ACDC

242 papers · 564 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching regime=semi-supervised.

76.881.586.290.9202220242025MC-Net+: 87.1 (2022)MC-Net+: 88.51 (2022)ACTION: 86.7 (2022)ACTION: 89.7 (2022)ACTION: 89.8 (2022)DCPA: 85.86 (2023)Cross-ALD: 80.6 (2023)AdvMIM: 85.4 (2025)TransMedSeg: 89.96 (2025)AugPaint: 42.42 (2025)AugPaint: 77.73 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 13 of 13 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2024SemSim proposedDSC0.872split: test · semi-supervised · labeled-data=1% (1 case)SemSim: Revisiting Weak-to-Strong Consistency from a Semantic Similarity Perspective for Semi-supervised Medical Image Segmentation
Source quote
L361: SemSim │ {\color[HTML]{FF0000}0.872} │ {\color[HTML]{FF0000}1.8} │ {\color[HTML]{FF0000}0.888} │ {\color[HTML]{FF0000}1.9} │ {\color[HTML]{FF0000}0.896} │ {\color[HTML]{FF0000}2.3} │ 2.60
2024CPC-SAM proposedDSC85.56%semi-supervised · labeled-data=1/70Cross Prompting Consistency with Segment Anything Model for Semi-supervised Medical Image Segmentation
Source quote
L153: CPC-SAM (ours) │ {10/431} │ {71.20} │ {61.15} │ {100.22} │ 37.86 │ {1/70} │ {85.56} │ {75.74} │ {9.19} │ 2.84
2024Ours-ABD (BCP) proposedDSC↑89.81split: test · semi-supervisedAdaptive Bidirectional Displacement for Semi-Supervised Medical Image Segmentation
Source quote
L505: 89.81
2024M-CnT proposedDSC0.753split: test · semi-supervised · labeled-data=3%Combinatorial CNN-Transformer Learning with Manifold Constraints for Semi-supervised Medical Image Segmentation
Source quote
L318: 0.753
2024UniMatch baselineDSC84.47%semi-supervised · labeled-data=1/70Cross Prompting Consistency with Segment Anything Model for Semi-supervised Medical Image Segmentation
Source quote
L151: UniMatch(CVPR’23)~\cite{yang2023revisiting} │ {10/431} │ {60.98} │ {49.85} │ {109.79} │ 47.50 │ {1/70} │ {84.47} │ {74.25} │ {15.36} │ 4.57
2024BCP (CVPR’2023) baselineDSC↑88.84split: test · semi-supervisedAdaptive Bidirectional Displacement for Semi-Supervised Medical Image Segmentation
Source quote
L495: 88.84
2023MCSC (Multi-Scale Cross Supervised Contrastive Learning) proposedDSC89.4%semi-supervised · labeled-cases=7 · labeled-fraction=10%Multi-Scale Cross Contrastive Learning for Semi-Supervised Medical Image Segmentation
Source quote
L165: More importantly, it achieves 2.3mm HD, significantly better than even the fully supervised U-Net and BATFormer, which achieve 4.0 and 8.0 respectively. It also demonstrates competitive DSC of 89.4 %, compared with 91.7 % and 92.8 % of U-Net and BATFormer.
2023MCSC (Multi-Scale Cross Supervised Contrastive Learning) proposedDSC73.6%semi-supervised · labeled-cases=3 · labeled-fraction=5%Multi-Scale Cross Contrastive Learning for Semi-Supervised Medical Image Segmentation
Source quote
L191: MCSC (Ours) │ {\bf 73.6 } │ {\bf 10.5 } │ {\bf70.0} │ {\bf8.8} │ {\bf 79.2} │ {\bf14.9} │ {\bf71.7} │ {\bf7.8}
2023SCP-Net proposedDSC89.69semi-supervised · labeled-scans=14 · unlabeled-scans=126Self-aware and Cross-sample Prototypical Learning for Semi-supervised Medical Image Segmentation
Source quote
L209: SCP-Net │ 14 │ 126 │ 89.26 │ 0.77 │ 87.11 │ 0.51 │ 92.70 │ 0.92 │ 89.69 │ 0.73
2021Bootstrap representation learning (Ours; slice prediction with foreground-background calibration) proposedDSC0.834semi-supervised · labeled-volumes=2Bootstrap Representation Learning for Segmentation on Medical Volumes and Sequences
Source quote
L247: Ours │ 0.834 │ 0.892 │ 0.636 │ 0.690
2021CoraNet (2D) proposedDSC86.67%semi-supervised · setting=2D · modality=MRI · labeled-to-unlabeled-ratio=1:4Inconsistency-Aware Uncertainty Estimation for Semi-Supervised Medical Image Segmentation
Source quote
L473: Ours │ 86.67 │ 83.21 │ 93.19 │ 10.91
2021CGL baselineDSC0.789semi-supervised · labeled-volumes=2Bootstrap Representation Learning for Segmentation on Medical Volumes and Sequences
Source quote
L246: CGL\cite{chaitanya2020contrastive} │ 0.789 │ 0.872 │ 0.619 │ 0.684
2021UA-MT baselineDSC82.02%semi-supervised · setting=2D · modality=MRI · labeled-to-unlabeled-ratio=1:4Inconsistency-Aware Uncertainty Estimation for Semi-Supervised Medical Image Segmentation
Source quote
L472: UA-MT \cite{yu2019uncertainty} │ 82.02 │ 83.39 │ 92.21 │ 13.70