ACDC

242 papers · 564 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching regime=semi-supervised.

76.881.586.290.9202220242025MC-Net+: 87.1 (2022)MC-Net+: 88.51 (2022)ACTION: 86.7 (2022)ACTION: 89.7 (2022)ACTION: 89.8 (2022)DCPA: 85.86 (2023)Cross-ALD: 80.6 (2023)AdvMIM: 85.4 (2025)TransMedSeg: 89.96 (2025)AugPaint: 42.42 (2025)AugPaint: 77.73 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 86 of 86 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026SDT-Net proposedAverage Dice score90.8%split: testScribble-Supervised Medical Image Segmentation With Dynamic Teacher Switching and Hierarchical Consistency
Source quote
L143: Ours │ 93.5 │ 89.3 │ 89.6 │ 90.8
2026EvoML proposedDice0.919split: test · supervisedValidation-Gated ML Pipeline Synthesis with Expert-Grounded Self-Evolving Skills
Source quote
L1410: 0.919
2026ProGeo-RC proposed95HD1.54split: testProGeo-RC: Prototype-guided Semantic Reliability and Geometric Error Calibration for Semi-supervised Cardiac Image Segmentation
Source quote
L959: 1.54
2026ProGeo-RC proposedASD0.57split: testProGeo-RC: Prototype-guided Semantic Reliability and Geometric Error Calibration for Semi-supervised Cardiac Image Segmentation
Source quote
L960: 0.57
2026AutoMedImg-Claude-4.5-Opus proposedDice0.9041split: test · supervised · trials=Pass@3 · modality=MRI · dimension=3DTowards Fully Automated Medical Imaging Code Generation via Validation-based Context Engineering
Source quote
L376: \texttt{AutoMedImg-Claude-4.5-Opus} │ 0 │ 0.8185 │ 0 │ 0.9041 │ 0 │ 0.7696 │ 0 │ 0.8789 │ 0 │ 0.9517 │ 0 │ 0.9938
2026HeuSCM (HRDA backbone) proposedmIoU72.9%split: test · domain-adaptation · backbone=HRDA · domain-transfer=Cityscapes→ACDCHeuristic Self-Paced Learning for Domain Adaptive Semantic Segmentation under Adverse Conditions
Source quote
L306: The quantitative results of mIoU performances on the ACDC test set and the ACDC val set are reported in Table~\ref{t:acdctest} and Table~\ref{t:acdctval}, respectively. We observe that our method consistently outperforms existing approaches across different backbones on both the ACDC test and validation sets. Notably, when built upon the HRDA backbone, our method achieves mIoU scores of 72.9 and 72.7 mIoU [%] on the ACDC test and val sets, respectively, establishing state-of-the-art performance for Cityscapes \rightarrow ACDC domain adaptation.
2025SSS proposedDice coefficient89.34%split: testSSS: Semi-Supervised SAM-2 with efficient prompting for medical imaging segmentation
Source quote
L239: \subsubsection{Automated Cardiac Diagnosis Challeng (ACDC).} Table~\ref{tab2} reports the quantitative evaluation results of the proposed SSS on the ACDC dataset and systematically compares it with current state-of-the-art semi-supervised segmentation methods. The evaluation is performed under two different supervision settings, using 3% and 10% labeled data, simulating real clinical scenarios with extremely scarce annotated data. The results demonstrate that the SSS method excels across all evaluation metrics, significantly outperforming existing comparison methods. Under the 3% labeled data setting, SSS achieves a Dice score of 89.34, a Jaccard index of 82.20, a 95% Hausdorff Distance (95HD) of 1.42, and an Average Surface Distance (ASD) of 0.43. When using 10% labeled data, all metrics improve further to 91.21, 82.97, 1.30, and 0.31, respectively. These results fully validate the robustness and superior segmentation performance of the proposed method under low-supervision conditions. As a multi-class segmentation model, it achieved a Dice score of 44.50 ± 0.17 under the same settings. This further highlights the adaptability and superiority of our method across different tasks.
2025CLFSeg (17 filters) proposedDSC0.9522split: testCLFSeg: A Fuzzy-Logic based Solution for Boundary Clarity and Uncertainty Reduction in Medical Image Segmentation
Source quote
L368: In the cardiac segmentation task on the ACDC dataset, CLFSeg match the performance with baseline \cite{dumitru2023using} for 17 and 34 filters. But exceeded the performance of recent models such as Duck-Net and Adaptive t-vMF for 17 filters, reaching a DSC of 0.9522 and IoU of 0.9087 while reducing computational complexity by up to 30% as shown in Table \ref{table:CLFSeg_ACDC_Results}.
