ACDC
242 papers · 564 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching regime=semi-supervised.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | TransMedSeg SOTA frontier | 89.96% | 2025-05-01 | labeled-data=10% · 7 labeled scans (10%) and 63 unlabeled scans (90%). | TransMedSeg: A Transferable Semantic Framework for Semi-Supervised Medical Image SegmentationSource quoteTransMedSeg │ 88.14 │ 79.48 │ 3.42 │ 0.97 │ 89.96 │ 82.31 │ 1.61 │ 0.64 |
| 2 | ACTION SOTA frontier (+2 variants) | 89.8% | 2022-06-01 | labeled-cases=7 · anatomical-category=RV · 7-labeled-case setting; RV category | Bootstrapping Semi-supervised Medical Image Segmentation with Anatomical-Aware Contrastive DistillationSource quoteTable \ref{table:acdc_main} shows the evaluation results on ACDC dataset under two unlabeled settings (3 or 7 labeled cases). ACTION can substantially improve results on two unlabeled settings, greatly outperforming the previous state-of-the-art SSL methods. Specifically, our ACTION, trained on 3 labeled cases, dramatically improves the previous best averaged Dice score from 73.6% to 87.5% by a large margin, and even matches previous SSL methods using 7 labeled cases. When using 7 labeled cases, ACTION further pushes the state-of-the-art results to 89.7% in Dice. We observe that the gains are more pronounced on the two categories(i.e., RV and Myo), and our ACTION achieves 89.8% and 86.7% in terms of Dice, performing competitive or even better than the supervised baseline (89.2% and 86.7%). As shown in Figure \ref{fig:vis_acdc}, we can see the clear advantage of ACTION, where the boundaries of different regions are clearly sharper and more accurate such as RV and Myo regions. Table \ref{table:lits_main} also shows the evaluation results on LiTS dataset under two unlabeled settings (5% or 10% labeled cases). On both two labeled settings, ACTION significantly outperforms all the state-of-the-art methods by a significant margin. As shown in Figure \ref{fig:vis_lits}, ACTION achieves consistently sharp and accurate object boundaries compared to other SSL methods. |
| 3 | MC-Net+ SOTA frontier (+1 variant) | 88.51% | 2022-01-01 | labeled-data=20% · unlabeled-data=80% · 20% labeled and 80% unlabeled scans; average over myocardium, left ventricle, and rig… | Mutual consistency learning for semi-supervised medical image segmentationSource quoteMC-Net+ (Ours) │ 88.51 │ 80.19 │ 5.35 │ 1.54 │ 1.81 │ 2.99 |
| 4 | DCPA | 85.86% | 2023-08-01 | labeled_scans=3 (5%) · dimensionality=2D · unlabeled_scans=67 (95%) · 2D segmentation; 3 labeled scans (5%) and 67 unlabeled scans (95%); Dice averaged acr… | Dual-Decoder Consistency via Pseudo-Labels Guided Data Augmentation for Semi-Supervised Medical Image SegmentationSource quoteOurs │ 85.86 │ 76.13 │ 5.83 │ 2.03 |
| 5 | AdvMIM | 85.4% | 2025-01-01 | labeled-data=3% · 3% labeled-data partition; semi-supervised medical image segmentation. | AdvMIM: Adversarial Masked Image Modeling for Semi-supervised Medical Image SegmentationSource quoteAdvMIM │ 85.4_{(10.1\textcolor{green}{\uparrow})} │ 2.0_{(8.7\textcolor{red}{\downarrow})} │ 89.0_{(0.6\textcolor{green}{\uparrow})} │ 1.3_{(3.1\textcolor{red}{\downarrow})} │ 66.3_{(1.0\textcolor{green}{\uparrow})} │ 22.7_{(9.9\textcolor{red}{\downarrow})} │ 74.8_{(3.4\textcolor{green}{\uparrow})} │ 15.5_{(15.7\textcolor{red}{\downarrow})} │ 79.8_{(1.9\textcolor{green}{\uparrow})} │ 22.2_{(9.9\textcolor{red}{\downarrow})} │ 81.8_{(0.7\textcolor{green}{\uparrow})} │ 19.5_{(4.9\textcolor{red}{\downarrow})} |
| 6 | Cross-ALD | 80.6% | 2023-10-01 | backbone=U-Net · labeled-data=5% · Semi-supervised segmentation with 5% labeled data (3 labeled scans and 67 unlabeled s… | Cross-adversarial local distribution regularization for semi-supervised medical image segmentationSource quoteCross-ALD (Ours) │ 80.6 │ 69.08 │ 5.96 │ 1.9 │ 1.83 │ 2.99 |
| 7 | AugPaint (+1 variant) | 77.73% | 2025-06-01 | labeled-cases=5 · AugPaint-only row; 5 labeled cases. | Inpainting is All You Need: A Diffusion-based Augmentation Method for Semi-supervised Medical Image SegmentationSource quote\multirow{4}{*}{ACDC} │ AugPaint │ 42.42 │ 44.15 │ 77.73 |
