ACDC

242 papers · 564 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching regime=semi-supervised.

76.881.586.290.9202220242025MC-Net+: 87.1 (2022)MC-Net+: 88.51 (2022)ACTION: 86.7 (2022)ACTION: 89.7 (2022)ACTION: 89.8 (2022)DCPA: 85.86 (2023)Cross-ALD: 80.6 (2023)AdvMIM: 85.4 (2025)TransMedSeg: 89.96 (2025)AugPaint: 42.42 (2025)AugPaint: 77.73 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 15 of 15 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025Self-Prompt-SAM proposedAverage DSC93.26%split: test · backbone=SAMSelf-Prompt SAM: Medical Image Segmentation via Automatic Prompt SAM Adaptation
Source quote
L157: Self-Prompt-SAM (Ours) │ 93.26 │ 92.20 │ 91.22 │ 96.36
2024DRDM augmentation + vanilla U-Net proposedAverage DSC68.2%split: test · 5-shot · backbone=vanilla U-Net · augmentation=DRDM · labeled-subjects=5 (5%)Deformation-Recovery diffusion model (DRDM): Instance deformation for image manipulation and synthesis
Source quote
L556: DRDM │ 77.0 │ {73.7} │ 84.1 │ 59.6 │ 55.8 │ 77.3 │ 67.9 │ 68.5 │ 73.4 │ 68.2 │ 66.0 │ 78.3
20242D AgileFormer proposedaverage DSC92.55%split: test · dimension=2D · resolution=224×224AgileFormer: Spatially Agile Transformer UNet for Medical Image Segmentation
Source quote
L252: One the ACDC dataset, AgileFormer achieved an average DSC (%) of 92.55, surpassing all the baseline methods in segmenting RV, Myo, and LV (see~\Cref{tab:ACDC}; 2D Models).
20243D AgileFormer proposedaverage DSC92.07%dimension=3D · resolution=14×160×160AgileFormer: Spatially Agile Transformer UNet for Medical Image Segmentation
Source quote
L256: When comparing 3D models, 3D AgileFormer also outperformed other state-of-the-art segmentation methods across all three segmentation tasks. Specifically, AgileFormer achieved an average DSC (%) of 87.43 and an average HD95 (mm) of 7.81, surpassing nnFormer by 0.86 and 2.82 in DSC and HD95, respectively (\Cref{tab:synapse}; 3D Models). On the ACDC dataset, AgileFormer achieved an average DSC (%) of 92.07, outperforming nnFormer by 0.23 (\Cref{tab:ACDC}; 3D Models).
2024BigAug augmentation + vanilla U-Net baselineAverage DSC57.7%split: test · 5-shot · backbone=vanilla U-Net · augmentation=BigAug · labeled-subjects=5 (5%)Deformation-Recovery diffusion model (DRDM): Instance deformation for image manipulation and synthesis
Source quote
L553: BigAug │ 75.8 │ 73.6 │ {83.2} │ 37.6 │ 29.6 │ 65.2 │ 65.6 │ 66.0 │ 69.1 │ 59.7 │ 57.7 │ 72.5
2024U-Mamba baselineAverage DSC92.22%anatomy=heart · dimension=3D · metric-aggregation=average across RV, Myo, and LVUU-Mamba: Uncertainty-aware U-Mamba for Cardiovascular Segmentation
Source quote
L281: U-Mamba \cite{ma2024umamba} │ 92.22 │ 91.83 │ 90.22 │ 94.54
2023ACTION proposedAverage DSC87.5%3 labeled cases (5% setting); table reports DSC/ASD.ACTION++: Improving Semi-supervised Medical Image Segmentation with Adaptive Anatomical Contrast
Source quote
L322: {87.5}/{1.12}
2023ACTION++ proposedAverage DSC88.5%3 labeled cases (5% setting); table reports DSC/ASD.ACTION++: Improving Semi-supervised Medical Image Segmentation with Adaptive Anatomical Contrast
Source quote
L332: \tf{88.5}/\tf{0.723}
2023ACTION proposedAverage DSC89.7%7 labeled cases (10% setting); table reports DSC/ASD.ACTION++: Improving Semi-supervised Medical Image Segmentation with Adaptive Anatomical Contrast
Source quote
L326: {89.7}/{0.736}
2023ACTION++ proposedAverage DSC90.4%7 labeled cases (10% setting); table reports DSC/ASD.ACTION++: Improving Semi-supervised Medical Image Segmentation with Adaptive Anatomical Contrast
Source quote
L336: \tf{90.4}/\tf{0.592}
2022Proposed method (RCS + DTS + fuzzy fusion) proposedAverage DSC0.889semi-supervised · labeled-data=10%Addressing Class Imbalance in Semi-supervised Image Segmentation: A Study on Cardiac MRI
Source quote
L148: 0.889
2022D-Former proposedaverage DSC92.29%Evaluated on ACDC without pre-training; D-Former is trained from scratch.D-former: a U-shaped Dilated Transformer for 3D medical image segmentation
Source quote
L189: Quantitative results on the ACDC dataset are reported in Table \ref{table:acdc}, and a similar conclusion can be drawn. D-Former achieves the best average DSC of 92.29%
2022Global + Local CL baselineAverage DSC0.886semi-supervised · labeled-data=10%Addressing Class Imbalance in Semi-supervised Image Segmentation: A Study on Cardiac MRI
Source quote
L141: \multicolumn{1}{c|}{0.886}
2021nnFormer proposedAverage DSC92.06%split: test · repeats=10 · data-split=70 train / 10 validation / 20 testnnFormer: Volumetric Medical Image Segmentation via a 3D Transformer
Source quote
L225: nnFormer │ 92.06 │ 90.94 │ 89.58 │ 95.65
2021LeViT-UNet-384s baselineAverage DSC90.32%split: test · repeats=10 · data-split=70 train / 10 validation / 20 testnnFormer: Volumetric Medical Image Segmentation via a 3D Transformer
Source quote
L222: LeViT-UNet-384s~\cite{xu2021levit} │ 90.32 │ 89.55 │ 87.64 │ 93.76