ADNI · Classification

202 papers · 607 extracted observations · classification · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Classification.

46.963.580.196.7201220192026QDA: 66.14 (2012)QDA: 68.0 (2012)TabSeq: 64.44 (2024)TabSeq: 75.13 (2024)GLIM-Net: 77.9 (2024)MST-former (3 scales): 90.3 (2024)ConnectomeDiffuser: 71.25 (2025)MedOrch: 50.35 (2025)MedOrch (o1-mini, best@5): 93.26 (2025)M3D + LGA: 76.7 (2025)RCL: 89.3 (2025)Reinforced Domain Selection: 90.5 (2025)Artemis: 84.3 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 58 of 58 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026OctEncoder proposedACC0.782Classification · comparison=MCI vs CN · representation=tetrahedral meshHierarchical Mesh Transformers with Topology-Guided Pretraining for Morphometric Analysis of Brain Structures
Source quote
L135: OctEncoder │ 0.907 │ 0.902 │ 0.914 │ 0.731 │ 0.650 │ 0.812 │ 0.782 │ 0.761 │ 0.807 │ 0.763 │ 0.751 │ 0.774
2026Artemis proposedaccuracy84.3%Classification · classes=NC vs. MCIArtemis: Anatomy-Resolved inTervention for Eliminating Multimodal NeuroImage confounderS
Source quote
L278: On ADNI, Artemis achieves 84.3% accuracy, a +5.0% absolute improvement over the best baseline BrainNetCNN (79.3%), and a macro-F1 of 73.5% compared with BrainNetCNN's 52.4%, a +21.1 percentage-point gain that reflects far more balanced recall across the NC and MCI classes.
2026DeCI proposedAccuracy+11.25 ppClassification · split: testMoving Beyond Functional Connectivity: Time-Series Modeling for fMRI-Based Brain Disorder Classification
Source quote
L257: Paired two-sided t-tests on the 5-fold results (Table~\ref{tab:significance}) show that DeCI significantly outperforms Leddam. On ADNI, DeCI improves Accuracy by +11.25\,pp \([8.24, 14.28]\), d_z=4.63, and F1-Score by +22.13\,pp \([13.92, 30.33]\), d_z=3.35 (both p<0.001). On Mātai, Accuracy and F1-Score improve by +3.34\,pp \([0.35, 6.31]\), d_z=1.39, and +4.04\,pp \([0.32, 7.76]\), d_z=1.35 (both p<0.05). On Neurocon, DeCI yields +4.11\,pp in Accuracy \([0.75, 7.47]\), d_z=1.81, and +2.66\,pp in F1-Score \([0.18, 5.14]\), d_z=1.33 (both p<0.05). On TaoWu, DeCI yields +11.50\,pp in Accuracy \([7.96, 15.04]\), d_z=4.03, and +13.83\,pp in F1-Score \([9.71, 17.93]\), d_z=4.17 (both p<0.001). With n{=}5 folds, d_z>1.2 denotes strong, stable improvements, met on Neurocon and Mātai and vastly exceeded on ADNI and TaoWu, highlighting DeCI’s effectiveness and robustness against overfitting on small sample datasets (e.g., Neurocon and TaoWu).
2026MM-KG multimodal patient representation (clinical history, biomarkers, and imaging) proposedbalanced accuracy0.652ClassificationAligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMs
Source quote
L873: history improves prognosis balanced accuracy from 0.595 to 0.652 (App. L). Removing PrimeKG leaves
2026ChebyNet baselineACC0.735Classification · comparison=MCI vs CN · representation=tetrahedral meshHierarchical Mesh Transformers with Topology-Guided Pretraining for Morphometric Analysis of Brain Structures
Source quote
L131: ChebyNet │ 0.870 │ 0.881 │ 0.850 │ 0.703 │ 0.790 │ 0.616 │ 0.735 │ 0.778 │ 0.667 │ 0.677 │ 0.563 │ 0.800
2026BrainNetCNN baselineaccuracy79.3%Classification · classes=NC vs. MCIArtemis: Anatomy-Resolved inTervention for Eliminating Multimodal NeuroImage confounderS
Source quote
L278: On ADNI, Artemis achieves 84.3% accuracy, a +5.0% absolute improvement over the best baseline BrainNetCNN (79.3%), and a macro-F1 of 73.5% compared with BrainNetCNN's 52.4%, a +21.1 percentage-point gain that reflects far more balanced recall across the NC and MCI classes.
