94.11 │ 92.30 │ 90.24 │ 82.35 │ 88.46 │ 72.00 │ 82.35 │ 50.00 |
| 2021 | HGGAN-proposed multimodal connectivity matrix (MC), evaluated with GCN proposed | ACC | 72.00 | Disease Classification · split: test · classifier=GCN · train-test-split=65/35 · random-initializations=5 | Characterization Multimodal Connectivity of Brain Network by Hypergraph GAN for Alzheimer's Disease AnalysisSource quoteL190: \quad │ MC(Ours) │ 93.02 │ 94.11 │ 92.30 │ 90.24 │ 82.35 │ 88.46 │ 72.00 │ 82.35 │ 50.00 |
| 2021 | HGGAN-proposed multimodal connectivity matrix (MC), evaluated with GCN proposed | ACC | 80.00 | Disease Classification · split: test · classifier=GCN · train-test-split=65/35 · random-initializations=5 | Characterization Multimodal Connectivity of Brain Network by Hypergraph GAN for Alzheimer's Disease AnalysisSource quoteL217: \quad │ MC(Ours) │ 80.00 │ 79.16 │ 80.76 │ 91.17 │ 87.50 │ 92.30 │ 90.62 │ 91.66 │ 87.50 |
| 2021 | HGGAN-proposed multimodal connectivity matrix (MC), evaluated with GCN proposed | ACC | 91.17 | Disease Classification · split: test · classifier=GCN · train-test-split=65/35 · random-initializations=5 | Characterization Multimodal Connectivity of Brain Network by Hypergraph GAN for Alzheimer's Disease AnalysisSource quoteL217: \quad │ MC(Ours) │ 80.00 │ 79.16 │ 80.76 │ 91.17 │ 87.50 │ 92.30 │ 90.62 │ 91.66 │ 87.50 |
| 2021 | HGGAN-proposed multimodal connectivity matrix (MC), evaluated with GCN proposed | ACC | 90.62 | Disease Classification · split: test · classifier=GCN · train-test-split=65/35 · random-initializations=5 | Characterization Multimodal Connectivity of Brain Network by Hypergraph GAN for Alzheimer's Disease AnalysisSource quoteL217: \quad │ MC(Ours) │ 80.00 │ 79.16 │ 80.76 │ 91.17 │ 87.50 │ 92.30 │ 90.62 │ 91.66 │ 87.50 |
| 2021 | DecGAN (t=2, k=5) proposed non-standard slice | ACC | 92.59% | Binary Classification · split: val · k=5 · t=2 · classes=AD vs NC · validation=five-fold | DecGAN: Decoupling Generative Adversarial Network detecting abnormal neural circuits for Alzheimer's diseaseSource quoteL354: The top two highest ACC value of 92.59% and 88.90% are achieved at (t,k)=(2,5) and (t,k)=(1,8). |
| 2021 | DecGAN (t=1, k=8) proposed non-standard slice | ACC | 88.90% | Binary Classification · split: val · k=8 · t=1 · classes=AD vs NC · validation=five-fold | DecGAN: Decoupling Generative Adversarial Network detecting abnormal neural circuits for Alzheimer's diseaseSource quoteL354: The top two highest ACC value of 92.59% and 88.90% are achieved at (t,k)=(2,5) and (t,k)=(1,8). |
| 2021 | WDPN proposed non-standard slice | Balanced accuracy | 0.942 | Alzheimer Diagnosis · split: test · data=ADNI visits · subset=mild cognitive impairment patients excluded · split unit=subject | Scalable, Axiomatic Explanations of Deep Alzheimer's Diagnosis from Heterogeneous DataSource quoteL500: The WDPN achieves a balanced accuracy of 0.942 on the test data. |
| 2021 | FedNI proposed | Accuracy | 0.758 | Disease Prediction · split: val · semi-supervised · evaluation=5-fold cross-validation repeated 5 times · institutions=5 · labeled-rate=80% | FedNI: Federated Graph Learning with Network Inpainting for Population-Based Disease PredictionSource quoteL446: ~~\multirow{2}{*}{\textbf{\texttt{FedNI}} (ours)} │ 0.667 │ 0.663 │ 0.647 │ 0.640 │ 0.637 │ 0.758 │ 0.754 │ 0.725 │ 0.721 │ 0.717 |
| 2021 | DeepFM proposed | median balanced accuracy | 0.589 | Alzheimer Disease Classification · split: test · evaluation=five-fold | Alzheimer's Disease Diagnosis via Deep Factorization Machine ModelsSource quoteL284: With a median balanced accuracy of 0.589, DeepFM has the highest performance of all models (see fig.~\ref{fig:BalancedAcc}). It is slightly better than DNN (\text{acc}-med = 0.582) and FM (\text{acc}-med = 0.581). DeepFM improves over the DNN thanks to the added FM model. Solely the linear model is unable to achieve similar performance. This shows the effectiveness of the FM approach and its capability to |
