AAPM · Ct Reconstruction
14 papers · 33 extracted observations · ct reconstruction · Markdown · CSV · JSON API
Tasks on AAPMAll tasks (14)Ct Reconstruction (4)Image Denoising (3)Image Reconstruction (3)Artifact Removal (1)Ct Denoising (1)Dose Prediction (1)Sparse View Ct Reconstruction (1)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Proposed/measured results matching task=Ct Reconstruction, split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | SCOPE SOTA frontier (+1 variant) | 44.33 | 2023-01-01 | beam=parallel · views=120 · 120 input views; AAPM test set (4 slices). SCOPE reconstructs from a single SV sinogr… | Self-Supervised Coordinate Projection Network for Sparse-View Computed TomographySource quote120 │ 28.30/0.5869/0.2567 │ 24.99/0.7909/0.0454 │ 39.71/{\color{blue}{0.9716}}/0.0123 │ {\color{blue}{44.14}}/0.9644/0.0047 │ 43.86/0.9688/{\color{blue}{0.0043}} │ {\color{red}{44.33}}/{\color{red}{0.9860}}/{\color{red}{0.0037}} |
| 2 | EPNet (ExtraPolationNetwork) SOTA frontier | 27.63 | 2021-01-01 | noise=5% Gaussian plus Poisson (intensity 5e6) · geometry=fan-beam · alpha-max=60 · detector-elements=800 · αmax=60. NIH-AAPM test split: 1,716 slices from five patients; models trained on 1,74… | Improving Generalizability in Limited-Angle CT Reconstruction with Sinogram ExtrapolationSource quoteEPNet │ 21.92 │ 0.820 │ 23.65 │ 0.842 │ 27.63 │ 0.882 │ 30.40 │ 0.906 │ 1.8859 |
Other primary task on AAPM: Ct Reconstruction · SSIM ↑ · test (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DEFT SOTA frontier | 0.887 | 2024-01-01 | angles=60 · sampling-steps=100 DDIM · measurement-noise=Gaussian, σ_y=1.0 · Parallel-beam Radon transform with 60 angles and Gaussian measurement noise σ_y = 1.0… | DEFT: Efficient Fine-tuning of Diffusion Models by Learning the Generalised $h$-transformSource quoteSSIM │ 0.885 │ 0.865 │ 0.887 │ 0.846 │ 0.849 │ 0.876 |
| 2 | EPNet (ExtraPolationNetwork) SOTA frontier | 0.882 | 2021-01-01 | noise=5% Gaussian plus Poisson (intensity 5e6) · geometry=fan-beam · alpha-max=60 · detector-elements=800 · αmax=60. NIH-AAPM test split: 1,716 slices from five patients; models trained on 1,74… | Improving Generalizability in Limited-Angle CT Reconstruction with Sinogram ExtrapolationSource quoteEPNet │ 21.92 │ 0.820 │ 23.65 │ 0.842 │ 27.63 │ 0.882 │ 30.40 │ 0.906 │ 1.8859 |
TaskCt Reconstruction (15)Image Denoising (7)Image Reconstruction (6)Ct Denoising (2)Sparse View Ct Reconstruction (1)Artifact Removal (1)Dose Prediction (1)
Splittest (13)
Showing 9 of 9 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2024 | DEFT proposed | SSIM | 0.887 | Ct Reconstruction · angles=60 · sampling-steps=100 DDIM · measurement-noise=Gaussian, σ_y=1.0 | DEFT: Efficient Fine-tuning of Diffusion Models by Learning the Generalised $h$-transformSource quoteL213: SSIM │ 0.885 │ 0.865 │ 0.887 │ 0.846 │ 0.849 │ 0.876 |
| 2024 | DEFT proposed | Time (sampling time per image) | 16.3 s | Ct Reconstruction · angles=60 · hardware=GeForce RTX 3090 · sampling-steps=100 DDIM · measurement-noise=Gaussian, σ_y=1.0 | DEFT: Efficient Fine-tuning of Diffusion Models by Learning the Generalised $h$-transformSource quoteL214: Time (s) │ 208.9 │ 83.4 │ 16.3 │ 156.8 │ 70.1 │ 13.8 |
| 2024 | IHQS_p-CG proposed | MAE | 6.97 | Ct Reconstruction · I0=5×10^5 · views=60 · noise-sigma=0.3 | Deep Inertia $L_{p}$ Half-Quadratic Splitting Unrolling Network for Sparse View CT ReconstructionSource quoteL294: 60 │ 26.72/33.85 │ 14.30/19.43 │ 8.44/12.54 │ 7.19/11.31 │ 13.36/718.63 │ 6.97/11.04 │ 8.32/13.56 │ 6.43/10.03 │ 5.71/8.44 │ 6.37/9.50 │ {\color{red} 5.47}/{\color{red} 8.05} |
| 2024 | IHQS_p-Net proposed | MAE | 5.47 | Ct Reconstruction · I0=5×10^5 · views=60 · noise-sigma=0.3 | Deep Inertia $L_{p}$ Half-Quadratic Splitting Unrolling Network for Sparse View CT ReconstructionSource quoteL294: 60 │ 26.72/33.85 │ 14.30/19.43 │ 8.44/12.54 │ 7.19/11.31 │ 13.36/718.63 │ 6.97/11.04 │ 8.32/13.56 │ 6.43/10.03 │ 5.71/8.44 │ 6.37/9.50 │ {\color{red} 5.47}/{\color{red} 8.05} |
