ACDC

242 papers · 564 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching regime=semi-supervised.

76.881.586.290.9202220242025MC-Net+: 87.1 (2022)MC-Net+: 88.51 (2022)ACTION: 86.7 (2022)ACTION: 89.7 (2022)ACTION: 89.8 (2022)DCPA: 85.86 (2023)Cross-ALD: 80.6 (2023)AdvMIM: 85.4 (2025)TransMedSeg: 89.96 (2025)AugPaint: 42.42 (2025)AugPaint: 77.73 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 45 of 45 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026SonicNet proposedDSC92.02evaluation=5-fold-CVSONIC: Spectral Oriented Neural Invariant Convolutions
Source quote
L377: SonicNet (Ours) │ 88.55 │ 81.19 │ 92.02 │ 96.07 │ 2.59 │ 67 │ 61.37
2025CLFSeg (17 filters) proposedDSC0.9522split: testCLFSeg: A Fuzzy-Logic based Solution for Boundary Clarity and Uncertainty Reduction in Medical Image Segmentation
Source quote
L368: In the cardiac segmentation task on the ACDC dataset, CLFSeg match the performance with baseline \cite{dumitru2023using} for 17 and 34 filters. But exceeded the performance of recent models such as Duck-Net and Adaptive t-vMF for 17 filters, reaching a DSC of 0.9522 and IoU of 0.9087 while reducing computational complexity by up to 30% as shown in Table \ref{table:CLFSeg_ACDC_Results}.
2025CGS proposedDSC87.38%5% labeled dataBalancing Multi-Target Semi-Supervised Medical Image Segmentation With Collaborative Generalist and Specialists
Source quote
L467: Ours │ 87.38
2025MedSegFactory proposedDSC88.02%split: test · trained-on-generated-data · segmentation-model=nnUNetMedSegFactory: Text-Guided Generation of Medical Image-Mask Pairs
Source quote
L261: MedSegFactory │ 88.02 │ 81.50 │ 83.38 │ 78.75 │ 90.85 │ 86.61
2025AstMatch proposedDSC (%)90.47%split: test · backbone=2D U-Net · labeled-fraction=10%AstMatch: Adversarial self-training consistency framework for semi-supervised medical image segmentation
Source quote
L1306: 90.47
2025L2GNet (K_dim=512) proposedDSC91.44K_dim=512L2GNet: Optimal Local-to-Global Representation of Anatomical Structures for Generalized Medical Image Segmentation
Source quote
L265: 79.61 │ 23.89 │ \textcolor{red}{82.23} │ \textcolor{red}{14.17} │ 88.89 │ 1.86 │ \textcolor{red}{91.44} │ \textcolor{red}{1.24}
2025Sim-MPNet proposedDSC92.18%split: testSimilarity Memory Prior is All You Need for Medical Image Segmentation
Source quote
L169: ACDC. ACDC datasets test the model's ability to explore local details, and ViT-based methods are often difficult to achieve better segmentation results. \Cref{table1} shows that the DSC of SwinUNet, TransDeepLab and DAE-Former does not exceed 90%. Although the hybrid CNN-ViT methods partially compensate for the shortcomings of ViT, its highest DSC is only 91.48%. In contrast, Sim-MPNet can directly capture the category features of organs in ACDC by dynamic memory prior mechanism, thus achieving 92.18% DSC and acquiring better segmentation results.
