ACDC
242 papers · 564 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching regime=semi-supervised.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | TransMedSeg SOTA frontier | 89.96% | 2025-05-01 | labeled-data=10% · 7 labeled scans (10%) and 63 unlabeled scans (90%). | TransMedSeg: A Transferable Semantic Framework for Semi-Supervised Medical Image SegmentationSource quoteTransMedSeg │ 88.14 │ 79.48 │ 3.42 │ 0.97 │ 89.96 │ 82.31 │ 1.61 │ 0.64 |
| 2 | ACTION SOTA frontier (+2 variants) | 89.8% | 2022-06-01 | labeled-cases=7 · anatomical-category=RV · 7-labeled-case setting; RV category | Bootstrapping Semi-supervised Medical Image Segmentation with Anatomical-Aware Contrastive DistillationSource quoteTable \ref{table:acdc_main} shows the evaluation results on ACDC dataset under two unlabeled settings (3 or 7 labeled cases). ACTION can substantially improve results on two unlabeled settings, greatly outperforming the previous state-of-the-art SSL methods. Specifically, our ACTION, trained on 3 labeled cases, dramatically improves the previous best averaged Dice score from 73.6% to 87.5% by a large margin, and even matches previous SSL methods using 7 labeled cases. When using 7 labeled cases, ACTION further pushes the state-of-the-art results to 89.7% in Dice. We observe that the gains are more pronounced on the two categories(i.e., RV and Myo), and our ACTION achieves 89.8% and 86.7% in terms of Dice, performing competitive or even better than the supervised baseline (89.2% and 86.7%). As shown in Figure \ref{fig:vis_acdc}, we can see the clear advantage of ACTION, where the boundaries of different regions are clearly sharper and more accurate such as RV and Myo regions. Table \ref{table:lits_main} also shows the evaluation results on LiTS dataset under two unlabeled settings (5% or 10% labeled cases). On both two labeled settings, ACTION significantly outperforms all the state-of-the-art methods by a significant margin. As shown in Figure \ref{fig:vis_lits}, ACTION achieves consistently sharp and accurate object boundaries compared to other SSL methods. |
| 3 | MC-Net+ SOTA frontier (+1 variant) | 88.51% | 2022-01-01 | labeled-data=20% · unlabeled-data=80% · 20% labeled and 80% unlabeled scans; average over myocardium, left ventricle, and rig… | Mutual consistency learning for semi-supervised medical image segmentationSource quoteMC-Net+ (Ours) │ 88.51 │ 80.19 │ 5.35 │ 1.54 │ 1.81 │ 2.99 |
| 4 | DCPA | 85.86% | 2023-08-01 | labeled_scans=3 (5%) · dimensionality=2D · unlabeled_scans=67 (95%) · 2D segmentation; 3 labeled scans (5%) and 67 unlabeled scans (95%); Dice averaged acr… | Dual-Decoder Consistency via Pseudo-Labels Guided Data Augmentation for Semi-Supervised Medical Image SegmentationSource quoteOurs │ 85.86 │ 76.13 │ 5.83 │ 2.03 |
| 5 | AdvMIM | 85.4% | 2025-01-01 | labeled-data=3% · 3% labeled-data partition; semi-supervised medical image segmentation. | AdvMIM: Adversarial Masked Image Modeling for Semi-supervised Medical Image SegmentationSource quoteAdvMIM │ 85.4_{(10.1\textcolor{green}{\uparrow})} │ 2.0_{(8.7\textcolor{red}{\downarrow})} │ 89.0_{(0.6\textcolor{green}{\uparrow})} │ 1.3_{(3.1\textcolor{red}{\downarrow})} │ 66.3_{(1.0\textcolor{green}{\uparrow})} │ 22.7_{(9.9\textcolor{red}{\downarrow})} │ 74.8_{(3.4\textcolor{green}{\uparrow})} │ 15.5_{(15.7\textcolor{red}{\downarrow})} │ 79.8_{(1.9\textcolor{green}{\uparrow})} │ 22.2_{(9.9\textcolor{red}{\downarrow})} │ 81.8_{(0.7\textcolor{green}{\uparrow})} │ 19.5_{(4.9\textcolor{red}{\downarrow})} |
| 6 | Cross-ALD | 80.6% | 2023-10-01 | backbone=U-Net · labeled-data=5% · Semi-supervised segmentation with 5% labeled data (3 labeled scans and 67 unlabeled s… | Cross-adversarial local distribution regularization for semi-supervised medical image segmentationSource quoteCross-ALD (Ours) │ 80.6 │ 69.08 │ 5.96 │ 1.9 │ 1.83 │ 2.99 |
| 7 | AugPaint (+1 variant) | 77.73% | 2025-06-01 | labeled-cases=5 · AugPaint-only row; 5 labeled cases. | Inpainting is All You Need: A Diffusion-based Augmentation Method for Semi-supervised Medical Image SegmentationSource quote\multirow{4}{*}{ACDC} │ AugPaint │ 42.42 │ 44.15 │ 77.73 |
Regimesemi-supervised (65)fine-tuned (21)weakly-supervised (11)domain-generalization (11)test-time-adaptation (10)scribble-supervised (8)
Showing 150 of 151 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | SDT-Net proposed | Average Dice score | 90.8% | split: test | Scribble-Supervised Medical Image Segmentation With Dynamic Teacher Switching and Hierarchical ConsistencySource quoteL143: Ours │ 93.5 │ 89.3 │ 89.6 │ 90.8 |
| 2026 | EvoML proposed | Dice | 0.919 | split: test · supervised | Validation-Gated ML Pipeline Synthesis with Expert-Grounded Self-Evolving SkillsSource quoteL1410: 0.919 |
| 2026 | ProGeo-RC proposed | 95HD | 1.54 | split: test | ProGeo-RC: Prototype-guided Semantic Reliability and Geometric Error Calibration for Semi-supervised Cardiac Image SegmentationSource quoteL959: 1.54 |
| 2026 | ProGeo-RC proposed | ASD | 0.57 | split: test | ProGeo-RC: Prototype-guided Semantic Reliability and Geometric Error Calibration for Semi-supervised Cardiac Image SegmentationSource quoteL960: 0.57 |
| 2026 | AutoMedImg-Claude-4.5-Opus proposed | Dice | 0.9041 | split: test · supervised · trials=Pass@3 · modality=MRI · dimension=3D | Towards Fully Automated Medical Imaging Code Generation via Validation-based Context EngineeringSource quoteL376: \texttt{AutoMedImg-Claude-4.5-Opus} │ 0 │ 0.8185 │ 0 │ 0.9041 │ 0 │ 0.7696 │ 0 │ 0.8789 │ 0 │ 0.9517 │ 0 │ 0.9938 |
| 2026 | HeuSCM (HRDA backbone) proposed | mIoU | 72.9% | split: test · domain-adaptation · backbone=HRDA · domain-transfer=Cityscapes→ACDC | Heuristic Self-Paced Learning for Domain Adaptive Semantic Segmentation under Adverse ConditionsSource quoteL306: The quantitative results of mIoU performances on the ACDC test set and the ACDC val set are reported in Table~\ref{t:acdctest} and Table~\ref{t:acdctval}, respectively. We observe that our method consistently outperforms existing approaches across different backbones on both the ACDC test and validation sets. Notably, when built upon the HRDA backbone, our method achieves mIoU scores of 72.9 and 72.7 mIoU [%] on the ACDC test and val sets, respectively, establishing state-of-the-art performance for Cityscapes \rightarrow ACDC domain adaptation. |
| 2025 | SSS proposed | Dice coefficient | 89.34% | split: test | SSS: Semi-Supervised SAM-2 with efficient prompting for medical imaging segmentationSource quoteL239: \subsubsection{Automated Cardiac Diagnosis Challeng (ACDC).} Table~\ref{tab2} reports the quantitative evaluation results of the proposed SSS on the ACDC dataset and systematically compares it with current state-of-the-art semi-supervised segmentation methods. The evaluation is performed under two different supervision settings, using 3% and 10% labeled data, simulating real clinical scenarios with extremely scarce annotated data. The results demonstrate that the SSS method excels across all evaluation metrics, significantly outperforming existing comparison methods. Under the 3% labeled data setting, SSS achieves a Dice score of 89.34, a Jaccard index of 82.20, a 95% Hausdorff Distance (95HD) of 1.42, and an Average Surface Distance (ASD) of 0.43. When using 10% labeled data, all metrics improve further to 91.21, 82.97, 1.30, and 0.31, respectively. These results fully validate the robustness and superior segmentation performance of the proposed method under low-supervision conditions. As a multi-class segmentation model, it achieved a Dice score of 44.50 ± 0.17 under the same settings. This further highlights the adaptability and superiority of our method across different tasks. |
