ACDC

242 papers · 564 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching regime=semi-supervised.

76.881.586.290.9202220242025MC-Net+: 87.1 (2022)MC-Net+: 88.51 (2022)ACTION: 86.7 (2022)ACTION: 89.7 (2022)ACTION: 89.8 (2022)DCPA: 85.86 (2023)Cross-ALD: 80.6 (2023)AdvMIM: 85.4 (2025)TransMedSeg: 89.96 (2025)AugPaint: 42.42 (2025)AugPaint: 77.73 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 33 of 33 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025CLFSeg (17 filters) proposedDSC0.9522split: testCLFSeg: A Fuzzy-Logic based Solution for Boundary Clarity and Uncertainty Reduction in Medical Image Segmentation
Source quote
L368: In the cardiac segmentation task on the ACDC dataset, CLFSeg match the performance with baseline \cite{dumitru2023using} for 17 and 34 filters. But exceeded the performance of recent models such as Duck-Net and Adaptive t-vMF for 17 filters, reaching a DSC of 0.9522 and IoU of 0.9087 while reducing computational complexity by up to 30% as shown in Table \ref{table:CLFSeg_ACDC_Results}.
2025MedSegFactory proposedDSC88.02%split: test · trained-on-generated-data · segmentation-model=nnUNetMedSegFactory: Text-Guided Generation of Medical Image-Mask Pairs
Source quote
L261: MedSegFactory │ 88.02 │ 81.50 │ 83.38 │ 78.75 │ 90.85 │ 86.61
2025AstMatch proposedDSC (%)90.47%split: test · backbone=2D U-Net · labeled-fraction=10%AstMatch: Adversarial self-training consistency framework for semi-supervised medical image segmentation
Source quote
L1306: 90.47
2025Sim-MPNet proposedDSC92.18%split: testSimilarity Memory Prior is All You Need for Medical Image Segmentation
Source quote
L169: ACDC. ACDC datasets test the model's ability to explore local details, and ViT-based methods are often difficult to achieve better segmentation results. \Cref{table1} shows that the DSC of SwinUNet, TransDeepLab and DAE-Former does not exceed 90%. Although the hybrid CNN-ViT methods partially compensate for the shortcomings of ViT, its highest DSC is only 91.48%. In contrast, Sim-MPNet can directly capture the category features of organs in ACDC by dynamic memory prior mechanism, thus achieving 92.18% DSC and acquiring better segmentation results.
2025Mamba-UNet baselineDSC91.08%split: test · resolution=256×256 · split-ratio=70% train, 10% validation, 20% testUD-Mamba: A pixel-level uncertainty-driven Mamba model for medical image segmentation
Source quote
L209: Mamba-UNet~\cite{wang2024mamba_unet} │ 91.08 │ 90.80 │ 88.09 │ 94.35 │ 84.03 │ 1.40
2025DiffBoost baselineDSC87.29%split: test · trained-on-generated-data · segmentation-model=nnUNetMedSegFactory: Text-Guided Generation of Medical Image-Mask Pairs
Source quote
L260: DiffBoost~\cite{zhang2024diffboost} │ 87.29 │ 80.66 │ 78.11 │ 72.46 │ 89.33 │ 84.63
2025BCP [6] baselineDSC (%)88.84%split: test · backbone=2D U-Net · labeled-fraction=10%AstMatch: Adversarial self-training consistency framework for semi-supervised medical image segmentation
Source quote
L1301: 88.84
2024HResFormer (table label: Ours) proposedDSC91.88split: testHResFormer: Hybrid Residual Transformer for Volumetric Medical Image Segmentation
Source quote
L361: Ours │ 91.88 │ 90.44 │ 89.50 │ 95.79
2024CorrMLP proposedDSC0.810split: testCorrelation-aware Coarse-to-fine MLPs for Deformable Medical Image Registration
Source quote
L431: 0.810
2024SemSim proposedDSC0.872split: test · semi-supervised · labeled-data=1% (1 case)SemSim: Revisiting Weak-to-Strong Consistency from a Semantic Similarity Perspective for Semi-supervised Medical Image Segmentation
Source quote
