AAPM

14 papers · 33 extracted observations · ct reconstruction · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Ct Reconstruction, split=test.

26.332.839.245.7202120222023EPNet (ExtraPolationNetwork): 27.63 (2021)SCOPE: 42.18 (2023)SCOPE: 44.33 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 21 of 21 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025ADDiff-Dose proposedDICE0.927Dose PredictionConditional Diffusion Model with Anatomical-Dose Dual Constraints for End-to-End Multi-Tumor Dose Prediction
Source quote
L475: To verify the performance advantages of the proposed model in dose prediction tasks, we conducted a comprehensive comparison with current mainstream advanced models, including UNet~\cite{bertels2022convolutional}, GAN~\cite{goodfellow2014generative}, DeepLabV3+ \cite{chen2018encoder}, MD-Dose ~\cite{fu2025mddosediffusionmodelbased}, DoseDiff ~\cite{10486983} and DoseNet ~\cite{kearney2018dosenet}. The experimental results, as shown in Tables 3 and 4, demonstrate that the proposed model exhibits significant advantages across multiple core metrics. In terms of the MAE metric, the error values of the proposed model on the public dataset, the Affiliated Hospital of Xiangnan University, Chenzhou Third People's Hospital, and Jiangxi Provincial Cancer Hospital are 0.101, 0.103, 0.139, and 0.154, respectively, all lower than those of other compared models (e.g., DoseNet has an MAE of 0.156 on the public dataset). Notably, on the two key metrics of \DeltaHI (0.038 ± 0.004) and \Delta D_{\text{98}} (0.024 ± 0.011), compared to DoseNet, which ranked second (\DeltaHI = 0.042 ± 0.018, \Delta D_{\text{98}} = 0.032 ± 0.017), the proposed model reduced the values by 0.004 and 0.008, respectively, showing a significant improvement in error control capability. Additionally, on the \Delta D_{\text{2}} (0.001 ± 0.001) and \Delta D_{\text{max}} (0.0005 ± 0.0006) metrics, the values of the proposed model are only 1/10 to 1/3 of those of other advanced models, highlighting its superior spatial localization accuracy. Through paired t-test analysis, the differences between the proposed model and models such as UNet, GAN, DeepLabV3+, and DoseNet in terms of metrics like MAE, DICE, and HD95 are statistically significant (P < 0.05), proving that the performance improvements are not coincidental. To further benchmark our model against contemporary diffusion-based approaches, we compared ADDiff-Dose with the reported performance of DoseDiff ~\cite{10486983} and MD-Dose ~\cite{fu2025mddosediffusionmodelbased} on the AAPM dataset. As shown in Table 2, ADDiff-Dose achieves a superior MAE of 0.101 and DICE of 0.927, compared to DoseDiff (MAE: 0.118) and MD-Dose (DICE: 0.905), underscoring the benefit of our dual-constraint design and lightweight VAE.
2024DEFT proposedSSIM0.887Ct Reconstruction · angles=60 · sampling-steps=100 DDIM · measurement-noise=Gaussian, σ_y=1.0DEFT: Efficient Fine-tuning of Diffusion Models by Learning the Generalised $h$-transform
Source quote
L213: SSIM │ 0.885 │ 0.865 │ 0.887 │ 0.846 │ 0.849 │ 0.876
2024DEFT proposedTime (sampling time per image)16.3 sCt Reconstruction · angles=60 · hardware=GeForce RTX 3090 · sampling-steps=100 DDIM · measurement-noise=Gaussian, σ_y=1.0DEFT: Efficient Fine-tuning of Diffusion Models by Learning the Generalised $h$-transform
Source quote
L214: Time (s) │ 208.9 │ 83.4 │ 16.3 │ 156.8 │ 70.1 │ 13.8
2024Gradient-like method (Alg. \ref{alg:gradientLikeAlgorithm_v3}) proposedPSNR37.33Image Reconstruction · noise=5% relative Gaussian · angles=60 · measurement=parallel-beam Radon · evaluation-patient=C027Convergence Properties of Score-Based Models using Graduated Optimisation for Linear Inverse Problems
Source quote
L252: std │ 0.019 │ 0.001 \multirow{4}{*}{\rotatebox[origin=c]{90}{\parbox[c]{1.2cm}{AAPM}}} │ \multirow{ 2}{*}{PSNR} │ mean │ 35.89 │ 37.33
2024Gradient-like method (Alg. \ref{alg:gradientLikeAlgorithm_v3}) proposedSSIM0.913Image Reconstruction · noise=5% relative Gaussian · angles=60 · measurement=parallel-beam Radon · evaluation-patient=C027Convergence Properties of Score-Based Models using Graduated Optimisation for Linear Inverse Problems
Source quote
L254: \multirow{ 2}{*}{SSIM} │ mean │ 0.899 │ 0.913
2024aSeqDIP proposedSSIM0.92Image Reconstruction · compressed · views=30 · averaged-images=20Image Reconstruction Via Autoencoding Sequential Deep Image Prior
Source quote
L298: Compared to data-independent methods, i.e., the baselines that do not depend on a reference image or pre-trained models, aSeqDIP demonstrates improved PSNR and SSIM scores. For example, aSeqDIP, apart from Self-Guided DIP, shows nearly a 1dB improvement for MRI 8X acceleration compared to conventional methods. For the task of 30-views CT, aSeqDIP reports SSIM score of 0.92 which is 5% more than the second best, which is Self-Guided DIP with SSIM of 0.872. Although improvements against Self-Guided DIP are generally marginal in terms of reconstruction quality, our method proves to be 2X faster for MRI and CT reconstruction and requires 1 minute less than Self-Guided DIP for denoising and in-painting. This speed-up is attributed to updating the input using one forward pass of the trained network at each iteration k, instead of computing gradients with respect to the input for the update. Compared to Vanilla DIP, our method, on average, only requires an additional 30 to 60 seconds. When compared to ES-DIP [27], our method requires longer time, but on average achieves better reconstruction results across three tasks and different settings.