2025Self-Prompt-SAM proposedAverage DSC93.26%split: test · backbone=SAMSelf-Prompt SAM: Medical Image Segmentation via Automatic Prompt SAM Adaptation
Source quote
L157: Self-Prompt-SAM (Ours) │ 93.26 │ 92.20 │ 91.22 │ 96.36
2025SURGEON proposedMean online error42.2%split: test · test-time-adaptation · backbone=SegFormer-B5 · conditions=Fog, Night, Rain, Snow · timestamps=1, 4, 7, 10SURGEON: Memory-Adaptive Fully Test-Time Adaptation via Dynamic Activation Sparsity
Source quote
L299: \multicolumn{1}{l|}{} │ Surgeon │ 30.9 │ 59.7 │ 40.0 │ 42.2 │ 30.4 │ 59.1 │ 39.1 │ 41.7 │ 30.0 │ 58.7 │ 38.3 │ 41.3 │ 29.7 │ 58.3 │ 37.9 │ 41.0 │ 42.2 │ 380
2025SURGEON proposedCache size380 MBsplit: test · test-time-adaptation · backbone=SegFormer-B5 · conditions=Fog, Night, Rain, Snow · timestamps=1, 4, 7, 10SURGEON: Memory-Adaptive Fully Test-Time Adaptation via Dynamic Activation Sparsity
Source quote
L299: \multicolumn{1}{l|}{} │ Surgeon │ 30.9 │ 59.7 │ 40.0 │ 42.2 │ 30.4 │ 59.1 │ 39.1 │ 41.7 │ 30.0 │ 58.7 │ 38.3 │ 41.3 │ 29.7 │ 58.3 │ 37.9 │ 41.0 │ 42.2 │ 380
2025IntelliCardiac (Ours w/ ROI; final classification after expert refinement) proposedoverall accuracy98%split: test · method=ROI with expert SVM refinement for ambiguous cases · subset=50 evaluation patientsIntelliCardiac: An Intelligent Platform for Cardiac Image Segmentation and Classification
Source quote
L205: Ours (w/ ROI) │ 92.56 │ 92.27 │ 90.33 │ 95.09 │ 92% / 98%
2025MedSegFactory proposedFID158.11split: test · generated-set-size=matched to test setMedSegFactory: Text-Guided Generation of Medical Image-Mask Pairs
Source quote
L223: MedSegFactory │ 158.11 │ 3.51 │ 156.97 │ 2.44 │ 227.88 │ 2.43
2025MedSegFactory proposedDSC88.02%split: test · trained-on-generated-data · segmentation-model=nnUNetMedSegFactory: Text-Guided Generation of Medical Image-Mask Pairs
Source quote
L261: MedSegFactory │ 88.02 │ 81.50 │ 83.38 │ 78.75 │ 90.85 │ 86.61
2025SparseMamba-PCL proposedDice89.15%split: test · scribble-supervised · cross-validation=5-foldSparseMamba-PCL: Scribble-Supervised Medical Image Segmentation via SAM-Guided Progressive Collaborative Learning
Source quote
L162: SparseMamba-PCL │ 89.15 │ 5.49 │ 73.84 │ 16.77 │ 82.13 │ 41.79
2025CENet proposedaDSC92.18%split: test · epochs=100CENet: Context Enhancement Network for Medical Image Segmentation
Source quote
L146: CENet │ \textcolor{blue}{92.18} │ \textcolor{blue}{90.90} │ \textcolor{blue}{89.63} │ \textcolor{blue}{95.99}
2025AstMatch proposedDSC (%)90.47%split: test · backbone=2D U-Net · labeled-fraction=10%AstMatch: Adversarial self-training consistency framework for semi-supervised medical image segmentation
Source quote
L1306: 90.47
2025WMREN proposedAvg. DSC92.12%split: test · resolution=224×224Wavelet Multi-scale Region-Enhanced Network for Medical Image Segmentation
Source quote
L404: Tables 2 and 3 show the results on ACDC and ISIC17 datasets, respectively. WMREN also performs the best on these datasets. Our method achieves a leading average DSC of 92.12% on ACDC dataset and 87.67% on ISIC17 dataset, demonstrating the superiority of the proposed method.
2025Sim-MPNet proposedDSC92.18%split: testSimilarity Memory Prior is All You Need for Medical Image Segmentation
Source quote
L169: ACDC. ACDC datasets test the model's ability to explore local details, and ViT-based methods are often difficult to achieve better segmentation results. \Cref{table1} shows that the DSC of SwinUNet, TransDeepLab and DAE-Former does not exceed 90%. Although the hybrid CNN-ViT methods partially compensate for the shortcomings of ViT, its highest DSC is only 91.48%. In contrast, Sim-MPNet can directly capture the category features of organs in ACDC by dynamic memory prior mechanism, thus achieving 92.18% DSC and acquiring better segmentation results.
