ACDC

242 papers · 564 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching regime=semi-supervised.

76.881.586.290.9202220242025MC-Net+: 87.1 (2022)MC-Net+: 88.51 (2022)ACTION: 86.7 (2022)ACTION: 89.7 (2022)ACTION: 89.8 (2022)DCPA: 85.86 (2023)Cross-ALD: 80.6 (2023)AdvMIM: 85.4 (2025)TransMedSeg: 89.96 (2025)AugPaint: 42.42 (2025)AugPaint: 77.73 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 40 of 40 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025ICTC proposedDice88.22semi-supervised · labeled-cases=7 (10%) · unlabeled-cases=63An Intra- and Cross-frame Topological Consistency Scheme for Semi-supervised Atherosclerotic Coronary Plaque Segmentation
Source quote
L182: ICTC(Ours) │ 7(10%) │ 63 │ 88.22 │ 78.72 │ 7.48 │ 1.58
2025ICTC proposedJaccard (Jac)78.72semi-supervised · labeled-cases=7 (10%) · unlabeled-cases=63An Intra- and Cross-frame Topological Consistency Scheme for Semi-supervised Atherosclerotic Coronary Plaque Segmentation
Source quote
L182: ICTC(Ours) │ 7(10%) │ 63 │ 88.22 │ 78.72 │ 7.48 │ 1.58
2025TransMedSeg proposedDice89.96%semi-supervised · labeled-data=10%TransMedSeg: A Transferable Semantic Framework for Semi-Supervised Medical Image Segmentation
Source quote
L168: TransMedSeg │ 88.14 │ 79.48 │ 3.42 │ 0.97 │ 89.96 │ 82.31 │ 1.61 │ 0.64
2025AugPaint proposedDice42.42%semi-supervised · labeled-cases=1Inpainting is All You Need: A Diffusion-based Augmentation Method for Semi-supervised Medical Image Segmentation
Source quote
L286: \multirow{4}{*}{ACDC} │ AugPaint │ 42.42 │ 44.15 │ 77.73
2025AugPaint proposedDice77.73%semi-supervised · labeled-cases=5Inpainting is All You Need: A Diffusion-based Augmentation Method for Semi-supervised Medical Image Segmentation
Source quote
L286: \multirow{4}{*}{ACDC} │ AugPaint │ 42.42 │ 44.15 │ 77.73
2025AdvMIM proposedDice85.4%semi-supervised · labeled-data=3%AdvMIM: Adversarial Masked Image Modeling for Semi-supervised Medical Image Segmentation
Source quote
L134: AdvMIM │ 85.4_{(10.1\textcolor{green}{\uparrow})} │ 2.0_{(8.7\textcolor{red}{\downarrow})} │ 89.0_{(0.6\textcolor{green}{\uparrow})} │ 1.3_{(3.1\textcolor{red}{\downarrow})} │ 66.3_{(1.0\textcolor{green}{\uparrow})} │ 22.7_{(9.9\textcolor{red}{\downarrow})} │ 74.8_{(3.4\textcolor{green}{\uparrow})} │ 15.5_{(15.7\textcolor{red}{\downarrow})} │ 79.8_{(1.9\textcolor{green}{\uparrow})} │ 22.2_{(9.9\textcolor{red}{\downarrow})} │ 81.8_{(0.7\textcolor{green}{\uparrow})} │ 19.5_{(4.9\textcolor{red}{\downarrow})}
2025Ours (switching Dual-Student framework with LA-EMA) proposedDice90.67semi-supervised · labeled-data=7/70 patientsAdaptive Knowledge Transferring with Switching Dual-Student Framework for Semi-Supervised Medical Image Segmentation
Source quote
L429: 90.67 83.41
2025Ours (switching Dual-Student framework with LA-EMA) proposedJaccard83.41%semi-supervised · labeled-data=7/70 patientsAdaptive Knowledge Transferring with Switching Dual-Student Framework for Semi-Supervised Medical Image Segmentation
Source quote
L429: 90.67 83.41
2025Multi-Prototype-based Embedding Refinement proposedDice88.64semi-supervised · labeled-cases=3 (5%) · unlabeled-cases=67 (95%)Multi-Prototype-based Embedding Refinement for Medical Image Segmentation
Source quote
L168: Ours │ 88.64 │ 80.21 │ 1.51 │ 0.60
2025Multi-Prototype-based Embedding Refinement proposedDice89.69semi-supervised · labeled-cases=7 (10%) · unlabeled-cases=63 (90%)Multi-Prototype-based Embedding Refinement for Medical Image Segmentation
Source quote
L177: Ours │ 89.69 │ 81.88 │ 1.65 │ 0.56
2024MemWarp proposedAverage Dice89.61%split: test · semi-supervised · inference-masks=not-requiredMemWarp: Discontinuity-Preserving Cardiac Registration with Memorized Anatomical Filters