Regimesemi-supervised (65)fine-tuned (21)weakly-supervised (11)domain-generalization (11)test-time-adaptation (10)scribble-supervised (8)
Showing 65 of 65 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | ICTC proposed | Dice | 88.22 | semi-supervised · labeled-cases=7 (10%) · unlabeled-cases=63 | An Intra- and Cross-frame Topological Consistency Scheme for Semi-supervised Atherosclerotic Coronary Plaque SegmentationSource quoteL182: ICTC(Ours) │ 7(10%) │ 63 │ 88.22 │ 78.72 │ 7.48 │ 1.58 |
| 2025 | ICTC proposed | Jaccard (Jac) | 78.72 | semi-supervised · labeled-cases=7 (10%) · unlabeled-cases=63 | An Intra- and Cross-frame Topological Consistency Scheme for Semi-supervised Atherosclerotic Coronary Plaque SegmentationSource quoteL182: ICTC(Ours) │ 7(10%) │ 63 │ 88.22 │ 78.72 │ 7.48 │ 1.58 |
| 2025 | TransMedSeg proposed | Dice | 89.96% | semi-supervised · labeled-data=10% | TransMedSeg: A Transferable Semantic Framework for Semi-Supervised Medical Image SegmentationSource quoteL168: TransMedSeg │ 88.14 │ 79.48 │ 3.42 │ 0.97 │ 89.96 │ 82.31 │ 1.61 │ 0.64 |
| 2025 | AugPaint proposed | Dice | 42.42% | semi-supervised · labeled-cases=1 | Inpainting is All You Need: A Diffusion-based Augmentation Method for Semi-supervised Medical Image SegmentationSource quoteL286: \multirow{4}{*}{ACDC} │ AugPaint │ 42.42 │ 44.15 │ 77.73 |
| 2025 | AugPaint proposed | Dice | 77.73% | semi-supervised · labeled-cases=5 | Inpainting is All You Need: A Diffusion-based Augmentation Method for Semi-supervised Medical Image SegmentationSource quoteL286: \multirow{4}{*}{ACDC} │ AugPaint │ 42.42 │ 44.15 │ 77.73 |
| 2025 | AdvMIM proposed | Dice | 85.4% | semi-supervised · labeled-data=3% | AdvMIM: Adversarial Masked Image Modeling for Semi-supervised Medical Image SegmentationSource quoteL134: AdvMIM │ 85.4_{(10.1\textcolor{green}{\uparrow})} │ 2.0_{(8.7\textcolor{red}{\downarrow})} │ 89.0_{(0.6\textcolor{green}{\uparrow})} │ 1.3_{(3.1\textcolor{red}{\downarrow})} │ 66.3_{(1.0\textcolor{green}{\uparrow})} │ 22.7_{(9.9\textcolor{red}{\downarrow})} │ 74.8_{(3.4\textcolor{green}{\uparrow})} │ 15.5_{(15.7\textcolor{red}{\downarrow})} │ 79.8_{(1.9\textcolor{green}{\uparrow})} │ 22.2_{(9.9\textcolor{red}{\downarrow})} │ 81.8_{(0.7\textcolor{green}{\uparrow})} │ 19.5_{(4.9\textcolor{red}{\downarrow})} |
| 2025 | Ours (switching Dual-Student framework with LA-EMA) proposed | Dice | 90.67 | semi-supervised · labeled-data=7/70 patients | Adaptive Knowledge Transferring with Switching Dual-Student Framework for Semi-Supervised Medical Image SegmentationSource quoteL429: 90.67 83.41 |
| 2025 | Ours (switching Dual-Student framework with LA-EMA) proposed | Jaccard | 83.41% | semi-supervised · labeled-data=7/70 patients | Adaptive Knowledge Transferring with Switching Dual-Student Framework for Semi-Supervised Medical Image SegmentationSource quoteL429: 90.67 83.41 |
| 2025 | Multi-Prototype-based Embedding Refinement proposed | Dice | 88.64 | semi-supervised · labeled-cases=3 (5%) · unlabeled-cases=67 (95%) | Multi-Prototype-based Embedding Refinement for Medical Image SegmentationSource quoteL168: Ours │ 88.64 │ 80.21 │ 1.51 │ 0.60 |
| 2025 | Multi-Prototype-based Embedding Refinement proposed | Dice | 89.69 | semi-supervised · labeled-cases=7 (10%) · unlabeled-cases=63 (90%) | Multi-Prototype-based Embedding Refinement for Medical Image SegmentationSource quoteL177: Ours │ 89.69 │ 81.88 │ 1.65 │ 0.56 |
| 2025 | BCP (Reproduced) + LA-EMA ablation | Dice | 89.84 | semi-supervised · method=reproduced BCP + LA-EMA · labeled-data=7/70 patients | Adaptive Knowledge Transferring with Switching Dual-Student Framework for Semi-Supervised Medical Image SegmentationSource quoteL473: 89.84 |
| 2025 | MCNet+ baseline | Dice | 87.10 | semi-supervised · labeled-cases=7 (10%) · unlabeled-cases=63 | An Intra- and Cross-frame Topological Consistency Scheme for Semi-supervised Atherosclerotic Coronary Plaque SegmentationSource quoteL180: MCNet+ \cite{MC} │ 7(10%) │ 63 │ 87.10 │ 78.06 │ 6.68 │ 2.00 |
| 2025 | MCNet+ baseline | Jaccard (Jac) | 78.06 | semi-supervised · labeled-cases=7 (10%) · unlabeled-cases=63 | An Intra- and Cross-frame Topological Consistency Scheme for Semi-supervised Atherosclerotic Coronary Plaque SegmentationSource quoteL180: MCNet+ \cite{MC} │ 7(10%) │ 63 │ 87.10 │ 78.06 │ 6.68 │ 2.00 |
