AAPM
14 papers · 33 extracted observations · ct reconstruction · Markdown · CSV · JSON API
Tasks on AAPMAll tasks (14)Ct Reconstruction (4)Image Denoising (3)Image Reconstruction (3)Artifact Removal (1)Ct Denoising (1)Dose Prediction (1)Sparse View Ct Reconstruction (1)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Proposed/measured results matching task=Ct Reconstruction, split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | SCOPE SOTA frontier (+1 variant) | 44.33 | 2023-01-01 | beam=parallel · views=120 · 120 input views; AAPM test set (4 slices). SCOPE reconstructs from a single SV sinogr… | Self-Supervised Coordinate Projection Network for Sparse-View Computed TomographySource quote120 │ 28.30/0.5869/0.2567 │ 24.99/0.7909/0.0454 │ 39.71/{\color{blue}{0.9716}}/0.0123 │ {\color{blue}{44.14}}/0.9644/0.0047 │ 43.86/0.9688/{\color{blue}{0.0043}} │ {\color{red}{44.33}}/{\color{red}{0.9860}}/{\color{red}{0.0037}} |
| 2 | EPNet (ExtraPolationNetwork) SOTA frontier | 27.63 | 2021-01-01 | noise=5% Gaussian plus Poisson (intensity 5e6) · geometry=fan-beam · alpha-max=60 · detector-elements=800 · αmax=60. NIH-AAPM test split: 1,716 slices from five patients; models trained on 1,74… | Improving Generalizability in Limited-Angle CT Reconstruction with Sinogram ExtrapolationSource quoteEPNet │ 21.92 │ 0.820 │ 23.65 │ 0.842 │ 27.63 │ 0.882 │ 30.40 │ 0.906 │ 1.8859 |
Other primary task on AAPM: Ct Reconstruction · SSIM ↑ · test (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DEFT SOTA frontier | 0.887 | 2024-01-01 | angles=60 · sampling-steps=100 DDIM · measurement-noise=Gaussian, σ_y=1.0 · Parallel-beam Radon transform with 60 angles and Gaussian measurement noise σ_y = 1.0… | DEFT: Efficient Fine-tuning of Diffusion Models by Learning the Generalised $h$-transformSource quoteSSIM │ 0.885 │ 0.865 │ 0.887 │ 0.846 │ 0.849 │ 0.876 |
| 2 | EPNet (ExtraPolationNetwork) SOTA frontier | 0.882 | 2021-01-01 | noise=5% Gaussian plus Poisson (intensity 5e6) · geometry=fan-beam · alpha-max=60 · detector-elements=800 · αmax=60. NIH-AAPM test split: 1,716 slices from five patients; models trained on 1,74… | Improving Generalizability in Limited-Angle CT Reconstruction with Sinogram ExtrapolationSource quoteEPNet │ 21.92 │ 0.820 │ 23.65 │ 0.842 │ 27.63 │ 0.882 │ 30.40 │ 0.906 │ 1.8859 |
TaskCt Reconstruction (15)Image Denoising (7)Image Reconstruction (6)Ct Denoising (2)Sparse View Ct Reconstruction (1)Artifact Removal (1)Dose Prediction (1)
Splittest (13)
Showing 2 of 2 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2024 | aSeqDIP proposed | SSIM | 0.92 | Image Reconstruction · compressed · views=30 · averaged-images=20 | Image Reconstruction Via Autoencoding Sequential Deep Image PriorSource quoteL298: Compared to data-independent methods, i.e., the baselines that do not depend on a reference image or pre-trained models, aSeqDIP demonstrates improved PSNR and SSIM scores. For example, aSeqDIP, apart from Self-Guided DIP, shows nearly a 1dB improvement for MRI 8X acceleration compared to conventional methods. For the task of 30-views CT, aSeqDIP reports SSIM score of 0.92 which is 5% more than the second best, which is Self-Guided DIP with SSIM of 0.872. Although improvements against Self-Guided DIP are generally marginal in terms of reconstruction quality, our method proves to be 2X faster for MRI and CT reconstruction and requires 1 minute less than Self-Guided DIP for denoising and in-painting. This speed-up is attributed to updating the input using one forward pass of the trained network at each iteration k, instead of computing gradients with respect to the input for the update. Compared to Vanilla DIP, our method, on average, only requires an additional 30 to 60 seconds. When compared to ES-DIP [27], our method requires longer time, but on average achieves better reconstruction results across three tasks and different settings. |
| 2024 | Self-Guided DIP baseline | SSIM | 0.872 | Image Reconstruction · compressed · views=30 · averaged-images=20 | Image Reconstruction Via Autoencoding Sequential Deep Image PriorSource quoteL298: Compared to data-independent methods, i.e., the baselines that do not depend on a reference image or pre-trained models, aSeqDIP demonstrates improved PSNR and SSIM scores. For example, aSeqDIP, apart from Self-Guided DIP, shows nearly a 1dB improvement for MRI 8X acceleration compared to conventional methods. For the task of 30-views CT, aSeqDIP reports SSIM score of 0.92 which is 5% more than the second best, which is Self-Guided DIP with SSIM of 0.872. Although improvements against Self-Guided DIP are generally marginal in terms of reconstruction quality, our method proves to be 2X faster for MRI and CT reconstruction and requires 1 minute less than Self-Guided DIP for denoising and in-painting. This speed-up is attributed to updating the input using one forward pass of the trained network at each iteration k, instead of computing gradients with respect to the input for the update. Compared to Vanilla DIP, our method, on average, only requires an additional 30 to 60 seconds. When compared to ES-DIP [27], our method requires longer time, but on average achieves better reconstruction results across three tasks and different settings. |