| 2021 | DeepFM with meta-embeddings (DeepFM-Meta) proposed | balanced accuracy | 0.596 | Alzheimer Disease Classification · split: test · evaluation=five-fold · feature-setting=brain-volume meta-embeddings | Alzheimer's Disease Diagnosis via Deep Factorization Machine ModelsSource quoteL289: Our results demonstrate that this leads to a slightly higher balanced accuracy of 0.596, but most importantly lowers the variance across folds (fig.~\ref{fig:BalancedAcc}, right). |
| 2021 | Transferred model proposed | AD classification accuracy | 97.10% | Alzheimer Disease Classification · transfer-learning · age-group=>80 | Embracing the disharmony in medical imaging: A Simple and effective framework for domain adaptationSource quoteL487: on age group >80 achieved 97.10% accuracy in AD classification. |
| 2021 | Our approach, 3D-ResAttNet34 (parallel) proposed | Accuracy | 0.97 | Medical Image Classification · backbone=3D-ResAttNet34 · parallelism=parallel | A Hybrid Parallelization Approach for Distributed and Scalable Deep LearningSource quoteL398: Our approach │ 3D-ResAttNet34 │ Yes │ 0.84 │ 0.97 |
| 2021 | Our approach, 3D-ResAttNet34 (parallel) proposed | Accuracy | 0.84 | Medical Image Classification · backbone=3D-ResAttNet34 · parallelism=parallel | A Hybrid Parallelization Approach for Distributed and Scalable Deep LearningSource quoteL398: Our approach │ 3D-ResAttNet34 │ Yes │ 0.84 │ 0.97 |
| 2021 | Proposed 2D-DCNN proposed non-standard slice | accuracy | 99.89% | Medical Image Classification · split: test · input=2D images from structural MRI · epochs=70 · classes=3 (AD/MCI/NC) · train-validation-test-split=60%-20%-20% | Deep Convolutional Neural Network based Classification of Alzheimer's Disease using MRI dataSource quoteL205: 99.89% which is superior to other state-of-the-art techniques presented in literature. However, most of the studies used a combination of features from different modalities, while the proposed method is more suitable for time-saving with single modality and low-level pre-processing. The results presented in the form of confusion matrix, the loss values, and accuracy are shown in Figures 3, 4, and 5 respectively. Table II shows the comparison results of previous studies with the proposed framework. The confusion matrix and ROC curve on training, testing, and validation data demonstrate the effectiveness of this model. This paper serves as a further stimulus for utilizing different deep learning-based models for the analysis of 3D |
| 2021 | DNN ablation | median balanced accuracy | 0.582 | Alzheimer Disease Classification · split: test · evaluation=five-fold | Alzheimer's Disease Diagnosis via Deep Factorization Machine ModelsSource quoteL284: With a median balanced accuracy of 0.589, DeepFM has the highest performance of all models (see fig.~\ref{fig:BalancedAcc}). It is slightly better than DNN (\text{acc}-med = 0.582) and FM (\text{acc}-med = 0.581). DeepFM improves over the DNN thanks to the added FM model. Solely the linear model is unable to achieve similar performance. This shows the effectiveness of the FM approach and its capability to |
| 2021 | FM ablation | median balanced accuracy | 0.581 | Alzheimer Disease Classification · split: test · evaluation=five-fold | Alzheimer's Disease Diagnosis via Deep Factorization Machine ModelsSource quoteL284: With a median balanced accuracy of 0.589, DeepFM has the highest performance of all models (see fig.~\ref{fig:BalancedAcc}). It is slightly better than DNN (\text{acc}-med = 0.582) and FM (\text{acc}-med = 0.581). DeepFM improves over the DNN thanks to the added FM model. Solely the linear model is unable to achieve similar performance. This shows the effectiveness of the FM approach and its capability to |
| 2021 | SVM on priori brain networks baseline non-standard slice | ACC | 77.77% | Binary Classification · split: val · input=priori brain networks · classes=NC vs AD · classifier=SVM · validation=five-fold | DecGAN: Decoupling Generative Adversarial Network detecting abnormal neural circuits for Alzheimer's diseaseSource quoteL457: SVM │ Priori brain networks │ 72.41% │ 73.33% │ 71.42% │ 73.33% │ 76.19% │ 86.66% │ 50.00% │ 83.87% │ 77.77% │ 87.50% │ 63.63% │ 82.35% |