2024HResFormer (table label: Ours) proposedDSC91.88split: testHResFormer: Hybrid Residual Transformer for Volumetric Medical Image Segmentation
Source quote
L361: Ours │ 91.88 │ 90.44 │ 89.50 │ 95.79
2024CorrMLP proposedDSC0.810split: testCorrelation-aware Coarse-to-fine MLPs for Deformable Medical Image Registration
Source quote
L431: 0.810
2024Semi-AGCL proposedDSC88.92backbone=2D U-Net · labeled-data=5% · unlabeled-data=95%Affinity-Graph-Guided Contractive Learning for Pretext-Free Medical Image Segmentation with Minimal Annotation
Source quote
L275: Semi-AGCL │ 88.92 │ 78.84 │ 1.90 │ 0.66
2024Semi-AGCL proposedDSC91.98backbone=2D U-Net · labeled-data=10% · unlabeled-data=90%Affinity-Graph-Guided Contractive Learning for Pretext-Free Medical Image Segmentation with Minimal Annotation
Source quote
L286: Semi-AGCL │ 91.98 │ 82.96 │ 3.36 │ 1.16
2024SemSim proposedDSC0.872split: test · semi-supervised · labeled-data=1% (1 case)SemSim: Revisiting Weak-to-Strong Consistency from a Semantic Similarity Perspective for Semi-supervised Medical Image Segmentation
Source quote
L361: SemSim │ {\color[HTML]{FF0000}0.872} │ {\color[HTML]{FF0000}1.8} │ {\color[HTML]{FF0000}0.888} │ {\color[HTML]{FF0000}1.9} │ {\color[HTML]{FF0000}0.896} │ {\color[HTML]{FF0000}2.3} │ 2.60
2024CCT-R (mean, Affine) proposedDSC80.4%split: test · fusion=mean logits · registration=affine · labeled_cases=1 · labeled_fraction=1.4%Learning Semi-Supervised Medical Image Segmentation from Spatial Registration
Source quote
L592: Ours (mean, Affine) │ \bf{80.4} │ \bf{3.5} │ \bf{78.3} │ \bf{3.2} │ \bf{83.6} │ 4.3 │ 79.3 │ \bf{2.9}
2024MaskSAM proposedDSC93.39%MaskSAM: Towards Auto-prompt SAM with Mask Classification for Volumetric Medical Image Segmentation
Source quote
L173: MaskSAM (Ours) │ 92.30 │ 91.37 │ 96.49 │ 93.39
2024UNet proposedDSC0.81 ppbackbone=UNetHarmonized Spatial and Spectral Learning for Robust and Generalized Medical Image Segmentation
Source quote
L175: Results on ACDC: The trends are similar to those on the Synapse dataset. UNet(ours) improves DSC by a substantial 0.81 pp and reduces HD by 0.44 pp. Interestingly, TransUNet(ours) improves DSC by a substantial 1.63 pp and reduces HD by 0.52 pp. On ACDC dataset, both UNet (ours) and TransUNet (ours) show improved performance in delineating complex multi-scale contour boundaries. The superior performance of TransUNet (ours) suggests that the multi-scale nature of cardiac structure benefits more from the middle to the global context. Fig.~\ref{qual:synap_acdc_pred} highlights that our objective helps existing networks to better model inter-class dependencies and overlapping structures delineation.
2024TransUNet proposedDSC1.63 ppbackbone=TransUNetHarmonized Spatial and Spectral Learning for Robust and Generalized Medical Image Segmentation
Source quote
L175: Results on ACDC: The trends are similar to those on the Synapse dataset. UNet(ours) improves DSC by a substantial 0.81 pp and reduces HD by 0.44 pp. Interestingly, TransUNet(ours) improves DSC by a substantial 1.63 pp and reduces HD by 0.52 pp. On ACDC dataset, both UNet (ours) and TransUNet (ours) show improved performance in delineating complex multi-scale contour boundaries. The superior performance of TransUNet (ours) suggests that the multi-scale nature of cardiac structure benefits more from the middle to the global context. Fig.~\ref{qual:synap_acdc_pred} highlights that our objective helps existing networks to better model inter-class dependencies and overlapping structures delineation.
2024NACL proposedDSC0.854backbone=UNet · training=2D slices · evaluation=3D volumesNeighbor-aware calibration of segmentation networks with penalty-based constraints
Source quote
L229: Mean │ \und{0.828} │ 3.14 │ 0.620 │ 7.30 │ 0.782 │ 4.44 │ 0.809 │ 3.30 │ 0.824 │ \und{2.81} │ 0.827 │ 2.99 │ 0.854 │ 2.55
2024AdaMix-CT proposedDSC89.19%backbone=U-Net · labeled-data=10%Adaptive Mix for Semi-Supervised Medical Image Segmentation
Source quote
L365: Specifically, AdaMix-CT achieves the best performance of 89.19% and 89.83% in terms of DSC under 10% and 20% labeled data, respectively. Concerning the boundary-sensitive metrics 95HD and ASD, with the help of AdaMix, AdaMix-CT obtains the best values of 2.46 and 0.74 for the 10% labeled data.
2024AdaMix-CT proposedDSC89.83%backbone=U-Net · labeled-data=20%Adaptive Mix for Semi-Supervised Medical Image Segmentation
Source quote
L365: Specifically, AdaMix-CT achieves the best performance of 89.19% and 89.83% in terms of DSC under 10% and 20% labeled data, respectively. Concerning the boundary-sensitive metrics 95HD and ASD, with the help of AdaMix, AdaMix-CT obtains the best values of 2.46 and 0.74 for the 10% labeled data.
