AAPM

14 papers · 33 extracted observations · ct reconstruction · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Ct Reconstruction, split=test.

26.332.839.245.7202120222023EPNet (ExtraPolationNetwork): 27.63 (2021)SCOPE: 42.18 (2023)SCOPE: 44.33 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 17 of 17 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025RegFormer baselinePSNR32.92 dBImage Reconstruction · dose=low-dose (I₀ = 5×10⁵) · views=90Unsupervised Self-Prior Embedding Neural Representation for Iterative Sparse-View CT Reconstruction
Source quote
L210: RegFormer │ 33.11/0.9173 │ 33.77/0.9256 │ 32.40/0.8865 │ 32.92/0.8901
2024Gradient-like method (Alg. \ref{alg:gradientLikeAlgorithm_v3}) proposedPSNR37.33Image Reconstruction · noise=5% relative Gaussian · angles=60 · measurement=parallel-beam Radon · evaluation-patient=C027Convergence Properties of Score-Based Models using Graduated Optimisation for Linear Inverse Problems
Source quote
L252: std │ 0.019 │ 0.001 \multirow{4}{*}{\rotatebox[origin=c]{90}{\parbox[c]{1.2cm}{AAPM}}} │ \multirow{ 2}{*}{PSNR} │ mean │ 35.89 │ 37.33
2024Blaze3DM proposedPSNR ↑38.39Sparse View Ct Reconstruction · split: test · compressed · views=36Blaze3DM: Marry Triplane Representation with Diffusion for 3D Medical Inverse Problem Solving
Source quote
L221: Blaze3DM (Ours) │ 38.39 │ 0.951 │ 0.951 │ 0.951 │ 38.13
2024Gradient Descent baselinePSNR35.89Image Reconstruction · noise=5% relative Gaussian · angles=60 · measurement=parallel-beam Radon · optimization=objective at t_min · evaluation-patient=C027Convergence Properties of Score-Based Models using Graduated Optimisation for Linear Inverse Problems
Source quote
L252: std │ 0.019 │ 0.001 \multirow{4}{*}{\rotatebox[origin=c]{90}{\parbox[c]{1.2cm}{AAPM}}} │ \multirow{ 2}{*}{PSNR} │ mean │ 35.89 │ 37.33
2022Proposed patch-wise deep metric learning proposedPSNR38.110Image Denoising · split: testPatch-Wise Deep Metric Learning for Unsupervised Low-Dose CT Denoising
Source quote
L132: PSNR │ 33.300 │ 38.110 │ 37.855 │ 37.795 │ 37.736 │ 37.673
2022SCOPE proposedPSNR42.18Ct Reconstruction · split: test · beam=parallel · views=90Self-Supervised Coordinate Projection Network for Sparse-View Computed Tomography
Source quote
L214: 90 │ 24.40/0.4328/0.3424 │ 22.37/0.6937/0.0747 │ 38.89/{\color{blue}{0.9664}}/0.0139 │ {\color{blue}{41.95}}/0.9557/{\color{blue}{0.0078}} │ 41.74/0.9587/0.0079 │ {\color{red}{42.18}}/{\color{red}{0.9794}}/{\color{red}{0.0066}}
2022SCOPE proposedPSNR44.33Ct Reconstruction · split: test · beam=parallel · views=120Self-Supervised Coordinate Projection Network for Sparse-View Computed Tomography
Source quote
L215: 120 │ 28.30/0.5869/0.2567 │ 24.99/0.7909/0.0454 │ 39.71/{\color{blue}{0.9716}}/0.0123 │ {\color{blue}{44.14}}/0.9644/0.0047 │ 43.86/0.9688/{\color{blue}{0.0043}} │ {\color{red}{44.33}}/{\color{red}{0.9860}}/{\color{red}{0.0037}}
2022SCOPE proposedPSNR40.92 dBCt Reconstruction · beam=fan · views=90Self-Supervised Coordinate Projection Network for Sparse-View Computed Tomography
Source quote