Source quote
L185: MemWarp (ours) │ 89.61 │ 89.30 │ 86.49 │ 93.04 │ 3.93 │ 0.149
2024MemWarp proposedHD953.93 mmsplit: test · semi-supervised · inference-masks=not-requiredMemWarp: Discontinuity-Preserving Cardiac Registration with Memorized Anatomical Filters
Source quote
L185: MemWarp (ours) │ 89.61 │ 89.30 │ 86.49 │ 93.04 │ 3.93 │ 0.149
2024SemSim proposedDSC0.872split: test · semi-supervised · labeled-data=1% (1 case)SemSim: Revisiting Weak-to-Strong Consistency from a Semantic Similarity Perspective for Semi-supervised Medical Image Segmentation
Source quote
L361: SemSim │ {\color[HTML]{FF0000}0.872} │ {\color[HTML]{FF0000}1.8} │ {\color[HTML]{FF0000}0.888} │ {\color[HTML]{FF0000}1.9} │ {\color[HTML]{FF0000}0.896} │ {\color[HTML]{FF0000}2.3} │ 2.60
2024SemSim proposed95HD1.8 mmsplit: test · semi-supervised · labeled-data=1% (1 case)SemSim: Revisiting Weak-to-Strong Consistency from a Semantic Similarity Perspective for Semi-supervised Medical Image Segmentation
Source quote
L361: SemSim │ {\color[HTML]{FF0000}0.872} │ {\color[HTML]{FF0000}1.8} │ {\color[HTML]{FF0000}0.888} │ {\color[HTML]{FF0000}1.9} │ {\color[HTML]{FF0000}0.896} │ {\color[HTML]{FF0000}2.3} │ 2.60
2024CPC-SAM proposedDSC85.56%semi-supervised · labeled-data=1/70Cross Prompting Consistency with Segment Anything Model for Semi-supervised Medical Image Segmentation
Source quote
L153: CPC-SAM (ours) │ {10/431} │ {71.20} │ {61.15} │ {100.22} │ 37.86 │ {1/70} │ {85.56} │ {75.74} │ {9.19} │ 2.84
2024Ours-ABD (BCP) proposedDSC↑89.81split: test · semi-supervisedAdaptive Bidirectional Displacement for Semi-Supervised Medical Image Segmentation
Source quote
L505: 89.81
2024Ours-ABD (BCP) proposed95HD↓1.46split: test · semi-supervisedAdaptive Bidirectional Displacement for Semi-Supervised Medical Image Segmentation
Source quote
L507: 1.46
2024Ours-ABD (BCP) proposedASD↓0.49split: test · semi-supervisedAdaptive Bidirectional Displacement for Semi-Supervised Medical Image Segmentation
Source quote
L508: 0.49
2024M-CnT proposedDSC0.753split: test · semi-supervised · labeled-data=3%Combinatorial CNN-Transformer Learning with Manifold Constraints for Semi-supervised Medical Image Segmentation
Source quote
L318: 0.753
2023DCPA proposedDice85.86%semi-supervised · labeled_scans=3 (5%) · dimensionality=2D · unlabeled_scans=67 (95%)Dual-Decoder Consistency via Pseudo-Labels Guided Data Augmentation for Semi-Supervised Medical Image Segmentation
Source quote
L288: Ours │ 85.86 │ 76.13 │ 5.83 │ 2.03
2023BCP (α=0.5) proposedDice87.59semi-supervised · alpha=0.5 · input=2D slices · classes=four-class average · labeled-data=5% (3 scans) · unlabeled-data=95% (67 scans)Bidirectional Copy-Paste for Semi-Supervised Medical Image Segmentation
Source quote
L342: 88.02 │ 78.72 │ 7.90 │ 2.15 │ \multirow{4}{*}{3(5%)} │ \multicolumn{1}{c|}{\multirow{4}{*}{67(95%)}} │ 87.59 │ 78.67 │ 1.90 │ 0.67
2023Cross-ALD proposedDice (%)80.6%semi-supervised · backbone=U-Net · labeled-data=5%Cross-adversarial local distribution regularization for semi-supervised medical image segmentation
Source quote
L142: Cross-ALD (Ours) │ 80.6 │ 69.08 │ 5.96 │ 1.9 │ 1.83 │ 2.99
2023ARCO-SAG proposedaveraged Dice84.9%semi-supervised · labeled-data=1%Rethinking Semi-Supervised Medical Image Segmentation: A Variance-Reduction Perspective
Source quote
L187: Our \texttt{ARCO-SAG}\xspace achieves \{84.9%, 87.1%, 88.5%\}, \{64.1%, 67.3%, 69.4%\}, \{86.1%, 88.6%, 89.3%\}, \{91.5%, 92.5%, 92.6%\}, \{73.2%, 86.9%, 89.1%\} in averaged Dice across ACDC, LiTS, MMWHS, MP-MRI, and LA.