2024HResFormer (table label: Ours) proposedDSC91.88split: testHResFormer: Hybrid Residual Transformer for Volumetric Medical Image Segmentation
Source quote
L361: Ours │ 91.88 │ 90.44 │ 89.50 │ 95.79
2024MemWarp proposedAverage Dice89.61%split: test · semi-supervised · inference-masks=not-requiredMemWarp: Discontinuity-Preserving Cardiac Registration with Memorized Anatomical Filters
Source quote
L185: MemWarp (ours) │ 89.61 │ 89.30 │ 86.49 │ 93.04 │ 3.93 │ 0.149
2024MemWarp proposedHD953.93 mmsplit: test · semi-supervised · inference-masks=not-requiredMemWarp: Discontinuity-Preserving Cardiac Registration with Memorized Anatomical Filters
Source quote
L185: MemWarp (ours) │ 89.61 │ 89.30 │ 86.49 │ 93.04 │ 3.93 │ 0.149
2024CorrMLP proposedDSC0.810split: testCorrelation-aware Coarse-to-fine MLPs for Deformable Medical Image Registration
Source quote
L431: 0.810
2024SNet proposedAverage Dice91.55%split: test · aggregation=average across RV, Myo, and LVRethinking Information Loss in Medical Image Segmentation with Various-sized Targets
Source quote
L345: SNet (ours) │ 90.56 │ 89.61 │ 94.47 │ 91.55
2024LoG-VMamba (3D U-Mamba-Enc-based model) proposedDice92.18%split: test · backbone=3D U-Mamba-EncLoG-VMamba: Local-Global Vision Mamba for Medical Image Segmentation
Source quote
L259: Ours │ 59.7M │ 467.9G │ \subbest{92.18-±0.13} │ \subbest{1.10-±0.00}
2024LoG-VMamba (3D U-Mamba-Enc-based model) proposedHD951.10 mmsplit: test · backbone=3D U-Mamba-EncLoG-VMamba: Local-Global Vision Mamba for Medical Image Segmentation
Source quote
L259: Ours │ 59.7M │ 467.9G │ \subbest{92.18-±0.13} │ \subbest{1.10-±0.00}
2024ControlUDA proposedmIoU71.6split: test · adaptation=Cityscapes-to-ACDC · weak-supervision=no extra clear reference imagesControlUDA: Controllable Diffusion-assisted Unsupervised Domain Adaptation for Cross-Weather Semantic Segmentation
Source quote
L175: {\bf Benchmark Evaluation} We evaluate ControlUDA and compare it with SOTA methods for domain adaptive semantic segmentation in adverse conditions. As shown in Table~\ref{tab:citytoacdc}, ControlUDA shows superior performance to the SOTA methods on test set of Cityscapes-to-ACDC adaptation, pushing the upper bound of this unsupervised task further and obtaining 71.6 mIoU even without any weak supervision from reference data. An visual impression is given in Fig.\ref{fig:seg_output}. The superiority of ControlUDA is also verified on the val sets of the benchmarks (shown in Table~\ref{tab:val_city2acdcdz}), and it achieves 71.8 and 47.6 mIoU respectively, outperforming SOTA methods by considerable margins.
2024DRDM augmentation + vanilla U-Net proposedAverage DSC68.2%split: test · 5-shot · backbone=vanilla U-Net · augmentation=DRDM · labeled-subjects=5 (5%)Deformation-Recovery diffusion model (DRDM): Instance deformation for image manipulation and synthesis
Source quote
L556: DRDM │ 77.0 │ {73.7} │ 84.1 │ 59.6 │ 55.8 │ 77.3 │ 67.9 │ 68.5 │ 73.4 │ 68.2 │ 66.0 │ 78.3
2024SemSim proposedDSC0.872split: test · semi-supervised · labeled-data=1% (1 case)SemSim: Revisiting Weak-to-Strong Consistency from a Semantic Similarity Perspective for Semi-supervised Medical Image Segmentation
Source quote
L361: SemSim │ {\color[HTML]{FF0000}0.872} │ {\color[HTML]{FF0000}1.8} │ {\color[HTML]{FF0000}0.888} │ {\color[HTML]{FF0000}1.9} │ {\color[HTML]{FF0000}0.896} │ {\color[HTML]{FF0000}2.3} │ 2.60
2024SemSim proposed95HD1.8 mmsplit: test · semi-supervised · labeled-data=1% (1 case)SemSim: Revisiting Weak-to-Strong Consistency from a Semantic Similarity Perspective for Semi-supervised Medical Image Segmentation
Source quote
L361: SemSim │ {\color[HTML]{FF0000}0.872} │ {\color[HTML]{FF0000}1.8} │ {\color[HTML]{FF0000}0.888} │ {\color[HTML]{FF0000}1.9} │ {\color[HTML]{FF0000}0.896} │ {\color[HTML]{FF0000}2.3} │ 2.60
20242D AgileFormer proposedaverage DSC92.55%split: test · dimension=2D · resolution=224×224AgileFormer: Spatially Agile Transformer UNet for Medical Image Segmentation
Source quote
L252: One the ACDC dataset, AgileFormer achieved an average DSC (%) of 92.55, surpassing all the baseline methods in segmenting RV, Myo, and LV (see~\Cref{tab:ACDC}; 2D Models).
