ACDC
242 papers · 564 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching regime=semi-supervised.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | TransMedSeg SOTA frontier | 89.96% | 2025-05-01 | labeled-data=10% · 7 labeled scans (10%) and 63 unlabeled scans (90%). | TransMedSeg: A Transferable Semantic Framework for Semi-Supervised Medical Image SegmentationSource quoteTransMedSeg │ 88.14 │ 79.48 │ 3.42 │ 0.97 │ 89.96 │ 82.31 │ 1.61 │ 0.64 |
| 2 | ACTION SOTA frontier (+2 variants) | 89.8% | 2022-06-01 | labeled-cases=7 · anatomical-category=RV · 7-labeled-case setting; RV category | Bootstrapping Semi-supervised Medical Image Segmentation with Anatomical-Aware Contrastive DistillationSource quoteTable \ref{table:acdc_main} shows the evaluation results on ACDC dataset under two unlabeled settings (3 or 7 labeled cases). ACTION can substantially improve results on two unlabeled settings, greatly outperforming the previous state-of-the-art SSL methods. Specifically, our ACTION, trained on 3 labeled cases, dramatically improves the previous best averaged Dice score from 73.6% to 87.5% by a large margin, and even matches previous SSL methods using 7 labeled cases. When using 7 labeled cases, ACTION further pushes the state-of-the-art results to 89.7% in Dice. We observe that the gains are more pronounced on the two categories(i.e., RV and Myo), and our ACTION achieves 89.8% and 86.7% in terms of Dice, performing competitive or even better than the supervised baseline (89.2% and 86.7%). As shown in Figure \ref{fig:vis_acdc}, we can see the clear advantage of ACTION, where the boundaries of different regions are clearly sharper and more accurate such as RV and Myo regions. Table \ref{table:lits_main} also shows the evaluation results on LiTS dataset under two unlabeled settings (5% or 10% labeled cases). On both two labeled settings, ACTION significantly outperforms all the state-of-the-art methods by a significant margin. As shown in Figure \ref{fig:vis_lits}, ACTION achieves consistently sharp and accurate object boundaries compared to other SSL methods. |
| 3 | MC-Net+ SOTA frontier (+1 variant) | 88.51% | 2022-01-01 | labeled-data=20% · unlabeled-data=80% · 20% labeled and 80% unlabeled scans; average over myocardium, left ventricle, and rig… | Mutual consistency learning for semi-supervised medical image segmentationSource quoteMC-Net+ (Ours) │ 88.51 │ 80.19 │ 5.35 │ 1.54 │ 1.81 │ 2.99 |
| 4 | DCPA | 85.86% | 2023-08-01 | labeled_scans=3 (5%) · dimensionality=2D · unlabeled_scans=67 (95%) · 2D segmentation; 3 labeled scans (5%) and 67 unlabeled scans (95%); Dice averaged acr… | Dual-Decoder Consistency via Pseudo-Labels Guided Data Augmentation for Semi-Supervised Medical Image SegmentationSource quoteOurs │ 85.86 │ 76.13 │ 5.83 │ 2.03 |
| 5 | AdvMIM | 85.4% | 2025-01-01 | labeled-data=3% · 3% labeled-data partition; semi-supervised medical image segmentation. | AdvMIM: Adversarial Masked Image Modeling for Semi-supervised Medical Image SegmentationSource quoteAdvMIM │ 85.4_{(10.1\textcolor{green}{\uparrow})} │ 2.0_{(8.7\textcolor{red}{\downarrow})} │ 89.0_{(0.6\textcolor{green}{\uparrow})} │ 1.3_{(3.1\textcolor{red}{\downarrow})} │ 66.3_{(1.0\textcolor{green}{\uparrow})} │ 22.7_{(9.9\textcolor{red}{\downarrow})} │ 74.8_{(3.4\textcolor{green}{\uparrow})} │ 15.5_{(15.7\textcolor{red}{\downarrow})} │ 79.8_{(1.9\textcolor{green}{\uparrow})} │ 22.2_{(9.9\textcolor{red}{\downarrow})} │ 81.8_{(0.7\textcolor{green}{\uparrow})} │ 19.5_{(4.9\textcolor{red}{\downarrow})} |
| 6 | Cross-ALD | 80.6% | 2023-10-01 | backbone=U-Net · labeled-data=5% · Semi-supervised segmentation with 5% labeled data (3 labeled scans and 67 unlabeled s… | Cross-adversarial local distribution regularization for semi-supervised medical image segmentationSource quoteCross-ALD (Ours) │ 80.6 │ 69.08 │ 5.96 │ 1.9 │ 1.83 │ 2.99 |
| 7 | AugPaint (+1 variant) | 77.73% | 2025-06-01 | labeled-cases=5 · AugPaint-only row; 5 labeled cases. | Inpainting is All You Need: A Diffusion-based Augmentation Method for Semi-supervised Medical Image SegmentationSource quote\multirow{4}{*}{ACDC} │ AugPaint │ 42.42 │ 44.15 │ 77.73 |