| 2021 | SVM on reconstruction brain networks baseline non-standard slice | ACC | 85.18% | Binary Classification · split: val · input=DecGAN reconstruction brain networks · classes=NC vs AD · classifier=SVM · validation=five-fold | DecGAN: Decoupling Generative Adversarial Network detecting abnormal neural circuits for Alzheimer's diseaseSource quoteL458: Reconstruction brain networks │ 75.86% │ 80.00% │ 71.42% │ 77.41% │ 80.95% │ 86.66% │ 66.66% │ 86.66% │ 85.18% │ 75.00% │ 100.00% │ 85.71% |
| 2021 | GCN on priori brain networks baseline non-standard slice | ACC | 82.75% | Binary Classification · split: val · input=priori brain networks · classes=NC vs EMCI · classifier=GCN · validation=five-fold | DecGAN: Decoupling Generative Adversarial Network detecting abnormal neural circuits for Alzheimer's diseaseSource quoteL463: GCN │ Priori brain networks │ 82.75% │ 86.66% │ 78.57% │ 83.87% │ 80.95% │ 73.33% │ 100.00% │ 84.61% │ 81.48% │ 81.25% │ 81.80% │ 83.87% |
| 2021 | GCN on reconstruction brain networks baseline non-standard slice | ACC | 86.20% | Binary Classification · split: val · input=DecGAN reconstruction brain networks · classes=NC vs EMCI · classifier=GCN · validation=five-fold | DecGAN: Decoupling Generative Adversarial Network detecting abnormal neural circuits for Alzheimer's diseaseSource quoteL464: Reconstruction brain networks │ 86.20% │ 86.66% │ 85.71% │ 86.66% │ 85.71% │ 80.00% │ 100.00% │ 88.88% │ 85.18% │ 81.25% │ 90.91% │ 86.66% |
| 2021 | FedSage+ baseline | Accuracy | 0.751 | Disease Prediction · split: val · semi-supervised · evaluation=5-fold cross-validation repeated 5 times · institutions=5 · labeled-rate=80% | FedNI: Federated Graph Learning with Network Inpainting for Population-Based Disease PredictionSource quoteL443: ~~\multirow{2}{*}{FedSage+} │ 0.658 │ 0.655 │ 0.641 │ 0.627 │ 0.626 │ 0.751 │ 0.744 │ 0.722 │ 0.699 │ 0.700 |
| 2021 | Reported AD classifier (baseline preceding transfer-learning result) baseline | AD classification accuracy | 88.62% | Alzheimer Disease Classification · age-group=>80 | Embracing the disharmony in medical imaging: A Simple and effective framework for domain adaptationSource quoteL485: 88.62% for >80 age group. Biases from such data inequalities among age |
| 2021 | SpiralNet++ baseline | accuracy (Acc) | 77.3% | Disease Classification · split: test · input=mesh · cohort=282 AD patients and 282 healthy controls · anatomy=left hippocampus · template-based=true · train-test-split=50/50 | Geometric Deep Learning on Anatomical Meshes for the Prediction of Alzheimer's DiseaseSource quoteL98: SpiralNet++ │ Mesh │ \ding{51} │ 77.3 │ 0.78 │ 0.77 │ 85K |
| 2021 | CoME baseline | accuracy (Acc) | 77.0% | Disease Classification · split: test · input=mesh · cohort=282 AD patients and 282 healthy controls · anatomy=left hippocampus · template-based=true · train-test-split=50/50 | Geometric Deep Learning on Anatomical Meshes for the Prediction of Alzheimer's DiseaseSource quoteL97: CoME │ Mesh │ \ding{51} │ 77.0 │ 0.75 │ 0.80 │ 44K |
| 2021 | PointNet baseline | accuracy (Acc) | 73.5% | Disease Classification · split: test · input=point-cloud · cohort=282 AD patients and 282 healthy controls · anatomy=left hippocampus · train-test-split=50/50 | Geometric Deep Learning on Anatomical Meshes for the Prediction of Alzheimer's DiseaseSource quoteL94: PointNet │ \ding{55} │ 73.5 │ 0.74 │ 0.72 │ 1600K |
| 2021 | Zhang et al., 3D-ResAttNet34 (non-parallel) baseline | Accuracy | 0.97 | Medical Image Classification · backbone=3D-ResAttNet34 · parallelism=non-parallel | A Hybrid Parallelization Approach for Distributed and Scalable Deep LearningSource quoteL397: Zhang et al.\cite{Xingye} │ 3D-ResAttNet34 │ No │ 0.84 │ 0.97 |
| 2021 | Zhang et al., 3D-ResAttNet34 (non-parallel) baseline | Accuracy | 0.84 | Medical Image Classification · backbone=3D-ResAttNet34 · parallelism=non-parallel | A Hybrid Parallelization Approach for Distributed and Scalable Deep LearningSource quoteL397: Zhang et al.\cite{Xingye} │ 3D-ResAttNet34 │ No │ 0.84 │ 0.97 |
