ACDC

242 papers · 564 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching regime=semi-supervised.

76.881.586.290.9202220242025MC-Net+: 87.1 (2022)MC-Net+: 88.51 (2022)ACTION: 86.7 (2022)ACTION: 89.7 (2022)ACTION: 89.8 (2022)DCPA: 85.86 (2023)Cross-ALD: 80.6 (2023)AdvMIM: 85.4 (2025)TransMedSeg: 89.96 (2025)AugPaint: 42.42 (2025)AugPaint: 77.73 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 21 of 21 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025FRBNet proposedmIoU61.6%fine-tuned · epochs=20K iterations · subset=15 categories; excludes truck, bus, rider, motorcycle · backbone=DeepLabV3+ with ResNet-50FRBNet: Revisiting Low-Light Vision through Frequency-Domain Radial Basis Network
Source quote
L349: 94.4 │ 75.5 │ 79.7 │ 46.0 │ \uline{45.4} │ \uline{52.3} │ 64.9 │ 50.8 │ 72.2 │ 9.5 │ 84.2 │ 40.9 │ 70.4 │ 88.7 │ 49.3 │ 61.6
2024SAL proposedmean Dice5.2%fine-tuned · labeled-subjects=2Self-Supervised Alignment Learning for Medical Image Segmentation
Source quote
L111: To show the effectiveness, our proposed method is compared with the existing SSL pre-training approaches, Rotation~\cite{gidaris2018unsupervised}, PIRL~\cite{misra2020self}, SimCLR~\cite{chen2020simple}, GCL~\cite{chaitanya2020contrastive}, PCL~\cite{zeng2021positional} and CCrop~\cite{peng2022crafting}. Table~\ref{tab:sota_acdc} shows the results on ACDC dataset. M refers to the number of subjects adopted in fine-tuning. In Table~\ref{tab:sota_acdc}, as M increases from 2 to 80, the mean Dice of each method continuously rises. When M is low, increasing labeled samples significantly improves the mean Dice by 14.6%-37.3%. When M is high (from 10 to 80), the great increase of samples only brings smaller improvements of 3.9%-10.3% mean Dice. The `Random' strategy is to randomly initialize model weights without any pre-training. It can be seen that when using all training samples (M=80), the mean Dice of the Random and most pre-training methods (including ours) are very close (92.7%-92.8%). It indicates that the SSL-based pre-training usually shows the effectiveness when training samples are not completely labeled. For M=2, our method outperforms the second-best PCL by 5.2% mean Dice. For M=6 and M=10, our framework surpasses the second best by 0.5%-1.9%. These results suggest that the proposed SAL framework is competitive with existing pre-training approaches.
2024Liouna (pre-trained; downstream fine-tuning) proposedmean Intersection over Union (mIoU)54.52%fine-tuned · training-steps=10KLiouna: Biologically Plausible Learning for Efficient Pre-Training of Transferrable Deep Models
Source quote
L296: 54.52%, close to SimCLR’s mIoU of 55.08%. Liouna also exhibits a Mean Absolute Error (MAE) loss of 1.92 on the
2024Proposed multitask learning (MTL; relative orientation and relative location regression) proposedmean Dice0.814fine-tuned · subset=4 subjects · modality=SAX CMRSelf-supervised learning for medical image data with anatomy-oriented imaging planes
Source quote
L462: When only four subjects are used for fine-tuning, our MTL achieves a reasonable performance of mean Dice at 0.814 and mean ASSD at 1.917 mm, which are comparable to training from scratch with 16 subjects (mean Dice at 0.815 and mean ASSD at 2.064 mm).
2024Proposed multitask learning (MTL; relative orientation and relative location regression) proposed non-standard sliceAUC0.839split: test · fine-tuned · subset=1 subject · classifier=100-tree random forestSelf-supervised learning for medical image data with anatomy-oriented imaging planes
Source quote
L495: MTL │ 0.839 │ 0.903 │ 0.959 │ 0.959 │ 0.972
2024SimCLR (pre-trained; downstream fine-tuning) baselinemean Intersection over Union (mIoU)55.08%fine-tuned · training-steps=10KLiouna: Biologically Plausible Learning for Efficient Pre-Training of Transferrable Deep Models
Source quote
L296: 54.52%, close to SimCLR’s mIoU of 55.08%. Liouna also exhibits a Mean Absolute Error (MAE) loss of 1.92 on the
2024Training from scratch (None) baselinemean Dice0.815fine-tuned · subset=16 subjects · modality=SAX CMRSelf-supervised learning for medical image data with anatomy-oriented imaging planes
Source quote
L462: When only four subjects are used for fine-tuning, our MTL achieves a reasonable performance of mean Dice at 0.814 and mean ASSD at 1.917 mm, which are comparable to training from scratch with 16 subjects (mean Dice at 0.815 and mean ASSD at 2.064 mm).