| 2025 | CLFSeg (17 filters) proposed | DSC | 0.9522 | split: test | CLFSeg: A Fuzzy-Logic based Solution for Boundary Clarity and Uncertainty Reduction in Medical Image SegmentationSource quoteL368: In the cardiac segmentation task on the ACDC dataset, CLFSeg match the performance with baseline \cite{dumitru2023using} for 17 and 34 filters. But exceeded the performance of recent models such as Duck-Net and Adaptive t-vMF for 17 filters, reaching a DSC of 0.9522 and IoU of 0.9087 while reducing computational complexity by up to 30% as shown in Table \ref{table:CLFSeg_ACDC_Results}. |
| 2025 | Self-Prompt-SAM proposed | Average DSC | 93.26% | split: test · backbone=SAM | Self-Prompt SAM: Medical Image Segmentation via Automatic Prompt SAM AdaptationSource quoteL157: Self-Prompt-SAM (Ours) │ 93.26 │ 92.20 │ 91.22 │ 96.36 |
| 2025 | SURGEON proposed | Mean online error | 42.2% | split: test · test-time-adaptation · backbone=SegFormer-B5 · conditions=Fog, Night, Rain, Snow · timestamps=1, 4, 7, 10 | SURGEON: Memory-Adaptive Fully Test-Time Adaptation via Dynamic Activation SparsitySource quoteL299: \multicolumn{1}{l|}{} │ Surgeon │ 30.9 │ 59.7 │ 40.0 │ 42.2 │ 30.4 │ 59.1 │ 39.1 │ 41.7 │ 30.0 │ 58.7 │ 38.3 │ 41.3 │ 29.7 │ 58.3 │ 37.9 │ 41.0 │ 42.2 │ 380 |
| 2025 | SURGEON proposed | Cache size | 380 MB | split: test · test-time-adaptation · backbone=SegFormer-B5 · conditions=Fog, Night, Rain, Snow · timestamps=1, 4, 7, 10 | SURGEON: Memory-Adaptive Fully Test-Time Adaptation via Dynamic Activation SparsitySource quoteL299: \multicolumn{1}{l|}{} │ Surgeon │ 30.9 │ 59.7 │ 40.0 │ 42.2 │ 30.4 │ 59.1 │ 39.1 │ 41.7 │ 30.0 │ 58.7 │ 38.3 │ 41.3 │ 29.7 │ 58.3 │ 37.9 │ 41.0 │ 42.2 │ 380 |
| 2025 | IntelliCardiac (Ours w/ ROI; final classification after expert refinement) proposed | overall accuracy | 98% | split: test · method=ROI with expert SVM refinement for ambiguous cases · subset=50 evaluation patients | IntelliCardiac: An Intelligent Platform for Cardiac Image Segmentation and ClassificationSource quoteL205: Ours (w/ ROI) │ 92.56 │ 92.27 │ 90.33 │ 95.09 │ 92% / 98% |
| 2025 | MedSegFactory proposed | FID | 158.11 | split: test · generated-set-size=matched to test set | MedSegFactory: Text-Guided Generation of Medical Image-Mask PairsSource quoteL223: MedSegFactory │ 158.11 │ 3.51 │ 156.97 │ 2.44 │ 227.88 │ 2.43 |
| 2025 | MedSegFactory proposed | DSC | 88.02% | split: test · trained-on-generated-data · segmentation-model=nnUNet | MedSegFactory: Text-Guided Generation of Medical Image-Mask PairsSource quoteL261: MedSegFactory │ 88.02 │ 81.50 │ 83.38 │ 78.75 │ 90.85 │ 86.61 |
| 2025 | SparseMamba-PCL proposed | Dice | 89.15% | split: test · scribble-supervised · cross-validation=5-fold | SparseMamba-PCL: Scribble-Supervised Medical Image Segmentation via SAM-Guided Progressive Collaborative LearningSource quoteL162: SparseMamba-PCL │ 89.15 │ 5.49 │ 73.84 │ 16.77 │ 82.13 │ 41.79 |
| 2025 | CENet proposed | aDSC | 92.18% | split: test · epochs=100 | CENet: Context Enhancement Network for Medical Image SegmentationSource quoteL146: CENet │ \textcolor{blue}{92.18} │ \textcolor{blue}{90.90} │ \textcolor{blue}{89.63} │ \textcolor{blue}{95.99} |
| 2025 | AstMatch proposed | DSC (%) | 90.47% | split: test · backbone=2D U-Net · labeled-fraction=10% | AstMatch: Adversarial self-training consistency framework for semi-supervised medical image segmentationSource quoteL1306: 90.47 |
| 2025 | WMREN proposed | Avg. DSC | 92.12% | split: test · resolution=224×224 | Wavelet Multi-scale Region-Enhanced Network for Medical Image SegmentationSource quoteL404: Tables 2 and 3 show the results on ACDC and ISIC17 datasets, respectively. WMREN also performs the best on these datasets. Our method achieves a leading average DSC of 92.12% on ACDC dataset and 87.67% on ISIC17 dataset, demonstrating the superiority of the proposed method. |
| 2025 | Sim-MPNet proposed | DSC | 92.18% | split: test | Similarity Memory Prior is All You Need for Medical Image SegmentationSource quoteL169: ACDC. ACDC datasets test the model's ability to explore local details, and ViT-based methods are often difficult to achieve better segmentation results. \Cref{table1} shows that the DSC of SwinUNet, TransDeepLab and DAE-Former does not exceed 90%. Although the hybrid CNN-ViT methods partially compensate for the shortcomings of ViT, its highest DSC is only 91.48%. In contrast, Sim-MPNet can directly capture the category features of organs in ACDC by dynamic memory prior mechanism, thus achieving 92.18% DSC and acquiring better segmentation results. |
| 2025 | EW-ViT | Avg DICE | 90.29% | split: test | Frequency-Domain Refinement of Vision Transformers for Robust Medical Image Segmentation Under DegradationSource quoteL560: 90.29%, surpassing TransUNet and SwinUNet by 0.58% and 0.29% respectively, showcasing superior accuracy in cardiac structure delineation. Specifically, our method excels in Myo segmentation with a DICE score of 87.56%, outperforming Swin-UNet and TransUNet by 1.94% and |
| 2025 | Mamba-UNet baseline | DSC | 91.08% | split: test · resolution=256×256 · split-ratio=70% train, 10% validation, 20% test | UD-Mamba: A pixel-level uncertainty-driven Mamba model for medical image segmentationSource quoteL209: Mamba-UNet~\cite{wang2024mamba_unet} │ 91.08 │ 90.80 │ 88.09 │ 94.35 │ 84.03 │ 1.40 |
| 2025 | Mamba-UNet baseline | mIoU | 84.03% | split: test · resolution=256×256 · split-ratio=70% train, 10% validation, 20% test | UD-Mamba: A pixel-level uncertainty-driven Mamba model for medical image segmentationSource quoteL209: Mamba-UNet~\cite{wang2024mamba_unet} │ 91.08 │ 90.80 │ 88.09 │ 94.35 │ 84.03 │ 1.40 |
| 2025 | SDM baseline | FID | 160.98 | split: test · generated-set-size=matched to test set | MedSegFactory: Text-Guided Generation of Medical Image-Mask PairsSource quoteL219: SDM~\cite{rombach2022high} │ 160.98 │ 3.47 │ 168.71 │ 2.08 │ 235.19 │ 2.24 |
| 2025 | DiffBoost baseline | DSC | 87.29% | split: test · trained-on-generated-data · segmentation-model=nnUNet | MedSegFactory: Text-Guided Generation of Medical Image-Mask PairsSource quoteL260: DiffBoost~\cite{zhang2024diffboost} │ 87.29 │ 80.66 │ 78.11 │ 72.46 │ 89.33 │ 84.63 |
| 2025 | SparseMamba (Baseline) baseline | Dice | 81.47% | split: test · scribble-supervised · cross-validation=5-fold | SparseMamba-PCL: Scribble-Supervised Medical Image Segmentation via SAM-Guided Progressive Collaborative LearningSource quoteL159: Scribbleformer \cite{li2024scribformer} │ TMI24 │ 88.63 │ 5.85 │ 72.27 │ 19.04 │ 81.47 │ 46.02\\Baseline │ \multirow{4}{*}{Proposed} │ 81.47 │ 39.95 │ 68.01 │ 42.63 │ 73.25 │ 69.77 |
| 2025 | BCP [6] baseline | DSC (%) | 88.84% | split: test · backbone=2D U-Net · labeled-fraction=10% | AstMatch: Adversarial self-training consistency framework for semi-supervised medical image segmentationSource quoteL1301: 88.84 |
| 2024 | HResFormer (table label: Ours) proposed | DSC | 91.88 | split: test | HResFormer: Hybrid Residual Transformer for Volumetric Medical Image SegmentationSource quoteL361: Ours │ 91.88 │ 90.44 │ 89.50 │ 95.79 |
| 2024 | MemWarp proposed | Average Dice | 89.61% | split: test · semi-supervised · inference-masks=not-required | MemWarp: Discontinuity-Preserving Cardiac Registration with Memorized Anatomical FiltersSource quoteL185: MemWarp (ours) │ 89.61 │ 89.30 │ 86.49 │ 93.04 │ 3.93 │ 0.149 |
| 2024 | MemWarp proposed | HD95 | 3.93 mm | split: test · semi-supervised · inference-masks=not-required | MemWarp: Discontinuity-Preserving Cardiac Registration with Memorized Anatomical FiltersSource quoteL185: MemWarp (ours) │ 89.61 │ 89.30 │ 86.49 │ 93.04 │ 3.93 │ 0.149 |