2026Clinical-history-only configuration baselinebalanced accuracy0.595ClassificationAligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMs
Source quote
L873: history improves prognosis balanced accuracy from 0.595 to 0.652 (App. L). Removing PrimeKG leaves
2025ConnectomeDiffuser proposedACC71.25%ClassificationConnectomeDiffuser: Generative AI Enables Brain Network Construction From Diffusion Tensor Imaging
Source quote
L314: \multirow{6}{*}{ADNI} │ ConnectomeDiffuser │ 71.25 │ 71.84 │ 71.25 │ 71.09
2025IMMFM-forecast ventricular-area classifier proposedClassification accuracy80.8%Classification · split: test · input=IMMFM-forecast ventricular area · classification=AD-CN · forecast-horizon=36 monthsLongitudinal Flow Matching for Trajectory Modeling
Source quote
L351: Finally, we examine the specific progression of the disease. For the ADNI dataset, we focus on the ventricle region, as ventricular enlargement is a well-studied biomarker of AD progression and its underlying neurodegenerative process \citep{nestor2008ventricular}. IMMFM captures distinct ventricular growth trajectories for AD versus CN groups without explicit class conditioning (Fig.~\ref{fig:ad_dist}). Using only observed data at the second visit (\sim18 months), AD–CN classification reaches \bm{71.7%}. When using trajectories forecasted by our model to \sim36 months, AD-CN classification accuracy increases to \bm{80.8%}, a \bm{9.1%} gain. In practical terms, this corresponds to correctly classifying about nine additional subjects per 100, 18 months earlier than would be possible using only the observed data (see Appendix~\ref{app:classification_details} for additional details).
2025Heter-LBI (proposed method; table label “Ours”) proposedclassification accuracy88.96%Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=1.5TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L490: 88.96%
2025Heter-LBI (proposed method; table label “Ours”) proposedclassification accuracy91.48%Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=3.0TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L491: 91.48%
2025Heter-LBI (proposed method; table label “Ours”) proposedclassification accuracy74.00%Classification · split: val · comparison=MCI-vs-NC · validation=10-fold cross-validation · field-strength=1.5TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L492: 74.00% is enforced with spatial smoothness and non-negativity constraint to learn the lesion features and a dense parameter to additionally learn the procedural bias.
2025CoCoLIT proposedBA (balanced accuracy for Aβ-positivity classification)62.3%Classification · split: test · method-setting=LAS m=64 · classification-threshold=selected on internal validation setCoCoLIT: ControlNet-Conditioned Latent Image Translation for MRI to Amyloid PET Synthesis
Source quote
L163: m=64 │ 0.896 ± 0.050 │ 24.135 ± 2.820 │ 0.0050 ± 0.0047 │ 0.328~(p<0.001) │ 0.522~(p<0.001) │ 62.3%
2025MedOrch (o1-mini, best@5) proposedAccuracy93.26%ClassificationMedOrch: Medical Diagnosis with Tool-Augmented Reasoning Agents for Flexible Extensibility
Source quote
L262: Diagnostic Performance. On the three-class AD vs. MCI vs. NC classification task, \texttt{MedOrch}\xspace with o1-mini using the best@5 strategy achieves the highest accuracy of 93.26%, outperforming all baseline methods, including the previous state-of-the-art ConvNext+GPT approach (89.05%). This represents a 4.21% absolute improvement in accuracy. Similar patterns are observed in the four-class classification tasks (AD vs. EMCI vs. LMCI vs. NC), where \texttt{MedOrch}\xspace consistently outperforms baselines across all metrics. The significant improvement highlights the value of \texttt{MedOrch}\xspace' dynamic tool-calling approach, which can adapt its information-gathering strategy to each specific case.
2025MedOrch proposedAccuracy50.35%ClassificationMedOrch: Medical Diagnosis with Tool-Augmented Reasoning Agents for Flexible Extensibility
Source quote
L264: Prediction Performance. The disease progression prediction task proves more challenging for all. However, \texttt{MedOrch}\xspace shows a more pronounced advantage in this setting, achieving 50.35% accuracy with the best@5 and 38.61% with best@1. This significant lead over the baselines highlights \texttt{MedOrch}\xspace' superior ability to analyze temporal patterns in patient data and identify relevant progression indicators through its specialized tools and agents.