| 2021 | Alex Net baseline non-standard slice | accuracy | 98.97% | Medical Image Classification · split: test · input=2D images from structural MRI · epochs=70 · classes=3 (AD/MCI/NC) · train-validation-test-split=60%-20%-20% | Deep Convolutional Neural Network based Classification of Alzheimer's Disease using MRI dataSource quoteL204: The optimal learning rate is selected to calculate gradient per epoch during backpropagation operation. There are multiple subsets to select hyper-parameters for any neural network. The model has better features detection to classify larger datasets. Our target is to classify AD stages on imbalanced data, and we have successfully achieved it with the accuracy of 98.97% and 99.31% on Alex Net and VGG16 respectively. Whereas, the proposed model, with a small number of layers than VGG, benefits the training time and computational burden, performs best in terms of accuracy of |
| 2021 | VGG16 baseline non-standard slice | accuracy | 99.31% | Medical Image Classification · split: test · input=2D images from structural MRI · epochs=70 · classes=3 (AD/MCI/NC) · train-validation-test-split=60%-20%-20% | Deep Convolutional Neural Network based Classification of Alzheimer's Disease using MRI dataSource quoteL204: The optimal learning rate is selected to calculate gradient per epoch during backpropagation operation. There are multiple subsets to select hyper-parameters for any neural network. The model has better features detection to classify larger datasets. Our target is to classify AD stages on imbalanced data, and we have successfully achieved it with the accuracy of 98.97% and 99.31% on Alex Net and VGG16 respectively. Whereas, the proposed model, with a small number of layers than VGG, benefits the training time and computational burden, performs best in terms of accuracy of |
| 2020 | TT-MMK proposed | Average classification accuracy | 73% | Classification · split: val · 5-fold-cross-validation · data=resting-state fMRI · classes=AD+MCI vs normal controls · subjects=33 · repetitions=50 | Efficient Structure-preserving Support Tensor Train MachineSource quoteL515: TT-MMK │ 73 │ 64 │ 99 │ 99 |
| 2020 | DOP (depth-first-based ordinal pattern kernel) proposed | Classification accuracy | 86.90% | Brain Network Classification · split: val · atlas=AAL-90 · validation=leave-one-out · diagnosis-contrast=AD-vs-NC | Ordinal Pattern Kernel for Brain Connectivity Network ClassificationSource quoteL216: DOP │ 81.21 │ 86.90 │ 83.84 │ 80.0 │ 83.12 } |
| 2020 | DOP (depth-first-based ordinal pattern kernel) proposed | Classification accuracy | 83.84% | Brain Network Classification · split: val · atlas=AAL-90 · validation=leave-one-out · diagnosis-contrast=EMCI-vs-LMCI | Ordinal Pattern Kernel for Brain Connectivity Network ClassificationSource quoteL216: DOP │ 81.21 │ 86.90 │ 83.84 │ 80.0 │ 83.12 } |
| 2020 | DOP (depth-first-based ordinal pattern kernel) proposed | Classification accuracy | 80.0% | Brain Network Classification · split: val · atlas=AAL-90 · validation=leave-one-out · diagnosis-contrast=EMCI-vs-AD | Ordinal Pattern Kernel for Brain Connectivity Network ClassificationSource quoteL216: DOP │ 81.21 │ 86.90 │ 83.84 │ 80.0 │ 83.12 } |
| 2020 | DOP (depth-first-based ordinal pattern kernel) proposed | Classification accuracy | 83.12% | Brain Network Classification · split: val · atlas=AAL-90 · validation=leave-one-out · diagnosis-contrast=LMCI-vs-AD | Ordinal Pattern Kernel for Brain Connectivity Network ClassificationSource quoteL216: DOP │ 81.21 │ 86.90 │ 83.84 │ 80.0 │ 83.12 } |
| 2020 | PIF-B proposed non-standard slice | balanced accuracy (Bal. acc.) | 84.83% | Disease Classification · subset=large data set; all images | Harnessing spatial homogeneity of neuroimaging data: patch individual filter layers for CNNsSource quoteL135: ADNI │ PIF-B │ 84.83% (1.65) │ 21.3 │ 79.47% (2.23) │ 73.1 |