2024CCT-R (mean, Affine) proposedDSC80.4%split: test · fusion=mean logits · registration=affine · labeled_cases=1 · labeled_fraction=1.4%Learning Semi-Supervised Medical Image Segmentation from Spatial Registration
Source quote
L592: Ours (mean, Affine) │ \bf{80.4} │ \bf{3.5} │ \bf{78.3} │ \bf{3.2} │ \bf{83.6} │ 4.3 │ 79.3 │ \bf{2.9}
2024CCT-R (mean, Affine) proposedHD3.5 mmsplit: test · fusion=mean logits · registration=affine · labeled_cases=1 · labeled_fraction=1.4%Learning Semi-Supervised Medical Image Segmentation from Spatial Registration
Source quote
L592: Ours (mean, Affine) │ \bf{80.4} │ \bf{3.5} │ \bf{78.3} │ \bf{3.2} │ \bf{83.6} │ 4.3 │ 79.3 │ \bf{2.9}
2024Hybrid-TTA proposedAverage frame rate1.16 fpssplit: test · continual-test-time-adaptation · rounds=3 · source-domain=CityscapesHybrid-TTA: Continual Test-time Adaptation via Dynamic Domain Shift Detection
Source quote
L271: Frame rate (fps \uparrow ) │ 0.058 │ 0.043 │ 1.16
2024Proposed multitask learning (MTL; relative orientation and relative location regression) proposed non-standard sliceAUC0.839split: test · fine-tuned · subset=1 subject · classifier=100-tree random forestSelf-supervised learning for medical image data with anatomy-oriented imaging planes
Source quote
L495: MTL │ 0.839 │ 0.903 │ 0.959 │ 0.959 │ 0.972
2024CPA-Enhancer + SegFormer (Ours(S)) proposedmIoU72.2%split: test · backbone=SegFormerCPA-Enhancer: Chain-of-Thought Prompted Adaptive Enhancer for Object Detection under Unknown Degradations
Source quote
L520: We present quantitative comparisons on the ACDC test set, and corresponding results are provided in \cref{tab:seg}. As expected, our model continues to achieve the best result with a mIoU of 72.2%, substantially outperforming the previous best result (Refign\cite{refign}) by 6.7 points. For convincing evidence, we further show the visual quality comparisons in \cref{fig:app_seg}. Our CPA-Enhancer consistently outperforms Refine in terms of generating more precise segmentation maps under different degradation types, indicating the versatility and robustness of our approach in handling visual tasks under multiple unknown degradations.
2024ScribbleVS proposedaverage Dice90.6%split: test · scribble-supervised · supervision=scribbleScribbleVS: Scribble-Supervised Medical Image Segmentation via Dynamic Competitive Pseudo Label Selection
Source quote
L181: Specifically, our method outperforms DMSPS-stage2. On the ACDC dataset, it achieves a 0.8% improvement over DMSPS-stage2 (90.6% vs 89.8%), while on the MSCMRseg dataset, it achieves a 1.0% improvement compared to DMSPS-stage1 (88.7% vs 87.7%).
2024Ours (ResNet) proposedmIoU55.95%split: test · backbone=ResNet · aggregation=mean across Fog, Night, Rain, and Snow · training-data=CityscapesGeneralize or Detect? Towards Robust Semantic Segmentation Under Multiple Distribution Shifts
Source quote
L433: Ours │ 74.84 │ 30.33 │ 61.15 │ 57.80 │ 55.95 ISSA\cite{ISSA} │ \multirow{3}{*}{Mask2Former} │ 67.5 │ 33.2 │ 55.9 │ 53.2 │ 52.5
2024Ours-ABD (BCP) proposedDSC↑89.81split: test · semi-supervisedAdaptive Bidirectional Displacement for Semi-Supervised Medical Image Segmentation
Source quote
L505: 89.81
2024Ours-ABD (BCP) proposed95HD↓1.46split: test · semi-supervisedAdaptive Bidirectional Displacement for Semi-Supervised Medical Image Segmentation
Source quote
L507: 1.46
2024Ours-ABD (BCP) proposedASD↓0.49split: test · semi-supervisedAdaptive Bidirectional Displacement for Semi-Supervised Medical Image Segmentation
Source quote
L508: 0.49
2024DeNAS-ViT proposedDSC0.915split: test · semi-supervised-15-labeled · resolution=224×224 · labeled-data=15%DeNAS-ViT: Data Efficient NAS-Optimized Vision Transformer for Ultrasound Image Segmentation
Source quote
L380: DeNAS-ViT │ \boldsymbol{0.890} ({\textbf{\textcolor{iccvblue}{+0.059}}}) │ \boldsymbol{3.356} (\textbf{\textcolor{iccvblue}{-7.265}}) │ \boldsymbol{0.915} (\textbf{\textcolor{iccvblue}{+0.064}}) │ \boldsymbol{1.677} (\textbf{\textcolor{iccvblue}{-5.627}})
2024UniA proposedConfusion ratio (CR; FP/TP)0.21split: test · subset=25 casesTackling Ambiguity from Perspective of Uncertainty Inference and Affinity Diversification for Weakly Supervised Semantic Segmentation
Source quote
L417: We also implement it on medical datastet ACDC, which features ambiguity (low contrast and similar textures). Confusion ratio (CR) and DSC are selected as the metrics to evaluate. As reported in Table~\ref{table.6}, incapable of inferring the ambiguous region, ToCo~\cite{24} achieves 80.36% DSC and 0.49 confusion ratio. Compared to it, UniA is more competent at tackling ambiguous images. Our method achieves better DSC of 83.75% and CR of 0.21, which significantly outperforms ToCo by 28% in CR and even surpasses counterparts specially designed for medical images~\cite{46}.