2023MCSC (Multi-Scale Cross Supervised Contrastive Learning) proposedDSC89.4%semi-supervised · labeled-cases=7 · labeled-fraction=10%Multi-Scale Cross Contrastive Learning for Semi-Supervised Medical Image Segmentation
Source quote
L165: More importantly, it achieves 2.3mm HD, significantly better than even the fully supervised U-Net and BATFormer, which achieve 4.0 and 8.0 respectively. It also demonstrates competitive DSC of 89.4 %, compared with 91.7 % and 92.8 % of U-Net and BATFormer.
2023MCSC (Multi-Scale Cross Supervised Contrastive Learning) proposedHD2.3 mmsemi-supervised · labeled-cases=7 · labeled-fraction=10%Multi-Scale Cross Contrastive Learning for Semi-Supervised Medical Image Segmentation
Source quote
L165: More importantly, it achieves 2.3mm HD, significantly better than even the fully supervised U-Net and BATFormer, which achieve 4.0 and 8.0 respectively. It also demonstrates competitive DSC of 89.4 %, compared with 91.7 % and 92.8 % of U-Net and BATFormer.
2023MCSC (Multi-Scale Cross Supervised Contrastive Learning) proposedDSC73.6%semi-supervised · labeled-cases=3 · labeled-fraction=5%Multi-Scale Cross Contrastive Learning for Semi-Supervised Medical Image Segmentation
Source quote
L191: MCSC (Ours) │ {\bf 73.6 } │ {\bf 10.5 } │ {\bf70.0} │ {\bf8.8} │ {\bf 79.2} │ {\bf14.9} │ {\bf71.7} │ {\bf7.8}
2023SCP-Net proposedDSC89.69semi-supervised · labeled-scans=14 · unlabeled-scans=126Self-aware and Cross-sample Prototypical Learning for Semi-supervised Medical Image Segmentation
Source quote
L209: SCP-Net │ 14 │ 126 │ 89.26 │ 0.77 │ 87.11 │ 0.51 │ 92.70 │ 0.92 │ 89.69 │ 0.73
2023SCP-Net proposedASSD0.73semi-supervised · labeled-scans=14 · unlabeled-scans=126Self-aware and Cross-sample Prototypical Learning for Semi-supervised Medical Image Segmentation
Source quote
L209: SCP-Net │ 14 │ 126 │ 89.26 │ 0.77 │ 87.11 │ 0.51 │ 92.70 │ 0.92 │ 89.69 │ 0.73
2022ACTION proposedaveraged Dice87.5%semi-supervised · labeled-cases=3Bootstrapping Semi-supervised Medical Image Segmentation with Anatomical-Aware Contrastive Distillation
Source quote
L384: Table \ref{table:acdc_main} shows the evaluation results on ACDC dataset under two unlabeled settings (3 or 7 labeled cases). ACTION can substantially improve results on two unlabeled settings, greatly outperforming the previous state-of-the-art SSL methods. Specifically, our ACTION, trained on 3 labeled cases, dramatically improves the previous best averaged Dice score from 73.6% to 87.5% by a large margin, and even matches previous SSL methods using 7 labeled cases. When using 7 labeled cases, ACTION further pushes the state-of-the-art results to 89.7% in Dice. We observe that the gains are more pronounced on the two categories(i.e., RV and Myo), and our ACTION achieves 89.8% and 86.7% in terms of Dice, performing competitive or even better than the supervised baseline (89.2% and 86.7%). As shown in Figure \ref{fig:vis_acdc}, we can see the clear advantage of ACTION, where the boundaries of different regions are clearly sharper and more accurate such as RV and Myo regions. Table \ref{table:lits_main} also shows the evaluation results on LiTS dataset under two unlabeled settings (5% or 10% labeled cases). On both two labeled settings, ACTION significantly outperforms all the state-of-the-art methods by a significant margin. As shown in Figure \ref{fig:vis_lits}, ACTION achieves consistently sharp and accurate object boundaries compared to other SSL methods.