2024Training from scratch (None) baseline non-standard sliceAUC0.608split: test · fine-tuned · subset=1 subject · classifier=100-tree random forestSelf-supervised learning for medical image data with anatomy-oriented imaging planes
Source quote
L485: None │ 0.608 │ 0.825 │ 0.861 │ 0.909 │ 0.920
2023DIAMANT (dual encoder; all four attention skip connections enabled) proposedDSC91.90%fine-tuned · backbone=ViT-S/16DIAMANT: Dual Image-Attention Map Encoders For Medical Image Segmentation
Source quote
L274: 1 │ 1 │ 1 │ 1 │ 90.53 │ 89.52 │ 95.63 │ 91.90
2023MACL proposedHD955.23fine-tuned · pretraining=CHD (CT) · labeled-data=10%Multi-level Asymmetric Contrastive Learning for Medical Image Segmentation Pre-training
Source quote
L456: Our proposed MACL also achieves the lowest (best) HD95, such as 5.23 on ACDC, 5.91 on MMWHS and 22.38 on HVSMR, 6.93 on Spleen and 21.53 on ISIC.
2023full fine-tuning baselineDice(%)88.21%fine-tuned · backbone=SegFormer-B4 · pretraining=ADE20KDVPT: Dynamic Visual Prompt Tuning of large pre-trained models for medical image analysis
Source quote
L210: full fine-tuning │ 61.6383 │ 55.77 │ 12.03 │ 91.79 │ 86.86 │ 92.88 │ 87.31 │ 74.12 │ 17.37 │ 88.21 │ 2.66
2022Doubly contrastive image- and pixel-level supervised method, SwiftNet (ResNet-18) proposedmIoU66.24%fine-tuned · backbone=ResNet-18Doubly Contrastive End-to-End Semantic Segmentation for Autonomous Driving under Adverse Weather
Source quote
L214: (g) │ +Image- and Pixel-level Supervised Contrasts (Ours)^\dag │ 66.24 │ 75.38 │ 48.82 │ 65.79 │ 68.42
2022SwiftNet (ResNet-18), self-supervised and pixel-level supervised contrasts ablationmIoU66.97%fine-tuned · backbone=ResNet-18Doubly Contrastive End-to-End Semantic Segmentation for Autonomous Driving under Adverse Weather
Source quote
L213: (f) │ +Self-supervised and Pixel-level Supervised Contrasts^\dag │ 66.97 │ 74.05 │ 49.10 │ 67.85 │ 69.69
2022Swin-Unet baselineDSC88.07%split: test · fine-tuned · subset=20 patients · backbone=Swin-UnetOptimizing Vision Transformers for Medical Image Segmentation
Source quote
L134: Swin-Unet │ 88.07 │ 85.77 │ 84.42 │ 94.03
2022Swin-Unet baselineRV DSC85.77%split: test · fine-tuned · subset=20 patients · backbone=Swin-UnetOptimizing Vision Transformers for Medical Image Segmentation
Source quote
L134: Swin-Unet │ 88.07 │ 85.77 │ 84.42 │ 94.03
2021MIASSR proposedFID153.5fine-tuned · pretraining=OASIS-brain · fine-tuning-steps=10000MIASSR: An Approach for Medical Image Arbitrary Scale Super-Resolution
Source quote
L210: MIASSR(ours) │ 36.89 / 62.28 │ 36.86 / 61.06 │ 34.28 / 46.74 │ 35.91 / 68.45 │ 30.94 / 153.5 │ 43.21 / 37.66
2020Proposed deep generative model-based quality control proposedPearson correlation coefficient r0.97fine-tuned · n=100 · subgroups=5 · segmentation-model-training=UK Biobank; no fine-tuningDeep Generative Model-Based Quality Control for Cardiac MRI Segmentation
Source quote
L99: Quality control performance is assessed in terms of Dice metric prediction accuracy. Pearson correlation coefficient r and mean absolute error (MAE) between predicted Dice and real Dice are calculated. Table 1 compares the quantitative performance of the methods and Fig.\ref{figure3} visualises the predictions. On UK Biobank dataset, the hand-crafted feature method performed the worst. The proposed method achieved a similar performance (r=0.96, MAE=0.07) as the CNN regression method (r=0.97, MAE=0.06). However, on ACDC dataset, the proposed method (r=0.97, MAE=0.03) outperformed the CNN regression method (r=0.97, MAE=0.17) with a smaller MAE. As shown in Fig. \ref{figure3}, on ACDC dataset, the prediction of the proposed method aligns well with the identity line, whereas the CNN regression method clearly deviates from the line, even though the r coefficient is still high.