| 2025 | M-CnT baseline | Dice | 75.3% | semi-supervised · labeled-data=3% | AdvMIM: Adversarial Masked Image Modeling for Semi-supervised Medical Image SegmentationSource quoteL132: M-CnT~\cite{huang2024combinatorial} │ 75.3 │ 10.7 │ 88.4 │ 4.4 │ 65.3 │ 32.6 │ 71.4 │ 31.2 │ 77.9 │ 32.1 │ 81.1 │ 24.4 |
| 2025 | BCP (Reproduced) baseline | Dice | 89.25 | semi-supervised · method=reproduced BCP · labeled-data=7/70 patients | Adaptive Knowledge Transferring with Switching Dual-Student Framework for Semi-Supervised Medical Image SegmentationSource quoteL470: 89.25 |
| 2025 | BCP baseline | Dice | 87.59 | semi-supervised · labeled-cases=3 (5%) · unlabeled-cases=67 (95%) | Multi-Prototype-based Embedding Refinement for Medical Image SegmentationSource quoteL167: BCP \cite{ref27} │ 87.59 │ 78.67 │ 1.90 │ 0.67 |
| 2025 | BCP baseline | Dice | 88.84 | semi-supervised · labeled-cases=7 (10%) · unlabeled-cases=63 (90%) | Multi-Prototype-based Embedding Refinement for Medical Image SegmentationSource quoteL176: BCP \cite{ref27} │ 88.84 │ 80.62 │ 3.98 │ 1.17 |
| 2024 | MemWarp proposed | Average Dice | 89.61% | split: test · semi-supervised · inference-masks=not-required | MemWarp: Discontinuity-Preserving Cardiac Registration with Memorized Anatomical FiltersSource quoteL185: MemWarp (ours) │ 89.61 │ 89.30 │ 86.49 │ 93.04 │ 3.93 │ 0.149 |
| 2024 | MemWarp proposed | HD95 | 3.93 mm | split: test · semi-supervised · inference-masks=not-required | MemWarp: Discontinuity-Preserving Cardiac Registration with Memorized Anatomical FiltersSource quoteL185: MemWarp (ours) │ 89.61 │ 89.30 │ 86.49 │ 93.04 │ 3.93 │ 0.149 |
| 2024 | SemSim proposed | DSC | 0.872 | split: test · semi-supervised · labeled-data=1% (1 case) | SemSim: Revisiting Weak-to-Strong Consistency from a Semantic Similarity Perspective for Semi-supervised Medical Image SegmentationSource quoteL361: SemSim │ {\color[HTML]{FF0000}0.872} │ {\color[HTML]{FF0000}1.8} │ {\color[HTML]{FF0000}0.888} │ {\color[HTML]{FF0000}1.9} │ {\color[HTML]{FF0000}0.896} │ {\color[HTML]{FF0000}2.3} │ 2.60 |
| 2024 | SemSim proposed | 95HD | 1.8 mm | split: test · semi-supervised · labeled-data=1% (1 case) | SemSim: Revisiting Weak-to-Strong Consistency from a Semantic Similarity Perspective for Semi-supervised Medical Image SegmentationSource quoteL361: SemSim │ {\color[HTML]{FF0000}0.872} │ {\color[HTML]{FF0000}1.8} │ {\color[HTML]{FF0000}0.888} │ {\color[HTML]{FF0000}1.9} │ {\color[HTML]{FF0000}0.896} │ {\color[HTML]{FF0000}2.3} │ 2.60 |
| 2024 | CPC-SAM proposed | DSC | 85.56% | semi-supervised · labeled-data=1/70 | Cross Prompting Consistency with Segment Anything Model for Semi-supervised Medical Image SegmentationSource quoteL153: CPC-SAM (ours) │ {10/431} │ {71.20} │ {61.15} │ {100.22} │ 37.86 │ {1/70} │ {85.56} │ {75.74} │ {9.19} │ 2.84 |
| 2024 | Ours-ABD (BCP) proposed | DSC↑ | 89.81 | split: test · semi-supervised | Adaptive Bidirectional Displacement for Semi-Supervised Medical Image SegmentationSource quoteL505: 89.81 |
| 2024 | Ours-ABD (BCP) proposed | 95HD↓ | 1.46 | split: test · semi-supervised | Adaptive Bidirectional Displacement for Semi-Supervised Medical Image SegmentationSource quoteL507: 1.46 |
| 2024 | Ours-ABD (BCP) proposed | ASD↓ | 0.49 | split: test · semi-supervised | Adaptive Bidirectional Displacement for Semi-Supervised Medical Image SegmentationSource quoteL508: 0.49 |
| 2024 | M-CnT proposed | DSC | 0.753 | split: test · semi-supervised · labeled-data=3% | Combinatorial CNN-Transformer Learning with Manifold Constraints for Semi-supervised Medical Image SegmentationSource quoteL318: 0.753 |
| 2024 | Slicer Network baseline | Average Dice | 83.68% | split: test · semi-supervised | MemWarp: Discontinuity-Preserving Cardiac Registration with Memorized Anatomical FiltersSource quoteL184: Slicer Network \cite{zhang2024slicer} │ 83.68 │ 84.94 │ 77.97 │ 88.12 │ 6.10 │ 0.099 |
| 2024 | UniMatch baseline | DSC | 84.47% | semi-supervised · labeled-data=1/70 | Cross Prompting Consistency with Segment Anything Model for Semi-supervised Medical Image SegmentationSource quoteL151: UniMatch(CVPR’23)~\cite{yang2023revisiting} │ {10/431} │ {60.98} │ {49.85} │ {109.79} │ 47.50 │ {1/70} │ {84.47} │ {74.25} │ {15.36} │ 4.57 |