2025FLIQA-AD proposed non-standard sliceclassification accuracy (ACC)97%Classification · split: test · subset=300 samples per category · sampling=patient-levelFLIQA-AD: a Fusion Model with Large Language Model for Better Diagnose and MMSE Prediction of Alzheimer's Disease
Source quote
L202: 97% and 95%.
2025M3D + LGA proposedACC76.7%Classification · fine-tuned · runs=5 · backbone=M3D · component=LGA · training-samples=1,504Data-Efficient Fine-Tuning of Vision-Language Models for Diagnosis of Alzheimer's Disease
Source quote
L235: \quad + LGA~\cite{hu2024lga} │ 76.7 │ 80.0 │ + 85.2M │ 1,504
2025Proposed spatial-temporal transformer (Ours; temporal and spatial blocks) proposedACC89.1Classification · split: val · 5-fold-cv · evaluation=subject-levelClassification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal Transformer
Source quote
L148: 89.1
2025Proposed framework with contrastive learning proposedAccuracy improvement9.7%Classification · split: val · 5-fold-cv · component=contrastive-learning · comparison=without-contrastive-learning · evaluation=subject-levelClassification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal Transformer
Source quote
L114: To verify our proposed model, we compare it with other widely used methods in the literature listed in Table 1. Our results outperform most other studies. Furthermore, the proposed method incorporating contrastive learning strategy performs significantly better than the method without contrastive learning strategy on this data, showing an improvement of 9.7% in accuracy and 7.3% in F1 score when contrastive learning is applied.
2025SFC-GAN (translated FC) proposed non-standard sliceAccuracy16.67Classification · split: testSFC-GAN: A Generative Adversarial Network for Brain Functional and Structural Connectome Translation
Source quote
L161: Translated FC │ 16.67 │ 11.11 │ 16.67 │ 12.50 │ 52.18
2025SFC-GAN (translated SC) proposed non-standard sliceAccuracy41.67Classification · split: testSFC-GAN: A Generative Adversarial Network for Brain Functional and Structural Connectome Translation
Source quote
L162: Translated SC │ 41.67 │ 27.78 │ 41.67 │ 33.33 │ 57.78
2025Reinforced Domain Selection proposedAccuracy90.5ClassificationReinforced Domain Selection for Continuous Domain Adaptation
Source quote
L180: Ours │ 93.4 │ 90.5
2025S-only (spatial block only) ablationACC76.6Classification · split: val · 5-fold-cv · ablation=spatial-block-only · evaluation=subject-levelClassification of Mild Cognitive Impairment Based on Dynamic Functional Connectivity Using Spatio-Temporal Transformer
Source quote
L136: 76.6
2025LETetCNNACC (accuracy)0.794ClassificationEnhancing Alzheimer's Diagnosis: Leveraging Anatomical Landmarks in Graph Convolutional Neural Networks on Tetrahedral Meshes
Source quote
L159: LETetCNN │ 0.917 │ 0.915 │ 0.920 │ 0.755 │ 0.615 │ 0.835 │ 0.794 │ 0.778 │ 0.822
2025TetCNNACC (accuracy)0.730ClassificationEnhancing Alzheimer's Diagnosis: Leveraging Anatomical Landmarks in Graph Convolutional Neural Networks on Tetrahedral Meshes
Source quote
L157: TetCNN │ 0.876 │ 0.886 │ 0.859 │ 0.709 │ 0.660 │ 0.769 │ 0.730 │ 0.761 │ 0.700
2025KAN classifiertest accuracy81.85%Classification · split: testInterpreting Kolmogorov-Arnold Networks in Neuroimaging: A Path-Based Attribution Framework
Source quote
L181: We train a KAN on the datasets and achieve test accuracies of 93.24%, 81.85% and 91.25% respectively, on the OASIS-1, ADNI and Mendeley test sets. We also train the KAN on MNIST classification as a Proofof-Concept (PoC) and achieve a test accuracy of 99.4%. Using the proposed path-based attribution, we obtain an Insertion AUC of 0.865 ± 0.049, Deletion AUC of 0.282 ± 0.020, and Sufficiency of 0.068 ± 0.064 on the OASIS dataset as indicated in Table 1. On ADNI, the method achieves an Insertion AUC of 0.758
2025RCLAccuracy89.3ClassificationReinforced Domain Selection for Continuous Domain Adaptation
Source quote
L178: RCL \cite{xu2018reinforced} │ 91.5 │ 89.3
2025Observed-data ventricular-area classifier baselineClassification accuracy71.7%Classification · split: test · input=observed ventricular area · classification=AD-CNLongitudinal Flow Matching for Trajectory Modeling
Source quote
L351: Finally, we examine the specific progression of the disease. For the ADNI dataset, we focus on the ventricle region, as ventricular enlargement is a well-studied biomarker of AD progression and its underlying neurodegenerative process \citep{nestor2008ventricular}. IMMFM captures distinct ventricular growth trajectories for AD versus CN groups without explicit class conditioning (Fig.~\ref{fig:ad_dist}). Using only observed data at the second visit (\sim18 months), AD–CN classification reaches \bm{71.7%}. When using trajectories forecasted by our model to \sim36 months, AD-CN classification accuracy increases to \bm{80.8%}, a \bm{9.1%} gain. In practical terms, this corresponds to correctly classifying about nine additional subjects per 100, 18 months earlier than would be possible using only the observed data (see Appendix~\ref{app:classification_details} for additional details).