2022ACTION proposedDice89.7%semi-supervised · labeled-cases=7Bootstrapping Semi-supervised Medical Image Segmentation with Anatomical-Aware Contrastive Distillation
Source quote
L384: Table \ref{table:acdc_main} shows the evaluation results on ACDC dataset under two unlabeled settings (3 or 7 labeled cases). ACTION can substantially improve results on two unlabeled settings, greatly outperforming the previous state-of-the-art SSL methods. Specifically, our ACTION, trained on 3 labeled cases, dramatically improves the previous best averaged Dice score from 73.6% to 87.5% by a large margin, and even matches previous SSL methods using 7 labeled cases. When using 7 labeled cases, ACTION further pushes the state-of-the-art results to 89.7% in Dice. We observe that the gains are more pronounced on the two categories(i.e., RV and Myo), and our ACTION achieves 89.8% and 86.7% in terms of Dice, performing competitive or even better than the supervised baseline (89.2% and 86.7%). As shown in Figure \ref{fig:vis_acdc}, we can see the clear advantage of ACTION, where the boundaries of different regions are clearly sharper and more accurate such as RV and Myo regions. Table \ref{table:lits_main} also shows the evaluation results on LiTS dataset under two unlabeled settings (5% or 10% labeled cases). On both two labeled settings, ACTION significantly outperforms all the state-of-the-art methods by a significant margin. As shown in Figure \ref{fig:vis_lits}, ACTION achieves consistently sharp and accurate object boundaries compared to other SSL methods.
2022ACTION proposedDice89.8%semi-supervised · labeled-cases=7 · anatomical-category=RVBootstrapping Semi-supervised Medical Image Segmentation with Anatomical-Aware Contrastive Distillation
Source quote
L384: Table \ref{table:acdc_main} shows the evaluation results on ACDC dataset under two unlabeled settings (3 or 7 labeled cases). ACTION can substantially improve results on two unlabeled settings, greatly outperforming the previous state-of-the-art SSL methods. Specifically, our ACTION, trained on 3 labeled cases, dramatically improves the previous best averaged Dice score from 73.6% to 87.5% by a large margin, and even matches previous SSL methods using 7 labeled cases. When using 7 labeled cases, ACTION further pushes the state-of-the-art results to 89.7% in Dice. We observe that the gains are more pronounced on the two categories(i.e., RV and Myo), and our ACTION achieves 89.8% and 86.7% in terms of Dice, performing competitive or even better than the supervised baseline (89.2% and 86.7%). As shown in Figure \ref{fig:vis_acdc}, we can see the clear advantage of ACTION, where the boundaries of different regions are clearly sharper and more accurate such as RV and Myo regions. Table \ref{table:lits_main} also shows the evaluation results on LiTS dataset under two unlabeled settings (5% or 10% labeled cases). On both two labeled settings, ACTION significantly outperforms all the state-of-the-art methods by a significant margin. As shown in Figure \ref{fig:vis_lits}, ACTION achieves consistently sharp and accurate object boundaries compared to other SSL methods.
2022ACTION proposedDice86.7%semi-supervised · labeled-cases=7 · anatomical-category=MyoBootstrapping Semi-supervised Medical Image Segmentation with Anatomical-Aware Contrastive Distillation
Source quote
L384: Table \ref{table:acdc_main} shows the evaluation results on ACDC dataset under two unlabeled settings (3 or 7 labeled cases). ACTION can substantially improve results on two unlabeled settings, greatly outperforming the previous state-of-the-art SSL methods. Specifically, our ACTION, trained on 3 labeled cases, dramatically improves the previous best averaged Dice score from 73.6% to 87.5% by a large margin, and even matches previous SSL methods using 7 labeled cases. When using 7 labeled cases, ACTION further pushes the state-of-the-art results to 89.7% in Dice. We observe that the gains are more pronounced on the two categories(i.e., RV and Myo), and our ACTION achieves 89.8% and 86.7% in terms of Dice, performing competitive or even better than the supervised baseline (89.2% and 86.7%). As shown in Figure \ref{fig:vis_acdc}, we can see the clear advantage of ACTION, where the boundaries of different regions are clearly sharper and more accurate such as RV and Myo regions. Table \ref{table:lits_main} also shows the evaluation results on LiTS dataset under two unlabeled settings (5% or 10% labeled cases). On both two labeled settings, ACTION significantly outperforms all the state-of-the-art methods by a significant margin. As shown in Figure \ref{fig:vis_lits}, ACTION achieves consistently sharp and accurate object boundaries compared to other SSL methods.
