AAPM
14 papers · 33 extracted observations · ct reconstruction · Markdown · CSV · JSON API
Tasks on AAPMAll tasks (14)Ct Reconstruction (4)Image Denoising (3)Image Reconstruction (3)Artifact Removal (1)Ct Denoising (1)Dose Prediction (1)Sparse View Ct Reconstruction (1)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Proposed/measured results matching task=Ct Reconstruction, split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | SCOPE SOTA frontier (+1 variant) | 44.33 | 2023-01-01 | beam=parallel · views=120 · 120 input views; AAPM test set (4 slices). SCOPE reconstructs from a single SV sinogr… | Self-Supervised Coordinate Projection Network for Sparse-View Computed TomographySource quote120 │ 28.30/0.5869/0.2567 │ 24.99/0.7909/0.0454 │ 39.71/{\color{blue}{0.9716}}/0.0123 │ {\color{blue}{44.14}}/0.9644/0.0047 │ 43.86/0.9688/{\color{blue}{0.0043}} │ {\color{red}{44.33}}/{\color{red}{0.9860}}/{\color{red}{0.0037}} |
| 2 | EPNet (ExtraPolationNetwork) SOTA frontier | 27.63 | 2021-01-01 | noise=5% Gaussian plus Poisson (intensity 5e6) · geometry=fan-beam · alpha-max=60 · detector-elements=800 · αmax=60. NIH-AAPM test split: 1,716 slices from five patients; models trained on 1,74… | Improving Generalizability in Limited-Angle CT Reconstruction with Sinogram ExtrapolationSource quoteEPNet │ 21.92 │ 0.820 │ 23.65 │ 0.842 │ 27.63 │ 0.882 │ 30.40 │ 0.906 │ 1.8859 |
Other primary task on AAPM: Ct Reconstruction · SSIM ↑ · test (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DEFT SOTA frontier | 0.887 | 2024-01-01 | angles=60 · sampling-steps=100 DDIM · measurement-noise=Gaussian, σ_y=1.0 · Parallel-beam Radon transform with 60 angles and Gaussian measurement noise σ_y = 1.0… | DEFT: Efficient Fine-tuning of Diffusion Models by Learning the Generalised $h$-transformSource quoteSSIM │ 0.885 │ 0.865 │ 0.887 │ 0.846 │ 0.849 │ 0.876 |
| 2 | EPNet (ExtraPolationNetwork) SOTA frontier | 0.882 | 2021-01-01 | noise=5% Gaussian plus Poisson (intensity 5e6) · geometry=fan-beam · alpha-max=60 · detector-elements=800 · αmax=60. NIH-AAPM test split: 1,716 slices from five patients; models trained on 1,74… | Improving Generalizability in Limited-Angle CT Reconstruction with Sinogram ExtrapolationSource quoteEPNet │ 21.92 │ 0.820 │ 23.65 │ 0.842 │ 27.63 │ 0.882 │ 30.40 │ 0.906 │ 1.8859 |
TaskCt Reconstruction (15)Image Denoising (7)Image Reconstruction (6)Ct Denoising (2)Sparse View Ct Reconstruction (1)Artifact Removal (1)Dose Prediction (1)
Splittest (13)
Showing 13 of 13 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2024 | Blaze3DM proposed | PSNR ↑ | 38.39 | Sparse View Ct Reconstruction · split: test · compressed · views=36 | Blaze3DM: Marry Triplane Representation with Diffusion for 3D Medical Inverse Problem SolvingSource quoteL221: Blaze3DM (Ours) │ 38.39 │ 0.951 │ 0.951 │ 0.951 │ 38.13 |
| 2022 | Proposed patch-wise deep metric learning proposed | PSNR | 38.110 | Image Denoising · split: test | Patch-Wise Deep Metric Learning for Unsupervised Low-Dose CT DenoisingSource quoteL132: PSNR │ 33.300 │ 38.110 │ 37.855 │ 37.795 │ 37.736 │ 37.673 |
| 2022 | Proposed patch-wise deep metric learning proposed | SSIM | 0.875 | Image Denoising · split: test | Patch-Wise Deep Metric Learning for Unsupervised Low-Dose CT DenoisingSource quoteL133: SSIM │ 0.740 │ 0.875 │ 0.867 │ 0.867 │ 0.867 │ 0.865 |