2025GSplit LBI baselineclassification accuracy88.31%Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=1.5TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L486: 88.31%
2025GSplit LBI baselineclassification accuracy88.64%Classification · split: val · comparison=AD-vs-NC · validation=10-fold cross-validation · field-strength=3.0TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L487: 88.64%
2025SVM baselineclassification accuracy73.50%Classification · split: val · comparison=MCI-vs-NC · validation=10-fold cross-validation · field-strength=1.5TA Differential Inclusion Approach for Learning Heterogeneous Sparsity in Neuroimaging Analysis
Source quote
L468: 73.50%
2025ConvNext+GPT baselineAccuracy89.05%ClassificationMedOrch: Medical Diagnosis with Tool-Augmented Reasoning Agents for Flexible Extensibility
Source quote
L262: Diagnostic Performance. On the three-class AD vs. MCI vs. NC classification task, \texttt{MedOrch}\xspace with o1-mini using the best@5 strategy achieves the highest accuracy of 93.26%, outperforming all baseline methods, including the previous state-of-the-art ConvNext+GPT approach (89.05%). This represents a 4.21% absolute improvement in accuracy. Similar patterns are observed in the four-class classification tasks (AD vs. EMCI vs. LMCI vs. NC), where \texttt{MedOrch}\xspace consistently outperforms baselines across all metrics. The significant improvement highlights the value of \texttt{MedOrch}\xspace' dynamic tool-calling approach, which can adapt its information-gathering strategy to each specific case.
2025Pretrained M3D (direct evaluation) baselineACC54.9%Classification · 0-shot · runs=5 · classes=3-wayData-Efficient Fine-Tuning of Vision-Language Models for Diagnosis of Alzheimer's Disease
Source quote
L233: \textbf{M3D~\cite{bai2024m3d}} │ 54.9 │ 52.6 │ 198M~(0) │ --
2025MedBLIP (original-paper baseline) baselineACC78.7%Classification · training-samples=10,387Data-Efficient Fine-Tuning of Vision-Language Models for Diagnosis of Alzheimer's Disease
Source quote
L241: MedBLIP~\cite{chen2024medblip}{}^\dagger │ 78.7 │ 85.3 │ 1.7B~(154M) │ 10,387
2024TabSeq proposedAccuracy64.44%Classification · partition=70:15:15 · feature-ordering=without · target-attribute=ABETA12TabSeq: A Framework for Deep Learning on Tabular Data via Sequential Ordering
Source quote
L254: TabSeq (ours) │ 64.44% │ 0.55 │ 75.13% │ 0.71
2024TabSeq proposedAccuracy75.13%Classification · partition=70:15:15 · feature-ordering=with; k-means, 5 clusters, ascending · target-attribute=ABETA12TabSeq: A Framework for Deep Learning on Tabular Data via Sequential Ordering
Source quote
L254: TabSeq (ours) │ 64.44% │ 0.55 │ 75.13% │ 0.71
2024PLM proposedACC0.8693Classification · split: testConnectional-style-guided contextual representation learning for brain disease diagnosis
Source quote
L328: 0.8693
2024MST-former (3 scales)ACC (Accuracy)90.3%Classification · resolution=256x256Multi-Scale Spatio-Temporal Transformer-Based Imbalanced Longitudinal Learning for Glaucoma Forecasting From Irregular Time Series Images
Source quote
L283: Ours │ 0.966 │ 90.3 │ 87.0 │ 94.2
2024GLIM-NetACC (Accuracy)77.9%Classification · resolution=256x256Multi-Scale Spatio-Temporal Transformer-Based Imbalanced Longitudinal Learning for Glaucoma Forecasting From Irregular Time Series Images
Source quote
L281: GLIM-Net~\cite{xiaoyan:23:glim} │ 0.866 │ 77.9 │ 61.4 │ 85.8
2024CDOT baselineAccuracy82.6Classification · intermediate-domains=2Enhancing Continuous Domain Adaptation with Multi-path Transfer Curriculum
Source quote
L217: CDOT \cite{ortiz2019cdot} │ 82.6 │ 0.0209 │ 75.6