Regimesemi-supervised (65)fine-tuned (21)weakly-supervised (11)domain-generalization (11)test-time-adaptation (10)scribble-supervised (8)
Showing 21 of 21 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | FRBNet proposed | mIoU | 61.6% | fine-tuned · epochs=20K iterations · subset=15 categories; excludes truck, bus, rider, motorcycle · backbone=DeepLabV3+ with ResNet-50 | FRBNet: Revisiting Low-Light Vision through Frequency-Domain Radial Basis NetworkSource quoteL349: 94.4 │ 75.5 │ 79.7 │ 46.0 │ \uline{45.4} │ \uline{52.3} │ 64.9 │ 50.8 │ 72.2 │ 9.5 │ 84.2 │ 40.9 │ 70.4 │ 88.7 │ 49.3 │ 61.6 |
| 2024 | SAL proposed | mean Dice | 5.2% | fine-tuned · labeled-subjects=2 | Self-Supervised Alignment Learning for Medical Image SegmentationSource quoteL111: To show the effectiveness, our proposed method is compared with the existing SSL pre-training approaches, Rotation~\cite{gidaris2018unsupervised}, PIRL~\cite{misra2020self}, SimCLR~\cite{chen2020simple}, GCL~\cite{chaitanya2020contrastive}, PCL~\cite{zeng2021positional} and CCrop~\cite{peng2022crafting}. Table~\ref{tab:sota_acdc} shows the results on ACDC dataset. M refers to the number of subjects adopted in fine-tuning. In Table~\ref{tab:sota_acdc}, as M increases from 2 to 80, the mean Dice of each method continuously rises. When M is low, increasing labeled samples significantly improves the mean Dice by 14.6%-37.3%. When M is high (from 10 to 80), the great increase of samples only brings smaller improvements of 3.9%-10.3% mean Dice. The `Random' strategy is to randomly initialize model weights without any pre-training. It can be seen that when using all training samples (M=80), the mean Dice of the Random and most pre-training methods (including ours) are very close (92.7%-92.8%). It indicates that the SSL-based pre-training usually shows the effectiveness when training samples are not completely labeled. For M=2, our method outperforms the second-best PCL by 5.2% mean Dice. For M=6 and M=10, our framework surpasses the second best by 0.5%-1.9%. These results suggest that the proposed SAL framework is competitive with existing pre-training approaches. |
| 2024 | Liouna (pre-trained; downstream fine-tuning) proposed | mean Intersection over Union (mIoU) | 54.52% | fine-tuned · training-steps=10K | Liouna: Biologically Plausible Learning for Efficient Pre-Training of Transferrable Deep ModelsSource quoteL296: 54.52%, close to SimCLR’s mIoU of 55.08%. Liouna also exhibits a Mean Absolute Error (MAE) loss of 1.92 on the |
| 2024 | Proposed multitask learning (MTL; relative orientation and relative location regression) proposed | mean Dice | 0.814 | fine-tuned · subset=4 subjects · modality=SAX CMR | Self-supervised learning for medical image data with anatomy-oriented imaging planesSource quoteL462: When only four subjects are used for fine-tuning, our MTL achieves a reasonable performance of mean Dice at 0.814 and mean ASSD at 1.917 mm, which are comparable to training from scratch with 16 subjects (mean Dice at 0.815 and mean ASSD at 2.064 mm). |
| 2024 | Proposed multitask learning (MTL; relative orientation and relative location regression) proposed non-standard slice | AUC | 0.839 | split: test · fine-tuned · subset=1 subject · classifier=100-tree random forest | Self-supervised learning for medical image data with anatomy-oriented imaging planesSource quoteL495: MTL │ 0.839 │ 0.903 │ 0.959 │ 0.959 │ 0.972 |
| 2024 | SimCLR (pre-trained; downstream fine-tuning) baseline | mean Intersection over Union (mIoU) | 55.08% | fine-tuned · training-steps=10K | Liouna: Biologically Plausible Learning for Efficient Pre-Training of Transferrable Deep ModelsSource quoteL296: 54.52%, close to SimCLR’s mIoU of 55.08%. Liouna also exhibits a Mean Absolute Error (MAE) loss of 1.92 on the |
