ACDC

242 papers · 564 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching regime=semi-supervised.

76.881.586.290.9202220242025MC-Net+: 87.1 (2022)MC-Net+: 88.51 (2022)ACTION: 86.7 (2022)ACTION: 89.7 (2022)ACTION: 89.8 (2022)DCPA: 85.86 (2023)Cross-ALD: 80.6 (2023)AdvMIM: 85.4 (2025)TransMedSeg: 89.96 (2025)AugPaint: 42.42 (2025)AugPaint: 77.73 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 14 of 14 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2024MemWarp proposedAverage Dice89.61%split: test · semi-supervised · inference-masks=not-requiredMemWarp: Discontinuity-Preserving Cardiac Registration with Memorized Anatomical Filters
Source quote
L185: MemWarp (ours) │ 89.61 │ 89.30 │ 86.49 │ 93.04 │ 3.93 │ 0.149
2024MemWarp proposedHD953.93 mmsplit: test · semi-supervised · inference-masks=not-requiredMemWarp: Discontinuity-Preserving Cardiac Registration with Memorized Anatomical Filters
Source quote
L185: MemWarp (ours) │ 89.61 │ 89.30 │ 86.49 │ 93.04 │ 3.93 │ 0.149
2024SemSim proposedDSC0.872split: test · semi-supervised · labeled-data=1% (1 case)SemSim: Revisiting Weak-to-Strong Consistency from a Semantic Similarity Perspective for Semi-supervised Medical Image Segmentation
Source quote
L361: SemSim │ {\color[HTML]{FF0000}0.872} │ {\color[HTML]{FF0000}1.8} │ {\color[HTML]{FF0000}0.888} │ {\color[HTML]{FF0000}1.9} │ {\color[HTML]{FF0000}0.896} │ {\color[HTML]{FF0000}2.3} │ 2.60
2024SemSim proposed95HD1.8 mmsplit: test · semi-supervised · labeled-data=1% (1 case)SemSim: Revisiting Weak-to-Strong Consistency from a Semantic Similarity Perspective for Semi-supervised Medical Image Segmentation
Source quote
L361: SemSim │ {\color[HTML]{FF0000}0.872} │ {\color[HTML]{FF0000}1.8} │ {\color[HTML]{FF0000}0.888} │ {\color[HTML]{FF0000}1.9} │ {\color[HTML]{FF0000}0.896} │ {\color[HTML]{FF0000}2.3} │ 2.60
2024Ours-ABD (BCP) proposedDSC↑89.81split: test · semi-supervisedAdaptive Bidirectional Displacement for Semi-Supervised Medical Image Segmentation
Source quote
L505: 89.81
2024Ours-ABD (BCP) proposed95HD↓1.46split: test · semi-supervisedAdaptive Bidirectional Displacement for Semi-Supervised Medical Image Segmentation
Source quote
L507: 1.46
2024Ours-ABD (BCP) proposedASD↓0.49split: test · semi-supervisedAdaptive Bidirectional Displacement for Semi-Supervised Medical Image Segmentation
Source quote
L508: 0.49
2024M-CnT proposedDSC0.753split: test · semi-supervised · labeled-data=3%Combinatorial CNN-Transformer Learning with Manifold Constraints for Semi-supervised Medical Image Segmentation
Source quote
L318: 0.753
2024Slicer Network baselineAverage Dice83.68%split: test · semi-supervisedMemWarp: Discontinuity-Preserving Cardiac Registration with Memorized Anatomical Filters
Source quote
L184: Slicer Network \cite{zhang2024slicer} │ 83.68 │ 84.94 │ 77.97 │ 88.12 │ 6.10 │ 0.099
2024BCP (CVPR’2023) baselineDSC↑88.84split: test · semi-supervisedAdaptive Bidirectional Displacement for Semi-Supervised Medical Image Segmentation
Source quote
L495: 88.84
2024BCP (CVPR’2023) baseline95HD↓3.98split: test · semi-supervisedAdaptive Bidirectional Displacement for Semi-Supervised Medical Image Segmentation
Source quote
L497: 3.98
2024BCP (CVPR’2023) baselineASD↓1.17split: test · semi-supervisedAdaptive Bidirectional Displacement for Semi-Supervised Medical Image Segmentation
Source quote
L498: 1.17
2020Adv Bias (proposed) proposedAverage Dice score0.686split: test · semi-supervised · labeled-subjects=1Realistic Adversarial Data Augmentation for MR Image Segmentation
Source quote
L125: In the supervised learning setting (no access to unlabelled images), when only one or three labelled subject was available, the proposed method clearly outperformed all baseline methods. For semi-supervised learning, the proposed methods outperformed VAT, especially when only one labelled subject is available (0.686 vs 0.625). The proposed method achieves competitive results compared to the semi-supervised GAN-based method (cGANs) as well. Of note, cGANs adopts two additional GANs to sample geometric transformations and intensity transformations from unlabelled images. This is why it was only compared in the semi-supervised learning setting here. On the contrary, our approach is applicable to both low-shot supervised learning and semi-supervised learning. In addition, cGANs contains more parameters than our method and thus it might be less computationally efficient.
2020VAT baselineAverage Dice score0.625split: test · semi-supervised · labeled-subjects=1Realistic Adversarial Data Augmentation for MR Image Segmentation
Source quote
L125: In the supervised learning setting (no access to unlabelled images), when only one or three labelled subject was available, the proposed method clearly outperformed all baseline methods. For semi-supervised learning, the proposed methods outperformed VAT, especially when only one labelled subject is available (0.686 vs 0.625). The proposed method achieves competitive results compared to the semi-supervised GAN-based method (cGANs) as well. Of note, cGANs adopts two additional GANs to sample geometric transformations and intensity transformations from unlabelled images. This is why it was only compared in the semi-supervised learning setting here. On the contrary, our approach is applicable to both low-shot supervised learning and semi-supervised learning. In addition, cGANs contains more parameters than our method and thus it might be less computationally efficient.