L248: \subsubsection{Fan X-ray Beam SVCT} Table \ref{table:ablation-compraison_fan} demonstrates the quantitative results of the compared methods on the two datasets for fan X-ray beam SVCT of 60, 90, and 120 views. We observe that the proposed SCOPE and GRFF \cite{tancik2020fourier} respectively produce the best and second-best performance in terms of all the three metrics for all the cases. For example, on the AAPM dataset for 90 input views, SCOPE and GRFF respectively achieve 40.92 \mathsf{dB} and 37.54 \mathsf{dB}, while TF U-Net \cite{han2018framing} only obtains 32.47 \mathsf{dB} in terms of PSNR. It is not common that FBPConvNet \cite{FBPConvNet} and TF U-Net cannot produce the satisfactory performance on the AAPM dataset although they are trained on the AAPM dataset. We guess that, for learning the end-to-end mapping as in the supervised DL methods, the fan X-ray beam CT is a more difficult task than the parallel X-ray beam CT when same input views. In our experiments, for the sinograms of the same projection views, the results of the fan X-ray CT include more severe streaking artifacts than that of the parallel X-ray CT after applying the FBP algorithm \cite{fbp}. While FBPConvNet \cite{FBPConvNet} and TF U-Net \cite{han2018framing} directly learn the inverse mapping from the artifacts-corrupted inputs to the artifacts-free outputs. Therefore, they are not expected to perform as well in the fan X-ray CT as in the parallel X-ray CT. In contrast, GRFF \cite{tancik2020fourier} and SCOPE train neural network to learn the implicit function of the unknown CT image by computing the loss on the SV sinogram (i.e., they do not manipulate image information directly). Thus, they all work well for different types of X-ray beams. Figure \ref{fig:com_fan_aapm} \ │ \ref{fig:com_fan_covid19} show the qualitative results on two test samples (\#104 and \#95) from the two datasets for fan X-ray beam SVCT reconstruction of 90 views. We see that the four compared methods do not recover the good results. The results from FBP algorithm \cite{fbp} and CoIL \cite{sun2021coil} include severe streaking artifacts, while FBPConvNet \cite{FBPConvNet} and TF U-Net \cite{han2018framing} produce the overly smooth results. GRFF \cite{tancik2020fourier} obtains the second-best results that lost some image details. Only the proposed SCOPE removes streaking artifacts greatly and preserves fine image details well.
2022Invertible-cycleGAN baselinePSNR37.855Image Denoising · split: testPatch-Wise Deep Metric Learning for Unsupervised Low-Dose CT Denoising
Source quote
L132: PSNR │ 33.300 │ 38.110 │ 37.855 │ 37.795 │ 37.736 │ 37.673
2022FBPConvNet baselinePSNR41.95Ct Reconstruction · split: test · beam=parallel · views=90Self-Supervised Coordinate Projection Network for Sparse-View Computed Tomography
Source quote
L214: 90 │ 24.40/0.4328/0.3424 │ 22.37/0.6937/0.0747 │ 38.89/{\color{blue}{0.9664}}/0.0139 │ {\color{blue}{41.95}}/0.9557/{\color{blue}{0.0078}} │ 41.74/0.9587/0.0079 │ {\color{red}{42.18}}/{\color{red}{0.9794}}/{\color{red}{0.0066}}
2022FBPConvNet baselinePSNR44.14Ct Reconstruction · split: test · beam=parallel · views=120Self-Supervised Coordinate Projection Network for Sparse-View Computed Tomography
Source quote
L215: 120 │ 28.30/0.5869/0.2567 │ 24.99/0.7909/0.0454 │ 39.71/{\color{blue}{0.9716}}/0.0123 │ {\color{blue}{44.14}}/0.9644/0.0047 │ 43.86/0.9688/{\color{blue}{0.0043}} │ {\color{red}{44.33}}/{\color{red}{0.9860}}/{\color{red}{0.0037}}
2022GRFF baselinePSNR37.54 dBCt Reconstruction · beam=fan · views=90Self-Supervised Coordinate Projection Network for Sparse-View Computed Tomography
Source quote