| 2024 | Training from scratch (None) baseline | mean Dice | 0.815 | fine-tuned · subset=16 subjects · modality=SAX CMR | Self-supervised learning for medical image data with anatomy-oriented imaging planesSource quoteL462: When only four subjects are used for fine-tuning, our MTL achieves a reasonable performance of mean Dice at 0.814 and mean ASSD at 1.917 mm, which are comparable to training from scratch with 16 subjects (mean Dice at 0.815 and mean ASSD at 2.064 mm). |
| 2024 | Training from scratch (None) baseline non-standard slice | AUC | 0.608 | split: test · fine-tuned · subset=1 subject · classifier=100-tree random forest | Self-supervised learning for medical image data with anatomy-oriented imaging planesSource quoteL485: None │ 0.608 │ 0.825 │ 0.861 │ 0.909 │ 0.920 |
| 2023 | DIAMANT (dual encoder; all four attention skip connections enabled) proposed | DSC | 91.90% | fine-tuned · backbone=ViT-S/16 | DIAMANT: Dual Image-Attention Map Encoders For Medical Image SegmentationSource quoteL274: 1 │ 1 │ 1 │ 1 │ 90.53 │ 89.52 │ 95.63 │ 91.90 |
| 2023 | MACL proposed | HD95 | 5.23 | fine-tuned · pretraining=CHD (CT) · labeled-data=10% | Multi-level Asymmetric Contrastive Learning for Medical Image Segmentation Pre-trainingSource quoteL456: Our proposed MACL also achieves the lowest (best) HD95, such as 5.23 on ACDC, 5.91 on MMWHS and 22.38 on HVSMR, 6.93 on Spleen and 21.53 on ISIC. |
| 2023 | full fine-tuning baseline | Dice(%) | 88.21% | fine-tuned · backbone=SegFormer-B4 · pretraining=ADE20K | DVPT: Dynamic Visual Prompt Tuning of large pre-trained models for medical image analysisSource quoteL210: full fine-tuning │ 61.6383 │ 55.77 │ 12.03 │ 91.79 │ 86.86 │ 92.88 │ 87.31 │ 74.12 │ 17.37 │ 88.21 │ 2.66 |
| 2022 | Doubly contrastive image- and pixel-level supervised method, SwiftNet (ResNet-18) proposed | mIoU | 66.24% | fine-tuned · backbone=ResNet-18 | Doubly Contrastive End-to-End Semantic Segmentation for Autonomous Driving under Adverse WeatherSource quoteL214: (g) │ +Image- and Pixel-level Supervised Contrasts (Ours)^\dag │ 66.24 │ 75.38 │ 48.82 │ 65.79 │ 68.42 |
| 2022 | SwiftNet (ResNet-18), self-supervised and pixel-level supervised contrasts ablation | mIoU | 66.97% | fine-tuned · backbone=ResNet-18 | Doubly Contrastive End-to-End Semantic Segmentation for Autonomous Driving under Adverse WeatherSource quoteL213: (f) │ +Self-supervised and Pixel-level Supervised Contrasts^\dag │ 66.97 │ 74.05 │ 49.10 │ 67.85 │ 69.69 |
| 2022 | Swin-Unet baseline | DSC | 88.07% | split: test · fine-tuned · subset=20 patients · backbone=Swin-Unet | Optimizing Vision Transformers for Medical Image SegmentationSource quoteL134: Swin-Unet │ 88.07 │ 85.77 │ 84.42 │ 94.03 |
| 2022 | Swin-Unet baseline | RV DSC | 85.77% | split: test · fine-tuned · subset=20 patients · backbone=Swin-Unet | Optimizing Vision Transformers for Medical Image SegmentationSource quoteL134: Swin-Unet │ 88.07 │ 85.77 │ 84.42 │ 94.03 |
| 2021 | MIASSR proposed | FID | 153.5 | fine-tuned · pretraining=OASIS-brain · fine-tuning-steps=10000 | MIASSR: An Approach for Medical Image Arbitrary Scale Super-ResolutionSource quoteL210: MIASSR(ours) │ 36.89 / 62.28 │ 36.86 / 61.06 │ 34.28 / 46.74 │ 35.91 / 68.45 │ 30.94 / 153.5 │ 43.21 / 37.66 |
| 2020 | Proposed deep generative model-based quality control proposed | Pearson correlation coefficient r | 0.97 | fine-tuned · n=100 · subgroups=5 · segmentation-model-training=UK Biobank; no fine-tuning | Deep Generative Model-Based Quality Control for Cardiac MRI SegmentationSource quoteL99: Quality control performance is assessed in terms of Dice metric prediction accuracy. Pearson correlation coefficient r and mean absolute error (MAE) between predicted Dice and real Dice are calculated. Table 1 compares the quantitative performance of the methods and Fig.\ref{figure3} visualises the predictions. On UK Biobank dataset, the hand-crafted feature method performed the worst. The proposed method achieved a similar performance (r=0.96, MAE=0.07) as the CNN regression method (r=0.97, MAE=0.06). However, on ACDC dataset, the proposed method (r=0.97, MAE=0.03) outperformed the CNN regression method (r=0.97, MAE=0.17) with a smaller MAE. As shown in Fig. \ref{figure3}, on ACDC dataset, the prediction of the proposed method aligns well with the identity line, whereas the CNN regression method clearly deviates from the line, even though the r coefficient is still high. |