2024Blaze3DM proposedPSNR ↑38.39Sparse View Ct Reconstruction · split: test · compressed · views=36Blaze3DM: Marry Triplane Representation with Diffusion for 3D Medical Inverse Problem Solving
Source quote
L221: Blaze3DM (Ours) │ 38.39 │ 0.951 │ 0.951 │ 0.951 │ 38.13
2024IHQS_p-CG proposedMAE6.97Ct Reconstruction · I0=5×10^5 · views=60 · noise-sigma=0.3Deep Inertia $L_{p}$ Half-Quadratic Splitting Unrolling Network for Sparse View CT Reconstruction
Source quote
L294: 60 │ 26.72/33.85 │ 14.30/19.43 │ 8.44/12.54 │ 7.19/11.31 │ 13.36/718.63 │ 6.97/11.04 │ 8.32/13.56 │ 6.43/10.03 │ 5.71/8.44 │ 6.37/9.50 │ {\color{red} 5.47}/{\color{red} 8.05}
2024IHQS_p-Net proposedMAE5.47Ct Reconstruction · I0=5×10^5 · views=60 · noise-sigma=0.3Deep Inertia $L_{p}$ Half-Quadratic Splitting Unrolling Network for Sparse View CT Reconstruction
Source quote
L294: 60 │ 26.72/33.85 │ 14.30/19.43 │ 8.44/12.54 │ 7.19/11.31 │ 13.36/718.63 │ 6.97/11.04 │ 8.32/13.56 │ 6.43/10.03 │ 5.71/8.44 │ 6.37/9.50 │ {\color{red} 5.47}/{\color{red} 8.05}
2023Dn-Dp with AdaLam-I&II proposed non-standard sliceSSIM0.973Image Denoising · 0-shot · dose=quarter-dose · subset=80 CT slices · anatomy=abdomenDiffusion probabilistic priors for zero‐shot low‐dose CT image denoising
Source quote
L272: ~ │ SSIM │ 0.971 │ 0.972 │ 0.972 │ 0.973
2022Proposed patch-wise deep metric learning proposedPSNR38.110Image Denoising · split: testPatch-Wise Deep Metric Learning for Unsupervised Low-Dose CT Denoising
Source quote
L132: PSNR │ 33.300 │ 38.110 │ 37.855 │ 37.795 │ 37.736 │ 37.673
2022Proposed patch-wise deep metric learning proposedSSIM0.875Image Denoising · split: testPatch-Wise Deep Metric Learning for Unsupervised Low-Dose CT Denoising
Source quote
L133: SSIM │ 0.740 │ 0.875 │ 0.867 │ 0.867 │ 0.867 │ 0.865
2022SCOPE proposedPSNR42.18Ct Reconstruction · split: test · beam=parallel · views=90Self-Supervised Coordinate Projection Network for Sparse-View Computed Tomography
Source quote
L214: 90 │ 24.40/0.4328/0.3424 │ 22.37/0.6937/0.0747 │ 38.89/{\color{blue}{0.9664}}/0.0139 │ {\color{blue}{41.95}}/0.9557/{\color{blue}{0.0078}} │ 41.74/0.9587/0.0079 │ {\color{red}{42.18}}/{\color{red}{0.9794}}/{\color{red}{0.0066}}
2022SCOPE proposedPSNR44.33Ct Reconstruction · split: test · beam=parallel · views=120Self-Supervised Coordinate Projection Network for Sparse-View Computed Tomography
Source quote
L215: 120 │ 28.30/0.5869/0.2567 │ 24.99/0.7909/0.0454 │ 39.71/{\color{blue}{0.9716}}/0.0123 │ {\color{blue}{44.14}}/0.9644/0.0047 │ 43.86/0.9688/{\color{blue}{0.0043}} │ {\color{red}{44.33}}/{\color{red}{0.9860}}/{\color{red}{0.0037}}
2022SCOPE proposedPSNR40.92 dBCt Reconstruction · beam=fan · views=90Self-Supervised Coordinate Projection Network for Sparse-View Computed Tomography
Source quote
L248: \subsubsection{Fan X-ray Beam SVCT} Table \ref{table:ablation-compraison_fan} demonstrates the quantitative results of the compared methods on the two datasets for fan X-ray beam SVCT of 60, 90, and 120 views. We observe that the proposed SCOPE and GRFF \cite{tancik2020fourier} respectively produce the best and second-best performance in terms of all the three metrics for all the cases. For example, on the AAPM dataset for 90 input views, SCOPE and GRFF respectively achieve 40.92 \mathsf{dB} and 37.54 \mathsf{dB}, while TF U-Net \cite{han2018framing} only obtains 32.47 \mathsf{dB} in terms of PSNR. It is not common that FBPConvNet \cite{FBPConvNet} and TF U-Net cannot produce the satisfactory performance on the AAPM dataset although they are trained on the AAPM dataset. We guess that, for learning the end-to-end mapping as in the supervised DL methods, the fan X-ray beam