| 2020 | Skip-connection U-Net-based AD-versus-NC classifier (MeDaS case study) | accuracy average | 0.95 | Binary Classification · model=skip-connection U-Net · classes=AD vs NC | MeDaS: An open-source platform as service to help break the walls between medicine and informaticsSource quoteL487: The network is trained on MeDaS with the default parameters. A skip-connection version employs the AD vs NC classification. The accuracy average for the classification task is 0.95. |
| 2020 | Improved MMK baseline | Average classification accuracy | 71% | Classification · split: val · 5-fold-cross-validation · data=resting-state fMRI · classes=AD+MCI vs normal controls · subjects=33 · repetitions=50 | Efficient Structure-preserving Support Tensor Train MachineSource quoteL514: Improved MMK │ 71 │ 61 │ 94 │ 98 |
| 2020 | PM (Pyramid Match kernel) baseline | Classification accuracy | 79.87% | Brain Network Classification · split: val · atlas=AAL-90 · validation=leave-one-out · diagnosis-contrast=MCI-vs-NC | Ordinal Pattern Kernel for Brain Connectivity Network ClassificationSource quoteL212: PM │ 79.87 │ 72.62 │ 75.76 │ 74.44 │ 75.32 |
| 2020 | Baseline-B baseline non-standard slice | balanced accuracy (Bal. acc.) | 83.60% | Disease Classification · subset=large data set; all images | Harnessing spatial homogeneity of neuroimaging data: patch individual filter layers for CNNsSource quoteL134: ADNI │ Baseline-B │ 83.60% (4.50) │ 34.2 │ 79.71% (3.23) │ 106.8 |
| 2019 | MGNN (proposed multi-resolution graph neural network) proposed | Accuracy | 0.774 | Alzheimer Disease Classification · split: val · 3-fold-cross-validation · classes=2 · selection=best results across multiple settings · class-grouping=pre-clinical AD (CN+EMCI) vs prodromal AD (LMCI+AD) | Learning Multi-resolution Graph Edge Embedding for Discovering Brain Network Dysfunction in Neurological DisordersSource quoteL1081: MGNN (ours) │ {\bf 0.774} │ {\bf 0.772} │ {\bf 0.774} |
| 2019 | FLARe proposed | Accuracy | .659 | Disease Stage Forecasting · patients=1652 · batch-loading=random | FLARe: Forecasting by Learning Anticipated RepresentationsSource quoteL123: FLARe │ .659 │ .670 │ .660 │ .665 |
| 2019 | STOR_I proposed | accuracy | 0.493 | Age Group Classification · split: test · setting=global · age-group=50-59 | Tackling ordinal regression problem for heterogeneous data: sparse and deep multi-task learning approachesSource quoteL349: \multirow{2}[2]{*} {50-59} │ \multirow{2}[2]{*}{72} │ \bf0.791 │ 0.783 │ 0.572 │ 0.522 │ 0.493 │ 0.489 │ 0.554 │ 0.633 │ 0.473 │ 0.459 \%\bigstrut[t] |
| 2019 | Linear SVM using morphological age and disease score proposed | Mean classification accuracy | 0.59 | Classification · split: val · classes=MCI stable vs MCI converters · classifier=linear SVM · validation=10-fold cross-validation | A model of brain morphological changes related to aging and Alzheimer's disease from cross-sectional assessmentsSource quoteL291: We also perform a simple linear classification task between the MCIs and MCIc groups using this two cross-sectional markers. A SVM linear classifier is fitted to the full data-set to perform the binary classification\footnote{The classification task was performed using the SVC module of the scikit-learn python library~\citep{scikit-learn}}. The error penalty weights are adjusted between the two classes to balance the trade-off between false positive and false negative rate. The mean classification accuracy using a 10-folds cross-validation scheme is equal to 0.59. The linear decision function is equivalent to the projection on the SVF v_A - 0.003 v_D, so the differences between MCIs and MCIc subjects is, in our model, only associated with the aging trajectory while the disease specific changes do not seem to have an impact before the conversion. For comparison, for the same experiment between CN and AD, the linear classifier corresponds to the projection on v_A + 0.49 v_D so approximately (v-bn + v-ad) / 2, i.e. the mean evolution of the whole population. Of course, in both cases we do not reach the performance of state-of-the-art dedicated algorithm but it allows us to see how both markers are associated with the diagnosis. Moreover this discriminant approach could be extended by using information in a subset of targeted areas. |