| 2022 | SCOPE proposed | PSNR | 42.18 | Ct Reconstruction · split: test · beam=parallel · views=90 | Self-Supervised Coordinate Projection Network for Sparse-View Computed TomographySource quoteL214: 90 │ 24.40/0.4328/0.3424 │ 22.37/0.6937/0.0747 │ 38.89/{\color{blue}{0.9664}}/0.0139 │ {\color{blue}{41.95}}/0.9557/{\color{blue}{0.0078}} │ 41.74/0.9587/0.0079 │ {\color{red}{42.18}}/{\color{red}{0.9794}}/{\color{red}{0.0066}} |
| 2022 | SCOPE proposed | PSNR | 44.33 | Ct Reconstruction · split: test · beam=parallel · views=120 | Self-Supervised Coordinate Projection Network for Sparse-View Computed TomographySource quoteL215: 120 │ 28.30/0.5869/0.2567 │ 24.99/0.7909/0.0454 │ 39.71/{\color{blue}{0.9716}}/0.0123 │ {\color{blue}{44.14}}/0.9644/0.0047 │ 43.86/0.9688/{\color{blue}{0.0043}} │ {\color{red}{44.33}}/{\color{red}{0.9860}}/{\color{red}{0.0037}} |
| 2022 | SCOPE proposed | PSNR | 40.92 dB | Ct Reconstruction · beam=fan · views=90 | Self-Supervised Coordinate Projection Network for Sparse-View Computed TomographySource quoteL248: \subsubsection{Fan X-ray Beam SVCT} Table \ref{table:ablation-compraison_fan} demonstrates the quantitative results of the compared methods on the two datasets for fan X-ray beam SVCT of 60, 90, and 120 views. We observe that the proposed SCOPE and GRFF \cite{tancik2020fourier} respectively produce the best and second-best performance in terms of all the three metrics for all the cases. For example, on the AAPM dataset for 90 input views, SCOPE and GRFF respectively achieve 40.92 \mathsf{dB} and 37.54 \mathsf{dB}, while TF U-Net \cite{han2018framing} only obtains 32.47 \mathsf{dB} in terms of PSNR. It is not common that FBPConvNet \cite{FBPConvNet} and TF U-Net cannot produce the satisfactory performance on the AAPM dataset although they are trained on the AAPM dataset. We guess that, for learning the end-to-end mapping as in the supervised DL methods, the fan X-ray beam CT is a more difficult task than the parallel X-ray beam CT when same input views. In our experiments, for the sinograms of the same projection views, the results of the fan X-ray CT include more severe streaking artifacts than that of the parallel X-ray CT after applying the FBP algorithm \cite{fbp}. While FBPConvNet \cite{FBPConvNet} and TF U-Net \cite{han2018framing} directly learn the inverse mapping from the artifacts-corrupted inputs to the artifacts-free outputs. Therefore, they are not expected to perform as well in the fan X-ray CT as in the parallel X-ray CT. In contrast, GRFF \cite{tancik2020fourier} and SCOPE train neural network to learn the implicit function of the unknown CT image by computing the loss on the SV sinogram (i.e., they do not manipulate image information directly). Thus, they all work well for different types of X-ray beams. Figure \ref{fig:com_fan_aapm} \ │ \ref{fig:com_fan_covid19} show the qualitative results on two test samples (\#104 and \#95) from the two datasets for fan X-ray beam SVCT reconstruction of 90 views. We see that the four compared methods do not recover the good results. The results from FBP algorithm \cite{fbp} and CoIL \cite{sun2021coil} include severe streaking artifacts, while FBPConvNet \cite{FBPConvNet} and TF U-Net \cite{han2018framing} produce the overly smooth results. GRFF \cite{tancik2020fourier} obtains the second-best results that lost some image details. Only the proposed SCOPE removes streaking artifacts greatly and preserves fine image details well. |
| 2021 | EPNet (ExtraPolationNetwork) proposed | PSNR | 27.63 | Ct Reconstruction · split: test · noise=5% Gaussian plus Poisson (intensity 5e6) · geometry=fan-beam · alpha-max=60 · detector-elements=800 | Improving Generalizability in Limited-Angle CT Reconstruction with Sinogram ExtrapolationSource quoteL160: EPNet │ 21.92 │ 0.820 │ 23.65 │ 0.842 │ 27.63 │ 0.882 │ 30.40 │ 0.906 │ 1.8859 |
| 2021 | EPNet (ExtraPolationNetwork) proposed | SSIM | 0.882 | Ct Reconstruction · split: test · noise=5% Gaussian plus Poisson (intensity 5e6) · geometry=fan-beam · alpha-max=60 · detector-elements=800 | Improving Generalizability in Limited-Angle CT Reconstruction with Sinogram ExtrapolationSource quoteL160: EPNet │ 21.92 │ 0.820 │ 23.65 │ 0.842 │ 27.63 │ 0.882 │ 30.40 │ 0.906 │ 1.8859 |