| 2024 | BCP (CVPR’2023) baseline | DSC↑ | 88.84 | split: test · semi-supervised | Adaptive Bidirectional Displacement for Semi-Supervised Medical Image SegmentationSource quoteL495: 88.84 |
| 2024 | BCP (CVPR’2023) baseline | 95HD↓ | 3.98 | split: test · semi-supervised | Adaptive Bidirectional Displacement for Semi-Supervised Medical Image SegmentationSource quoteL497: 3.98 |
| 2024 | BCP (CVPR’2023) baseline | ASD↓ | 1.17 | split: test · semi-supervised | Adaptive Bidirectional Displacement for Semi-Supervised Medical Image SegmentationSource quoteL498: 1.17 |
| 2024 | DiffRect baseline | DICE↑ | 90.18 | semi-supervised · labeled-cases=7 · labeled-fraction=10% | Mind the Context: Attention-Guided Weak-to-Strong Consistency for Enhanced Semi-Supervised Medical Image SegmentationSource quoteL186: DiffRect~\cite{liu2024diffrect} │ MICCAI’24 │ 82.40 │ 71.96 │ 10.04 │ 2.90 │ 86.95 │ 78.08 │ 4.07 │ 1.23 │ 90.18 │ 82.12 │ 1.38 │ 0.48 |
| 2024 | BCP baseline | DICE↑ | 88.84 | semi-supervised · labeled-cases=7 · labeled-fraction=10% | Mind the Context: Attention-Guided Weak-to-Strong Consistency for Enhanced Semi-Supervised Medical Image SegmentationSource quoteL173: BCP~\cite{bai2023bidirectional} │ CVPR’23 │ -- │ -- │ -- │ -- │ 87.59 │ 78.67 │ 1.90 │ 0.67 │ 88.84 │ 80.62 │ 3.98 │ 1.17 |
| 2024 | DiffRect baseline | DICE↑ | 86.95 | semi-supervised · labeled-cases=3 · labeled-fraction=5% | Mind the Context: Attention-Guided Weak-to-Strong Consistency for Enhanced Semi-Supervised Medical Image SegmentationSource quoteL186: DiffRect~\cite{liu2024diffrect} │ MICCAI’24 │ 82.40 │ 71.96 │ 10.04 │ 2.90 │ 86.95 │ 78.08 │ 4.07 │ 1.23 │ 90.18 │ 82.12 │ 1.38 │ 0.48 |
| 2023 | DCPA proposed | Dice | 85.86% | semi-supervised · labeled_scans=3 (5%) · dimensionality=2D · unlabeled_scans=67 (95%) | Dual-Decoder Consistency via Pseudo-Labels Guided Data Augmentation for Semi-Supervised Medical Image SegmentationSource quoteL288: Ours │ 85.86 │ 76.13 │ 5.83 │ 2.03 |
| 2023 | BCP (α=0.5) proposed | Dice | 87.59 | semi-supervised · alpha=0.5 · input=2D slices · classes=four-class average · labeled-data=5% (3 scans) · unlabeled-data=95% (67 scans) | Bidirectional Copy-Paste for Semi-Supervised Medical Image SegmentationSource quoteL342: 88.02 │ 78.72 │ 7.90 │ 2.15 │ \multirow{4}{*}{3(5%)} │ \multicolumn{1}{c|}{\multirow{4}{*}{67(95%)}} │ 87.59 │ 78.67 │ 1.90 │ 0.67 |
| 2023 | Cross-ALD proposed | Dice (%) | 80.6% | semi-supervised · backbone=U-Net · labeled-data=5% | Cross-adversarial local distribution regularization for semi-supervised medical image segmentationSource quoteL142: Cross-ALD (Ours) │ 80.6 │ 69.08 │ 5.96 │ 1.9 │ 1.83 │ 2.99 |
| 2023 | ARCO-SAG proposed | averaged Dice | 84.9% | semi-supervised · labeled-data=1% | Rethinking Semi-Supervised Medical Image Segmentation: A Variance-Reduction PerspectiveSource quoteL187: Our \texttt{ARCO-SAG}\xspace achieves \{84.9%, 87.1%, 88.5%\}, \{64.1%, 67.3%, 69.4%\}, \{86.1%, 88.6%, 89.3%\}, \{91.5%, 92.5%, 92.6%\}, \{73.2%, 86.9%, 89.1%\} in averaged Dice across ACDC, LiTS, MMWHS, MP-MRI, and LA. |
| 2023 | MCSC (Multi-Scale Cross Supervised Contrastive Learning) proposed | DSC | 89.4% | semi-supervised · labeled-cases=7 · labeled-fraction=10% | Multi-Scale Cross Contrastive Learning for Semi-Supervised Medical Image SegmentationSource quoteL165: More importantly, it achieves 2.3mm HD, significantly better than even the fully supervised U-Net and BATFormer, which achieve 4.0 and 8.0 respectively. It also demonstrates competitive DSC of 89.4 %, compared with 91.7 % and 92.8 % of U-Net and BATFormer. |
| 2023 | MCSC (Multi-Scale Cross Supervised Contrastive Learning) proposed | HD | 2.3 mm | semi-supervised · labeled-cases=7 · labeled-fraction=10% | Multi-Scale Cross Contrastive Learning for Semi-Supervised Medical Image SegmentationSource quoteL165: More importantly, it achieves 2.3mm HD, significantly better than even the fully supervised U-Net and BATFormer, which achieve 4.0 and 8.0 respectively. It also demonstrates competitive DSC of 89.4 %, compared with 91.7 % and 92.8 % of U-Net and BATFormer. |