L361: SemSim │ {\color[HTML]{FF0000}0.872} │ {\color[HTML]{FF0000}1.8} │ {\color[HTML]{FF0000}0.888} │ {\color[HTML]{FF0000}1.9} │ {\color[HTML]{FF0000}0.896} │ {\color[HTML]{FF0000}2.3} │ 2.60
2024CCT-R (mean, Affine) proposedDSC80.4%split: test · fusion=mean logits · registration=affine · labeled_cases=1 · labeled_fraction=1.4%Learning Semi-Supervised Medical Image Segmentation from Spatial Registration
Source quote
L592: Ours (mean, Affine) │ \bf{80.4} │ \bf{3.5} │ \bf{78.3} │ \bf{3.2} │ \bf{83.6} │ 4.3 │ 79.3 │ \bf{2.9}
2024Ours-ABD (BCP) proposedDSC↑89.81split: test · semi-supervisedAdaptive Bidirectional Displacement for Semi-Supervised Medical Image Segmentation
Source quote
L505: 89.81
2024DeNAS-ViT proposedDSC0.915split: test · semi-supervised-15-labeled · resolution=224×224 · labeled-data=15%DeNAS-ViT: Data Efficient NAS-Optimized Vision Transformer for Ultrasound Image Segmentation
Source quote
L380: DeNAS-ViT │ \boldsymbol{0.890} ({\textbf{\textcolor{iccvblue}{+0.059}}}) │ \boldsymbol{3.356} (\textbf{\textcolor{iccvblue}{-7.265}}) │ \boldsymbol{0.915} (\textbf{\textcolor{iccvblue}{+0.064}}) │ \boldsymbol{1.677} (\textbf{\textcolor{iccvblue}{-5.627}})
2024M-CnT proposedDSC0.753split: test · semi-supervised · labeled-data=3%Combinatorial CNN-Transformer Learning with Manifold Constraints for Semi-supervised Medical Image Segmentation
Source quote
L318: 0.753
2024nnU-NetDSC91.36split: testHResFormer: Hybrid Residual Transformer for Volumetric Medical Image Segmentation
Source quote
L359: nnU-Net~\citep{nnunet} │ 91.36 │ 90.11 │ 88.75 │ 95.23
2024BCP (CVPR’2023) baselineDSC↑88.84split: test · semi-supervisedAdaptive Bidirectional Displacement for Semi-Supervised Medical Image Segmentation
Source quote
L495: 88.84
2024CnT-B baselineDSC0.876split: test · semi-supervised-10-labeled · resolution=224×224 · labeled-data=10%DeNAS-ViT: Data Efficient NAS-Optimized Vision Transformer for Ultrasound Image Segmentation
Source quote
L376: CnT-B │ 0.876 ({\textcolor{iccvblue}{+0.045}}) │ 5.120 ({\textcolor{iccvblue}{-5.501}}) │ {0.894} ({\textcolor{iccvblue}{+0.043}}) │ {2.853} ({\textcolor{iccvblue}{-4.451}})
2023VAFA-FR (frequency-consistency adversarial training) proposed non-standard sliceDSC73.05split: test · q_max=10 · backbone=UNETR · patch_size=32×32×32 · resolution=32x32 · evaluation_attack=VAFAFrequency Domain Adversarial Training for Robust Volumetric Medical Segmentation
Source quote
L244: \multirow{-2}{*}{\rotatebox[origin=c]{90}{\parbox[c]{0.8cm}{\texttt{ACDC}}}} │ \mathcal{M}^{\Scale[0.5]{\text{VAFA-FR}}}_{_{\text{\faShield*}}} │ 83.44 │ 60.63 │ 69.33 │ 60.61 │ 73.05 │ 91.36 │ 85.42 │ 87.42 │ 83.90 │ 91.23
2023LCLPL [10] baselineDSC ↑0.881split: test · labeled-data=10%Pseudo-Label Guided Contrastive Learning for Semi-Supervised Medical Image Segmentation
Source quote
L294: 0.881
2022RoS-FL w/ DWCS proposedDSC0.8799split: test · clients=4 · local-epochs=1 · communication-rounds=300Robust Split Federated Learning for U-shaped Medical Image Networks
Source quote
L220: RoS-FL w/ DWCS │ 0.8799 │ 2.718 │ 0.8572 │ 0.7932
2022C-CAM proposedDSC80.34%split: test · weakly-supervised · supervision=image-levelC-CAM: Causal CAM for Weakly Supervised Semantic Segmentation on Medical Image
Source quote