| 2019 | RNN-Concat baseline | Accuracy | .603 | Disease Stage Forecasting · patients=1652 · batch-loading=random | FLARe: Forecasting by Learning Anticipated RepresentationsSource quoteL122: RNN-Concat │ .603 │ .607 │ .610 │ .609 |
| 2019 | pre-trained ResNet-50 baseline | prediction accuracy | 95% | Medical Image Classification · backbone=ResNet-50 · classes=MCI-vs-NC · modality=PET · pretraining=pre-trained | Predicting Alzheimer's Disease by Hierarchical Graph Convolution from Positron Emission Tomography ImagingSource quoteL54: From the performance comparison in Table 1 “2-Classes” (i.e. MCI/NC) column, it can be observed that PETNet can achieve same-level performance with state-of-art pre-trained ResNet-50 method, where similar prediction accuracy for other dataset using ResNet-50 has been reported in \cite{b16}. It should be noted that without pre-training, performance of image-based deep learning decreased significantly (from 95% down to 83%, p<0.01 for 10 experiments) because of the lack of samples to fully train such a complex model (50 layers). In contrast, PETNet uses much less number of mode parameters (5 layers in total), does not need pre-train, and uses much shorter time for training. Further, PETNet using empty/random graph results in lowered performance as well as unstable training process, as also illustrated by the learning curve in ~\ref{fig:Fig3}. |
| 2019 | ResNet-50 without pre-training baseline | prediction accuracy | 83% | Medical Image Classification · backbone=ResNet-50 · classes=MCI-vs-NC · modality=PET · pretraining=none | Predicting Alzheimer's Disease by Hierarchical Graph Convolution from Positron Emission Tomography ImagingSource quoteL54: From the performance comparison in Table 1 “2-Classes” (i.e. MCI/NC) column, it can be observed that PETNet can achieve same-level performance with state-of-art pre-trained ResNet-50 method, where similar prediction accuracy for other dataset using ResNet-50 has been reported in \cite{b16}. It should be noted that without pre-training, performance of image-based deep learning decreased significantly (from 95% down to 83%, p<0.01 for 10 experiments) because of the lack of samples to fully train such a complex model (50 layers). In contrast, PETNet uses much less number of mode parameters (5 layers in total), does not need pre-train, and uses much shorter time for training. Further, PETNet using empty/random graph results in lowered performance as well as unstable training process, as also illustrated by the learning curve in ~\ref{fig:Fig3}. |
| 2018 | CNN (MRI-only) proposed non-standard slice | Accuracy | 92% | Classification · split: test · subset=1,299 scans · modality=MRI | Neuroimaging modality fusion in Alzheimer’s classification using convolutional neural networksSource quoteL80: MRI │ 92% |
| 2018 | CNN (PET-only) proposed non-standard slice | Accuracy | 85% | Classification · split: test · subset=585 scans · modality=amyloid PET | Neuroimaging modality fusion in Alzheimer’s classification using convolutional neural networksSource quoteL81: PET │ 85% |
| 2018 | CNN (MRI+PET fusion) proposed non-standard slice | Accuracy | 94% | Classification · split: test · subset=585 paired data points · modality=MRI+amyloid PET fusion | Neuroimaging modality fusion in Alzheimer’s classification using convolutional neural networksSource quoteL82: Fusion │ 94% |
| 2018 | Proposed end-to-end 3D-CNN proposed | Acc% | 94.1% | Binary Classification · modality=MRI | End-To-End Alzheimer's Disease Diagnosis and Biomarker IdentificationSource quoteL119: Ours │ MRI │ 94.1 │ 0.94 │ 0.91 |
| 2018 | PIMMS modality classifier proposed | Classification accuracy | 88% | Modality Classification · split: test · setting=supervised · protocol=unseen | PIMMS: Permutation Invariant Multi-Modal SegmentationSource quoteL147: For the mixed holdout it was found that the classification accuracy was 99% between all three modalities. For unseen protocols the accuracy was lower, 88% for ADNI and 87% for MICCAI17 which showed that the inter-scanner variance was harder to model than the inter-subject variance. |