2024DA-MIDL baselineACC0.9085Classification · split: testConnectional-style-guided contextual representation learning for brain disease diagnosis
Source quote
L333: 0.9085
2023WSEK (weighted subspace exponential kernel) proposedaverage classification accuracy79%Classification · split: val · modality=fMRI · classifier=KSTM · rank-selection=best average over Tucker ranks 1–10A weighted subspace exponential kernel for support tensor machines
Source quote
L381: (79% for ADNI and 64% for ADHD) compared to other state of the art tensor kernels. We note that the accuracy of the subspace kernel improves for higher ranks in the ADHD dataset and is then similar to that of WSEK but this choice of rank is very high for a low-rank truncation method. On the other hand, our proposed kernel gives good classification accuracy already at rank 2. The Gaussian kernel was computed for different Tucker approximations of the full tensor. Using the full tensor in the computation of the kernel did not improve the accuracy. As in~\cite{KourJMLR}, the DuSK kernel was computed using a CP approximation of the full tensor (CP-DuSK), because computing the Tucker decomposition and then converting to CP yielded high CP ranks and DuSK was too slow.
2023tLSSVM-MTL proposedACC98.17%Classification · split: test · tasks=4 × 4 × 3 · kernel=RBF · training-sample-ratio=0.3Low-Rank Multitask Learning based on Tensorized SVMs and LSSVMs
Source quote
L743: tLSSVM-MTL │ 98.17% │ 97.85% │ 98.48% │ 98.16%\% │ 5.31
2023MTL-LSSVM baselineACC95.42%Classification · split: test · tasks=4 × 4 × 3 · kernel=RBF · training-sample-ratio=0.3Low-Rank Multitask Learning based on Tensorized SVMs and LSSVMs
Source quote
L741: MTL-LSSVM │ 95.42% │ 94.61% │ 96.24% │ 95.42% \% │ 0.23
2022ETLN^E (ECN-only)ACC (prediction accuracy)73.47Classification · split: valA Structure-Guided Effective and Temporal-Lag Connectivity Network for Revealing Brain Disorder Mechanisms
Source quote
L175: ETLN (E) │ 74.31 │ 70.59 │ 77.59 │ 72.00 │ 78.02 │ 82.35 │ 72.50 │ 80.77 │ 73.47 │ 82.76 │ 60.00 │ 78.69
2022LRACC (prediction accuracy)67.35Classification · split: valA Structure-Guided Effective and Temporal-Lag Connectivity Network for Revealing Brain Disorder Mechanisms
Source quote
L169: LR │ 69.72 │ 66.67 │ 72.41 │ 67.33 │ 74.73 │ 80.39 │ 67.50 │ 78.10 │ 67.35 │ 75.86 │ 55.00 │ 73.33
2020TT-MMK proposedAverage classification accuracy73%Classification · split: val · 5-fold-cross-validation · data=resting-state fMRI · classes=AD+MCI vs normal controls · subjects=33 · repetitions=50Efficient Structure-preserving Support Tensor Train Machine
Source quote
L515: TT-MMK │ 73 │ 64 │ 99 │ 99
2020Improved MMK baselineAverage classification accuracy71%Classification · split: val · 5-fold-cross-validation · data=resting-state fMRI · classes=AD+MCI vs normal controls · subjects=33 · repetitions=50Efficient Structure-preserving Support Tensor Train Machine
Source quote
L514: Improved MMK │ 71 │ 61 │ 94 │ 98
2019Linear SVM using morphological age and disease score proposedMean classification accuracy0.59Classification · split: val · classes=MCI stable vs MCI converters · classifier=linear SVM · validation=10-fold cross-validationA model of brain morphological changes related to aging and Alzheimer's disease from cross-sectional assessments
Source quote