2024M-CnT proposedDSC0.753split: test · semi-supervised · labeled-data=3%Combinatorial CNN-Transformer Learning with Manifold Constraints for Semi-supervised Medical Image Segmentation
Source quote
L318: 0.753
2024SND proposedIoU48.1%split: test · backbone=DeepLab-v2 with ResNet-101 · adaptation=source-free domain adaptation · domain-shift=Cityscapes to ACDC; clean to adverse weatherStable Neighbor Denoising for Source-free Domain Adaptive Segmentation
Source quote
L254: SND (Ours) │ 74.8 │ 27.6 │ 69.3 │ 23.6 │ 26.3 │ 36.5 │ 52.8 │ 54.6 │ 75.5 │ 35.0 │ 84.8 │ 52.5 │ 25.5 │ 78.8 │ 44.9 │ 48.1 │ 37.6 │ 31.1 │ 34.9 │ 48.1
2024FATNet + DTMFormer proposedAverage Dice92.53split: testDTMFormer: Dynamic Token Merging for Boosting Transformer-Based Medical Image Segmentation
Source quote
L295: 92.53
2023CMA (SegFormer) proposedmean IoU61.3split: test · backbone=SegFormer · condition=night · source-dataset=Cityscapes · target-training-data=full ACDCContrastive Model Adaptation for Cross-Condition Robustness in Semantic Segmentation
Source quote
L600: CMA │ 95.2 │ 77.5 │ 84.3 │ 43.9 │ 30.9 │ 49.4 │ 52.0 │ 49.6 │ 74.2 │ 51.2 │ 78.4 │ 61.4 │ 41.2 │ 79.2 │ 63.6 │ 75.1 │ 75.8 │ 34.6 │ 47.3 │ 61.3
2023CMA (SegFormer) proposedmean IoU72.5split: test · backbone=SegFormer · condition=rain · source-dataset=Cityscapes · target-training-data=full ACDCContrastive Model Adaptation for Cross-Condition Robustness in Semantic Segmentation
Source quote
L616: CMA │ 93.3 │ 76.3 │ 92.8 │ 58.1 │ 58.2 │ 61.2 │ 70.4 │ 71.8 │ 93.8 │ 45.0 │ 97.9 │ 67.4 │ 36.8 │ 89.7 │ 72.2 │ 88.5 │ 86.4 │ 50.5 │ 66.7 │ 72.5
2023CMA (SegFormer) proposedmean IoU71.5split: test · backbone=SegFormer · condition=snow · source-dataset=Cityscapes · target-training-data=full ACDCContrastive Model Adaptation for Cross-Condition Robustness in Semantic Segmentation
Source quote
L632: CMA │ 92.4 │ 70.5 │ 88.3 │ 50.4 │ 55.6 │ 56.3 │ 74.8 │ 71.1 │ 90.8 │ 29.4 │ 96.9 │ 77.4 │ 63.5 │ 90.1 │ 63.5 │ 79.6 │ 89.0 │ 45.6 │ 73.9 │ 71.5
2023BTSeg proposedmean IoU70.45split: test · semi-supervised-domain-adaptation · backbone=MiT-B5 · resolution=1080×1080 · domain-shift=Cityscapes→ACDCBTSeg: Barlow Twins Regularization for Domain Adaptation in Semantic Segmentation
Source quote
L279: BTSeg (Ours) │ 70.45 │ 92.9 │ 73.5 │ 88.3 │ 53.6 │ 47.2 │ 56.2 │ 67.9 │ 67.3 │ 86.9 │ 61.5 │ 95.3 │ 67.2 │ 46.8 │ 89.1 │ 73.1 │ 81.6 │ 83.1 │ 49.5 │ 57.5
2023CMRformer (CINE sax) (8) proposedAUC0.95split: test · input=CINE sax · split_size=100-train/50-testMultimodal Representation Learning of Cardiovascular Magnetic Resonance Imaging
Source quote
L327: Ours (CINE\textsubscript{sax}) (8) │ 0.70 │ 0.95 │ 0.70
2023CISS proposedmIoU69.6%split: test · unsupervised-domain-adaptation · condition=snow · target-training-data=entire ACDC training setCondition-Invariant Semantic Segmentation
Source quote
L316: CISS (ours) │ 84.1 │ 51.1 │ 91.0 │ 58.6 │ 50.5 │ 58.0 │ 77.5 │ 70.4 │ 91.3 │ 4.7 │ 96.7 │ 78.8 │ 60.3 │ 91.6 │ 71.0 │ 79.1 │ 87.0 │ 51.0 │ 70.5 │ 69.6
2023OVeNet proposedmIoU73.0split: testOVeNet: Offset Vector Network for Semantic Segmentation
Source quote
L241: OVeNet │ 95.8 │ 82.1 │ 91.3 │ 55.8 │ 54.6 │ 67.6 │ 80.5 │ 77.3 │ 89.7 │ 69.5 │ 96.8 │ 73.4 │ 39.1 │ 89.5 │ 61.9 │ 65.0 │ 89.4 │ 47.2 │ 60.6 │ 73.0
2023Ours (DG-T), text-prompt prompt randomization proposedmIoU61.2split: test · domain-generalization · source-domain=Cityscapes · target-domain=ACDCPrompting diffusion representations for cross-domain semantic segmentation
Source quote
L287: \multirow{2}{*}{DG} │ Ours (DG-T) │ 89.6 │ 62.5 │ 84.4 │ 48.6 │ 39.9 │ 49.2 │ 48.7 │ 55.6 │ 74.5 │ 48.3 │ 86.1 │ 60.3 │ 39.9 │ 84.9 │ 62.6 │ 63.5 │ 73.6 │ 37.7 │ 52.3 │ 61.2
2023VAFA-FR (frequency-consistency adversarial training) proposed non-standard sliceDSC73.05split: test · q_max=10 · backbone=UNETR · patch_size=32×32×32 · resolution=32x32 · evaluation_attack=VAFAFrequency Domain Adversarial Training for Robust Volumetric Medical Segmentation
Source quote
L244: \multirow{-2}{*}{\rotatebox[origin=c]{90}{\parbox[c]{0.8cm}{\texttt{ACDC}}}} │ \mathcal{M}^{\Scale[0.5]{\text{VAFA-FR}}}_{_{\text{\faShield*}}} │ 83.44 │ 60.63 │ 69.33 │ 60.61 │ 73.05 │ 91.36 │ 85.42 │ 87.42 │ 83.90 │ 91.23
2023CLMR (U-Net) proposedDI (Dice Index), Ave.0.8937split: test · backbone=U-NetSelecting the Best Optimizers for Deep Learning based Medical Image Segmentation
Source quote
L224: \multicolumn{1}{|l|}{U-Net} │ 0.8813 │ 0.6708 │ 0.8714 │ 0.8937
2023CLMR (DenseNet_2) proposedDI (Dice Index), Ave.0.9176split: test · backbone=DenseNet_2Selecting the Best Optimizers for Deep Learning based Medical Image Segmentation
Source quote
L226: \multicolumn{1}{|l|}{DenseNet\_2} │ 0.8924 │ 0.7626 │ 0.9064 │ 0.9176
