ACDC
242 papers · 564 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching regime=semi-supervised.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | TransMedSeg SOTA frontier | 89.96% | 2025-05-01 | labeled-data=10% · 7 labeled scans (10%) and 63 unlabeled scans (90%). | TransMedSeg: A Transferable Semantic Framework for Semi-Supervised Medical Image SegmentationSource quoteTransMedSeg │ 88.14 │ 79.48 │ 3.42 │ 0.97 │ 89.96 │ 82.31 │ 1.61 │ 0.64 |
| 2 | ACTION SOTA frontier (+2 variants) | 89.8% | 2022-06-01 | labeled-cases=7 · anatomical-category=RV · 7-labeled-case setting; RV category | Bootstrapping Semi-supervised Medical Image Segmentation with Anatomical-Aware Contrastive DistillationSource quoteTable \ref{table:acdc_main} shows the evaluation results on ACDC dataset under two unlabeled settings (3 or 7 labeled cases). ACTION can substantially improve results on two unlabeled settings, greatly outperforming the previous state-of-the-art SSL methods. Specifically, our ACTION, trained on 3 labeled cases, dramatically improves the previous best averaged Dice score from 73.6% to 87.5% by a large margin, and even matches previous SSL methods using 7 labeled cases. When using 7 labeled cases, ACTION further pushes the state-of-the-art results to 89.7% in Dice. We observe that the gains are more pronounced on the two categories(i.e., RV and Myo), and our ACTION achieves 89.8% and 86.7% in terms of Dice, performing competitive or even better than the supervised baseline (89.2% and 86.7%). As shown in Figure \ref{fig:vis_acdc}, we can see the clear advantage of ACTION, where the boundaries of different regions are clearly sharper and more accurate such as RV and Myo regions. Table \ref{table:lits_main} also shows the evaluation results on LiTS dataset under two unlabeled settings (5% or 10% labeled cases). On both two labeled settings, ACTION significantly outperforms all the state-of-the-art methods by a significant margin. As shown in Figure \ref{fig:vis_lits}, ACTION achieves consistently sharp and accurate object boundaries compared to other SSL methods. |
| 3 | MC-Net+ SOTA frontier (+1 variant) | 88.51% | 2022-01-01 | labeled-data=20% · unlabeled-data=80% · 20% labeled and 80% unlabeled scans; average over myocardium, left ventricle, and rig… | Mutual consistency learning for semi-supervised medical image segmentationSource quoteMC-Net+ (Ours) │ 88.51 │ 80.19 │ 5.35 │ 1.54 │ 1.81 │ 2.99 |
| 4 | DCPA | 85.86% | 2023-08-01 | labeled_scans=3 (5%) · dimensionality=2D · unlabeled_scans=67 (95%) · 2D segmentation; 3 labeled scans (5%) and 67 unlabeled scans (95%); Dice averaged acr… | Dual-Decoder Consistency via Pseudo-Labels Guided Data Augmentation for Semi-Supervised Medical Image SegmentationSource quoteOurs │ 85.86 │ 76.13 │ 5.83 │ 2.03 |
| 5 | AdvMIM | 85.4% | 2025-01-01 | labeled-data=3% · 3% labeled-data partition; semi-supervised medical image segmentation. | AdvMIM: Adversarial Masked Image Modeling for Semi-supervised Medical Image SegmentationSource quoteAdvMIM │ 85.4_{(10.1\textcolor{green}{\uparrow})} │ 2.0_{(8.7\textcolor{red}{\downarrow})} │ 89.0_{(0.6\textcolor{green}{\uparrow})} │ 1.3_{(3.1\textcolor{red}{\downarrow})} │ 66.3_{(1.0\textcolor{green}{\uparrow})} │ 22.7_{(9.9\textcolor{red}{\downarrow})} │ 74.8_{(3.4\textcolor{green}{\uparrow})} │ 15.5_{(15.7\textcolor{red}{\downarrow})} │ 79.8_{(1.9\textcolor{green}{\uparrow})} │ 22.2_{(9.9\textcolor{red}{\downarrow})} │ 81.8_{(0.7\textcolor{green}{\uparrow})} │ 19.5_{(4.9\textcolor{red}{\downarrow})} |