| 2023 | MCSC (Multi-Scale Cross Supervised Contrastive Learning) proposed | DSC | 73.6% | semi-supervised · labeled-cases=3 · labeled-fraction=5% | Multi-Scale Cross Contrastive Learning for Semi-Supervised Medical Image SegmentationSource quoteL191: MCSC (Ours) │ {\bf 73.6 } │ {\bf 10.5 } │ {\bf70.0} │ {\bf8.8} │ {\bf 79.2} │ {\bf14.9} │ {\bf71.7} │ {\bf7.8} |
| 2023 | SCP-Net proposed | DSC | 89.69 | semi-supervised · labeled-scans=14 · unlabeled-scans=126 | Self-aware and Cross-sample Prototypical Learning for Semi-supervised Medical Image SegmentationSource quoteL209: SCP-Net │ 14 │ 126 │ 89.26 │ 0.77 │ 87.11 │ 0.51 │ 92.70 │ 0.92 │ 89.69 │ 0.73 |
| 2023 | SCP-Net proposed | ASSD | 0.73 | semi-supervised · labeled-scans=14 · unlabeled-scans=126 | Self-aware and Cross-sample Prototypical Learning for Semi-supervised Medical Image SegmentationSource quoteL209: SCP-Net │ 14 │ 126 │ 89.26 │ 0.77 │ 87.11 │ 0.51 │ 92.70 │ 0.92 │ 89.69 │ 0.73 |
| 2023 | SS-Net baseline | Dice score (%) | 65.82% | semi-supervised · dimension=2D · labeled-cases=3 · labeled-fraction=5% | Rethinking Data Perturbation and Model Stabilization for Semi-supervised Medical Image SegmentationSource quoteL272: SS-Net \cite{wu2022exploring} │ 65.82 │ 55.38 │ 6.67 │ 2.28 │ 1.83 │ 2.99 |
| 2023 | SS-Net baseline | Dice | 65.82% | semi-supervised · labeled_scans=3 (5%) · dimensionality=2D · unlabeled_scans=67 (95%) | Dual-Decoder Consistency via Pseudo-Labels Guided Data Augmentation for Semi-Supervised Medical Image SegmentationSource quoteL286: SS-Net (MICCAI'22) │ 65.82 │ 55.38 │ 6.67 │ 2.28 |
| 2023 | SS-Net baseline | Dice (%) | 65.82% | semi-supervised · backbone=U-Net · labeled-data=5% | Cross-adversarial local distribution regularization for semi-supervised medical image segmentationSource quoteL141: SS-Net \cite{wu2022exploring} │ 65.82 │ 55.38 │ 6.67 │ 2.28 │ 1.83 │ 2.99 |
| 2022 | ACTION proposed | averaged Dice | 87.5% | semi-supervised · labeled-cases=3 | Bootstrapping Semi-supervised Medical Image Segmentation with Anatomical-Aware Contrastive DistillationSource quoteL384: Table \ref{table:acdc_main} shows the evaluation results on ACDC dataset under two unlabeled settings (3 or 7 labeled cases). ACTION can substantially improve results on two unlabeled settings, greatly outperforming the previous state-of-the-art SSL methods. Specifically, our ACTION, trained on 3 labeled cases, dramatically improves the previous best averaged Dice score from 73.6% to 87.5% by a large margin, and even matches previous SSL methods using 7 labeled cases. When using 7 labeled cases, ACTION further pushes the state-of-the-art results to 89.7% in Dice. We observe that the gains are more pronounced on the two categories(i.e., RV and Myo), and our ACTION achieves 89.8% and 86.7% in terms of Dice, performing competitive or even better than the supervised baseline (89.2% and 86.7%). As shown in Figure \ref{fig:vis_acdc}, we can see the clear advantage of ACTION, where the boundaries of different regions are clearly sharper and more accurate such as RV and Myo regions. Table \ref{table:lits_main} also shows the evaluation results on LiTS dataset under two unlabeled settings (5% or 10% labeled cases). On both two labeled settings, ACTION significantly outperforms all the state-of-the-art methods by a significant margin. As shown in Figure \ref{fig:vis_lits}, ACTION achieves consistently sharp and accurate object boundaries compared to other SSL methods. |
| 2022 | ACTION proposed | Dice | 89.7% | semi-supervised · labeled-cases=7 | Bootstrapping Semi-supervised Medical Image Segmentation with Anatomical-Aware Contrastive DistillationSource quoteL384: Table \ref{table:acdc_main} shows the evaluation results on ACDC dataset under two unlabeled settings (3 or 7 labeled cases). ACTION can substantially improve results on two unlabeled settings, greatly outperforming the previous state-of-the-art SSL methods. Specifically, our ACTION, trained on 3 labeled cases, dramatically improves the previous best averaged Dice score from 73.6% to 87.5% by a large margin, and even matches previous SSL methods using 7 