2024CPC-SAM proposedDSC85.56%semi-supervised · labeled-data=1/70Cross Prompting Consistency with Segment Anything Model for Semi-supervised Medical Image Segmentation
Source quote
L153: CPC-SAM (ours) │ {10/431} │ {71.20} │ {61.15} │ {100.22} │ 37.86 │ {1/70} │ {85.56} │ {75.74} │ {9.19} │ 2.84
2024Ours-ABD (BCP) proposedDSC↑89.81split: test · semi-supervisedAdaptive Bidirectional Displacement for Semi-Supervised Medical Image Segmentation
Source quote
L505: 89.81
2024DeNAS-ViT proposedDSC0.915split: test · semi-supervised-15-labeled · resolution=224×224 · labeled-data=15%DeNAS-ViT: Data Efficient NAS-Optimized Vision Transformer for Ultrasound Image Segmentation
Source quote
L380: DeNAS-ViT │ \boldsymbol{0.890} ({\textbf{\textcolor{iccvblue}{+0.059}}}) │ \boldsymbol{3.356} (\textbf{\textcolor{iccvblue}{-7.265}}) │ \boldsymbol{0.915} (\textbf{\textcolor{iccvblue}{+0.064}}) │ \boldsymbol{1.677} (\textbf{\textcolor{iccvblue}{-5.627}})
2024CRaC (UNet) proposedDSC0.877backbone=UNet · training=2D slices · evaluation=3D volumesClass and Region-Adaptive Constraints for Network Calibration
Source quote
L169: CRaC\xspace (Ours) │ 0.877 │ 1.72 │ 0.057 │ 0.058 │ 0.876 │ 5.52 │ 0.029 │ 0.033 │ 1.75 │ 1
2024DINOv2 + SAM 2 retrieval-augmented few-shot segmentation framework proposedDSC0.6729few-shot · class=right-ventricleRetrieval-Augmented Few-Shot Medical Image Segmentation With Foundation Models
Source quote
L107: In this subsection, we present a comparative analysis of our model and the SAM 2 model using different point prompts. Table \Cref{tab:tab1} demonstrate the segmentation performance across three datasets: ACDC, CMR T1-MAP, and Fluoroscopy Image, evaluated using the Dice similarity coefficient (DSC). Our approach consistently outperforms the SAM 2 model across all datasets and point prompt configurations. For the ACDC dataset, our method achieves DSC scores of 0.6729, 0.7757, and 0.8472 for the right ventricle (RV), myocardium (Myo), and left ventricle (LV), respectively, demonstrating a remarkble improvement, particularly in the Myo and LV classes. In the CMR T1-MAP and Fluoroscopy Image datasets, our model also shows superior performance with DSC scores of 0.8238 and 0.8431, respectively. This consistent improvements in segmentation accuracy suggest the robustness and effectiveness of our method for few-shot medical image segmentation, especially in cases where the SAM 2 model with prompts falls short.
2024DINOv2 + SAM 2 retrieval-augmented few-shot segmentation framework proposedDSC0.7757few-shot · class=myocardiumRetrieval-Augmented Few-Shot Medical Image Segmentation With Foundation Models
Source quote
L107: In this subsection, we present a comparative analysis of our model and the SAM 2 model using different point prompts. Table \Cref{tab:tab1} demonstrate the segmentation performance across three datasets: ACDC, CMR T1-MAP, and Fluoroscopy Image, evaluated using the Dice similarity coefficient (DSC). Our approach consistently outperforms the SAM 2 model across all datasets and point prompt configurations. For the ACDC dataset, our method achieves DSC scores of 0.6729, 0.7757, and 0.8472 for the right ventricle (RV), myocardium (Myo), and left ventricle (LV), respectively, demonstrating a remarkble improvement, particularly in the Myo and LV classes. In the CMR T1-MAP and Fluoroscopy Image datasets, our model also shows superior performance with DSC scores of 0.8238 and 0.8431, respectively. This consistent improvements in segmentation accuracy suggest the robustness and effectiveness of our method for few-shot medical image segmentation, especially in cases where the SAM 2 model with prompts falls short.