L20: Recently, many excellent weakly supervised semantic segmentation (WSSS) works are proposed based on class activation mapping (CAM). However, there are few works that consider the characteristics of medical images. In this paper, we find that there are mainly two challenges of medical images in WSSS: i) the boundary of object foreground and background is not clear; ii) the co-occurrence phenomenon is very severe in training stage. We thus propose a Causal CAM (C-CAM) method to overcome the above challenges. Our method is motivated by two cause-effect chains including category-causality chain and anatomycausality chain. The category-causality chain represents the image content (cause) affects the category (effect). The anatomy-causality chain represents the anatomical structure (cause) affects the organ segmentation (effect). Extensive experiments were conducted on three public medical image data sets. Our C-CAM generates the best pseudo masks with the DSC of 77.26%, 80.34% and 78.15% on
2022ScaleFormer proposedDSC90.17split: testScaleFormer: Revisiting the Transformer-based Backbones from a Scale-wise Perspective for Medical Image Segmentation
Source quote
L407: 90.17
2022SL baselineDSC0.8754split: test · clients=4 · local-epochs=1 · communication-rounds=300Robust Split Federated Learning for U-shaped Medical Image Networks
Source quote
L211: SL \cite{SplitLearning} │ 0.8754 │ 3.624 │ 1.0272 │ 0.7886
2022Swin-Unet baselineDSC88.07%split: test · fine-tuned · subset=20 patients · backbone=Swin-UnetOptimizing Vision Transformers for Medical Image Segmentation
Source quote
L134: Swin-Unet │ 88.07 │ 85.77 │ 84.42 │ 94.03
2022R50 U-Net baselineDSC87.55split: testScaleFormer: Revisiting the Transformer-based Backbones from a Scale-wise Perspective for Medical Image Segmentation
Source quote
L367: 87.55
2021Ours (KL+Ent) proposedDSC86.94split: test · subset=Set-3 · supervision=3 fully labeled images plus 5× as many partially labeled imagesSegmentation with mixed supervision: Confidence maximization helps knowledge distillation
Source quote
L225: Ours (KL+Ent)* │ \bf \extension{86.94} │ \bf \extension{8.84}
2021SSCO baselineDSC77.16split: test · subset=Set-3Segmentation with mixed supervision: Confidence maximization helps knowledge distillation
Source quote
L224: \extension{SSCO \citep{Wang2020selfpaced}} * │ \extension{77.16} │ \extension{10.1}
2020Ours (KL+Ent), bottom branch proposedDSC75.92split: test · branch=bottom · subset=Set-3 · supervision=full and partialTeach Me to Segment with Mixed Supervision: Confident Students Become Masters
Source quote
L111: Ours (KL+Ent) │ \checkmark │ \checkmark │ 69.25 │ 49.93 │ \bf 75.92 │ \bf 30.12
2020Ours (KL+Ent), bottom branch proposedDSC78.77split: test · branch=bottom · subset=Set-5 · supervision=full and partialTeach Me to Segment with Mixed Supervision: Confident Students Become Masters
Source quote
L118: Ours (KL+Ent) │ \checkmark │ \checkmark │ 67.10 │ 45.28 │ \bf 78.77 │ \bf 23.29
2020Ours (KL+Ent), bottom branch proposedDSC88.07split: test · branch=bottom · subset=Set-10 · supervision=full and partialTeach Me to Segment with Mixed Supervision: Confident Students Become Masters
Source quote
L125: Ours (KL+Ent) │ \checkmark │ \checkmark │ 83.96 │ 30.71 │ \bf 88.07 │ \bf 4.37
2020Ours (KL), bottom branch ablationDSC63.98split: test · branch=bottom · subset=Set-3 · supervision=full and partialTeach Me to Segment with Mixed Supervision: Confident Students Become Masters
Source quote
L109: Ours (KL) │ \checkmark │ \checkmark │ 56.39 │ 63.27 │ 63.98 │ 67.67
2020Ours (KL), bottom branch ablationDSC72.69split: test · branch=bottom · subset=Set-5 · supervision=full and partialTeach Me to Segment with Mixed Supervision: Confident Students Become Masters
Source quote
L116: Ours (KL) │ \checkmark │ \checkmark │ 67.96 │ 44.01 │ 72.69 │ 40.75
2020Ours (KL), bottom branch ablationDSC82.21split: test · branch=bottom · subset=Set-10 · supervision=full and partialTeach Me to Segment with Mixed Supervision: Confident Students Become Masters
Source quote
L123: Ours (KL) │ \checkmark │ \checkmark │ 80.60 │ 27.19 │ 82.21 │ 33.96