| 6 | Cross-ALD | 80.6% | 2023-10-01 | backbone=U-Net · labeled-data=5% · Semi-supervised segmentation with 5% labeled data (3 labeled scans and 67 unlabeled s… | Cross-adversarial local distribution regularization for semi-supervised medical image segmentationSource quoteCross-ALD (Ours) │ 80.6 │ 69.08 │ 5.96 │ 1.9 │ 1.83 │ 2.99 |
| 7 | AugPaint (+1 variant) | 77.73% | 2025-06-01 | labeled-cases=5 · AugPaint-only row; 5 labeled cases. | Inpainting is All You Need: A Diffusion-based Augmentation Method for Semi-supervised Medical Image SegmentationSource quote\multirow{4}{*}{ACDC} │ AugPaint │ 42.42 │ 44.15 │ 77.73 |
Regimesemi-supervised (65)fine-tuned (21)weakly-supervised (11)domain-generalization (11)test-time-adaptation (10)scribble-supervised (8)
Showing 29 of 29 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | ICTC proposed | Dice | 88.22 | semi-supervised · labeled-cases=7 (10%) · unlabeled-cases=63 | An Intra- and Cross-frame Topological Consistency Scheme for Semi-supervised Atherosclerotic Coronary Plaque SegmentationSource quoteL182: ICTC(Ours) │ 7(10%) │ 63 │ 88.22 │ 78.72 │ 7.48 │ 1.58 |
| 2025 | TransMedSeg proposed | Dice | 89.96% | semi-supervised · labeled-data=10% | TransMedSeg: A Transferable Semantic Framework for Semi-Supervised Medical Image SegmentationSource quoteL168: TransMedSeg │ 88.14 │ 79.48 │ 3.42 │ 0.97 │ 89.96 │ 82.31 │ 1.61 │ 0.64 |
| 2025 | AugPaint proposed | Dice | 42.42% | semi-supervised · labeled-cases=1 | Inpainting is All You Need: A Diffusion-based Augmentation Method for Semi-supervised Medical Image SegmentationSource quoteL286: \multirow{4}{*}{ACDC} │ AugPaint │ 42.42 │ 44.15 │ 77.73 |
| 2025 | AugPaint proposed | Dice | 77.73% | semi-supervised · labeled-cases=5 | Inpainting is All You Need: A Diffusion-based Augmentation Method for Semi-supervised Medical Image SegmentationSource quoteL286: \multirow{4}{*}{ACDC} │ AugPaint │ 42.42 │ 44.15 │ 77.73 |
| 2025 | AdvMIM proposed | Dice | 85.4% | semi-supervised · labeled-data=3% | AdvMIM: Adversarial Masked Image Modeling for Semi-supervised Medical Image SegmentationSource quoteL134: AdvMIM │ 85.4_{(10.1\textcolor{green}{\uparrow})} │ 2.0_{(8.7\textcolor{red}{\downarrow})} │ 89.0_{(0.6\textcolor{green}{\uparrow})} │ 1.3_{(3.1\textcolor{red}{\downarrow})} │ 66.3_{(1.0\textcolor{green}{\uparrow})} │ 22.7_{(9.9\textcolor{red}{\downarrow})} │ 74.8_{(3.4\textcolor{green}{\uparrow})} │ 15.5_{(15.7\textcolor{red}{\downarrow})} │ 79.8_{(1.9\textcolor{green}{\uparrow})} │ 22.2_{(9.9\textcolor{red}{\downarrow})} │ 81.8_{(0.7\textcolor{green}{\uparrow})} │ 19.5_{(4.9\textcolor{red}{\downarrow})} |
| 2025 | Ours (switching Dual-Student framework with LA-EMA) proposed | Dice | 90.67 | semi-supervised · labeled-data=7/70 patients | Adaptive Knowledge Transferring with Switching Dual-Student Framework for Semi-Supervised Medical Image SegmentationSource quoteL429: 90.67 83.41 |
| 2025 | Multi-Prototype-based Embedding Refinement proposed | Dice | 88.64 | semi-supervised · labeled-cases=3 (5%) · unlabeled-cases=67 (95%) | Multi-Prototype-based Embedding Refinement for Medical Image SegmentationSource quoteL168: Ours │ 88.64 │ 80.21 │ 1.51 │ 0.60 |
| 2025 | Multi-Prototype-based Embedding Refinement proposed | Dice | 89.69 | semi-supervised · labeled-cases=7 (10%) · unlabeled-cases=63 (90%) | Multi-Prototype-based Embedding Refinement for Medical Image SegmentationSource quoteL177: Ours │ 89.69 │ 81.88 │ 1.65 │ 0.56 |