labeled cases. When using 7 labeled cases, ACTION further pushes the state-of-the-art results to 89.7% in Dice. We observe that the gains are more pronounced on the two categories(i.e., RV and Myo), and our ACTION achieves 89.8% and 86.7% in terms of Dice, performing competitive or even better than the supervised baseline (89.2% and 86.7%). As shown in Figure \ref{fig:vis_acdc}, we can see the clear advantage of ACTION, where the boundaries of different regions are clearly sharper and more accurate such as RV and Myo regions. Table \ref{table:lits_main} also shows the evaluation results on LiTS dataset under two unlabeled settings (5% or 10% labeled cases). On both two labeled settings, ACTION significantly outperforms all the state-of-the-art methods by a significant margin. As shown in Figure \ref{fig:vis_lits}, ACTION achieves consistently sharp and accurate object boundaries compared to other SSL methods. |
| 2022 | ACTION proposed | Dice | 89.8% | semi-supervised · labeled-cases=7 · anatomical-category=RV | Bootstrapping Semi-supervised Medical Image Segmentation with Anatomical-Aware Contrastive DistillationSource quoteL384: Table \ref{table:acdc_main} shows the evaluation results on ACDC dataset under two unlabeled settings (3 or 7 labeled cases). ACTION can substantially improve results on two unlabeled settings, greatly outperforming the previous state-of-the-art SSL methods. Specifically, our ACTION, trained on 3 labeled cases, dramatically improves the previous best averaged Dice score from 73.6% to 87.5% by a large margin, and even matches previous SSL methods using 7 labeled cases. When using 7 labeled cases, ACTION further pushes the state-of-the-art results to 89.7% in Dice. We observe that the gains are more pronounced on the two categories(i.e., RV and Myo), and our ACTION achieves 89.8% and 86.7% in terms of Dice, performing competitive or even better than the supervised baseline (89.2% and 86.7%). As shown in Figure \ref{fig:vis_acdc}, we can see the clear advantage of ACTION, where the boundaries of different regions are clearly sharper and more accurate such as RV and Myo regions. Table \ref{table:lits_main} also shows the evaluation results on LiTS dataset under two unlabeled settings (5% or 10% labeled cases). On both two labeled settings, ACTION significantly outperforms all the state-of-the-art methods by a significant margin. As shown in Figure \ref{fig:vis_lits}, ACTION achieves consistently sharp and accurate object boundaries compared to other SSL methods. |
| 2022 | ACTION proposed | Dice | 86.7% | semi-supervised · labeled-cases=7 · anatomical-category=Myo | Bootstrapping Semi-supervised Medical Image Segmentation with Anatomical-Aware Contrastive DistillationSource quoteL384: Table \ref{table:acdc_main} shows the evaluation results on ACDC dataset under two unlabeled settings (3 or 7 labeled cases). ACTION can substantially improve results on two unlabeled settings, greatly outperforming the previous state-of-the-art SSL methods. Specifically, our ACTION, trained on 3 labeled cases, dramatically improves the previous best averaged Dice score from 73.6% to 87.5% by a large margin, and even matches previous SSL methods using 7 labeled cases. When using 7 labeled cases, ACTION further pushes the state-of-the-art results to 89.7% in Dice. We observe that the gains are more pronounced on the two categories(i.e., RV and Myo), and our ACTION achieves 89.8% and 86.7% in terms of Dice, performing competitive or even better than the supervised baseline (89.2% and 86.7%). As shown in Figure \ref{fig:vis_acdc}, we can see the clear advantage of ACTION, where the boundaries of different regions are clearly sharper and more accurate such as RV and Myo regions. Table \ref{table:lits_main} also shows the evaluation results on LiTS dataset under two unlabeled settings (5% or 10% labeled cases). On both two labeled settings, ACTION significantly outperforms all the state-of-the-art methods by a significant margin. As shown in Figure \ref{fig:vis_lits}, ACTION achieves consistently sharp and accurate object boundaries compared to other SSL methods. |
