AAPM · Image Reconstruction

14 papers · 33 extracted observations · ct reconstruction · Markdown · CSV · JSON API

Showing 2 of 2 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2024aSeqDIP proposedSSIM0.92Image Reconstruction · compressed · views=30 · averaged-images=20Image Reconstruction Via Autoencoding Sequential Deep Image Prior
Source quote
L298: Compared to data-independent methods, i.e., the baselines that do not depend on a reference image or pre-trained models, aSeqDIP demonstrates improved PSNR and SSIM scores. For example, aSeqDIP, apart from Self-Guided DIP, shows nearly a 1dB improvement for MRI 8X acceleration compared to conventional methods. For the task of 30-views CT, aSeqDIP reports SSIM score of 0.92 which is 5% more than the second best, which is Self-Guided DIP with SSIM of 0.872. Although improvements against Self-Guided DIP are generally marginal in terms of reconstruction quality, our method proves to be 2X faster for MRI and CT reconstruction and requires 1 minute less than Self-Guided DIP for denoising and in-painting. This speed-up is attributed to updating the input using one forward pass of the trained network at each iteration k, instead of computing gradients with respect to the input for the update. Compared to Vanilla DIP, our method, on average, only requires an additional 30 to 60 seconds. When compared to ES-DIP [27], our method requires longer time, but on average achieves better reconstruction results across three tasks and different settings.
2024Self-Guided DIP baselineSSIM0.872Image Reconstruction · compressed · views=30 · averaged-images=20Image Reconstruction Via Autoencoding Sequential Deep Image Prior
Source quote
L298: Compared to data-independent methods, i.e., the baselines that do not depend on a reference image or pre-trained models, aSeqDIP demonstrates improved PSNR and SSIM scores. For example, aSeqDIP, apart from Self-Guided DIP, shows nearly a 1dB improvement for MRI 8X acceleration compared to conventional methods. For the task of 30-views CT, aSeqDIP reports SSIM score of 0.92 which is 5% more than the second best, which is Self-Guided DIP with SSIM of 0.872. Although improvements against Self-Guided DIP are generally marginal in terms of reconstruction quality, our method proves to be 2X faster for MRI and CT reconstruction and requires 1 minute less than Self-Guided DIP for denoising and in-painting. This speed-up is attributed to updating the input using one forward pass of the trained network at each iteration k, instead of computing gradients with respect to the input for the update. Compared to Vanilla DIP, our method, on average, only requires an additional 30 to 60 seconds. When compared to ES-DIP [27], our method requires longer time, but on average achieves better reconstruction results across three tasks and different settings.