| 2025 | BCP (Reproduced) + LA-EMA ablation | Dice | 89.84 | semi-supervised · method=reproduced BCP + LA-EMA · labeled-data=7/70 patients | Adaptive Knowledge Transferring with Switching Dual-Student Framework for Semi-Supervised Medical Image SegmentationSource quoteL473: 89.84 |
| 2025 | MCNet+ baseline | Dice | 87.10 | semi-supervised · labeled-cases=7 (10%) · unlabeled-cases=63 | An Intra- and Cross-frame Topological Consistency Scheme for Semi-supervised Atherosclerotic Coronary Plaque SegmentationSource quoteL180: MCNet+ \cite{MC} │ 7(10%) │ 63 │ 87.10 │ 78.06 │ 6.68 │ 2.00 |
| 2025 | M-CnT baseline | Dice | 75.3% | semi-supervised · labeled-data=3% | AdvMIM: Adversarial Masked Image Modeling for Semi-supervised Medical Image SegmentationSource quoteL132: M-CnT~\cite{huang2024combinatorial} │ 75.3 │ 10.7 │ 88.4 │ 4.4 │ 65.3 │ 32.6 │ 71.4 │ 31.2 │ 77.9 │ 32.1 │ 81.1 │ 24.4 |
| 2025 | BCP (Reproduced) baseline | Dice | 89.25 | semi-supervised · method=reproduced BCP · labeled-data=7/70 patients | Adaptive Knowledge Transferring with Switching Dual-Student Framework for Semi-Supervised Medical Image SegmentationSource quoteL470: 89.25 |
| 2025 | BCP baseline | Dice | 87.59 | semi-supervised · labeled-cases=3 (5%) · unlabeled-cases=67 (95%) | Multi-Prototype-based Embedding Refinement for Medical Image SegmentationSource quoteL167: BCP \cite{ref27} │ 87.59 │ 78.67 │ 1.90 │ 0.67 |
| 2025 | BCP baseline | Dice | 88.84 | semi-supervised · labeled-cases=7 (10%) · unlabeled-cases=63 (90%) | Multi-Prototype-based Embedding Refinement for Medical Image SegmentationSource quoteL176: BCP \cite{ref27} │ 88.84 │ 80.62 │ 3.98 │ 1.17 |
| 2024 | DiffRect baseline | DICE↑ | 90.18 | semi-supervised · labeled-cases=7 · labeled-fraction=10% | Mind the Context: Attention-Guided Weak-to-Strong Consistency for Enhanced Semi-Supervised Medical Image SegmentationSource quoteL186: DiffRect~\cite{liu2024diffrect} │ MICCAI’24 │ 82.40 │ 71.96 │ 10.04 │ 2.90 │ 86.95 │ 78.08 │ 4.07 │ 1.23 │ 90.18 │ 82.12 │ 1.38 │ 0.48 |
| 2024 | BCP baseline | DICE↑ | 88.84 | semi-supervised · labeled-cases=7 · labeled-fraction=10% | Mind the Context: Attention-Guided Weak-to-Strong Consistency for Enhanced Semi-Supervised Medical Image SegmentationSource quoteL173: BCP~\cite{bai2023bidirectional} │ CVPR’23 │ -- │ -- │ -- │ -- │ 87.59 │ 78.67 │ 1.90 │ 0.67 │ 88.84 │ 80.62 │ 3.98 │ 1.17 |
| 2024 | DiffRect baseline | DICE↑ | 86.95 | semi-supervised · labeled-cases=3 · labeled-fraction=5% | Mind the Context: Attention-Guided Weak-to-Strong Consistency for Enhanced Semi-Supervised Medical Image SegmentationSource quoteL186: DiffRect~\cite{liu2024diffrect} │ MICCAI’24 │ 82.40 │ 71.96 │ 10.04 │ 2.90 │ 86.95 │ 78.08 │ 4.07 │ 1.23 │ 90.18 │ 82.12 │ 1.38 │ 0.48 |
| 2023 | DCPA proposed | Dice | 85.86% | semi-supervised · labeled_scans=3 (5%) · dimensionality=2D · unlabeled_scans=67 (95%) | Dual-Decoder Consistency via Pseudo-Labels Guided Data Augmentation for Semi-Supervised Medical Image SegmentationSource quoteL288: Ours │ 85.86 │ 76.13 │ 5.83 │ 2.03 |
| 2023 | BCP (α=0.5) proposed | Dice | 87.59 | semi-supervised · alpha=0.5 · input=2D slices · classes=four-class average · labeled-data=5% (3 scans) · unlabeled-data=95% (67 scans) | Bidirectional Copy-Paste for Semi-Supervised Medical Image SegmentationSource quoteL342: 88.02 │ 78.72 │ 7.90 │ 2.15 │ \multirow{4}{*}{3(5%)} │ \multicolumn{1}{c|}{\multirow{4}{*}{67(95%)}} │ 87.59 │ 78.67 │ 1.90 │ 0.67 |