2023HGFormer (Swin-L) proposedAll67.2split: test · domain-generalization · runs=3 · backbone=Swin-L · training-data=CityscapesHGFormer: Hierarchical Grouping Transformer for Domain Generalized Semantic Segmentation
Source quote
L191: HGFormer (ours) │ Swin-L │ 69.9 │ 52.7 │ 72.0 │ 68.6 │ 67.2
2022SADM proposedSSIM ↑0.851split: test · resolution=12×128×128×32SADM: Sequence-Aware Diffusion Model for Longitudinal Medical Image Generation
Source quote
L246: Ours │ 0.851 │ 28.992 │ 0.153 │ 0.978 │ 31.699 │ 0.090
2022SADM proposedPSNR ↑28.992split: test · resolution=12×128×128×32SADM: Sequence-Aware Diffusion Model for Longitudinal Medical Image Generation
Source quote
L246: Ours │ 0.851 │ 28.992 │ 0.153 │ 0.978 │ 31.699 │ 0.090
2022SADM proposedNRMSE ↓0.153split: test · resolution=12×128×128×32SADM: Sequence-Aware Diffusion Model for Longitudinal Medical Image Generation
Source quote
L246: Ours │ 0.851 │ 28.992 │ 0.153 │ 0.978 │ 31.699 │ 0.090
2022RoS-FL w/ DWCS proposedDSC0.8799split: test · clients=4 · local-epochs=1 · communication-rounds=300Robust Split Federated Learning for U-shaped Medical Image Networks
Source quote
L220: RoS-FL w/ DWCS │ 0.8799 │ 2.718 │ 0.8572 │ 0.7932
2022C-CAM proposedDSC80.34%split: test · weakly-supervised · supervision=image-levelC-CAM: Causal CAM for Weakly Supervised Semantic Segmentation on Medical Image
Source quote
L20: Recently, many excellent weakly supervised semantic segmentation (WSSS) works are proposed based on class activation mapping (CAM). However, there are few works that consider the characteristics of medical images. In this paper, we find that there are mainly two challenges of medical images in WSSS: i) the boundary of object foreground and background is not clear; ii) the co-occurrence phenomenon is very severe in training stage. We thus propose a Causal CAM (C-CAM) method to overcome the above challenges. Our method is motivated by two cause-effect chains including category-causality chain and anatomycausality chain. The category-causality chain represents the image content (cause) affects the category (effect). The anatomy-causality chain represents the anatomical structure (cause) affects the organ segmentation (effect). Extensive experiments were conducted on three public medical image data sets. Our C-CAM generates the best pseudo masks with the DSC of 77.26%, 80.34% and 78.15% on
2022BATFormer proposedAverage Dice92.84%split: test · training=2D slice-level · evaluation-unit=patient-levelBATFormer: Towards Boundary-Aware Lightweight Transformer for Efficient Medical Image Segmentation
Source quote
L5: Objective: Transformers, born to remedy the inadequate receptive fields of CNNs, have drawn explosive attention recently. However, the daunting computational complexity of global representation learning, together with rigid window partitioning, hinders their deployment in medical image segmentation. This work aims to address the above two issues in transformers for better medical image segmentation. Methods: We propose a boundary-aware lightweight transformer (BATFormer) that can build cross-scale global interaction with lower computational complexity and generate windows flexibly under the guidance of entropy. Specifically, to fully explore the benefits of transformers in long-range dependency establishment, a cross-scale global transformer (CGT) module is introduced to jointly utilize multiple small-scale feature maps for richer global features with lower computational complexity. Given the importance of shape modeling in medical image segmentation, a boundary-aware local transformer (BLT) module is constructed. Different from rigid window partitioning in vanilla transformers which would produce boundary distortion, BLT adopts an adaptive window partitioning scheme under the guidance of entropy for both computational complexity reduction and shape preservation. Results: BATFormer achieves the best performance in Dice of 92.84%, 91.97%, 90.26%, and 96.30% for the average, right ventricle, myocardium, and left ventricle respectively on the ACDC dataset and the best performance in Dice, IoU, and ACC of 90.76%, 84.64%, and 96.76% respectively on the ISIC 2018 dataset. More importantly, BATFormer requires the least amount of model parameters and the lowest computational complexity compared to the state-of-the-art approaches. Conclusion and Significance: Our results demonstrate the necessity of developing customized transformers for efficient and better medical image segmentation. We believe the design of BATFormer is inspiring and extendable to other applications/frameworks. The source code is publicly available at \url{https://github.com/xianlin7/BATFormer}.