| 2022 | SCOPE proposed | PSNR | 42.18 | Ct Reconstruction · split: test · beam=parallel · views=90 | Self-Supervised Coordinate Projection Network for Sparse-View Computed TomographySource quoteL214: 90 │ 24.40/0.4328/0.3424 │ 22.37/0.6937/0.0747 │ 38.89/{\color{blue}{0.9664}}/0.0139 │ {\color{blue}{41.95}}/0.9557/{\color{blue}{0.0078}} │ 41.74/0.9587/0.0079 │ {\color{red}{42.18}}/{\color{red}{0.9794}}/{\color{red}{0.0066}} |
| 2022 | SCOPE proposed | PSNR | 44.33 | Ct Reconstruction · split: test · beam=parallel · views=120 | Self-Supervised Coordinate Projection Network for Sparse-View Computed TomographySource quoteL215: 120 │ 28.30/0.5869/0.2567 │ 24.99/0.7909/0.0454 │ 39.71/{\color{blue}{0.9716}}/0.0123 │ {\color{blue}{44.14}}/0.9644/0.0047 │ 43.86/0.9688/{\color{blue}{0.0043}} │ {\color{red}{44.33}}/{\color{red}{0.9860}}/{\color{red}{0.0037}} |
| 2022 | Invertible-cycleGAN baseline | PSNR | 37.855 | Image Denoising · split: test | Patch-Wise Deep Metric Learning for Unsupervised Low-Dose CT DenoisingSource quoteL132: PSNR │ 33.300 │ 38.110 │ 37.855 │ 37.795 │ 37.736 │ 37.673 |
| 2022 | Invertible-cycleGAN baseline | SSIM | 0.867 | Image Denoising · split: test | Patch-Wise Deep Metric Learning for Unsupervised Low-Dose CT DenoisingSource quoteL133: SSIM │ 0.740 │ 0.875 │ 0.867 │ 0.867 │ 0.867 │ 0.865 |
| 2022 | FBPConvNet baseline | PSNR | 41.95 | Ct Reconstruction · split: test · beam=parallel · views=90 | Self-Supervised Coordinate Projection Network for Sparse-View Computed TomographySource quoteL214: 90 │ 24.40/0.4328/0.3424 │ 22.37/0.6937/0.0747 │ 38.89/{\color{blue}{0.9664}}/0.0139 │ {\color{blue}{41.95}}/0.9557/{\color{blue}{0.0078}} │ 41.74/0.9587/0.0079 │ {\color{red}{42.18}}/{\color{red}{0.9794}}/{\color{red}{0.0066}} |
| 2022 | FBPConvNet baseline | PSNR | 44.14 | Ct Reconstruction · split: test · beam=parallel · views=120 | Self-Supervised Coordinate Projection Network for Sparse-View Computed TomographySource quoteL215: 120 │ 28.30/0.5869/0.2567 │ 24.99/0.7909/0.0454 │ 39.71/{\color{blue}{0.9716}}/0.0123 │ {\color{blue}{44.14}}/0.9644/0.0047 │ 43.86/0.9688/{\color{blue}{0.0043}} │ {\color{red}{44.33}}/{\color{red}{0.9860}}/{\color{red}{0.0037}} |
| 2021 | Cycle-free CycleGAN with invertible generator (Proposed) proposed non-standard slice | PSNR | 34.940 | Ct Denoising · split: test · dose=25% of standard dose · subset=421 test images | Cycle-Free CycleGAN Using Invertible Generator for Unsupervised Low-Dose CT DenoisingSource quoteL568: Proposed │ 34.940 │ 0.821 |
| 2021 | EPNet (ExtraPolationNetwork) proposed | PSNR | 27.63 | Ct Reconstruction · split: test · noise=5% Gaussian plus Poisson (intensity 5e6) · geometry=fan-beam · alpha-max=60 · detector-elements=800 | Improving Generalizability in Limited-Angle CT Reconstruction with Sinogram ExtrapolationSource quoteL160: EPNet │ 21.92 │ 0.820 │ 23.65 │ 0.842 │ 27.63 │ 0.882 │ 30.40 │ 0.906 │ 1.8859 |
| 2021 | EPNet (ExtraPolationNetwork) proposed | SSIM | 0.882 | Ct Reconstruction · split: test · noise=5% Gaussian plus Poisson (intensity 5e6) · geometry=fan-beam · alpha-max=60 · detector-elements=800 | Improving Generalizability in Limited-Angle CT Reconstruction with Sinogram ExtrapolationSource quoteL160: EPNet │ 21.92 │ 0.820 │ 23.65 │ 0.842 │ 27.63 │ 0.882 │ 30.40 │ 0.906 │ 1.8859 |
| 2021 | AdaIN-based CycleGAN baseline non-standard slice | PSNR | 34.801 | Ct Denoising · split: test · dose=25% of standard dose · subset=421 test images | Cycle-Free CycleGAN Using Invertible Generator for Unsupervised Low-Dose CT DenoisingSource quoteL567: AdaIN-based CycleGAN │ 34.801 │ 0.824 |