| 2023 | Cross-ALD proposed | Dice (%) | 80.6% | semi-supervised · backbone=U-Net · labeled-data=5% | Cross-adversarial local distribution regularization for semi-supervised medical image segmentationSource quoteL142: Cross-ALD (Ours) │ 80.6 │ 69.08 │ 5.96 │ 1.9 │ 1.83 │ 2.99 |
| 2023 | SS-Net baseline | Dice | 65.82% | semi-supervised · labeled_scans=3 (5%) · dimensionality=2D · unlabeled_scans=67 (95%) | Dual-Decoder Consistency via Pseudo-Labels Guided Data Augmentation for Semi-Supervised Medical Image SegmentationSource quoteL286: SS-Net (MICCAI'22) │ 65.82 │ 55.38 │ 6.67 │ 2.28 |
| 2023 | SS-Net baseline | Dice (%) | 65.82% | semi-supervised · backbone=U-Net · labeled-data=5% | Cross-adversarial local distribution regularization for semi-supervised medical image segmentationSource quoteL141: SS-Net \cite{wu2022exploring} │ 65.82 │ 55.38 │ 6.67 │ 2.28 │ 1.83 │ 2.99 |
| 2022 | ACTION proposed | Dice | 89.7% | semi-supervised · labeled-cases=7 | Bootstrapping Semi-supervised Medical Image Segmentation with Anatomical-Aware Contrastive DistillationSource quoteL384: Table \ref{table:acdc_main} shows the evaluation results on ACDC dataset under two unlabeled settings (3 or 7 labeled cases). ACTION can substantially improve results on two unlabeled settings, greatly outperforming the previous state-of-the-art SSL methods. Specifically, our ACTION, trained on 3 labeled cases, dramatically improves the previous best averaged Dice score from 73.6% to 87.5% by a large margin, and even matches previous SSL methods using 7 labeled cases. When using 7 labeled cases, ACTION further pushes the state-of-the-art results to 89.7% in Dice. We observe that the gains are more pronounced on the two categories(i.e., RV and Myo), and our ACTION achieves 89.8% and 86.7% in terms of Dice, performing competitive or even better than the supervised baseline (89.2% and 86.7%). As shown in Figure \ref{fig:vis_acdc}, we can see the clear advantage of ACTION, where the boundaries of different regions are clearly sharper and more accurate such as RV and Myo regions. Table \ref{table:lits_main} also shows the evaluation results on LiTS dataset under two unlabeled settings (5% or 10% labeled cases). On both two labeled settings, ACTION significantly outperforms all the state-of-the-art methods by a significant margin. As shown in Figure \ref{fig:vis_lits}, ACTION achieves consistently sharp and accurate object boundaries compared to other SSL methods. |
| 2022 | ACTION proposed | Dice | 89.8% | semi-supervised · labeled-cases=7 · anatomical-category=RV | Bootstrapping Semi-supervised Medical Image Segmentation with Anatomical-Aware Contrastive DistillationSource quoteL384: Table \ref{table:acdc_main} shows the evaluation results on ACDC dataset under two unlabeled settings (3 or 7 labeled cases). ACTION can substantially improve results on two unlabeled settings, greatly outperforming the previous state-of-the-art SSL methods. Specifically, our ACTION, trained on 3 labeled cases, dramatically improves the previous best averaged Dice score from 73.6% to 87.5% by a large margin, and even matches previous SSL methods using 7 labeled cases. When using 7 labeled cases, ACTION further pushes the state-of-the-art results to 89.7% in Dice. We observe that the gains