| 2024 | CorrMLP proposed | DSC | 0.810 | split: test | Correlation-aware Coarse-to-fine MLPs for Deformable Medical Image RegistrationSource quoteL431: 0.810 |
| 2024 | SNet proposed | Average Dice | 91.55% | split: test · aggregation=average across RV, Myo, and LV | Rethinking Information Loss in Medical Image Segmentation with Various-sized TargetsSource quoteL345: SNet (ours) │ 90.56 │ 89.61 │ 94.47 │ 91.55 |
| 2024 | LoG-VMamba (3D U-Mamba-Enc-based model) proposed | Dice | 92.18% | split: test · backbone=3D U-Mamba-Enc | LoG-VMamba: Local-Global Vision Mamba for Medical Image SegmentationSource quoteL259: Ours │ 59.7M │ 467.9G │ \subbest{92.18-±0.13} │ \subbest{1.10-±0.00} |
| 2024 | LoG-VMamba (3D U-Mamba-Enc-based model) proposed | HD95 | 1.10 mm | split: test · backbone=3D U-Mamba-Enc | LoG-VMamba: Local-Global Vision Mamba for Medical Image SegmentationSource quoteL259: Ours │ 59.7M │ 467.9G │ \subbest{92.18-±0.13} │ \subbest{1.10-±0.00} |
| 2024 | ControlUDA proposed | mIoU | 71.6 | split: test · adaptation=Cityscapes-to-ACDC · weak-supervision=no extra clear reference images | ControlUDA: Controllable Diffusion-assisted Unsupervised Domain Adaptation for Cross-Weather Semantic SegmentationSource quoteL175: {\bf Benchmark Evaluation} We evaluate ControlUDA and compare it with SOTA methods for domain adaptive semantic segmentation in adverse conditions. As shown in Table~\ref{tab:citytoacdc}, ControlUDA shows superior performance to the SOTA methods on test set of Cityscapes-to-ACDC adaptation, pushing the upper bound of this unsupervised task further and obtaining 71.6 mIoU even without any weak supervision from reference data. An visual impression is given in Fig.\ref{fig:seg_output}. The superiority of ControlUDA is also verified on the val sets of the benchmarks (shown in Table~\ref{tab:val_city2acdcdz}), and it achieves 71.8 and 47.6 mIoU respectively, outperforming SOTA methods by considerable margins. |
| 2024 | DRDM augmentation + vanilla U-Net proposed | Average DSC | 68.2% | split: test · 5-shot · backbone=vanilla U-Net · augmentation=DRDM · labeled-subjects=5 (5%) | Deformation-Recovery diffusion model (DRDM): Instance deformation for image manipulation and synthesisSource quoteL556: DRDM │ 77.0 │ {73.7} │ 84.1 │ 59.6 │ 55.8 │ 77.3 │ 67.9 │ 68.5 │ 73.4 │ 68.2 │ 66.0 │ 78.3 |
| 2024 | SemSim proposed | DSC | 0.872 | split: test · semi-supervised · labeled-data=1% (1 case) | SemSim: Revisiting Weak-to-Strong Consistency from a Semantic Similarity Perspective for Semi-supervised Medical Image SegmentationSource quoteL361: SemSim │ {\color[HTML]{FF0000}0.872} │ {\color[HTML]{FF0000}1.8} │ {\color[HTML]{FF0000}0.888} │ {\color[HTML]{FF0000}1.9} │ {\color[HTML]{FF0000}0.896} │ {\color[HTML]{FF0000}2.3} │ 2.60 |
| 2024 | SemSim proposed | 95HD | 1.8 mm | split: test · semi-supervised · labeled-data=1% (1 case) | SemSim: Revisiting Weak-to-Strong Consistency from a Semantic Similarity Perspective for Semi-supervised Medical Image SegmentationSource quoteL361: SemSim │ {\color[HTML]{FF0000}0.872} │ {\color[HTML]{FF0000}1.8} │ {\color[HTML]{FF0000}0.888} │ {\color[HTML]{FF0000}1.9} │ {\color[HTML]{FF0000}0.896} │ {\color[HTML]{FF0000}2.3} │ 2.60 |
| 2024 | 2D AgileFormer proposed | average DSC | 92.55% | split: test · dimension=2D · resolution=224×224 | AgileFormer: Spatially Agile Transformer UNet for Medical Image SegmentationSource quoteL252: One the ACDC dataset, AgileFormer achieved an average DSC (%) of 92.55, surpassing all the baseline methods in segmenting RV, Myo, and LV (see~\Cref{tab:ACDC}; 2D Models). |
| 2024 | CCT-R (mean, Affine) proposed | DSC | 80.4% | split: test · fusion=mean logits · registration=affine · labeled_cases=1 · labeled_fraction=1.4% | Learning Semi-Supervised Medical Image Segmentation from Spatial RegistrationSource quoteL592: Ours (mean, Affine) │ \bf{80.4} │ \bf{3.5} │ \bf{78.3} │ \bf{3.2} │ \bf{83.6} │ 4.3 │ 79.3 │ \bf{2.9} |
| 2024 | CCT-R (mean, Affine) proposed | HD | 3.5 mm | split: test · fusion=mean logits · registration=affine · labeled_cases=1 · labeled_fraction=1.4% | Learning Semi-Supervised Medical Image Segmentation from Spatial RegistrationSource quoteL592: Ours (mean, Affine) │ \bf{80.4} │ \bf{3.5} │ \bf{78.3} │ \bf{3.2} │ \bf{83.6} │ 4.3 │ 79.3 │ \bf{2.9} |
| 2024 | Hybrid-TTA proposed | Average frame rate | 1.16 fps | split: test · continual-test-time-adaptation · rounds=3 · source-domain=Cityscapes | Hybrid-TTA: Continual Test-time Adaptation via Dynamic Domain Shift DetectionSource quoteL271: Frame rate (fps \uparrow ) │ 0.058 │ 0.043 │ 1.16 |
| 2024 | Proposed multitask learning (MTL; relative orientation and relative location regression) proposed non-standard slice | AUC | 0.839 | split: test · fine-tuned · subset=1 subject · classifier=100-tree random forest | Self-supervised learning for medical image data with anatomy-oriented imaging planesSource quoteL495: MTL │ 0.839 │ 0.903 │ 0.959 │ 0.959 │ 0.972 |
| 2024 | CPA-Enhancer + SegFormer (Ours(S)) proposed | mIoU | 72.2% | split: test · backbone=SegFormer | CPA-Enhancer: Chain-of-Thought Prompted Adaptive Enhancer for Object Detection under Unknown DegradationsSource quoteL520: We present quantitative comparisons on the ACDC test set, and corresponding results are provided in \cref{tab:seg}. As expected, our model continues to achieve the best result with a mIoU of 72.2%, substantially outperforming the previous best result (Refign\cite{refign}) by 6.7 points. For convincing evidence, we further show the visual quality comparisons in \cref{fig:app_seg}. Our CPA-Enhancer consistently outperforms Refine in terms of generating more precise segmentation maps under different degradation types, indicating the versatility and robustness of our approach in handling visual tasks under multiple unknown degradations. |
| 2024 | ScribbleVS proposed | average Dice | 90.6% | split: test · scribble-supervised · supervision=scribble | ScribbleVS: Scribble-Supervised Medical Image Segmentation via Dynamic Competitive Pseudo Label SelectionSource quoteL181: Specifically, our method outperforms DMSPS-stage2. On the ACDC dataset, it achieves a 0.8% improvement over DMSPS-stage2 (90.6% vs 89.8%), while on the MSCMRseg dataset, it achieves a 1.0% improvement compared to DMSPS-stage1 (88.7% vs 87.7%). |
| 2024 | Ours (ResNet) proposed | mIoU | 55.95% | split: test · backbone=ResNet · aggregation=mean across Fog, Night, Rain, and Snow · training-data=Cityscapes | Generalize or Detect? Towards Robust Semantic Segmentation Under Multiple Distribution ShiftsSource quoteL433: Ours │ 74.84 │ 30.33 │ 61.15 │ 57.80 │ 55.95 ISSA\cite{ISSA} │ \multirow{3}{*}{Mask2Former} │ 67.5 │ 33.2 │ 55.9 │ 53.2 │ 52.5 |
| 2024 | Ours-ABD (BCP) proposed | DSC↑ | 89.81 | split: test · semi-supervised | Adaptive Bidirectional Displacement for Semi-Supervised Medical Image SegmentationSource quoteL505: 89.81 |
| 2024 | Ours-ABD (BCP) proposed | 95HD↓ | 1.46 | split: test · semi-supervised | Adaptive Bidirectional Displacement for Semi-Supervised Medical Image SegmentationSource quoteL507: 1.46 |
| 2024 | Ours-ABD (BCP) proposed | ASD↓ | 0.49 | split: test · semi-supervised | Adaptive Bidirectional Displacement for Semi-Supervised Medical Image SegmentationSource quoteL508: 0.49 |