2022FCT512 proposedAvg.93.13split: test · resolution=512×512 · training-data=100 challenge imagesThe Fully Convolutional Transformer for Medical Image Segmentation
Source quote
L426: 93.13
2022U-VPA (Ours(proposed)) proposed[email protected]18.5%split: test · online-continual-test-time-adaptation · backbone=Faster R-CNN · evaluation=mean across Fog, Night, Rain, and Snow · repetitions=10 · source-dataset=CityscapesCloud-Device Collaborative Adaptation to Continual Changing Environments in the Real-World
Source quote
L181: Ours(proposed) │ 21.1 │ 9.3 │ 15.7 │ 17.2 │ 24.7 │ 11.8 │ 17.8 │ 20.2 │ 26.3 │ 12.0 │ 18.5 │ 20.6 │ 26.1 │ 12.3 │ 18.0 │ 20.8 │ 18.5 │ +4.4
2022ScaleFormer proposedDSC90.17split: testScaleFormer: Revisiting the Transformer-based Backbones from a Scale-wise Perspective for Medical Image Segmentation
Source quote
L407: 90.17
2022ELSNet proposedDSC.Avg (class average)0.410split: test · 1-shot · runs=5 · training-exemplars=1Exemplar Learning for Medical Image Segmentation
Source quote
L300: 0.410 │ 0.293 │ 0.374 │ 0.563 │ 26.64 │ 47.63 │ 16.58 │ 15.73
2022ELSNet proposedHD95.Avg (class average)26.64split: test · 1-shot · runs=5 · training-exemplars=1Exemplar Learning for Medical Image Segmentation
Source quote
L300: 0.410 │ 0.293 │ 0.374 │ 0.563 │ 26.64 │ 47.63 │ 16.58 │ 15.73
2021Ours (KL+Ent) proposedDSC86.94split: test · subset=Set-3 · supervision=3 fully labeled images plus 5× as many partially labeled imagesSegmentation with mixed supervision: Confidence maximization helps knowledge distillation
Source quote
L225: Ours (KL+Ent)* │ \bf \extension{86.94} │ \bf \extension{8.84}
2021Ours (KL+Ent) proposedHD-958.84split: test · subset=Set-3 · supervision=3 fully labeled images plus 5× as many partially labeled imagesSegmentation with mixed supervision: Confidence maximization helps knowledge distillation
Source quote
L225: Ours (KL+Ent)* │ \bf \extension{86.94} │ \bf \extension{8.84}
2021nnFormer proposedAverage DSC92.06%split: test · repeats=10 · data-split=70 train / 10 validation / 20 testnnFormer: Volumetric Medical Image Segmentation via a 3D Transformer
Source quote
L225: nnFormer │ 92.06 │ 90.94 │ 89.58 │ 95.65
2021Adversarial TTT; no continual adaptation proposed non-standard sliceDice (↑)75.0split: testRe-using Adversarial Mask Discriminators for Test-time Training under Distribution Shifts
Source quote
L339: \checkmark │ \ding{55} │ 75.0\textsubscript{09} │ 67.1\textsubscript{10} │ 6.9\textsubscript{05}
2021Adversarial TTT with continual adaptation proposed non-standard sliceDice (↑)75.1split: testRe-using Adversarial Mask Discriminators for Test-time Training under Distribution Shifts
Source quote
L340: \hcell{\checkmark} │ \hcell{\checkmark} │ \hcell{\textbf{75.1\textsubscript{09}}} │ \hcell{\textbf{67.2\textsubscript{09}}} │ \hcell{\textbf{6.9\textsubscript{05}}}
2020Adv Bias (proposed) proposedAverage Dice score0.686split: test · semi-supervised · labeled-subjects=1Realistic Adversarial Data Augmentation for MR Image Segmentation
Source quote
L125: In the supervised learning setting (no access to unlabelled images), when only one or three labelled subject was available, the proposed method clearly outperformed all baseline methods. For semi-supervised learning, the proposed methods outperformed VAT, especially when only one labelled subject is available (0.686 vs 0.625). The proposed method achieves competitive results compared to the semi-supervised GAN-based method (cGANs) as well. Of note, cGANs adopts two additional GANs to sample geometric transformations and intensity transformations from unlabelled images. This is why it was only compared in the semi-supervised learning setting here. On the contrary, our approach is applicable to both low-shot supervised learning and semi-supervised learning. In addition, cGANs contains more parameters than our method and thus it might be less computationally efficient.
