| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | TransMedSeg SOTA frontier | 89.96% | 2025-05-01 | labeled-data=10% · 7 labeled scans (10%) and 63 unlabeled scans (90%). | TransMedSeg: A Transferable Semantic Framework for Semi-Supervised Medical Image SegmentationSource quoteTransMedSeg │ 88.14 │ 79.48 │ 3.42 │ 0.97 │ 89.96 │ 82.31 │ 1.61 │ 0.64 |
| 2 | ACTION SOTA frontier (+2 variants) | 89.8% | 2022-06-01 | labeled-cases=7 · anatomical-category=RV · 7-labeled-case setting; RV category | Bootstrapping Semi-supervised Medical Image Segmentation with Anatomical-Aware Contrastive DistillationSource quoteTable \ref{table:acdc_main} shows the evaluation results on ACDC dataset under two unlabeled settings (3 or 7 labeled cases). ACTION can substantially improve results on two unlabeled settings, greatly outperforming the previous state-of-the-art SSL methods. Specifically, our ACTION, trained on 3 labeled cases, dramatically improves the previous best averaged Dice score from 73.6% to 87.5% by a large margin, and even matches previous SSL methods using 7 labeled cases. When using 7 labeled cases, ACTION further pushes the state-of-the-art results to 89.7% in Dice. We observe that the gains are more pronounced on the two categories(i.e., RV and Myo), and our ACTION achieves 89.8% and 86.7% in terms of Dice, performing competitive or even better than the supervised baseline (89.2% and 86.7%). As shown in Figure \ref{fig:vis_acdc}, we can see the clear advantage of ACTION, where the boundaries of different regions are clearly sharper and more accurate such as RV and Myo regions. Table \ref{table:lits_main} also shows the evaluation results on LiTS dataset under two unlabeled settings (5% or 10% labeled cases). On both two labeled settings, ACTION significantly outperforms all the state-of-the-art methods by a significant margin. As shown in Figure \ref{fig:vis_lits}, ACTION achieves consistently sharp and accurate object boundaries compared to other SSL methods. |
| 3 | MC-Net+ SOTA frontier (+1 variant) | 88.51% | 2022-01-01 | labeled-data=20% · unlabeled-data=80% · 20% labeled and 80% unlabeled scans; average over myocardium, left ventricle, and rig… | Mutual consistency learning for semi-supervised medical image segmentationSource quoteMC-Net+ (Ours) │ 88.51 │ 80.19 │ 5.35 │ 1.54 │ 1.81 │ 2.99 |
| 4 | DCPA | 85.86% | 2023-08-01 | labeled_scans=3 (5%) · dimensionality=2D · unlabeled_scans=67 (95%) · 2D segmentation; 3 labeled scans (5%) and 67 unlabeled scans (95%); Dice averaged acr… | Dual-Decoder Consistency via Pseudo-Labels Guided Data Augmentation for Semi-Supervised Medical Image SegmentationSource quoteOurs │ 85.86 │ 76.13 │ 5.83 │ 2.03 |
| 5 | AdvMIM | 85.4% | 2025-01-01 | labeled-data=3% · 3% labeled-data partition; semi-supervised medical image segmentation. | AdvMIM: Adversarial Masked Image Modeling for Semi-supervised Medical Image SegmentationSource quoteAdvMIM │ 85.4_{(10.1\textcolor{green}{\uparrow})} │ 2.0_{(8.7\textcolor{red}{\downarrow})} │ 89.0_{(0.6\textcolor{green}{\uparrow})} │ 1.3_{(3.1\textcolor{red}{\downarrow})} │ 66.3_{(1.0\textcolor{green}{\uparrow})} │ 22.7_{(9.9\textcolor{red}{\downarrow})} │ 74.8_{(3.4\textcolor{green}{\uparrow})} │ 15.5_{(15.7\textcolor{red}{\downarrow})} │ 79.8_{(1.9\textcolor{green}{\uparrow})} │ 22.2_{(9.9\textcolor{red}{\downarrow})} │ 81.8_{(0.7\textcolor{green}{\uparrow})} │ 19.5_{(4.9\textcolor{red}{\downarrow})} |
| 6 | Cross-ALD | 80.6% | 2023-10-01 | backbone=U-Net · labeled-data=5% · Semi-supervised segmentation with 5% labeled data (3 labeled scans and 67 unlabeled s… | Cross-adversarial local distribution regularization for semi-supervised medical image segmentationSource quoteCross-ALD (Ours) │ 80.6 │ 69.08 │ 5.96 │ 1.9 │ 1.83 │ 2.99 |
| 7 | AugPaint (+1 variant) | 77.73% | 2025-06-01 | labeled-cases=5 · AugPaint-only row; 5 labeled cases. | Inpainting is All You Need: A Diffusion-based Augmentation Method for Semi-supervised Medical Image SegmentationSource quote\multirow{4}{*}{ACDC} │ AugPaint │ 42.42 │ 44.15 │ 77.73 |
Regimesemi-supervised (65)fine-tuned (21)weakly-supervised (11)domain-generalization (11)test-time-adaptation (10)scribble-supervised (8)
Showing 15 of 15 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | Self-Prompt-SAM proposed | Average DSC | 93.26% | split: test · backbone=SAM | Self-Prompt SAM: Medical Image Segmentation via Automatic Prompt SAM AdaptationSource quoteL157: Self-Prompt-SAM (Ours) │ 93.26 │ 92.20 │ 91.22 │ 96.36 |