2024DINOv2 + SAM 2 retrieval-augmented few-shot segmentation framework proposedDSC0.8472few-shot · class=left-ventricleRetrieval-Augmented Few-Shot Medical Image Segmentation With Foundation Models
Source quote
L107: In this subsection, we present a comparative analysis of our model and the SAM 2 model using different point prompts. Table \Cref{tab:tab1} demonstrate the segmentation performance across three datasets: ACDC, CMR T1-MAP, and Fluoroscopy Image, evaluated using the Dice similarity coefficient (DSC). Our approach consistently outperforms the SAM 2 model across all datasets and point prompt configurations. For the ACDC dataset, our method achieves DSC scores of 0.6729, 0.7757, and 0.8472 for the right ventricle (RV), myocardium (Myo), and left ventricle (LV), respectively, demonstrating a remarkble improvement, particularly in the Myo and LV classes. In the CMR T1-MAP and Fluoroscopy Image datasets, our model also shows superior performance with DSC scores of 0.8238 and 0.8431, respectively. This consistent improvements in segmentation accuracy suggest the robustness and effectiveness of our method for few-shot medical image segmentation, especially in cases where the SAM 2 model with prompts falls short.
2024M-CnT proposedDSC0.753split: test · semi-supervised · labeled-data=3%Combinatorial CNN-Transformer Learning with Manifold Constraints for Semi-supervised Medical Image Segmentation
Source quote
L318: 0.753
2023DIAMANT (dual encoder; all four attention skip connections enabled) proposedDSC91.90%fine-tuned · backbone=ViT-S/16DIAMANT: Dual Image-Attention Map Encoders For Medical Image Segmentation
Source quote
L274: 1 │ 1 │ 1 │ 1 │ 90.53 │ 89.52 │ 95.63 │ 91.90
2023MTCauSSL proposedDSC82.89%MT with CauSSL; 7/70 labeled cases.CauSSL: Causality-inspired Semi-supervised Learning for Medical Image Segmentation
Source quote
L520: 82.89%
2023MCSC (Multi-Scale Cross Supervised Contrastive Learning) proposedDSC89.4%semi-supervised · labeled-cases=7 · labeled-fraction=10%Multi-Scale Cross Contrastive Learning for Semi-Supervised Medical Image Segmentation
Source quote
L165: More importantly, it achieves 2.3mm HD, significantly better than even the fully supervised U-Net and BATFormer, which achieve 4.0 and 8.0 respectively. It also demonstrates competitive DSC of 89.4 %, compared with 91.7 % and 92.8 % of U-Net and BATFormer.
2023MCSC (Multi-Scale Cross Supervised Contrastive Learning) proposedDSC73.6%semi-supervised · labeled-cases=3 · labeled-fraction=5%Multi-Scale Cross Contrastive Learning for Semi-Supervised Medical Image Segmentation
Source quote
L191: MCSC (Ours) │ {\bf 73.6 } │ {\bf 10.5 } │ {\bf70.0} │ {\bf8.8} │ {\bf 79.2} │ {\bf14.9} │ {\bf71.7} │ {\bf7.8}
2023VAFA-FR (frequency-consistency adversarial training) proposed non-standard sliceDSC73.05split: test · q_max=10 · backbone=UNETR · patch_size=32×32×32 · resolution=32x32 · evaluation_attack=VAFAFrequency Domain Adversarial Training for Robust Volumetric Medical Segmentation
Source quote
L244: \multirow{-2}{*}{\rotatebox[origin=c]{90}{\parbox[c]{0.8cm}{\texttt{ACDC}}}} │ \mathcal{M}^{\Scale[0.5]{\text{VAFA-FR}}}_{_{\text{\faShield*}}} │ 83.44 │ 60.63 │ 69.33 │ 60.61 │ 73.05 │ 91.36 │ 85.42 │ 87.42 │ 83.90 │ 91.23
2023SCP-Net proposedDSC89.69semi-supervised · labeled-scans=14 · unlabeled-scans=126Self-aware and Cross-sample Prototypical Learning for Semi-supervised Medical Image Segmentation
Source quote
L209: SCP-Net │ 14 │ 126 │ 89.26 │ 0.77 │ 87.11 │ 0.51 │ 92.70 │ 0.92 │ 89.69 │ 0.73
2022PacingPseudo proposedDSC82.9%split: val · structures=RV, MYO, LV · supervision=scribble-only · cross-validation-folds=5Non-iterative scribble-supervised learning with pacing pseudo-masks for medical image segmentation
Source quote