| 2024 | DeNAS-ViT proposed | DSC | 0.915 | split: test · semi-supervised-15-labeled · resolution=224×224 · labeled-data=15% | DeNAS-ViT: Data Efficient NAS-Optimized Vision Transformer for Ultrasound Image SegmentationSource quoteL380: DeNAS-ViT │ \boldsymbol{0.890} ({\textbf{\textcolor{iccvblue}{+0.059}}}) │ \boldsymbol{3.356} (\textbf{\textcolor{iccvblue}{-7.265}}) │ \boldsymbol{0.915} (\textbf{\textcolor{iccvblue}{+0.064}}) │ \boldsymbol{1.677} (\textbf{\textcolor{iccvblue}{-5.627}}) |
| 2024 | UniA proposed | Confusion ratio (CR; FP/TP) | 0.21 | split: test · subset=25 cases | Tackling Ambiguity from Perspective of Uncertainty Inference and Affinity Diversification for Weakly Supervised Semantic SegmentationSource quoteL417: We also implement it on medical datastet ACDC, which features ambiguity (low contrast and similar textures). Confusion ratio (CR) and DSC are selected as the metrics to evaluate. As reported in Table~\ref{table.6}, incapable of inferring the ambiguous region, ToCo~\cite{24} achieves 80.36% DSC and 0.49 confusion ratio. Compared to it, UniA is more competent at tackling ambiguous images. Our method achieves better DSC of 83.75% and CR of 0.21, which significantly outperforms ToCo by 28% in CR and even surpasses counterparts specially designed for medical images~\cite{46}. |
| 2024 | M-CnT proposed | DSC | 0.753 | split: test · semi-supervised · labeled-data=3% | Combinatorial CNN-Transformer Learning with Manifold Constraints for Semi-supervised Medical Image SegmentationSource quoteL318: 0.753 |
| 2024 | SND proposed | IoU | 48.1% | split: test · backbone=DeepLab-v2 with ResNet-101 · adaptation=source-free domain adaptation · domain-shift=Cityscapes to ACDC; clean to adverse weather | Stable Neighbor Denoising for Source-free Domain Adaptive SegmentationSource quoteL254: SND (Ours) │ 74.8 │ 27.6 │ 69.3 │ 23.6 │ 26.3 │ 36.5 │ 52.8 │ 54.6 │ 75.5 │ 35.0 │ 84.8 │ 52.5 │ 25.5 │ 78.8 │ 44.9 │ 48.1 │ 37.6 │ 31.1 │ 34.9 │ 48.1 |
| 2024 | FATNet + DTMFormer proposed | Average Dice | 92.53 | split: test | DTMFormer: Dynamic Token Merging for Boosting Transformer-Based Medical Image SegmentationSource quoteL295: 92.53 |
| 2024 | nnU-Net | DSC | 91.36 | split: test | HResFormer: Hybrid Residual Transformer for Volumetric Medical Image SegmentationSource quoteL359: nnU-Net~\citep{nnunet} │ 91.36 │ 90.11 │ 88.75 │ 95.23 |
| 2024 | Slicer Network baseline | Average Dice | 83.68% | split: test · semi-supervised | MemWarp: Discontinuity-Preserving Cardiac Registration with Memorized Anatomical FiltersSource quoteL184: Slicer Network \cite{zhang2024slicer} │ 83.68 │ 84.94 │ 77.97 │ 88.12 │ 6.10 │ 0.099 |
| 2024 | DDIR baseline | HD95 | 9.91 mm | split: test · weakly-supervised · inference-masks=required | MemWarp: Discontinuity-Preserving Cardiac Registration with Memorized Anatomical FiltersSource quoteL187: DDIR \cite{chen2021deep} │ \multirow{1}{*}{\shortstack[l]{~Weakly-supervised}} │ 88.03 │ 90.02 │ 85.47 │ 87.61 │ 9.91 │ 0.121 |
| 2024 | nnFormer baseline | Segmentation Dice | 90.15% | split: test · use=DDIR-mask-generation | MemWarp: Discontinuity-Preserving Cardiac Registration with Memorized Anatomical FiltersSource quoteL150: For DDIR, we employ the leading model nnFormer \cite{zhou2023nnformer} for segmentation, achieving a Dice score of 90.15% on the test set. |
| 2024 | HRDA, MiT-B5 encoder baseline | mIoU | 46.3% | split: test · domain-generalization · backbone=MiT-B5 | WeatherDG: LLM-assisted Diffusion Model for Procedural Weather Generation in Domain-Generalized Semantic SegmentationSource quoteL133: HRDA\cite{hoyer2022hrda} │ 46.3 │ 49.8 │ 25.8 │ 40.6 |
| 2024 | SegFormer-B4 (baseline) baseline | mIoU | 67.1 | split: test · test-scale=single-scale | Optimizing against Infeasible Inclusions from Data for Semantic Segmentation through MorphologySource quoteL169: SegFormer-B4 (baseline)\cite{17} │ 49.7 │ 82.2 │ 67.1 |
| 2024 | BigAug augmentation + vanilla U-Net baseline | Average DSC | 57.7% | split: test · 5-shot · backbone=vanilla U-Net · augmentation=BigAug · labeled-subjects=5 (5%) | Deformation-Recovery diffusion model (DRDM): Instance deformation for image manipulation and synthesisSource quoteL553: BigAug │ 75.8 │ 73.6 │ {83.2} │ 37.6 │ 29.6 │ 65.2 │ 65.6 │ 66.0 │ 69.1 │ 59.7 │ 57.7 │ 72.5 |
| 2024 | Training from scratch (None) baseline non-standard slice | AUC | 0.608 | split: test · fine-tuned · subset=1 subject · classifier=100-tree random forest | Self-supervised learning for medical image data with anatomy-oriented imaging planesSource quoteL485: None │ 0.608 │ 0.825 │ 0.861 │ 0.909 │ 0.920 |
| 2024 | ISW (ResNet) baseline | mIoU | 52.5% | split: test · backbone=ResNet · aggregation=mean across Fog, Night, Rain, and Snow · training-data=Cityscapes | Generalize or Detect? Towards Robust Semantic Segmentation Under Multiple Distribution ShiftsSource quoteL432: ISW\cite{ISW} │ 67.5 │ 33.2 │ 55.9 │ 53.2 │ 52.5 |
| 2024 | BCP (CVPR’2023) baseline | DSC↑ | 88.84 | split: test · semi-supervised | Adaptive Bidirectional Displacement for Semi-Supervised Medical Image SegmentationSource quoteL495: 88.84 |
| 2024 | BCP (CVPR’2023) baseline | 95HD↓ | 3.98 | split: test · semi-supervised | Adaptive Bidirectional Displacement for Semi-Supervised Medical Image SegmentationSource quoteL497: 3.98 |
| 2024 | BCP (CVPR’2023) baseline | ASD↓ | 1.17 | split: test · semi-supervised | Adaptive Bidirectional Displacement for Semi-Supervised Medical Image SegmentationSource quoteL498: 1.17 |
| 2024 | CnT-B baseline | DSC | 0.876 | split: test · semi-supervised-10-labeled · resolution=224×224 · labeled-data=10% | DeNAS-ViT: Data Efficient NAS-Optimized Vision Transformer for Ultrasound Image SegmentationSource quoteL376: CnT-B │ 0.876 ({\textcolor{iccvblue}{+0.045}}) │ 5.120 ({\textcolor{iccvblue}{-5.501}}) │ {0.894} ({\textcolor{iccvblue}{+0.043}}) │ {2.853} ({\textcolor{iccvblue}{-4.451}}) |
| 2024 | ToCo baseline | Confusion ratio (CR; FP/TP) | 0.49 | split: test · subset=25 cases | Tackling Ambiguity from Perspective of Uncertainty Inference and Affinity Diversification for Weakly Supervised Semantic SegmentationSource quoteL417: We also implement it on medical datastet ACDC, which features ambiguity (low contrast and similar textures). Confusion ratio (CR) and DSC are selected as the metrics to evaluate. As reported in Table~\ref{table.6}, incapable of inferring the ambiguous region, ToCo~\cite{24} achieves 80.36% DSC and 0.49 confusion ratio. Compared to it, UniA is more competent at tackling ambiguous images. Our method achieves better DSC of 83.75% and CR of 0.21, which significantly outperforms ToCo by 28% in CR and even surpasses counterparts specially designed for medical images~\cite{46}. |
| 2024 | SFDASEG (ICCV21)† baseline | IoU | 46.4% | split: test · backbone=DeepLab-v2 with ResNet-101 · adaptation=source-free domain adaptation · domain-shift=Cityscapes to ACDC; clean to adverse weather · method-variant=multiple heads; specific source-side network | Stable Neighbor Denoising for Source-free Domain Adaptive SegmentationSource quoteL252: SFDASEG (ICCV21) (\dag) \cite{Kundu_2021_ICCV} │ 73.5 │ 29.0 │ 70.7 │ 19.7 │ 21.9 │ 36.1 │ 53.2 │ 51.4 │ 72.0 │ 31.1 │ 85.3 │ 41.5 │ 26.2 │ 76.4 │ 41.9 │ 46.1 │ 39.8 │ 33.3 │ 32.0 │ 46.4 |
| 2024 | FATNet baseline | Average Dice | 91.94 | split: test | DTMFormer: Dynamic Token Merging for Boosting Transformer-Based Medical Image SegmentationSource quoteL290: 91.94 |
| 2023 | CMA (SegFormer) proposed | mean IoU | 61.3 | split: test · backbone=SegFormer · condition=night · source-dataset=Cityscapes · target-training-data=full ACDC | Contrastive Model Adaptation for Cross-Condition Robustness in Semantic SegmentationSource quoteL600: CMA │ 95.2 │ 77.5 │ 84.3 │ 43.9 │ 30.9 │ 49.4 │ 52.0 │ 49.6 │ 74.2 │ 51.2 │ 78.4 │ 61.4 │ 41.2 │ 79.2 │ 63.6 │ 75.1 │ 75.8 │ 34.6 │ 47.3 │ 61.3 |