| 2024 | DRDM augmentation + vanilla U-Net proposed | Average DSC | 68.2% | split: test · 5-shot · backbone=vanilla U-Net · augmentation=DRDM · labeled-subjects=5 (5%) | Deformation-Recovery diffusion model (DRDM): Instance deformation for image manipulation and synthesisSource quoteL556: DRDM │ 77.0 │ {73.7} │ 84.1 │ 59.6 │ 55.8 │ 77.3 │ 67.9 │ 68.5 │ 73.4 │ 68.2 │ 66.0 │ 78.3 |
| 2024 | 2D AgileFormer proposed | average DSC | 92.55% | split: test · dimension=2D · resolution=224×224 | AgileFormer: Spatially Agile Transformer UNet for Medical Image SegmentationSource quoteL252: One the ACDC dataset, AgileFormer achieved an average DSC (%) of 92.55, surpassing all the baseline methods in segmenting RV, Myo, and LV (see~\Cref{tab:ACDC}; 2D Models). |
| 2024 | 3D AgileFormer proposed | average DSC | 92.07% | dimension=3D · resolution=14×160×160 | AgileFormer: Spatially Agile Transformer UNet for Medical Image SegmentationSource quoteL256: When comparing 3D models, 3D AgileFormer also outperformed other state-of-the-art segmentation methods across all three segmentation tasks. Specifically, AgileFormer achieved an average DSC (%) of 87.43 and an average HD95 (mm) of 7.81, surpassing nnFormer by 0.86 and 2.82 in DSC and HD95, respectively (\Cref{tab:synapse}; 3D Models). On the ACDC dataset, AgileFormer achieved an average DSC (%) of 92.07, outperforming nnFormer by 0.23 (\Cref{tab:ACDC}; 3D Models). |
| 2024 | BigAug augmentation + vanilla U-Net baseline | Average DSC | 57.7% | split: test · 5-shot · backbone=vanilla U-Net · augmentation=BigAug · labeled-subjects=5 (5%) | Deformation-Recovery diffusion model (DRDM): Instance deformation for image manipulation and synthesisSource quoteL553: BigAug │ 75.8 │ 73.6 │ {83.2} │ 37.6 │ 29.6 │ 65.2 │ 65.6 │ 66.0 │ 69.1 │ 59.7 │ 57.7 │ 72.5 |
| 2024 | U-Mamba baseline | Average DSC | 92.22% | anatomy=heart · dimension=3D · metric-aggregation=average across RV, Myo, and LV | UU-Mamba: Uncertainty-aware U-Mamba for Cardiovascular SegmentationSource quoteL281: U-Mamba \cite{ma2024umamba} │ 92.22 │ 91.83 │ 90.22 │ 94.54 |
| 2023 | ACTION proposed | Average DSC | 87.5% | 3 labeled cases (5% setting); table reports DSC/ASD. | ACTION++: Improving Semi-supervised Medical Image Segmentation with Adaptive Anatomical ContrastSource quoteL322: {87.5}/{1.12} |
| 2023 | ACTION++ proposed | Average DSC | 88.5% | 3 labeled cases (5% setting); table reports DSC/ASD. | ACTION++: Improving Semi-supervised Medical Image Segmentation with Adaptive Anatomical ContrastSource quoteL332: \tf{88.5}/\tf{0.723} |
| 2023 | ACTION proposed | Average DSC | 89.7% | 7 labeled cases (10% setting); table reports DSC/ASD. | ACTION++: Improving Semi-supervised Medical Image Segmentation with Adaptive Anatomical ContrastSource quoteL326: {89.7}/{0.736} |
| 2023 | ACTION++ proposed | Average DSC | 90.4% | 7 labeled cases (10% setting); table reports DSC/ASD. | ACTION++: Improving Semi-supervised Medical Image Segmentation with Adaptive Anatomical ContrastSource quoteL336: \tf{90.4}/\tf{0.592} |
| 2022 | Proposed method (RCS + DTS + fuzzy fusion) proposed | Average DSC | 0.889 | semi-supervised · labeled-data=10% | Addressing Class Imbalance in Semi-supervised Image Segmentation: A Study on Cardiac MRISource quoteL148: 0.889 |
| 2022 | D-Former proposed | average DSC | 92.29% | Evaluated on ACDC without pre-training; D-Former is trained from scratch. | D-former: a U-shaped Dilated Transformer for 3D medical image segmentationSource quoteL189: Quantitative results on the ACDC dataset are reported in Table \ref{table:acdc}, and a similar conclusion can be drawn. D-Former achieves the best average DSC of 92.29% |
| 2022 | Global + Local CL baseline | Average DSC | 0.886 | semi-supervised · labeled-data=10% | Addressing Class Imbalance in Semi-supervised Image Segmentation: A Study on Cardiac MRISource quoteL141: \multicolumn{1}{c|}{0.886} |
| 2021 | nnFormer proposed | Average DSC | 92.06% | split: test · repeats=10 · data-split=70 train / 10 validation / 20 test | nnFormer: Volumetric Medical Image Segmentation via a 3D TransformerSource quoteL225: nnFormer │ 92.06 │ 90.94 │ 89.58 │ 95.65 |
| 2021 | LeViT-UNet-384s baseline | Average DSC | 90.32% | split: test · repeats=10 · data-split=70 train / 10 validation / 20 test | nnFormer: Volumetric Medical Image Segmentation via a 3D TransformerSource quoteL222: LeViT-UNet-384s~\cite{xu2021levit} │ 90.32 │ 89.55 │ 87.64 │ 93.76 |