| 2022 | Proposed method (RCS + DTS + fuzzy fusion) proposed | Average DSC | 0.889 | semi-supervised · labeled-data=10% | Addressing Class Imbalance in Semi-supervised Image Segmentation: A Study on Cardiac MRISource quoteL148: 0.889 |
| 2022 | Previous best method (unnamed) baseline | averaged Dice | 73.6% | semi-supervised · labeled-cases=3 | Bootstrapping Semi-supervised Medical Image Segmentation with Anatomical-Aware Contrastive DistillationSource quoteL384: Table \ref{table:acdc_main} shows the evaluation results on ACDC dataset under two unlabeled settings (3 or 7 labeled cases). ACTION can substantially improve results on two unlabeled settings, greatly outperforming the previous state-of-the-art SSL methods. Specifically, our ACTION, trained on 3 labeled cases, dramatically improves the previous best averaged Dice score from 73.6% to 87.5% by a large margin, and even matches previous SSL methods using 7 labeled cases. When using 7 labeled cases, ACTION further pushes the state-of-the-art results to 89.7% in Dice. We observe that the gains are more pronounced on the two categories(i.e., RV and Myo), and our ACTION achieves 89.8% and 86.7% in terms of Dice, performing competitive or even better than the supervised baseline (89.2% and 86.7%). As shown in Figure \ref{fig:vis_acdc}, we can see the clear advantage of ACTION, where the boundaries of different regions are clearly sharper and more accurate such as RV and Myo regions. Table \ref{table:lits_main} also shows the evaluation results on LiTS dataset under two unlabeled settings (5% or 10% labeled cases). On both two labeled settings, ACTION significantly outperforms all the state-of-the-art methods by a significant margin. As shown in Figure \ref{fig:vis_lits}, ACTION achieves consistently sharp and accurate object boundaries compared to other SSL methods. |
| 2022 | Global + Local CL baseline | Average DSC | 0.886 | semi-supervised · labeled-data=10% | Addressing Class Imbalance in Semi-supervised Image Segmentation: A Study on Cardiac MRISource quoteL141: \multicolumn{1}{c|}{0.886} |
| 2021 | Bootstrap representation learning (Ours; slice prediction with foreground-background calibration) proposed | DSC | 0.834 | semi-supervised · labeled-volumes=2 | Bootstrap Representation Learning for Segmentation on Medical Volumes and SequencesSource quoteL247: Ours │ 0.834 │ 0.892 │ 0.636 │ 0.690 |
| 2021 | MC-Net+ proposed | Dice | 87.10% | semi-supervised · labeled-data=10% · unlabeled-data=90% | Mutual consistency learning for semi-supervised medical image segmentationSource quoteL242: MC-Net+ (Ours) │ 87.10 │ 78.06 │ 6.68 │ 2.00 │ 1.81 │ 2.99 |
| 2021 | MC-Net+ proposed | Dice | 88.51% | semi-supervised · labeled-data=20% · unlabeled-data=80% | Mutual consistency learning for semi-supervised medical image segmentationSource quoteL249: MC-Net+ (Ours) │ 88.51 │ 80.19 │ 5.35 │ 1.54 │ 1.81 │ 2.99 |
| 2021 | CoraNet (2D) proposed | DSC | 86.67% | semi-supervised · setting=2D · modality=MRI · labeled-to-unlabeled-ratio=1:4 | Inconsistency-Aware Uncertainty Estimation for Semi-Supervised Medical Image SegmentationSource quoteL473: Ours │ 86.67 │ 83.21 │ 93.19 │ 10.91 |
| 2021 | CGL baseline | DSC | 0.789 | semi-supervised · labeled-volumes=2 | Bootstrap Representation Learning for Segmentation on Medical Volumes and SequencesSource quoteL246: CGL\cite{chaitanya2020contrastive} │ 0.789 │ 0.872 │ 0.619 │ 0.684 |
| 2021 | MC-Net baseline | Dice | 86.34% | semi-supervised · labeled-data=10% · unlabeled-data=90% | Mutual consistency learning for semi-supervised medical image segmentationSource quoteL241: MC-Net \citep{mcnet} (MICCAI) │ 86.34 │ 76.82 │ 7.08 │ 2.08 │ 2.58 │ 5.39 |
| 2021 | MC-Net baseline | Dice | 87.83% | semi-supervised · labeled-data=20% · unlabeled-data=80% | Mutual consistency learning for semi-supervised medical image segmentationSource quoteL248: MC-Net \citep{mcnet} (MICCAI) │ 87.83 │ 79.14 │ 4.94 │ 1.52 │ 2.58 │ 5.39 |
| 2021 | UA-MT baseline | DSC | 82.02% | semi-supervised · setting=2D · modality=MRI · labeled-to-unlabeled-ratio=1:4 | Inconsistency-Aware Uncertainty Estimation for Semi-Supervised Medical Image SegmentationSource quoteL472: UA-MT \cite{yu2019uncertainty} │ 82.02 │ 83.39 │ 92.21 │ 13.70 |