| 2023 | CMA (SegFormer) proposed | mean IoU | 72.5 | split: test · backbone=SegFormer · condition=rain · source-dataset=Cityscapes · target-training-data=full ACDC | Contrastive Model Adaptation for Cross-Condition Robustness in Semantic SegmentationSource quoteL616: CMA │ 93.3 │ 76.3 │ 92.8 │ 58.1 │ 58.2 │ 61.2 │ 70.4 │ 71.8 │ 93.8 │ 45.0 │ 97.9 │ 67.4 │ 36.8 │ 89.7 │ 72.2 │ 88.5 │ 86.4 │ 50.5 │ 66.7 │ 72.5 |
| 2023 | CMA (SegFormer) proposed | mean IoU | 71.5 | split: test · backbone=SegFormer · condition=snow · source-dataset=Cityscapes · target-training-data=full ACDC | Contrastive Model Adaptation for Cross-Condition Robustness in Semantic SegmentationSource quoteL632: CMA │ 92.4 │ 70.5 │ 88.3 │ 50.4 │ 55.6 │ 56.3 │ 74.8 │ 71.1 │ 90.8 │ 29.4 │ 96.9 │ 77.4 │ 63.5 │ 90.1 │ 63.5 │ 79.6 │ 89.0 │ 45.6 │ 73.9 │ 71.5 |
| 2023 | BTSeg proposed | mean IoU | 70.45 | split: test · semi-supervised-domain-adaptation · backbone=MiT-B5 · resolution=1080×1080 · domain-shift=Cityscapes→ACDC | BTSeg: Barlow Twins Regularization for Domain Adaptation in Semantic SegmentationSource quoteL279: BTSeg (Ours) │ 70.45 │ 92.9 │ 73.5 │ 88.3 │ 53.6 │ 47.2 │ 56.2 │ 67.9 │ 67.3 │ 86.9 │ 61.5 │ 95.3 │ 67.2 │ 46.8 │ 89.1 │ 73.1 │ 81.6 │ 83.1 │ 49.5 │ 57.5 |
| 2023 | CMRformer (CINE sax) (8) proposed | AUC | 0.95 | split: test · input=CINE sax · split_size=100-train/50-test | Multimodal Representation Learning of Cardiovascular Magnetic Resonance ImagingSource quoteL327: Ours (CINE\textsubscript{sax}) (8) │ 0.70 │ 0.95 │ 0.70 |
| 2023 | CISS proposed | mIoU | 69.6% | split: test · unsupervised-domain-adaptation · condition=snow · target-training-data=entire ACDC training set | Condition-Invariant Semantic SegmentationSource quoteL316: CISS (ours) │ 84.1 │ 51.1 │ 91.0 │ 58.6 │ 50.5 │ 58.0 │ 77.5 │ 70.4 │ 91.3 │ 4.7 │ 96.7 │ 78.8 │ 60.3 │ 91.6 │ 71.0 │ 79.1 │ 87.0 │ 51.0 │ 70.5 │ 69.6 |
| 2023 | OVeNet proposed | mIoU | 73.0 | split: test | OVeNet: Offset Vector Network for Semantic SegmentationSource quoteL241: OVeNet │ 95.8 │ 82.1 │ 91.3 │ 55.8 │ 54.6 │ 67.6 │ 80.5 │ 77.3 │ 89.7 │ 69.5 │ 96.8 │ 73.4 │ 39.1 │ 89.5 │ 61.9 │ 65.0 │ 89.4 │ 47.2 │ 60.6 │ 73.0 |
| 2023 | Ours (DG-T), text-prompt prompt randomization proposed | mIoU | 61.2 | split: test · domain-generalization · source-domain=Cityscapes · target-domain=ACDC | Prompting diffusion representations for cross-domain semantic segmentationSource quoteL287: \multirow{2}{*}{DG} │ Ours (DG-T) │ 89.6 │ 62.5 │ 84.4 │ 48.6 │ 39.9 │ 49.2 │ 48.7 │ 55.6 │ 74.5 │ 48.3 │ 86.1 │ 60.3 │ 39.9 │ 84.9 │ 62.6 │ 63.5 │ 73.6 │ 37.7 │ 52.3 │ 61.2 |
| 2023 | VAFA-FR (frequency-consistency adversarial training) proposed non-standard slice | DSC | 73.05 | split: test · q_max=10 · backbone=UNETR · patch_size=32×32×32 · resolution=32x32 · evaluation_attack=VAFA | Frequency Domain Adversarial Training for Robust Volumetric Medical SegmentationSource quoteL244: \multirow{-2}{*}{\rotatebox[origin=c]{90}{\parbox[c]{0.8cm}{\texttt{ACDC}}}} │ \mathcal{M}^{\Scale[0.5]{\text{VAFA-FR}}}_{_{\text{\faShield*}}} │ 83.44 │ 60.63 │ 69.33 │ 60.61 │ 73.05 │ 91.36 │ 85.42 │ 87.42 │ 83.90 │ 91.23 |
| 2023 | CLMR (U-Net) proposed | DI (Dice Index), Ave. | 0.8937 | split: test · backbone=U-Net | Selecting the Best Optimizers for Deep Learning based Medical Image SegmentationSource quoteL224: \multicolumn{1}{|l|}{U-Net} │ 0.8813 │ 0.6708 │ 0.8714 │ 0.8937 |
| 2023 | CLMR (DenseNet_2) proposed | DI (Dice Index), Ave. | 0.9176 | split: test · backbone=DenseNet_2 | Selecting the Best Optimizers for Deep Learning based Medical Image SegmentationSource quoteL226: \multicolumn{1}{|l|}{DenseNet\_2} │ 0.8924 │ 0.7626 │ 0.9064 │ 0.9176 |
| 2023 | HGFormer (Swin-L) proposed | All | 67.2 | split: test · domain-generalization · runs=3 · backbone=Swin-L · training-data=Cityscapes | HGFormer: Hierarchical Grouping Transformer for Domain Generalized Semantic SegmentationSource quoteL191: HGFormer (ours) │ Swin-L │ 69.9 │ 52.7 │ 72.0 │ 68.6 │ 67.2 |
| 2023 | HRNet | mIoU | 70.5 | split: test | OVeNet: Offset Vector Network for Semantic SegmentationSource quoteL239: \multirow{2}{*}{All} │ HRNet │ 95.3 │ 80.3 │ 90.5 │ 52.0 │ 53.1 │ 65.1 │ 78.2 │ 74.2 │ 89.2 │ 68.4 │ 96.7 │ 70.6 │ 36.1 │ 88.2 │ 55.9 │ 54.3 │ 88.0 │ 43.8 │ 58.9 │ 70.5 |
| 2023 | DiffuseMorph baseline | SD(|J|) | 0.178 | split: test | FSDiffReg: Feature-wise and Score-wise Diffusion-guided Unsupervised Deformable Image Registration for Cardiac ImagesSource quoteL202: DiffuseMorph~\cite{kim2022diffusemorph} │ 0.783(0.086) │ 0.678(0.148) │ 0.821(0.067) │ 0.805(0.114) │ 0.061(0.038) │ 0.178 |
| 2023 | CMA baseline | mean IoU | 69.12 | split: test · semi-supervised-domain-adaptation · backbone=MiT-B5 · resolution=1080×1080 · domain-shift=Cityscapes→ACDC | BTSeg: Barlow Twins Regularization for Domain Adaptation in Semantic SegmentationSource quoteL278: CMA \cite{Bruggemann2023CMA} │ 69.12 │ 94.0 │ 75.2 │ 88.6 │ 50.5 │ 45.5 │ 54.9 │ 65.7 │ 64.2 │ 87.1 │ 61.3 │ 95.2 │ 67.0 │ 45.2 │ 86.2 │ 68.6 │ 76.6 │ 84.0 │ 43.3 │ 60.5 |
| 2023 | ConvNext-B (IN-21k) baseline | mIoU | 60.59 | split: test · backbone=ConvNeXt-B · pretraining=ImageNet-21K | Reliability in Semantic Segmentation: Are we on the Right Track?Source quoteL710: ConvNext-B (IN-21k) │ 81.56 │ 65.70 │ 60.59 │ 0.81 │ 5.27 │ 20.07 |
| 2023 | BiT-RN50 (IN-21k) baseline | mIoU | 46.70 | split: test · backbone=BiT-RN50 · pretraining=ImageNet-21K | Reliability in Semantic Segmentation: Are we on the Right Track?Source quoteL712: BiT-RN50 (IN-21k) │ 76.49 │ 57.23 │ 46.70 │ 0.65 │ 5.20 │ 19.63 |
| 2023 | DAFormer (UDA) baseline | mIoU | 55.4 | split: test · unsupervised-domain-adaptation · method=DAFormer · source-domain=Cityscapes · target-domain=ACDC | Prompting diffusion representations for cross-domain semantic segmentationSource quoteL286: DAFormer\cite{hoyer2022daformer} │ 58.4 │ 51.3 │ 84.0 │ 42.7 │ 35.1 │ 50.7 │ 30.0 │ 57.0 │ 74.8 │ 52.8 │ 51.3 │ 58.3 │ 32.6 │ 82.7 │ 58.3 │ 54.9 │ 82.4 │ 44.1 │ 50.7 │ 55.4 |
| 2023 | LCLPL [10] baseline | DSC ↑ | 0.881 | split: test · labeled-data=10% | Pseudo-Label Guided Contrastive Learning for Semi-Supervised Medical Image SegmentationSource quoteL294: 0.881 |
| 2023 | CLR (U-Net) baseline | DI (Dice Index), Ave. | 0.8714 | split: test · backbone=U-Net | Selecting the Best Optimizers for Deep Learning based Medical Image SegmentationSource quoteL224: \multicolumn{1}{|l|}{U-Net} │ 0.8813 │ 0.6708 │ 0.8714 │ 0.8937 |
| 2023 | Adam (U-Net) baseline | DI (Dice Index), Ave. | 0.8813 | split: test · backbone=U-Net | Selecting the Best Optimizers for Deep Learning based Medical Image SegmentationSource quoteL224: \multicolumn{1}{|l|}{U-Net} │ 0.8813 │ 0.6708 │ 0.8714 │ 0.8937 |
| 2023 | CLR (DenseNet_2) baseline | DI (Dice Index), Ave. | 0.9064 | split: test · backbone=DenseNet_2 | Selecting the Best Optimizers for Deep Learning based Medical Image SegmentationSource quoteL226: \multicolumn{1}{|l|}{DenseNet\_2} │ 0.8924 │ 0.7626 │ 0.9064 │ 0.9176 |
| 2023 | Adam (DenseNet_2) baseline | DI (Dice Index), Ave. | 0.8924 | split: test · backbone=DenseNet_2 | Selecting the Best Optimizers for Deep Learning based Medical Image SegmentationSource quoteL226: \multicolumn{1}{|l|}{DenseNet\_2} │ 0.8924 │ 0.7626 │ 0.9064 │ 0.9176 |
| 2023 | Mask2former (Swin-L) baseline | All | 65.0 | split: test · domain-generalization · backbone=Swin-L · training-data=Cityscapes | HGFormer: Hierarchical Grouping Transformer for Domain Generalized Semantic SegmentationSource quoteL190: Mask2former~\cite{mask2former} │ Swin-L │ 69.1 │ 53.1 │ 68.3 │ 65.2 │ 65.0 |
