AAPM · Image Denoising

14 papers · 33 extracted observations · ct reconstruction · Markdown · CSV · JSON API

Showing 4 of 4 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2023Dn-Dp with AdaLam-I&II proposed non-standard sliceSSIM0.973Image Denoising · 0-shot · dose=quarter-dose · subset=80 CT slices · anatomy=abdomenDiffusion probabilistic priors for zero‐shot low‐dose CT image denoising
Source quote
L272: ~ │ SSIM │ 0.971 │ 0.972 │ 0.972 │ 0.973
2022Proposed patch-wise deep metric learning proposedSSIM0.875Image Denoising · split: testPatch-Wise Deep Metric Learning for Unsupervised Low-Dose CT Denoising
Source quote
L133: SSIM │ 0.740 │ 0.875 │ 0.867 │ 0.867 │ 0.867 │ 0.865
2022Invertible-cycleGAN baselineSSIM0.867Image Denoising · split: testPatch-Wise Deep Metric Learning for Unsupervised Low-Dose CT Denoising
Source quote
L133: SSIM │ 0.740 │ 0.875 │ 0.867 │ 0.867 │ 0.867 │ 0.865
2021Switchable FedCycleGAN vs non-federated CycleGAN proposedSSIM0.0017Image Denoising · clients=2Federated CycleGAN for Privacy-Preserving Image-to-Image Translation
Source quote
L314: We found that results of non-federated CycleGAN and results of Switchable FedCycleGAN showed small differences in terms of PSNR and SSIM. The difference in PSNR values is 0.045 dB, while the difference in SSIM values is 0.0017.