2020Proposed deep generative model-based quality control proposedMean absolute error (MAE)0.03fine-tuned · n=100 · subgroups=5 · segmentation-model-training=UK Biobank; no fine-tuningDeep Generative Model-Based Quality Control for Cardiac MRI Segmentation
Source quote
L99: Quality control performance is assessed in terms of Dice metric prediction accuracy. Pearson correlation coefficient r and mean absolute error (MAE) between predicted Dice and real Dice are calculated. Table 1 compares the quantitative performance of the methods and Fig.\ref{figure3} visualises the predictions. On UK Biobank dataset, the hand-crafted feature method performed the worst. The proposed method achieved a similar performance (r=0.96, MAE=0.07) as the CNN regression method (r=0.97, MAE=0.06). However, on ACDC dataset, the proposed method (r=0.97, MAE=0.03) outperformed the CNN regression method (r=0.97, MAE=0.17) with a smaller MAE. As shown in Fig. \ref{figure3}, on ACDC dataset, the prediction of the proposed method aligns well with the identity line, whereas the CNN regression method clearly deviates from the line, even though the r coefficient is still high.
2020G^D encoder + random-initialized decoder proposedMean Dice score (DSC)0.784split: test · fine-tuned · decoder=random-initialized · labeled-volumes=2Contrastive learning of global and local features for medical image segmentation with limited annotations
Source quote
L494: {G (D)} │ {random init} │ ACDC │ \multicolumn{3}{|l|}{0.691} │ \multicolumn{3}{|l|}{0.784} │ \multicolumn{3}{|l|}{0.870}
2020CNN regression method (ResNet-18 backbone) baselinePearson correlation coefficient r0.97fine-tuned · n=100 · backbone=ResNet-18 · subgroups=5 · segmentation-model-training=UK Biobank; no fine-tuningDeep Generative Model-Based Quality Control for Cardiac MRI Segmentation
Source quote
L99: Quality control performance is assessed in terms of Dice metric prediction accuracy. Pearson correlation coefficient r and mean absolute error (MAE) between predicted Dice and real Dice are calculated. Table 1 compares the quantitative performance of the methods and Fig.\ref{figure3} visualises the predictions. On UK Biobank dataset, the hand-crafted feature method performed the worst. The proposed method achieved a similar performance (r=0.96, MAE=0.07) as the CNN regression method (r=0.97, MAE=0.06). However, on ACDC dataset, the proposed method (r=0.97, MAE=0.03) outperformed the CNN regression method (r=0.97, MAE=0.17) with a smaller MAE. As shown in Fig. \ref{figure3}, on ACDC dataset, the prediction of the proposed method aligns well with the identity line, whereas the CNN regression method clearly deviates from the line, even though the r coefficient is still high.
2020CNN regression method (ResNet-18 backbone) baselineMean absolute error (MAE)0.17fine-tuned · n=100 · backbone=ResNet-18 · subgroups=5 · segmentation-model-training=UK Biobank; no fine-tuningDeep Generative Model-Based Quality Control for Cardiac MRI Segmentation
Source quote
L99: Quality control performance is assessed in terms of Dice metric prediction accuracy. Pearson correlation coefficient r and mean absolute error (MAE) between predicted Dice and real Dice are calculated. Table 1 compares the quantitative performance of the methods and Fig.\ref{figure3} visualises the predictions. On UK Biobank dataset, the hand-crafted feature method performed the worst. The proposed method achieved a similar performance (r=0.96, MAE=0.07) as the CNN regression method (r=0.97, MAE=0.06). However, on ACDC dataset, the proposed method (r=0.97, MAE=0.03) outperformed the CNN regression method (r=0.97, MAE=0.17) with a smaller MAE. As shown in Fig. \ref{figure3}, on ACDC dataset, the prediction of the proposed method aligns well with the identity line, whereas the CNN regression method clearly deviates from the line, even though the r coefficient is still high.