| 2022 | SADM proposed | SSIM ↑ | 0.851 | split: test · resolution=12×128×128×32 | SADM: Sequence-Aware Diffusion Model for Longitudinal Medical Image GenerationSource quoteL246: Ours │ 0.851 │ 28.992 │ 0.153 │ 0.978 │ 31.699 │ 0.090 |
| 2022 | SADM proposed | PSNR ↑ | 28.992 | split: test · resolution=12×128×128×32 | SADM: Sequence-Aware Diffusion Model for Longitudinal Medical Image GenerationSource quoteL246: Ours │ 0.851 │ 28.992 │ 0.153 │ 0.978 │ 31.699 │ 0.090 |
| 2022 | SADM proposed | NRMSE ↓ | 0.153 | split: test · resolution=12×128×128×32 | SADM: Sequence-Aware Diffusion Model for Longitudinal Medical Image GenerationSource quoteL246: Ours │ 0.851 │ 28.992 │ 0.153 │ 0.978 │ 31.699 │ 0.090 |
| 2022 | RoS-FL w/ DWCS proposed | DSC | 0.8799 | split: test · clients=4 · local-epochs=1 · communication-rounds=300 | Robust Split Federated Learning for U-shaped Medical Image NetworksSource quoteL220: RoS-FL w/ DWCS │ 0.8799 │ 2.718 │ 0.8572 │ 0.7932 |
| 2022 | C-CAM proposed | DSC | 80.34% | split: test · weakly-supervised · supervision=image-level | C-CAM: Causal CAM for Weakly Supervised Semantic Segmentation on Medical ImageSource quoteL20: Recently, many excellent weakly supervised semantic segmentation (WSSS) works are proposed based on class activation mapping (CAM). However, there are few works that consider the characteristics of medical images. In this paper, we find that there are mainly two challenges of medical images in WSSS: i) the boundary of object foreground and background is not clear; ii) the co-occurrence phenomenon is very severe in training stage. We thus propose a Causal CAM (C-CAM) method to overcome the above challenges. Our method is motivated by two cause-effect chains including category-causality chain and anatomycausality chain. The category-causality chain represents the image content (cause) affects the category (effect). The anatomy-causality chain represents the anatomical structure (cause) affects the organ segmentation (effect). Extensive experiments were conducted on three public medical image data sets. Our C-CAM generates the best pseudo masks with the DSC of 77.26%, 80.34% and 78.15% on |
| 2022 | BATFormer proposed | Average Dice | 92.84% | split: test · training=2D slice-level · evaluation-unit=patient-level | BATFormer: Towards Boundary-Aware Lightweight Transformer for Efficient Medical Image SegmentationSource quoteL5: Objective: Transformers, born to remedy the inadequate receptive fields of CNNs, have drawn explosive attention recently. However, the daunting computational complexity of global representation learning, together with rigid window partitioning, hinders their deployment in medical image segmentation. This work aims to address the above two issues in transformers for better medical image segmentation. Methods: We propose a boundary-aware lightweight transformer (BATFormer) that can build cross-scale global interaction with lower computational complexity and generate windows flexibly under the guidance of entropy. Specifically, to fully explore the benefits of transformers in long-range dependency establishment, a cross-scale global transformer (CGT) module is introduced to jointly utilize multiple small-scale feature maps for richer global features with lower computational complexity. Given the importance of shape modeling in medical image segmentation, a boundary-aware local transformer (BLT) module is constructed. Different from rigid window partitioning in vanilla transformers which would produce boundary distortion, BLT adopts an adaptive window partitioning scheme under the guidance of entropy for both computational complexity reduction and shape preservation. Results: BATFormer achieves the best performance in Dice of 92.84%, 91.97%, 90.26%, and 96.30% for the average, right ventricle, myocardium, and left ventricle respectively on the ACDC dataset and the best performance in Dice, IoU, and ACC of 90.76%, 84.64%, and 96.76% respectively on the ISIC 2018 dataset. More importantly, BATFormer requires the least amount of model parameters and the lowest computational complexity compared to the state-of-the-art approaches. Conclusion and Significance: Our results demonstrate the necessity of developing customized transformers for efficient and better medical image segmentation. We believe the design of BATFormer is inspiring and extendable to other applications/frameworks. The source code is publicly available at \url{https://github.com/xianlin7/BATFormer}. |
| 2022 | FCT512 proposed | Avg. | 93.13 | split: test · resolution=512×512 · training-data=100 challenge images | The Fully Convolutional Transformer for Medical Image SegmentationSource quoteL426: 93.13 |
| 2022 | U-VPA (Ours(proposed)) proposed | [email protected] | 18.5% | split: test · online-continual-test-time-adaptation · backbone=Faster R-CNN · evaluation=mean across Fog, Night, Rain, and Snow · repetitions=10 · source-dataset=Cityscapes | Cloud-Device Collaborative Adaptation to Continual Changing Environments in the Real-WorldSource quoteL181: Ours(proposed) │ 21.1 │ 9.3 │ 15.7 │ 17.2 │ 24.7 │ 11.8 │ 17.8 │ 20.2 │ 26.3 │ 12.0 │ 18.5 │ 20.6 │ 26.1 │ 12.3 │ 18.0 │ 20.8 │ 18.5 │ +4.4 |
| 2022 | ScaleFormer proposed | DSC | 90.17 | split: test | ScaleFormer: Revisiting the Transformer-based Backbones from a Scale-wise Perspective for Medical Image SegmentationSource quoteL407: 90.17 |
| 2022 | ELSNet proposed | DSC.Avg (class average) | 0.410 | split: test · 1-shot · runs=5 · training-exemplars=1 | Exemplar Learning for Medical Image SegmentationSource quoteL300: 0.410 │ 0.293 │ 0.374 │ 0.563 │ 26.64 │ 47.63 │ 16.58 │ 15.73 |
| 2022 | ELSNet proposed | HD95.Avg (class average) | 26.64 | split: test · 1-shot · runs=5 · training-exemplars=1 | Exemplar Learning for Medical Image SegmentationSource quoteL300: 0.410 │ 0.293 │ 0.374 │ 0.563 │ 26.64 │ 47.63 │ 16.58 │ 15.73 |
| 2022 | SL baseline | DSC | 0.8754 | split: test · clients=4 · local-epochs=1 · communication-rounds=300 | Robust Split Federated Learning for U-shaped Medical Image NetworksSource quoteL211: SL \cite{SplitLearning} │ 0.8754 │ 3.624 │ 1.0272 │ 0.7886 |
| 2022 | UNet^+_F (60×4) baseline | Avg Dice | .889 | split: test · fully-supervised · training-labels=60×4 | Deep Compatible Learning for Partially-Supervised Medical Image SegmentationSource quoteL713: \multicolumn{1}{l|}{UNet^+_F} │ \multicolumn{1}{c|}{60×4} │ .961±.016 │ .881±.026 │ \multicolumn{1}{c|}{.901±.063} │ .908±.063 │ .888±.025 │ .786±.093 │ \multicolumn{1}{|c}{.889} |
| 2022 | Swin-Unet baseline | DSC | 88.07% | split: test · fine-tuned · subset=20 patients · backbone=Swin-Unet | Optimizing Vision Transformers for Medical Image SegmentationSource quoteL134: Swin-Unet │ 88.07 │ 85.77 │ 84.42 │ 94.03 |
| 2022 | Swin-Unet baseline | RV DSC | 85.77% | split: test · fine-tuned · subset=20 patients · backbone=Swin-Unet | Optimizing Vision Transformers for Medical Image SegmentationSource quoteL134: Swin-Unet │ 88.07 │ 85.77 │ 84.42 │ 94.03 |
| 2022 | Fumin Guo baseline | Avg. | 93.02 | split: test | The Fully Convolutional Transformer for Medical Image SegmentationSource quoteL424: 93.02 |
| 2022 | AMS baseline | [email protected] | 17.8% | split: test · online-continual-test-time-adaptation · backbone=Faster R-CNN · evaluation=mean across Fog, Night, Rain, and Snow · repetitions=10 · source-dataset=Cityscapes | Cloud-Device Collaborative Adaptation to Continual Changing Environments in the Real-WorldSource quoteL180: AMS\cite{MehrdadKhani2020RealTimeVI} │ 21.6 │ 9.0 │ 16.0 │ 17.2 │ 23.2 │ 10.7 │ 17.2 │ 19.1 │ 24.7 │ 11.4 │ 17.2 │ 19.9 │ 26.1 │ 11.7 │ 17.8 │ 20.5 │ 17.8 │ +3.7 |