| 2020 | Adv Bias (proposed) proposed | Average Dice score | 0.686 | split: test · semi-supervised · labeled-subjects=1 | Realistic Adversarial Data Augmentation for MR Image SegmentationSource quoteL125: In the supervised learning setting (no access to unlabelled images), when only one or three labelled subject was available, the proposed method clearly outperformed all baseline methods. For semi-supervised learning, the proposed methods outperformed VAT, especially when only one labelled subject is available (0.686 vs 0.625). The proposed method achieves competitive results compared to the semi-supervised GAN-based method (cGANs) as well. Of note, cGANs adopts two additional GANs to sample geometric transformations and intensity transformations from unlabelled images. This is why it was only compared in the semi-supervised learning setting here. On the contrary, our approach is applicable to both low-shot supervised learning and semi-supervised learning. In addition, cGANs contains more parameters than our method and thus it might be less computationally efficient. |
| 2020 | VAT baseline | Average Dice score | 0.625 | split: test · semi-supervised · labeled-subjects=1 | Realistic Adversarial Data Augmentation for MR Image SegmentationSource quoteL125: In the supervised learning setting (no access to unlabelled images), when only one or three labelled subject was available, the proposed method clearly outperformed all baseline methods. For semi-supervised learning, the proposed methods outperformed VAT, especially when only one labelled subject is available (0.686 vs 0.625). The proposed method achieves competitive results compared to the semi-supervised GAN-based method (cGANs) as well. Of note, cGANs adopts two additional GANs to sample geometric transformations and intensity transformations from unlabelled images. This is why it was only compared in the semi-supervised learning setting here. On the contrary, our approach is applicable to both low-shot supervised learning and semi-supervised learning. In addition, cGANs contains more parameters than our method and thus it might be less computationally efficient. |
| 2018 | ApparentFlow-net (proposed apparent-flow registration) proposed | Dice coefficient | 0.94 | split: val · semi-supervised · region=LVC | Explainable cardiac pathology classification on cine MRI with motion characterization by semi-supervised learning of apparent flowSource quoteL484: A straightforward comparison with prior works on 2D registration methods on the ACDC dataset shows that the ApparentFlow-net performs rather well. Indeed when looking at the Dice coefficients achieved on LVC and RVC, our approach leads to 0.94 and 0.87 respectively (see Table 3). In \cite{Hering:2019}, the authors describe a learning-based method leading to Dice coefficients at best equal to 0.90 on the same structures (based on Fig.3 of \cite{Hering:2019}) and also performances of a non-learning-based method similar to \cite{Ruhaak:2013} with at most 0.80 of Dice. Note however that in this comparison, differences on cross-validation (5-fold v.s. 10-fold), slice selection and ROI determination may hinder the analysis. |
| 2018 | ApparentFlow-net (proposed apparent-flow registration) proposed | Dice coefficient | 0.87 | split: val · semi-supervised · region=RVC | Explainable cardiac pathology classification on cine MRI with motion characterization by semi-supervised learning of apparent flowSource quoteL484: A straightforward comparison with prior works on 2D registration methods on the ACDC dataset shows that the ApparentFlow-net performs rather well. Indeed when looking at the Dice coefficients achieved on LVC and RVC, our approach leads to 0.94 and 0.87 respectively (see Table 3). In \cite{Hering:2019}, the authors describe a learning-based method leading to Dice coefficients at best equal to 0.90 on the same structures (based on Fig.3 of \cite{Hering:2019}) and also performances of a non-learning-based method similar to \cite{Ruhaak:2013} with at most 0.80 of Dice. Note however that in this comparison, differences on cross-validation (5-fold v.s. 10-fold), slice selection and ROI determination may hinder the analysis. |