ACDC
242 papers · 564 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching regime=semi-supervised.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | TransMedSeg SOTA frontier | 89.96% | 2025-05-01 | labeled-data=10% · 7 labeled scans (10%) and 63 unlabeled scans (90%). | TransMedSeg: A Transferable Semantic Framework for Semi-Supervised Medical Image SegmentationSource quoteTransMedSeg │ 88.14 │ 79.48 │ 3.42 │ 0.97 │ 89.96 │ 82.31 │ 1.61 │ 0.64 |
| 2 | ACTION SOTA frontier (+2 variants) | 89.8% | 2022-06-01 | labeled-cases=7 · anatomical-category=RV · 7-labeled-case setting; RV category | Bootstrapping Semi-supervised Medical Image Segmentation with Anatomical-Aware Contrastive DistillationSource quoteTable \ref{table:acdc_main} shows the evaluation results on ACDC dataset under two unlabeled settings (3 or 7 labeled cases). ACTION can substantially improve results on two unlabeled settings, greatly outperforming the previous state-of-the-art SSL methods. Specifically, our ACTION, trained on 3 labeled cases, dramatically improves the previous best averaged Dice score from 73.6% to 87.5% by a large margin, and even matches previous SSL methods using 7 labeled cases. When using 7 labeled cases, ACTION further pushes the state-of-the-art results to 89.7% in Dice. We observe that the gains are more pronounced on the two categories(i.e., RV and Myo), and our ACTION achieves 89.8% and 86.7% in terms of Dice, performing competitive or even better than the supervised baseline (89.2% and 86.7%). As shown in Figure \ref{fig:vis_acdc}, we can see the clear advantage of ACTION, where the boundaries of different regions are clearly sharper and more accurate such as RV and Myo regions. Table \ref{table:lits_main} also shows the evaluation results on LiTS dataset under two unlabeled settings (5% or 10% labeled cases). On both two labeled settings, ACTION significantly outperforms all the state-of-the-art methods by a significant margin. As shown in Figure \ref{fig:vis_lits}, ACTION achieves consistently sharp and accurate object boundaries compared to other SSL methods. |
| 3 | MC-Net+ SOTA frontier (+1 variant) | 88.51% | 2022-01-01 | labeled-data=20% · unlabeled-data=80% · 20% labeled and 80% unlabeled scans; average over myocardium, left ventricle, and rig… | Mutual consistency learning for semi-supervised medical image segmentationSource quoteMC-Net+ (Ours) │ 88.51 │ 80.19 │ 5.35 │ 1.54 │ 1.81 │ 2.99 |
| 4 | DCPA | 85.86% | 2023-08-01 | labeled_scans=3 (5%) · dimensionality=2D · unlabeled_scans=67 (95%) · 2D segmentation; 3 labeled scans (5%) and 67 unlabeled scans (95%); Dice averaged acr… | Dual-Decoder Consistency via Pseudo-Labels Guided Data Augmentation for Semi-Supervised Medical Image SegmentationSource quoteOurs │ 85.86 │ 76.13 │ 5.83 │ 2.03 |
| 5 | AdvMIM | 85.4% | 2025-01-01 | labeled-data=3% · 3% labeled-data partition; semi-supervised medical image segmentation. | AdvMIM: Adversarial Masked Image Modeling for Semi-supervised Medical Image SegmentationSource quoteAdvMIM │ 85.4_{(10.1\textcolor{green}{\uparrow})} │ 2.0_{(8.7\textcolor{red}{\downarrow})} │ 89.0_{(0.6\textcolor{green}{\uparrow})} │ 1.3_{(3.1\textcolor{red}{\downarrow})} │ 66.3_{(1.0\textcolor{green}{\uparrow})} │ 22.7_{(9.9\textcolor{red}{\downarrow})} │ 74.8_{(3.4\textcolor{green}{\uparrow})} │ 15.5_{(15.7\textcolor{red}{\downarrow})} │ 79.8_{(1.9\textcolor{green}{\uparrow})} │ 22.2_{(9.9\textcolor{red}{\downarrow})} │ 81.8_{(0.7\textcolor{green}{\uparrow})} │ 19.5_{(4.9\textcolor{red}{\downarrow})} |
| 6 | Cross-ALD | 80.6% | 2023-10-01 | backbone=U-Net · labeled-data=5% · Semi-supervised segmentation with 5% labeled data (3 labeled scans and 67 unlabeled s… | Cross-adversarial local distribution regularization for semi-supervised medical image segmentationSource quoteCross-ALD (Ours) │ 80.6 │ 69.08 │ 5.96 │ 1.9 │ 1.83 │ 2.99 |
| 7 | AugPaint (+1 variant) | 77.73% | 2025-06-01 | labeled-cases=5 · AugPaint-only row; 5 labeled cases. | Inpainting is All You Need: A Diffusion-based Augmentation Method for Semi-supervised Medical Image SegmentationSource quote\multirow{4}{*}{ACDC} │ AugPaint │ 42.42 │ 44.15 │ 77.73 |
Regimesemi-supervised (65)fine-tuned (21)weakly-supervised (11)domain-generalization (11)test-time-adaptation (10)scribble-supervised (8)
Showing 1 of 1 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2022 | C-CAM proposed | DSC | 80.34% | split: test · weakly-supervised · supervision=image-level | C-CAM: Causal CAM for Weakly Supervised Semantic Segmentation on Medical ImageSource quoteL20: Recently, many excellent weakly supervised semantic segmentation (WSSS) works are proposed based on class activation mapping (CAM). However, there are few works that consider the characteristics of medical images. In this paper, we find that there are mainly two challenges of medical images in WSSS: i) the boundary of object foreground and background is not clear; ii) the co-occurrence phenomenon is very severe in training stage. We thus propose a Causal CAM (C-CAM) method to overcome the above challenges. Our method is motivated by two cause-effect chains including category-causality chain and anatomycausality chain. The category-causality chain represents the image content (cause) affects the category (effect). The anatomy-causality chain represents the anatomical structure (cause) affects the organ segmentation (effect). Extensive experiments were conducted on three public medical image data sets. Our C-CAM generates the best pseudo masks with the DSC of 77.26%, 80.34% and 78.15% on |