CT is a more difficult task than the parallel X-ray beam CT when same input views. In our experiments, for the sinograms of the same projection views, the results of the fan X-ray CT include more severe streaking artifacts than that of the parallel X-ray CT after applying the FBP algorithm \cite{fbp}. While FBPConvNet \cite{FBPConvNet} and TF U-Net \cite{han2018framing} directly learn the inverse mapping from the artifacts-corrupted inputs to the artifacts-free outputs. Therefore, they are not expected to perform as well in the fan X-ray CT as in the parallel X-ray CT. In contrast, GRFF \cite{tancik2020fourier} and SCOPE train neural network to learn the implicit function of the unknown CT image by computing the loss on the SV sinogram (i.e., they do not manipulate image information directly). Thus, they all work well for different types of X-ray beams. Figure \ref{fig:com_fan_aapm} \ │ \ref{fig:com_fan_covid19} show the qualitative results on two test samples (\#104 and \#95) from the two datasets for fan X-ray beam SVCT reconstruction of 90 views. We see that the four compared methods do not recover the good results. The results from FBP algorithm \cite{fbp} and CoIL \cite{sun2021coil} include severe streaking artifacts, while FBPConvNet \cite{FBPConvNet} and TF U-Net \cite{han2018framing} produce the overly smooth results. GRFF \cite{tancik2020fourier} obtains the second-best results that lost some image details. Only the proposed SCOPE removes streaking artifacts greatly and preserves fine image details well.
2021Cycle-free CycleGAN with invertible generator (Proposed) proposed non-standard slicePSNR34.940Ct Denoising · split: test · dose=25% of standard dose · subset=421 test imagesCycle-Free CycleGAN Using Invertible Generator for Unsupervised Low-Dose CT Denoising
Source quote
L568: Proposed │ 34.940 │ 0.821
2021Switchable FedCycleGAN vs non-federated CycleGAN proposedPSNR0.045 dBImage Denoising · clients=2Federated CycleGAN for Privacy-Preserving Image-to-Image Translation
Source quote
L314: We found that results of non-federated CycleGAN and results of Switchable FedCycleGAN showed small differences in terms of PSNR and SSIM. The difference in PSNR values is 0.045 dB, while the difference in SSIM values is 0.0017.
2021Switchable FedCycleGAN vs non-federated CycleGAN proposedSSIM0.0017Image Denoising · clients=2Federated CycleGAN for Privacy-Preserving Image-to-Image Translation
Source quote
L314: We found that results of non-federated CycleGAN and results of Switchable FedCycleGAN showed small differences in terms of PSNR and SSIM. The difference in PSNR values is 0.045 dB, while the difference in SSIM values is 0.0017.
2021EPNet (ExtraPolationNetwork) proposedPSNR27.63Ct Reconstruction · split: test · noise=5% Gaussian plus Poisson (intensity 5e6) · geometry=fan-beam · alpha-max=60 · detector-elements=800Improving Generalizability in Limited-Angle CT Reconstruction with Sinogram Extrapolation
Source quote
L160: EPNet │ 21.92 │ 0.820 │ 23.65 │ 0.842 │ 27.63 │ 0.882 │ 30.40 │ 0.906 │ 1.8859
2021EPNet (ExtraPolationNetwork) proposedSSIM0.882Ct Reconstruction · split: test · noise=5% Gaussian plus Poisson (intensity 5e6) · geometry=fan-beam · alpha-max=60 · detector-elements=800Improving Generalizability in Limited-Angle CT Reconstruction with Sinogram Extrapolation
Source quote
L160: EPNet │ 21.92 │ 0.820 │ 23.65 │ 0.842 │ 27.63 │ 0.882 │ 30.40 │ 0.906 │ 1.8859
2019FDK-CNN proposedPSNR39.99 dBArtifact Removal · training-data=8 patient datasetsDifferentiated Backprojection Domain Deep Learning for Conebeam Artifact Removal
Source quote
L472: \ PSNR [dB] │ 32.05 │ 34.39 │ 39.99 │ 41.76 │ 42.49