L513: 77.729 │ \multicolumn{1}{>{}c}{82.517} │ 88.419 │ \multicolumn{1}{>{}l}{82.904}
2022RoS-FL w/ DWCS proposedDSC0.8799split: test · clients=4 · local-epochs=1 · communication-rounds=300Robust Split Federated Learning for U-shaped Medical Image Networks
Source quote
L220: RoS-FL w/ DWCS │ 0.8799 │ 2.718 │ 0.8572 │ 0.7932
2022C-CAM proposedDSC80.34%split: test · weakly-supervised · supervision=image-levelC-CAM: Causal CAM for Weakly Supervised Semantic Segmentation on Medical Image
Source quote
L20: Recently, many excellent weakly supervised semantic segmentation (WSSS) works are proposed based on class activation mapping (CAM). However, there are few works that consider the characteristics of medical images. In this paper, we find that there are mainly two challenges of medical images in WSSS: i) the boundary of object foreground and background is not clear; ii) the co-occurrence phenomenon is very severe in training stage. We thus propose a Causal CAM (C-CAM) method to overcome the above challenges. Our method is motivated by two cause-effect chains including category-causality chain and anatomycausality chain. The category-causality chain represents the image content (cause) affects the category (effect). The anatomy-causality chain represents the anatomical structure (cause) affects the organ segmentation (effect). Extensive experiments were conducted on three public medical image data sets. Our C-CAM generates the best pseudo masks with the DSC of 77.26%, 80.34% and 78.15% on
2022ScaleFormer proposedDSC90.17split: testScaleFormer: Revisiting the Transformer-based Backbones from a Scale-wise Perspective for Medical Image Segmentation
Source quote
L407: 90.17
2021Bootstrap representation learning (Ours; slice prediction with foreground-background calibration) proposedDSC0.834semi-supervised · labeled-volumes=2Bootstrap Representation Learning for Segmentation on Medical Volumes and Sequences
Source quote
L247: Ours │ 0.834 │ 0.892 │ 0.636 │ 0.690
2021Ours (KL+Ent) proposedDSC86.94split: test · subset=Set-3 · supervision=3 fully labeled images plus 5× as many partially labeled imagesSegmentation with mixed supervision: Confidence maximization helps knowledge distillation
Source quote
L225: Ours (KL+Ent)* │ \bf \extension{86.94} │ \bf \extension{8.84}
2021SwinUnet proposedDSC90.00modality=MRISwin-Unet: Unet-Like Pure Transformer for Medical Image Segmentation
Source quote
L144: SwinUnet │ 90.00 │ 88.55 │ 85.62 │ 95.83
2021CoraNet (2D) proposedDSC86.67%semi-supervised · setting=2D · modality=MRI · labeled-to-unlabeled-ratio=1:4Inconsistency-Aware Uncertainty Estimation for Semi-Supervised Medical Image Segmentation
Source quote
L473: Ours │ 86.67 │ 83.21 │ 93.19 │ 10.91
2020AEP-Net proposedDSC0.8164split: val · cross-validation=3-foldCollaborative boundary-aware context encoding networks for error map prediction
Source quote
L200: 0.8164
2020Ours (KL+Ent), bottom branch proposedDSC75.92split: test · branch=bottom · subset=Set-3 · supervision=full and partialTeach Me to Segment with Mixed Supervision: Confident Students Become Masters
Source quote
L111: Ours (KL+Ent) │ \checkmark │ \checkmark │ 69.25 │ 49.93 │ \bf 75.92 │ \bf 30.12
2020Ours (KL+Ent), bottom branch proposedDSC78.77split: test · branch=bottom · subset=Set-5 · supervision=full and partialTeach Me to Segment with Mixed Supervision: Confident Students Become Masters
Source quote
L118: Ours (KL+Ent) │ \checkmark │ \checkmark │ 67.10 │ 45.28 │ \bf 78.77 │ \bf 23.29
2020Ours (KL+Ent), bottom branch proposedDSC88.07split: test · branch=bottom · subset=Set-10 · supervision=full and partialTeach Me to Segment with Mixed Supervision: Confident Students Become Masters
Source quote
L125: Ours (KL+Ent) │ \checkmark │ \checkmark │ 83.96 │ 30.71 │ \bf 88.07 │ \bf 4.37