| 2020 | Proposed deep generative model-based quality control proposed | Mean absolute error (MAE) | 0.03 | fine-tuned · n=100 · subgroups=5 · segmentation-model-training=UK Biobank; no fine-tuning | Deep Generative Model-Based Quality Control for Cardiac MRI SegmentationSource quoteL99: Quality control performance is assessed in terms of Dice metric prediction accuracy. Pearson correlation coefficient r and mean absolute error (MAE) between predicted Dice and real Dice are calculated. Table 1 compares the quantitative performance of the methods and Fig.\ref{figure3} visualises the predictions. On UK Biobank dataset, the hand-crafted feature method performed the worst. The proposed method achieved a similar performance (r=0.96, MAE=0.07) as the CNN regression method (r=0.97, MAE=0.06). However, on ACDC dataset, the proposed method (r=0.97, MAE=0.03) outperformed the CNN regression method (r=0.97, MAE=0.17) with a smaller MAE. As shown in Fig. \ref{figure3}, on ACDC dataset, the prediction of the proposed method aligns well with the identity line, whereas the CNN regression method clearly deviates from the line, even though the r coefficient is still high. |
| 2020 | G^D encoder + random-initialized decoder proposed | Mean Dice score (DSC) | 0.784 | split: test · fine-tuned · decoder=random-initialized · labeled-volumes=2 | Contrastive learning of global and local features for medical image segmentation with limited annotationsSource quoteL494: {G (D)} │ {random init} │ ACDC │ \multicolumn{3}{|l|}{0.691} │ \multicolumn{3}{|l|}{0.784} │ \multicolumn{3}{|l|}{0.870} |
| 2020 | CNN regression method (ResNet-18 backbone) baseline | Pearson correlation coefficient r | 0.97 | fine-tuned · n=100 · backbone=ResNet-18 · subgroups=5 · segmentation-model-training=UK Biobank; no fine-tuning | Deep Generative Model-Based Quality Control for Cardiac MRI SegmentationSource quoteL99: Quality control performance is assessed in terms of Dice metric prediction accuracy. Pearson correlation coefficient r and mean absolute error (MAE) between predicted Dice and real Dice are calculated. Table 1 compares the quantitative performance of the methods and Fig.\ref{figure3} visualises the predictions. On UK Biobank dataset, the hand-crafted feature method performed the worst. The proposed method achieved a similar performance (r=0.96, MAE=0.07) as the CNN regression method (r=0.97, MAE=0.06). However, on ACDC dataset, the proposed method (r=0.97, MAE=0.03) outperformed the CNN regression method (r=0.97, MAE=0.17) with a smaller MAE. As shown in Fig. \ref{figure3}, on ACDC dataset, the prediction of the proposed method aligns well with the identity line, whereas the CNN regression method clearly deviates from the line, even though the r coefficient is still high. |
| 2020 | CNN regression method (ResNet-18 backbone) baseline | Mean absolute error (MAE) | 0.17 | fine-tuned · n=100 · backbone=ResNet-18 · subgroups=5 · segmentation-model-training=UK Biobank; no fine-tuning | Deep Generative Model-Based Quality Control for Cardiac MRI SegmentationSource quoteL99: Quality control performance is assessed in terms of Dice metric prediction accuracy. Pearson correlation coefficient r and mean absolute error (MAE) between predicted Dice and real Dice are calculated. Table 1 compares the quantitative performance of the methods and Fig.\ref{figure3} visualises the predictions. On UK Biobank dataset, the hand-crafted feature method performed the worst. The proposed method achieved a similar performance (r=0.96, MAE=0.07) as the CNN regression method (r=0.97, MAE=0.06). However, on ACDC dataset, the proposed method (r=0.97, MAE=0.03) outperformed the CNN regression method (r=0.97, MAE=0.17) with a smaller MAE. As shown in Fig. \ref{figure3}, on ACDC dataset, the prediction of the proposed method aligns well with the identity line, whereas the CNN regression method clearly deviates from the line, even though the r coefficient is still high. |