L248: \subsubsection{Fan X-ray Beam SVCT} Table \ref{table:ablation-compraison_fan} demonstrates the quantitative results of the compared methods on the two datasets for fan X-ray beam SVCT of 60, 90, and 120 views. We observe that the proposed SCOPE and GRFF \cite{tancik2020fourier} respectively produce the best and second-best performance in terms of all the three metrics for all the cases. For example, on the AAPM dataset for 90 input views, SCOPE and GRFF respectively achieve 40.92 \mathsf{dB} and 37.54 \mathsf{dB}, while TF U-Net \cite{han2018framing} only obtains 32.47 \mathsf{dB} in terms of PSNR. It is not common that FBPConvNet \cite{FBPConvNet} and TF U-Net cannot produce the satisfactory performance on the AAPM dataset although they are trained on the AAPM dataset. We guess that, for learning the end-to-end mapping as in the supervised DL methods, the fan X-ray beam CT is a more difficult task than the parallel X-ray beam CT when same input views. In our experiments, for the sinograms of the same projection views, the results of the fan X-ray CT include more severe streaking artifacts than that of the parallel X-ray CT after applying the FBP algorithm \cite{fbp}. While FBPConvNet \cite{FBPConvNet} and TF U-Net \cite{han2018framing} directly learn the inverse mapping from the artifacts-corrupted inputs to the artifacts-free outputs. Therefore, they are not expected to perform as well in the fan X-ray CT as in the parallel X-ray CT. In contrast, GRFF \cite{tancik2020fourier} and SCOPE train neural network to learn the implicit function of the unknown CT image by computing the loss on the SV sinogram (i.e., they do not manipulate image information directly). Thus, they all work well for different types of X-ray beams. Figure \ref{fig:com_fan_aapm} \ │ \ref{fig:com_fan_covid19} show the qualitative results on two test samples (\#104 and \#95) from the two datasets for fan X-ray beam SVCT reconstruction of 90 views. We see that the four compared methods do not recover the good results. The results from FBP algorithm \cite{fbp} and CoIL \cite{sun2021coil} include severe streaking artifacts, while FBPConvNet \cite{FBPConvNet} and TF U-Net \cite{han2018framing} produce the overly smooth results. GRFF \cite{tancik2020fourier} obtains the second-best results that lost some image details. Only the proposed SCOPE removes streaking artifacts greatly and preserves fine image details well.
2021Cycle-free CycleGAN with invertible generator (Proposed) proposed non-standard slicePSNR34.940Ct Denoising · split: test · dose=25% of standard dose · subset=421 test imagesCycle-Free CycleGAN Using Invertible Generator for Unsupervised Low-Dose CT Denoising
Source quote
L568: Proposed │ 34.940 │ 0.821
2021Switchable FedCycleGAN vs non-federated CycleGAN proposedPSNR0.045 dBImage Denoising · clients=2Federated CycleGAN for Privacy-Preserving Image-to-Image Translation
Source quote
L314: We found that results of non-federated CycleGAN and results of Switchable FedCycleGAN showed small differences in terms of PSNR and SSIM. The difference in PSNR values is 0.045 dB, while the difference in SSIM values is 0.0017.
2021EPNet (ExtraPolationNetwork) proposedPSNR27.63Ct Reconstruction · split: test · noise=5% Gaussian plus Poisson (intensity 5e6) · geometry=fan-beam · alpha-max=60 · detector-elements=800Improving Generalizability in Limited-Angle CT Reconstruction with Sinogram Extrapolation
Source quote
L160: EPNet │ 21.92 │ 0.820 │ 23.65 │ 0.842 │ 27.63 │ 0.882 │ 30.40 │ 0.906 │ 1.8859
2021AdaIN-based CycleGAN baseline non-standard slicePSNR34.801Ct Denoising · split: test · dose=25% of standard dose · subset=421 test imagesCycle-Free CycleGAN Using Invertible Generator for Unsupervised Low-Dose CT Denoising
Source quote
L567: AdaIN-based CycleGAN │ 34.801 │ 0.824
2019FDK-CNN proposedPSNR39.99 dBArtifact Removal · training-data=8 patient datasetsDifferentiated Backprojection Domain Deep Learning for Conebeam Artifact Removal
Source quote
L472: \ PSNR [dB] │ 32.05 │ 34.39 │ 39.99 │ 41.76 │ 42.49