| 2022 | Source-only baseline | [email protected] | 14.1% | split: test · source-only · backbone=Faster R-CNN · adaptation=none · evaluation=mean across Fog, Night, Rain, and Snow · source-dataset=Cityscapes | Cloud-Device Collaborative Adaptation to Continual Changing Environments in the Real-WorldSource quoteL175: Source-only\cite{ShaoqingRen2015FasterRT} │ 20.5 │ 7.4 │ 14.3 │ 14.2 │ 20.5 │ 7.4 │ 14.3 │ 14.2 │ 20.5 │ 7.4 │ 14.3 │ 14.2 │ 20.5 │ 7.4 │ 14.3 │ 14.2 │ 14.1 │ / |
| 2022 | R50 U-Net baseline | DSC | 87.55 | split: test | ScaleFormer: Revisiting the Transformer-based Backbones from a Scale-wise Perspective for Medical Image SegmentationSource quoteL367: 87.55 |
| 2022 | MLDS baseline | DSC.Avg (class average) | 0.189 | split: test · 1-shot · runs=5 · training-exemplars=1 | Exemplar Learning for Medical Image SegmentationSource quoteL298: MLDS\cite{reiss2021every} │ 0.189 │ 0.144 │ 0.165 │ 0.258 │ 50.03 │ 72.13 │ 30.20 │ 47.77 |
| 2022 | MLDS baseline | HD95.Avg (class average) | 50.03 | split: test · 1-shot · runs=5 · training-exemplars=1 | Exemplar Learning for Medical Image SegmentationSource quoteL298: MLDS\cite{reiss2021every} │ 0.189 │ 0.144 │ 0.165 │ 0.258 │ 50.03 │ 72.13 │ 30.20 │ 47.77 |
| 2021 | Ours (KL+Ent) proposed | DSC | 86.94 | split: test · subset=Set-3 · supervision=3 fully labeled images plus 5× as many partially labeled images | Segmentation with mixed supervision: Confidence maximization helps knowledge distillationSource quoteL225: Ours (KL+Ent)* │ \bf \extension{86.94} │ \bf \extension{8.84} |
| 2021 | Ours (KL+Ent) proposed | HD-95 | 8.84 | split: test · subset=Set-3 · supervision=3 fully labeled images plus 5× as many partially labeled images | Segmentation with mixed supervision: Confidence maximization helps knowledge distillationSource quoteL225: Ours (KL+Ent)* │ \bf \extension{86.94} │ \bf \extension{8.84} |
| 2021 | nnFormer proposed | Average DSC | 92.06% | split: test · repeats=10 · data-split=70 train / 10 validation / 20 test | nnFormer: Volumetric Medical Image Segmentation via a 3D TransformerSource quoteL225: nnFormer │ 92.06 │ 90.94 │ 89.58 │ 95.65 |
| 2021 | Adversarial TTT; no continual adaptation proposed non-standard slice | Dice (↑) | 75.0 | split: test | Re-using Adversarial Mask Discriminators for Test-time Training under Distribution ShiftsSource quoteL339: \checkmark │ \ding{55} │ 75.0\textsubscript{09} │ 67.1\textsubscript{10} │ 6.9\textsubscript{05} |
| 2021 | Adversarial TTT with continual adaptation proposed non-standard slice | Dice (↑) | 75.1 | split: test | Re-using Adversarial Mask Discriminators for Test-time Training under Distribution ShiftsSource quoteL340: \hcell{\checkmark} │ \hcell{\checkmark} │ \hcell{\textbf{75.1\textsubscript{09}}} │ \hcell{\textbf{67.2\textsubscript{09}}} │ \hcell{\textbf{6.9\textsubscript{05}}} |
| 2021 | No Adv. TTT; no continual adaptation | Dice (↑) | 74.2 | split: test | Re-using Adversarial Mask Discriminators for Test-time Training under Distribution ShiftsSource quoteL338: \ding{55} │ \ding{55} │ 74.2\textsubscript{10} │ 66.1\textsubscript{10} │ 7.1\textsubscript{05} |
| 2021 | SSCO baseline | DSC | 77.16 | split: test · subset=Set-3 | Segmentation with mixed supervision: Confidence maximization helps knowledge distillationSource quoteL224: \extension{SSCO \citep{Wang2020selfpaced}} * │ \extension{77.16} │ \extension{10.1} |
| 2021 | SSCO baseline | HD-95 | 10.1 | split: test · subset=Set-3 | Segmentation with mixed supervision: Confidence maximization helps knowledge distillationSource quoteL224: \extension{SSCO \citep{Wang2020selfpaced}} * │ \extension{77.16} │ \extension{10.1} |
| 2021 | Source model (DeepLabv2) baseline | mIoU | 38.0 | split: test · conditions=all four · source-domain=Cityscapes · target-domain=ACDC | ACDC: The Adverse Conditions Dataset with Correspondences for Semantic Driving Scene UnderstandingSource quoteL103: Source model~\cite{DeepLab:v2} │ 71.9 │ 26.2 │ 51.1 │ 18.8 │ 22.5 │ 19.7 │ 33.0 │ 27.7 │ 67.9 │ 28.6 │ 44.2 │ 43.1 │ 22.1 │ 71.2 │ 29.8 │ 33.3 │ 48.4 │ 26.2 │ 35.8 │ 38.0 |
| 2021 | FDA baseline | mIoU | 45.7 | split: test · unsupervised-domain-adaptation · conditions=all four · source-domain=Cityscapes · target-domain=ACDC | ACDC: The Adverse Conditions Dataset with Correspondences for Semantic Driving Scene UnderstandingSource quoteL109: FDA~\cite{fda:adaptation} │ 73.2 │ 34.7 │ 59.0 │ 24.8 │ 29.5 │ 28.6 │ 43.3 │ 44.9 │ 70.1 │ 28.2 │ 54.7 │ 47.0 │ 28.5 │ 74.6 │ 44.8 │ 52.3 │ 63.3 │ 28.3 │ 39.5 │ 45.7 |
| 2021 | HRNet baseline | mIoU | 75.0% | split: test · supervised · backbone=HRNet · conditions=all | ACDC: The Adverse Conditions Dataset with Correspondences for Semantic Driving Scene UnderstandingSource quoteL203: HRNet~\cite{hrnet} │ 95.3 │ 79.9 │ 90.7 │ 53.7 │ 57.4 │ 65.9 │ 78.4 │ 75.9 │ 88.8 │ 68.6 │ 96.1 │ 75.5 │ 54.0 │ 91.2 │ 68.2 │ 76.2 │ 85.4 │ 58.4 │ 65.1 │ 75.0 |
| 2021 | LeViT-UNet-384s baseline | Average DSC | 90.32% | split: test · repeats=10 · data-split=70 train / 10 validation / 20 test | nnFormer: Volumetric Medical Image Segmentation via a 3D TransformerSource quoteL222: LeViT-UNet-384s~\cite{xu2021levit} │ 90.32 │ 89.55 │ 87.64 │ 93.76 |
| 2020 | Adv Bias (proposed) proposed | Average Dice score | 0.686 | split: test · semi-supervised · labeled-subjects=1 | Realistic Adversarial Data Augmentation for MR Image SegmentationSource quoteL125: In the supervised learning setting (no access to unlabelled images), when only one or three labelled subject was available, the proposed method clearly outperformed all baseline methods. For semi-supervised learning, the proposed methods outperformed VAT, especially when only one labelled subject is available (0.686 vs 0.625). The proposed method achieves competitive results compared to the semi-supervised GAN-based method (cGANs) as well. Of note, cGANs adopts two additional GANs to sample geometric transformations and intensity transformations from unlabelled images. This is why it was only compared in the semi-supervised learning setting here. On the contrary, our approach is applicable to both low-shot supervised learning and semi-supervised learning. In addition, cGANs contains more parameters than our method and thus it might be less computationally efficient. |
| 2020 | G^D encoder + random-initialized decoder proposed | Mean Dice score (DSC) | 0.784 | split: test · fine-tuned · decoder=random-initialized · labeled-volumes=2 | Contrastive learning of global and local features for medical image segmentation with limited annotationsSource quoteL494: {G (D)} │ {random init} │ ACDC │ \multicolumn{3}{|l|}{0.691} │ \multicolumn{3}{|l|}{0.784} │ \multicolumn{3}{|l|}{0.870} |
| 2020 | Ours (KL+Ent), bottom branch proposed | DSC | 75.92 | split: test · branch=bottom · subset=Set-3 · supervision=full and partial | Teach Me to Segment with Mixed Supervision: Confident Students Become MastersSource quoteL111: Ours (KL+Ent) │ \checkmark │ \checkmark │ 69.25 │ 49.93 │ \bf 75.92 │ \bf 30.12 |
| 2020 | Ours (KL+Ent), bottom branch proposed | DSC | 78.77 | split: test · branch=bottom · subset=Set-5 · supervision=full and partial | Teach Me to Segment with Mixed Supervision: Confident Students Become MastersSource quoteL118: Ours (KL+Ent) │ \checkmark │ \checkmark │ 67.10 │ 45.28 │ \bf 78.77 │ \bf 23.29 |
| 2020 | Ours (KL+Ent), bottom branch proposed | DSC | 88.07 | split: test · branch=bottom · subset=Set-10 · supervision=full and partial | Teach Me to Segment with Mixed Supervision: Confident Students Become MastersSource quoteL125: Ours (KL+Ent) │ \checkmark │ \checkmark │ 83.96 │ 30.71 │ \bf 88.07 │ \bf 4.37 |