2022Proposed method (RCS + DTS + fuzzy fusion) proposedAverage DSC0.889semi-supervised · labeled-data=10%Addressing Class Imbalance in Semi-supervised Image Segmentation: A Study on Cardiac MRI
Source quote
L148: 0.889
2021Bootstrap representation learning (Ours; slice prediction with foreground-background calibration) proposedDSC0.834semi-supervised · labeled-volumes=2Bootstrap Representation Learning for Segmentation on Medical Volumes and Sequences
Source quote
L247: Ours │ 0.834 │ 0.892 │ 0.636 │ 0.690
2021MC-Net+ proposedDice87.10%semi-supervised · labeled-data=10% · unlabeled-data=90%Mutual consistency learning for semi-supervised medical image segmentation
Source quote
L242: MC-Net+ (Ours) │ 87.10 │ 78.06 │ 6.68 │ 2.00 │ 1.81 │ 2.99
2021MC-Net+ proposedDice88.51%semi-supervised · labeled-data=20% · unlabeled-data=80%Mutual consistency learning for semi-supervised medical image segmentation
Source quote
L249: MC-Net+ (Ours) │ 88.51 │ 80.19 │ 5.35 │ 1.54 │ 1.81 │ 2.99
2021CoraNet (2D) proposedDSC86.67%semi-supervised · setting=2D · modality=MRI · labeled-to-unlabeled-ratio=1:4Inconsistency-Aware Uncertainty Estimation for Semi-Supervised Medical Image Segmentation
Source quote
L473: Ours │ 86.67 │ 83.21 │ 93.19 │ 10.91
2020Adv Bias (proposed) proposedAverage Dice score0.686split: test · semi-supervised · labeled-subjects=1Realistic Adversarial Data Augmentation for MR Image Segmentation
Source quote
L125: In the supervised learning setting (no access to unlabelled images), when only one or three labelled subject was available, the proposed method clearly outperformed all baseline methods. For semi-supervised learning, the proposed methods outperformed VAT, especially when only one labelled subject is available (0.686 vs 0.625). The proposed method achieves competitive results compared to the semi-supervised GAN-based method (cGANs) as well. Of note, cGANs adopts two additional GANs to sample geometric transformations and intensity transformations from unlabelled images. This is why it was only compared in the semi-supervised learning setting here. On the contrary, our approach is applicable to both low-shot supervised learning and semi-supervised learning. In addition, cGANs contains more parameters than our method and thus it might be less computationally efficient.
2018ApparentFlow-net (proposed apparent-flow registration) proposedDice coefficient0.94split: val · semi-supervised · region=LVCExplainable cardiac pathology classification on cine MRI with motion characterization by semi-supervised learning of apparent flow
Source quote
L484: A straightforward comparison with prior works on 2D registration methods on the ACDC dataset shows that the ApparentFlow-net performs rather well. Indeed when looking at the Dice coefficients achieved on LVC and RVC, our approach leads to 0.94 and 0.87 respectively (see Table 3). In \cite{Hering:2019}, the authors describe a learning-based method leading to Dice coefficients at best equal to 0.90 on the same structures (based on Fig.3 of \cite{Hering:2019}) and also performances of a non-learning-based method similar to \cite{Ruhaak:2013} with at most 0.80 of Dice. Note however that in this comparison, differences on cross-validation (5-fold v.s. 10-fold), slice selection and ROI determination may hinder the analysis.
2018ApparentFlow-net (proposed apparent-flow registration) proposedDice coefficient0.87split: val · semi-supervised · region=RVCExplainable cardiac pathology classification on cine MRI with motion characterization by semi-supervised learning of apparent flow
Source quote
L484: A straightforward comparison with prior works on 2D registration methods on the ACDC dataset shows that the ApparentFlow-net performs rather well. Indeed when looking at the Dice coefficients achieved on LVC and RVC, our approach leads to 0.94 and 0.87 respectively (see Table 3). In \cite{Hering:2019}, the authors describe a learning-based method leading to Dice coefficients at best equal to 0.90 on the same structures (based on Fig.3 of \cite{Hering:2019}) and also performances of a non-learning-based method similar to \cite{Ruhaak:2013} with at most 0.80 of Dice. Note however that in this comparison, differences on cross-validation (5-fold v.s. 10-fold), slice selection and ROI determination may hinder the analysis.