2020G^D encoder + random-initialized decoder proposedMean Dice score (DSC)0.784split: test · fine-tuned · decoder=random-initialized · labeled-volumes=2Contrastive learning of global and local features for medical image segmentation with limited annotations
Source quote
L494: {G (D)} │ {random init} │ ACDC │ \multicolumn{3}{|l|}{0.691} │ \multicolumn{3}{|l|}{0.784} │ \multicolumn{3}{|l|}{0.870}
2020Ours (KL+Ent), bottom branch proposedDSC75.92split: test · branch=bottom · subset=Set-3 · supervision=full and partialTeach Me to Segment with Mixed Supervision: Confident Students Become Masters
Source quote
L111: Ours (KL+Ent) │ \checkmark │ \checkmark │ 69.25 │ 49.93 │ \bf 75.92 │ \bf 30.12
2020Ours (KL+Ent), bottom branch proposedDSC78.77split: test · branch=bottom · subset=Set-5 · supervision=full and partialTeach Me to Segment with Mixed Supervision: Confident Students Become Masters
Source quote
L118: Ours (KL+Ent) │ \checkmark │ \checkmark │ 67.10 │ 45.28 │ \bf 78.77 │ \bf 23.29
2020Ours (KL+Ent), bottom branch proposedDSC88.07split: test · branch=bottom · subset=Set-10 · supervision=full and partialTeach Me to Segment with Mixed Supervision: Confident Students Become Masters
Source quote
L125: Ours (KL+Ent) │ \checkmark │ \checkmark │ 83.96 │ 30.71 │ \bf 88.07 │ \bf 4.37
2020Res U-net+bi-ConvLSTM (our framework) proposedMYO-Dice0.7260split: test · phase=EDMyocardial Segmentation of Cardiac MRI Sequences With Temporal Consistency for Coronary Artery Disease Diagnosis
Source quote
L220: our framework │ 0.8967 │ 0.8146 │ 0.7260 │ 0.5587 │ 0.8133 │ 0.7080 │ 0.7656 │ 0.4231
2020Res U-net+bi-ConvLSTM (our framework) proposedMYO-Dice0.7656split: test · phase=ESMyocardial Segmentation of Cardiac MRI Sequences With Temporal Consistency for Coronary Artery Disease Diagnosis
Source quote
L220: our framework │ 0.8967 │ 0.8146 │ 0.7260 │ 0.5587 │ 0.8133 │ 0.7080 │ 0.7656 │ 0.4231
2018Base + CRF-RNN (scribble-supervised) proposedMean Dice0.880split: test · scribble-supervised · training-dimension=2D slicesLearning to Segment Medical Images with Scribble-Supervision Alone
Source quote
L121: Base + CRF-RNN │ 0.915 │ 0.885 │ 0.840 │ 0.880 │ 0.698 │ 0.863 │ 0.781
20172D/3D UNet ensemble proposedDice score, LVC0.950split: test · method=2D/3D UNet ensemble · structure=LVCAutomatic Cardiac Disease Assessment on cine-MRI via Time-Series Segmentation and Domain Specific Features
Source quote
L12: 0.908 (RVC) and 0.905 (LVM) in a cross-validation over the training set (100 cases) and 0.950 (LVC), 0.923 (RVC) and 0.911 (LVM) on the test set (50 cases). We report a classification accuracy of 94% on a training set cross-validation and 92% on the test set. Our results underpin the potential of machine learning methods for accurate, fast and reproducible segmentation and computer-assisted diagnosis (CAD).
20172D/3D UNet ensemble proposedDice score, RVC0.923split: test · method=2D/3D UNet ensemble · structure=RVCAutomatic Cardiac Disease Assessment on cine-MRI via Time-Series Segmentation and Domain Specific Features
Source quote
L12: 0.908 (RVC) and 0.905 (LVM) in a cross-validation over the training set (100 cases) and 0.950 (LVC), 0.923 (RVC) and 0.911 (LVM) on the test set (50 cases). We report a classification accuracy of 94% on a training set cross-validation and 92% on the test set. Our results underpin the potential of machine learning methods for accurate, fast and reproducible segmentation and computer-assisted diagnosis (CAD).
20172D/3D UNet ensemble proposedDice score, LVM0.911split: test · method=2D/3D UNet ensemble · structure=LVMAutomatic Cardiac Disease Assessment on cine-MRI via Time-Series Segmentation and Domain Specific Features
Source quote
L12: 0.908 (RVC) and 0.905 (LVM) in a cross-validation over the training set (100 cases) and 0.950 (LVC), 0.923 (RVC) and 0.911 (LVM) on the test set (50 cases). We report a classification accuracy of 94% on a training set cross-validation and 92% on the test set. Our results underpin the potential of machine learning methods for accurate, fast and reproducible segmentation and computer-assisted diagnosis (CAD).
2017MLP and random forest classification ensemble proposedClassification accuracy92%split: test · method=MLP and random forest classification ensembleAutomatic Cardiac Disease Assessment on cine-MRI via Time-Series Segmentation and Domain Specific Features
Source quote
L167: ACDC training data using the features described in section 2.3. In a five fold cross-validation, a classification accuracy of 94% was achieved. The individual performance of the MLP ensemble and random forest were 93% and 92%, respectively. The test set accuracy was 92%. Confusion matrices are provided in