| 2020 | Res U-net+bi-ConvLSTM (our framework) proposed | MYO-Dice | 0.7260 | split: test · phase=ED | Myocardial Segmentation of Cardiac MRI Sequences With Temporal Consistency for Coronary Artery Disease DiagnosisSource quoteL220: our framework │ 0.8967 │ 0.8146 │ 0.7260 │ 0.5587 │ 0.8133 │ 0.7080 │ 0.7656 │ 0.4231 |
| 2020 | Res U-net+bi-ConvLSTM (our framework) proposed | MYO-Dice | 0.7656 | split: test · phase=ES | Myocardial Segmentation of Cardiac MRI Sequences With Temporal Consistency for Coronary Artery Disease DiagnosisSource quoteL220: our framework │ 0.8967 │ 0.8146 │ 0.7260 │ 0.5587 │ 0.8133 │ 0.7080 │ 0.7656 │ 0.4231 |
| 2020 | Ours (KL), bottom branch ablation | DSC | 63.98 | split: test · branch=bottom · subset=Set-3 · supervision=full and partial | Teach Me to Segment with Mixed Supervision: Confident Students Become MastersSource quoteL109: Ours (KL) │ \checkmark │ \checkmark │ 56.39 │ 63.27 │ 63.98 │ 67.67 |
| 2020 | Ours (KL), bottom branch ablation | DSC | 72.69 | split: test · branch=bottom · subset=Set-5 · supervision=full and partial | Teach Me to Segment with Mixed Supervision: Confident Students Become MastersSource quoteL116: Ours (KL) │ \checkmark │ \checkmark │ 67.96 │ 44.01 │ 72.69 │ 40.75 |
| 2020 | Ours (KL), bottom branch ablation | DSC | 82.21 | split: test · branch=bottom · subset=Set-10 · supervision=full and partial | Teach Me to Segment with Mixed Supervision: Confident Students Become MastersSource quoteL123: Ours (KL) │ \checkmark │ \checkmark │ 80.60 │ 27.19 │ 82.21 │ 33.96 |
| 2020 | VAT baseline | Average Dice score | 0.625 | split: test · semi-supervised · labeled-subjects=1 | Realistic Adversarial Data Augmentation for MR Image SegmentationSource quoteL125: In the supervised learning setting (no access to unlabelled images), when only one or three labelled subject was available, the proposed method clearly outperformed all baseline methods. For semi-supervised learning, the proposed methods outperformed VAT, especially when only one labelled subject is available (0.686 vs 0.625). The proposed method achieves competitive results compared to the semi-supervised GAN-based method (cGANs) as well. Of note, cGANs adopts two additional GANs to sample geometric transformations and intensity transformations from unlabelled images. This is why it was only compared in the semi-supervised learning setting here. On the contrary, our approach is applicable to both low-shot supervised learning and semi-supervised learning. In addition, cGANs contains more parameters than our method and thus it might be less computationally efficient. |
| 2020 | Res U-net baseline | MYO-Dice | 0.7178 | split: test · phase=ED | Myocardial Segmentation of Cardiac MRI Sequences With Temporal Consistency for Coronary Artery Disease DiagnosisSource quoteL218: Res U-net\cite{ronneberger2015u} │ 0.8856 │ 0.8073 │ 0.7178 │ 0.5583 │ 0.8050 │ 0.6841 │ 0.7554 │ 0.4053 |
| 2020 | Res U-net baseline | MYO-Dice | 0.7554 | split: test · phase=ES | Myocardial Segmentation of Cardiac MRI Sequences With Temporal Consistency for Coronary Artery Disease DiagnosisSource quoteL218: Res U-net\cite{ronneberger2015u} │ 0.8856 │ 0.8073 │ 0.7178 │ 0.5583 │ 0.8050 │ 0.6841 │ 0.7554 │ 0.4053 |
| 2019 | Isensee et al. 2D U-net + 3D U-net ensemble baseline | Dice | 0.950 | split: test · structure=LV | Deep learning for cardiac image segmentation: A reviewSource quoteL229: Methods │ Description │ LV │ Myo │ RV \cite{Isensee_2017_STACOM} │ 2D U-net +3D U-net (ensemble) │ 0.950 │ 0.911 │ 0.923 |
| 2019 | Isensee et al. 2D U-net + 3D U-net ensemble baseline | Dice | 0.911 | split: test · structure=Myo | Deep learning for cardiac image segmentation: A reviewSource quoteL229: Methods │ Description │ LV │ Myo │ RV \cite{Isensee_2017_STACOM} │ 2D U-net +3D U-net (ensemble) │ 0.950 │ 0.911 │ 0.923 |
| 2019 | Isensee et al. 2D U-net + 3D U-net ensemble baseline | Dice | 0.923 | split: test · structure=RV | Deep learning for cardiac image segmentation: A reviewSource quoteL229: Methods │ Description │ LV │ Myo │ RV \cite{Isensee_2017_STACOM} │ 2D U-net +3D U-net (ensemble) │ 0.950 │ 0.911 │ 0.923 |
| 2019 | Li et al. two 2D FCNs for ROI detection and segmentation baseline | Dice | 0.944 | split: test · structure=LV | Deep learning for cardiac image segmentation: A reviewSource quoteL230: \cite{Li_2019_ISBI} │ Two 2D FCNs for ROI detection and segmentation respectively; │ 0.944 │ 0.911 │ 0.926 |
| 2019 | Li et al. two 2D FCNs for ROI detection and segmentation baseline | Dice | 0.911 | split: test · structure=Myo | Deep learning for cardiac image segmentation: A reviewSource quoteL230: \cite{Li_2019_ISBI} │ Two 2D FCNs for ROI detection and segmentation respectively; │ 0.944 │ 0.911 │ 0.926 |
| 2019 | Li et al. two 2D FCNs for ROI detection and segmentation baseline | Dice | 0.926 | split: test · structure=RV | Deep learning for cardiac image segmentation: A reviewSource quoteL230: \cite{Li_2019_ISBI} │ Two 2D FCNs for ROI detection and segmentation respectively; │ 0.944 │ 0.911 │ 0.926 |
| 2018 | Base + CRF-RNN (scribble-supervised) proposed | Mean Dice | 0.880 | split: test · scribble-supervised · training-dimension=2D slices | Learning to Segment Medical Images with Scribble-Supervision AloneSource quoteL121: Base + CRF-RNN │ 0.915 │ 0.885 │ 0.840 │ 0.880 │ 0.698 │ 0.863 │ 0.781 |
| 2018 | Fully supervised baseline | Mean Dice | 0.912 | split: test · fully-supervised · training-dimension=2D slices | Learning to Segment Medical Images with Scribble-Supervision AloneSource quoteL126: Fully supervised │ 0.935 │ 0.905 │ 0.895 │ 0.912 │ 0.746 │ 0.889 │ 0.818 |
| 2017 | 2D/3D UNet ensemble proposed | Dice score, LVC | 0.950 | split: test · method=2D/3D UNet ensemble · structure=LVC | Automatic Cardiac Disease Assessment on cine-MRI via Time-Series Segmentation and Domain Specific FeaturesSource quoteL12: 0.908 (RVC) and 0.905 (LVM) in a cross-validation over the training set (100 cases) and 0.950 (LVC), 0.923 (RVC) and 0.911 (LVM) on the test set (50 cases). We report a classification accuracy of 94% on a training set cross-validation and 92% on the test set. Our results underpin the potential of machine learning methods for accurate, fast and reproducible segmentation and computer-assisted diagnosis (CAD). |
| 2017 | 2D/3D UNet ensemble proposed | Dice score, RVC | 0.923 | split: test · method=2D/3D UNet ensemble · structure=RVC | Automatic Cardiac Disease Assessment on cine-MRI via Time-Series Segmentation and Domain Specific FeaturesSource quoteL12: 0.908 (RVC) and 0.905 (LVM) in a cross-validation over the training set (100 cases) and 0.950 (LVC), 0.923 (RVC) and 0.911 (LVM) on the test set (50 cases). We report a classification accuracy of 94% on a training set cross-validation and 92% on the test set. Our results underpin the potential of machine learning methods for accurate, fast and reproducible segmentation and computer-assisted diagnosis (CAD). |
| 2017 | 2D/3D UNet ensemble proposed | Dice score, LVM | 0.911 | split: test · method=2D/3D UNet ensemble · structure=LVM | Automatic Cardiac Disease Assessment on cine-MRI via Time-Series Segmentation and Domain Specific FeaturesSource quoteL12: 0.908 (RVC) and 0.905 (LVM) in a cross-validation over the training set (100 cases) and 0.950 (LVC), 0.923 (RVC) and 0.911 (LVM) on the test set (50 cases). We report a classification accuracy of 94% on a training set cross-validation and 92% on the test set. Our results underpin the potential of machine learning methods for accurate, fast and reproducible segmentation and computer-assisted diagnosis (CAD). |