are more pronounced on the two categories(i.e., RV and Myo), and our ACTION achieves 89.8% and 86.7% in terms of Dice, performing competitive or even better than the supervised baseline (89.2% and 86.7%). As shown in Figure \ref{fig:vis_acdc}, we can see the clear advantage of ACTION, where the boundaries of different regions are clearly sharper and more accurate such as RV and Myo regions. Table \ref{table:lits_main} also shows the evaluation results on LiTS dataset under two unlabeled settings (5% or 10% labeled cases). On both two labeled settings, ACTION significantly outperforms all the state-of-the-art methods by a significant margin. As shown in Figure \ref{fig:vis_lits}, ACTION achieves consistently sharp and accurate object boundaries compared to other SSL methods. |
| 2022 | ACTION proposed | Dice | 86.7% | semi-supervised · labeled-cases=7 · anatomical-category=Myo | Bootstrapping Semi-supervised Medical Image Segmentation with Anatomical-Aware Contrastive DistillationSource quoteL384: Table \ref{table:acdc_main} shows the evaluation results on ACDC dataset under two unlabeled settings (3 or 7 labeled cases). ACTION can substantially improve results on two unlabeled settings, greatly outperforming the previous state-of-the-art SSL methods. Specifically, our ACTION, trained on 3 labeled cases, dramatically improves the previous best averaged Dice score from 73.6% to 87.5% by a large margin, and even matches previous SSL methods using 7 labeled cases. When using 7 labeled cases, ACTION further pushes the state-of-the-art results to 89.7% in Dice. We observe that the gains are more pronounced on the two categories(i.e., RV and Myo), and our ACTION achieves 89.8% and 86.7% in terms of Dice, performing competitive or even better than the supervised baseline (89.2% and 86.7%). As shown in Figure \ref{fig:vis_acdc}, we can see the clear advantage of ACTION, where the boundaries of different regions are clearly sharper and more accurate such as RV and Myo regions. Table \ref{table:lits_main} also shows the evaluation results on LiTS dataset under two unlabeled settings (5% or 10% labeled cases). On both two labeled settings, ACTION significantly outperforms all the state-of-the-art methods by a significant margin. As shown in Figure \ref{fig:vis_lits}, ACTION achieves consistently sharp and accurate object boundaries compared to other SSL methods. |
| 2021 | MC-Net+ proposed | Dice | 87.10% | semi-supervised · labeled-data=10% · unlabeled-data=90% | Mutual consistency learning for semi-supervised medical image segmentationSource quoteL242: MC-Net+ (Ours) │ 87.10 │ 78.06 │ 6.68 │ 2.00 │ 1.81 │ 2.99 |
| 2021 | MC-Net+ proposed | Dice | 88.51% | semi-supervised · labeled-data=20% · unlabeled-data=80% | Mutual consistency learning for semi-supervised medical image segmentationSource quoteL249: MC-Net+ (Ours) │ 88.51 │ 80.19 │ 5.35 │ 1.54 │ 1.81 │ 2.99 |
| 2021 | MC-Net baseline | Dice | 86.34% | semi-supervised · labeled-data=10% · unlabeled-data=90% | Mutual consistency learning for semi-supervised medical image segmentationSource quoteL241: MC-Net \citep{mcnet} (MICCAI) │ 86.34 │ 76.82 │ 7.08 │ 2.08 │ 2.58 │ 5.39 |
| 2021 | MC-Net baseline | Dice | 87.83% | semi-supervised · labeled-data=20% · unlabeled-data=80% | Mutual consistency learning for semi-supervised medical image segmentationSource quoteL248: MC-Net \citep{mcnet} (MICCAI) │ 87.83 │ 79.14 │ 4.94 │ 1.52 │ 2.58 │ 5.39 |