L291: We also perform a simple linear classification task between the MCIs and MCIc groups using this two cross-sectional markers. A SVM linear classifier is fitted to the full data-set to perform the binary classification\footnote{The classification task was performed using the SVC module of the scikit-learn python library~\citep{scikit-learn}}. The error penalty weights are adjusted between the two classes to balance the trade-off between false positive and false negative rate. The mean classification accuracy using a 10-folds cross-validation scheme is equal to 0.59. The linear decision function is equivalent to the projection on the SVF v_A - 0.003 v_D, so the differences between MCIs and MCIc subjects is, in our model, only associated with the aging trajectory while the disease specific changes do not seem to have an impact before the conversion. For comparison, for the same experiment between CN and AD, the linear classifier corresponds to the projection on v_A + 0.49 v_D so approximately (v-bn + v-ad) / 2, i.e. the mean evolution of the whole population. Of course, in both cases we do not reach the performance of state-of-the-art dedicated algorithm but it allows us to see how both markers are associated with the diagnosis. Moreover this discriminant approach could be extended by using information in a subset of targeted areas.
2018CNN (MRI-only) proposed non-standard sliceAccuracy92%Classification · split: test · subset=1,299 scans · modality=MRINeuroimaging modality fusion in Alzheimer’s classification using convolutional neural networks
Source quote
L80: MRI │ 92%
2018CNN (PET-only) proposed non-standard sliceAccuracy85%Classification · split: test · subset=585 scans · modality=amyloid PETNeuroimaging modality fusion in Alzheimer’s classification using convolutional neural networks
Source quote
L81: PET │ 85%
2018CNN (MRI+PET fusion) proposed non-standard sliceAccuracy94%Classification · split: test · subset=585 paired data points · modality=MRI+amyloid PET fusionNeuroimaging modality fusion in Alzheimer’s classification using convolutional neural networks
Source quote
L82: Fusion │ 94%
2014LR+GFL (logistic regression with generalized fused lasso) proposedaccuracy84.21%Classification · split: 10-fold-cv · cohort=AD vs healthy controls · modality=MRI · field-strength=1.5TEfficient Generalized Fused Lasso and its Application to the Diagnosis of Alzheimer's Disease
Source quote
L377: 84.21%
2014LR+GFL (logistic regression with generalized fused lasso) proposedaccuracy70.92%Classification · split: 10-fold-cv · cohort=MCI converters vs non-converters · modality=MRI · field-strength=1.5TEfficient Generalized Fused Lasso and its Application to the Diagnosis of Alzheimer's Disease
Source quote
L382: 70.92%
2014SVM baselineaccuracy82.71%Classification · split: 10-fold-cv · cohort=AD vs healthy controls · modality=MRI · field-strength=1.5TEfficient Generalized Fused Lasso and its Application to the Diagnosis of Alzheimer's Disease
Source quote
L375: 82.71%
2014LR+L1 (logistic regression with an L1 regularizer) baselineaccuracy68.79%Classification · split: 10-fold-cv · cohort=MCI converters vs non-converters · modality=MRI · field-strength=1.5TEfficient Generalized Fused Lasso and its Application to the Diagnosis of Alzheimer's Disease
Source quote
L381: 68.79%
2012QDA proposedAcc (%)66.14%Classification · features=shape, PET, APOE carrier status · weighting=η=0.8 · classifier=QDAGenetic, Structural and Functional Imaging Biomarkers for Early Detection of Conversion from MCI to AD
Source quote
L130: 66.14
2012QDA proposedaccuracy68%Classification · features=shape, PET, APOE carrier status, CSF Aβ-42 and ptau181 · weighting=η=0.8 · classifier=QDAGenetic, Structural and Functional Imaging Biomarkers for Early Detection of Conversion from MCI to AD
Source quote
L214: 29 NL, 36 AD and 59 MCI. With CSF-biomarkers, a slight increase in accuracy was observed for QDA: accuracy=68% and AUC= 0.72 (η = 0.8).